By means of a coaxial apparatus, high electrical breakdown experiments are carried out in the rest state and the low speed rolling state with microsecond charging and the experimental results are analyzed. The conclus...By means of a coaxial apparatus, high electrical breakdown experiments are carried out in the rest state and the low speed rolling state with microsecond charging and the experimental results are analyzed. The conclusions are: (1) the breakdown stress of water dielectric in the rolling state is in good agreement with that in Martin formula, and so is that in the rest state; (2) the breakdown stress of water dielectric in the rolling state is about 5% higher than that in the rest state; (3) the results simulated with ANSYS demonstrate that the breakdown stress of water dielectric decreases when the bubbles appear near the surface of electrodes; (4) the primary mechanism to increase the breakdown stress of water dielectric in the rolling state is that the bubbles are driven away and the number of bubbles near the surface of electrodes is decreased by rolling movement.展开更多
By means of a coaxial apparatus, microsecond charging have been carried out with ferent ethylene glycol concentrations of ethylene pressurized water breakdown experiments with different surface roughness of electrodes...By means of a coaxial apparatus, microsecond charging have been carried out with ferent ethylene glycol concentrations of ethylene pressurized water breakdown experiments with different surface roughness of electrodes and difglycol/water mixture. The experimental results about the breakdown stress and the effective time are presented. The breakdown stress is normalized to the situation that the effective time is transformed to 1 μs and analyzed. The conclusions are as follows: (1) the breakdown stress formula is modified to E = 0.561MA^-1/10teff^-1/^NP^1/8 ;(2) the coefficient M is significantly increased by surface polishing and ethylene glycol additive; (3) it is accumulative for the capacity of improving electrical breakdown strength for surface polishing, ethylene glycol additive, and pressurization, of which pressurization is the most effective method; (4) the highest stress of 235.5 kV/cm is observed in ethylene glycol/water mixture with an ethylene glycol concentration of 80% at a hydrostatic pressure of 1215.9 kPa and is about one time greater than that in pure water at constant pressure; (5) for pressurization and surface polishing, the primary mechanism to improve the breakdown strength of water dielectric is the increase in the breakdown time delay. Research results indicate great potential in the application of the high power pulse conditioning system of water dielectric.展开更多
基金supported by the National 863 Project of China(No. 807-2020, 803-5051)
文摘By means of a coaxial apparatus, high electrical breakdown experiments are carried out in the rest state and the low speed rolling state with microsecond charging and the experimental results are analyzed. The conclusions are: (1) the breakdown stress of water dielectric in the rolling state is in good agreement with that in Martin formula, and so is that in the rest state; (2) the breakdown stress of water dielectric in the rolling state is about 5% higher than that in the rest state; (3) the results simulated with ANSYS demonstrate that the breakdown stress of water dielectric decreases when the bubbles appear near the surface of electrodes; (4) the primary mechanism to increase the breakdown stress of water dielectric in the rolling state is that the bubbles are driven away and the number of bubbles near the surface of electrodes is decreased by rolling movement.
基金National 863 Project of China (No. 807-2020, 803-5051)
文摘By means of a coaxial apparatus, microsecond charging have been carried out with ferent ethylene glycol concentrations of ethylene pressurized water breakdown experiments with different surface roughness of electrodes and difglycol/water mixture. The experimental results about the breakdown stress and the effective time are presented. The breakdown stress is normalized to the situation that the effective time is transformed to 1 μs and analyzed. The conclusions are as follows: (1) the breakdown stress formula is modified to E = 0.561MA^-1/10teff^-1/^NP^1/8 ;(2) the coefficient M is significantly increased by surface polishing and ethylene glycol additive; (3) it is accumulative for the capacity of improving electrical breakdown strength for surface polishing, ethylene glycol additive, and pressurization, of which pressurization is the most effective method; (4) the highest stress of 235.5 kV/cm is observed in ethylene glycol/water mixture with an ethylene glycol concentration of 80% at a hydrostatic pressure of 1215.9 kPa and is about one time greater than that in pure water at constant pressure; (5) for pressurization and surface polishing, the primary mechanism to improve the breakdown strength of water dielectric is the increase in the breakdown time delay. Research results indicate great potential in the application of the high power pulse conditioning system of water dielectric.