Al2O3 - SiC - C castables with pelletized graphite addition of 0. 2%, 4% or 6% (by mass, the same hereinafter ) were prepared using brown fused corundum (8 - 5, 5 - 3 and 3 - 1 mm ) , dense fused corundum ( ≤1 a...Al2O3 - SiC - C castables with pelletized graphite addition of 0. 2%, 4% or 6% (by mass, the same hereinafter ) were prepared using brown fused corundum (8 - 5, 5 - 3 and 3 - 1 mm ) , dense fused corundum ( ≤1 and 0. 045 mm) and SiC ( ≤1 and ≤0. 064 mm) its main starting materials with mass ratio of aggregate: matrix = 71: 29, 2% silicon powder and 0. 4% B4C as antioxidants, and pelletized graphite as carbon source, Effect of pelletized graphite addition on physical properties, oxidation resistance, slag resistance arid thermal shock resistance of Al2O3 -SiC- C eastables was researched. The results show that: with the in.crease of pelletized graphite addition, the required water amount of castables increases, the bulk density and strength reduce; with 4% pelletized graphite, the eastable performs the best oxidation resistance; the increase of graphite is beneficial to the improvement of slag penetration resistance and corrosion resistance; with 6% pelletized graphite, the thermal shock resistance is the best.展开更多
The pellet injection experiments for fuelling and diagnostics have been carried out on the HL-1M tokamak. The eight-pellet injector was installed on HL-1M. A reliable monitordetector and camera system was set up to ta...The pellet injection experiments for fuelling and diagnostics have been carried out on the HL-1M tokamak. The eight-pellet injector was installed on HL-1M. A reliable monitordetector and camera system was set up to take initial pellet photographs and measure the initial pellet speed and size. High fuelling efficiency of 60 % - 100 % and a density profile with a peaking factor of 1.8 - 2.0 were obtained. The maximum density close to 10^14/cm^3 in HL-1M was achieved with newly optimized combined fuelling techniques. Two typical models of pellet ablation have been utilized for simulative calculation of the ablation rates in HL-1M. In comparison with the distribution of the measured Hα emission intensity from the digital data of the CCD camera, the experimental result seems more optimistic for core fuelling than theoretical predictions by the two models. The safety factor profile q(r) has been extracted from the information provided by the CCD camera during the pellet injection. The reliability of the measured results depends mainly on the calibration of the imaging space position. Based on the calibration, the measured q-profile becomes more reasonable than those published previously for the same shot number and same photograph.展开更多
文摘Al2O3 - SiC - C castables with pelletized graphite addition of 0. 2%, 4% or 6% (by mass, the same hereinafter ) were prepared using brown fused corundum (8 - 5, 5 - 3 and 3 - 1 mm ) , dense fused corundum ( ≤1 and 0. 045 mm) and SiC ( ≤1 and ≤0. 064 mm) its main starting materials with mass ratio of aggregate: matrix = 71: 29, 2% silicon powder and 0. 4% B4C as antioxidants, and pelletized graphite as carbon source, Effect of pelletized graphite addition on physical properties, oxidation resistance, slag resistance arid thermal shock resistance of Al2O3 -SiC- C eastables was researched. The results show that: with the in.crease of pelletized graphite addition, the required water amount of castables increases, the bulk density and strength reduce; with 4% pelletized graphite, the eastable performs the best oxidation resistance; the increase of graphite is beneficial to the improvement of slag penetration resistance and corrosion resistance; with 6% pelletized graphite, the thermal shock resistance is the best.
基金National Natural Science Foundation of China (No. 19889502)
文摘The pellet injection experiments for fuelling and diagnostics have been carried out on the HL-1M tokamak. The eight-pellet injector was installed on HL-1M. A reliable monitordetector and camera system was set up to take initial pellet photographs and measure the initial pellet speed and size. High fuelling efficiency of 60 % - 100 % and a density profile with a peaking factor of 1.8 - 2.0 were obtained. The maximum density close to 10^14/cm^3 in HL-1M was achieved with newly optimized combined fuelling techniques. Two typical models of pellet ablation have been utilized for simulative calculation of the ablation rates in HL-1M. In comparison with the distribution of the measured Hα emission intensity from the digital data of the CCD camera, the experimental result seems more optimistic for core fuelling than theoretical predictions by the two models. The safety factor profile q(r) has been extracted from the information provided by the CCD camera during the pellet injection. The reliability of the measured results depends mainly on the calibration of the imaging space position. Based on the calibration, the measured q-profile becomes more reasonable than those published previously for the same shot number and same photograph.