To enhance the nitrogen removal,a systemic monitoring of the biological and hydrological parameters of Carrousel oxidation ditch in Chongqing Jingkou Wastewater Treatment Plant was carried out to study the feasibility...To enhance the nitrogen removal,a systemic monitoring of the biological and hydrological parameters of Carrousel oxidation ditch in Chongqing Jingkou Wastewater Treatment Plant was carried out to study the feasibility of simultaneous nitrification and denitrification(SND).The variation and distribution of parameters such as flow velocity,concentration of dissolved oxygen(DO) and mixed liquor suspended solids(MLSS) in oxidation ditch were monitored and analyzed,which were major control factors for SND.The results showed that,the dimensional distribution of flow velocity,DO and MLSS were affected significantly by the operation condition of the aeration wheels.With all the four aeration wheels being in operation,DO and flow velocity were higher and the mixing of MLSS was sufficient.With three aeration wheels being in operation,the flow velocity in most of the bottom areas was enough to meet the basic requirements of no deposition,and the anaerobic region and aerobic region could exist simultaneously in one oxidation ditch,which was helpful to the process of SND.According to spatial distribution characteristics of the flow velocity,DO and soluble components under optimized condition,different functional zones of biochemical reaction in the Carrousel oxidation ditch system were defined,which might contribute to the optimization control and SND of Carrousel oxidation ditch.展开更多
Wastewater treatment using Sequencing Batch Reactor (SBR) technology is one of the state-of-the art wastewater management systems. In this technology equalization, biological treatment and secondary clarification are ...Wastewater treatment using Sequencing Batch Reactor (SBR) technology is one of the state-of-the art wastewater management systems. In this technology equalization, biological treatment and secondary clarification are performed in a single reactor in a time control sequence. SBR system is idler for the areas where the available land is limited, since it operates in less space and very cost effective even on small scales. The control of the operational parameters during the process of biological wastewater treatment is often complicated due to the dynamic change in the composition and characteristics of the raw wastewater, flow rates and other parameters influencing the complex nature of the treatment process and the process in SBR has a unique cyclic batch operation. The performance of the SBR was studied using pilot and real plant at Puducherry. The parameters considered in this study are flow, Mixed Liquor Suspended Solids (MLSS), pH, temperature, influent and effluent of Total Suspended Solids (TSS), Biochemical Oxygen Demand (BOD) and Chemical Oxygen Demand (COD). As a part of the study, the effect of constant flow and varying flow on the organic loading of the influent TSS, BOD and COD and their influence on the organic load of the effluent parameters were examined to identify the level of significance of the parameters in relation to the flow. The impact of flow on other parameters was also examined. The experimental data obtained from pilot and real plants were analyzed using multi variate statistical analyses like correlation analysis, Principal Component Analysis (PCA) and Analysis of variance (ANOVA). The statistical analysis revealed that constant flow had no significant role and the influent parameters alone had the critical role, whereas varying flow as well as the influent parameters had the significant role on the performance of SBR.展开更多
基金Project(2009ZX07315-002-01) supported by the Water Pollution Control and Management of Major Special Science and Technology, China Project(CDJXS11210001) supported by the Scientific and Technical Innovation Project of Chongqing University Graduation Foundation, China
文摘To enhance the nitrogen removal,a systemic monitoring of the biological and hydrological parameters of Carrousel oxidation ditch in Chongqing Jingkou Wastewater Treatment Plant was carried out to study the feasibility of simultaneous nitrification and denitrification(SND).The variation and distribution of parameters such as flow velocity,concentration of dissolved oxygen(DO) and mixed liquor suspended solids(MLSS) in oxidation ditch were monitored and analyzed,which were major control factors for SND.The results showed that,the dimensional distribution of flow velocity,DO and MLSS were affected significantly by the operation condition of the aeration wheels.With all the four aeration wheels being in operation,DO and flow velocity were higher and the mixing of MLSS was sufficient.With three aeration wheels being in operation,the flow velocity in most of the bottom areas was enough to meet the basic requirements of no deposition,and the anaerobic region and aerobic region could exist simultaneously in one oxidation ditch,which was helpful to the process of SND.According to spatial distribution characteristics of the flow velocity,DO and soluble components under optimized condition,different functional zones of biochemical reaction in the Carrousel oxidation ditch system were defined,which might contribute to the optimization control and SND of Carrousel oxidation ditch.
文摘Wastewater treatment using Sequencing Batch Reactor (SBR) technology is one of the state-of-the art wastewater management systems. In this technology equalization, biological treatment and secondary clarification are performed in a single reactor in a time control sequence. SBR system is idler for the areas where the available land is limited, since it operates in less space and very cost effective even on small scales. The control of the operational parameters during the process of biological wastewater treatment is often complicated due to the dynamic change in the composition and characteristics of the raw wastewater, flow rates and other parameters influencing the complex nature of the treatment process and the process in SBR has a unique cyclic batch operation. The performance of the SBR was studied using pilot and real plant at Puducherry. The parameters considered in this study are flow, Mixed Liquor Suspended Solids (MLSS), pH, temperature, influent and effluent of Total Suspended Solids (TSS), Biochemical Oxygen Demand (BOD) and Chemical Oxygen Demand (COD). As a part of the study, the effect of constant flow and varying flow on the organic loading of the influent TSS, BOD and COD and their influence on the organic load of the effluent parameters were examined to identify the level of significance of the parameters in relation to the flow. The impact of flow on other parameters was also examined. The experimental data obtained from pilot and real plants were analyzed using multi variate statistical analyses like correlation analysis, Principal Component Analysis (PCA) and Analysis of variance (ANOVA). The statistical analysis revealed that constant flow had no significant role and the influent parameters alone had the critical role, whereas varying flow as well as the influent parameters had the significant role on the performance of SBR.