As the spring equation is limited to the accuracy of mill stiffness and the linearity of the mill spring curve, the traditional gaugemeter automatic gauge control(GM-AGC) system based on spring equation cannot meet th...As the spring equation is limited to the accuracy of mill stiffness and the linearity of the mill spring curve, the traditional gaugemeter automatic gauge control(GM-AGC) system based on spring equation cannot meet the requirements of practical production. In allusion to this problem, a kind of novel GM-AGC system based on mill stretch characteristic curve was proposed. The error existing in calculating strip thickness by spring equation were analyzed first. And then the mill stretch characteristic curve which could effectively eliminate the influence of mill stiffness was described. The novel GM-AGC system has been applied successfully in a hot strip mill, the application results show that the thickness control precision is improved significantly, with the novel GM-AGC system, over 98.6% of the strip thickness deviation of 3.0 mm class can be controlled within the target tolerances of ±20 μm.展开更多
基金Project(51074051) supported by the National Natural Science Foundation of ChinaProject(N110307001) supported by the Fundamental Research Funds for the Central Universities,China
文摘As the spring equation is limited to the accuracy of mill stiffness and the linearity of the mill spring curve, the traditional gaugemeter automatic gauge control(GM-AGC) system based on spring equation cannot meet the requirements of practical production. In allusion to this problem, a kind of novel GM-AGC system based on mill stretch characteristic curve was proposed. The error existing in calculating strip thickness by spring equation were analyzed first. And then the mill stretch characteristic curve which could effectively eliminate the influence of mill stiffness was described. The novel GM-AGC system has been applied successfully in a hot strip mill, the application results show that the thickness control precision is improved significantly, with the novel GM-AGC system, over 98.6% of the strip thickness deviation of 3.0 mm class can be controlled within the target tolerances of ±20 μm.