Vibration can be introduced in all mechanical fields in our life.Engineers try to avoid its negative effect leading in some cases to deformation in the machines.Many researches are dedicated to study the identificatio...Vibration can be introduced in all mechanical fields in our life.Engineers try to avoid its negative effect leading in some cases to deformation in the machines.Many researches are dedicated to study the identification of damping especially in multi degree of freedom systems with particular attention to the source of energy dissipation.They focus on developing new tools or methods which may be used in real problems to obtain accurate results about the amount(or value)and the location of energy dissipation in the structure.The aim of this paper is to present an original procedure aims to experimentally determine the modal damping ratio of a mechanical structure.The proposed procedure consists of extracting the Frequency Response Function of the vibrating system using the video magnification method and then calculate the modal damping ratio using the 3-dB method.These experimental measurements are carried out by giving an external force on a cantilever beam,then the modal damping ratios are extracted using motion magnification.The obtained results show a relative error less than 4.2% between the experimental measurements and the analytical calculation for the Frequency Response Function(FRF)curves.The novelty of the paper is to combine the video magnification technique and the 3dB method in a procedure that aims to experimentally measure the modal damping of a mechanical structure.The proposed procedure in this paper represents the damping identification as a simple and easy engineering application.展开更多
Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-kno...Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-known disadvantages, such as oil leakage and difficult adjustment of damping ratio for an operating TMD. Alternatively, eddy current damping (ECD) that does not require any contact with the main structure is a potential solution. This paper discusses the design, analysis, manufacture and testing of a large-scale horizontal TMD based on ECD. First, the theoretical model of ECD is formulated, then one large-scale horizontal TMD using ECD is constructed, and finally performance tests of the TMD are conducted. The test results show that the proposed TMD has a very low intrinsic damping ratio, while the damping ratio due to ECD is the dominant damping source, which can be as large as 15% in a proper configuration. In addition, the damping ratios estimated with the theoretical model are roughly consistent with those identified from the test results, and the source of this error is investigated. Moreover, it is demonstrated that the damping ratio in the proposed TMD can be easily adjusted by varying the air gap between permanent magnets and conductive plates. In view of practical applications, possible improvements and feasibility considerations for the proposed TMD are then discussed. It is confirmed that the proposed TMD with ECD is reliable and feasible for use in structural vibration control.展开更多
In order to improve the effectiveness of traditional time domain identification methods in identifying damping ratios, a new damping ratio identification method based on pattern search is proposed by fluctuating the r...In order to improve the effectiveness of traditional time domain identification methods in identifying damping ratios, a new damping ratio identification method based on pattern search is proposed by fluctuating the reliable natural frequency obtained through traditional time domain identification methods by about 10% to build the boundary conditions, using all the initial identification results to establish the free decay response of the system, and using the pattern search method to correct the initial identification results with the residual sum of squares between the free decay response and the actually measured free-decay signal as the objective function. The proposed method deals with the actually measured free-decay signal with curve fitting and avoids enlarging the identified error caused by intermediate conversion, so it can effectively improve the identified accuracy of damping ratios. Simulations for a room-sized vibration isolation foundation show that the relative errors of analyzed three damping ratios are down to 1.05%, 1.51% and 3.7% by the proposed method from 8.42%, 5.85% and 8.5% by STD method when the noise level is 10%.展开更多
The effects of concrete's time-variant elastic modulus,casting structural components,assembling temporary shoring framework system,and shock by operating construction equipment on dynamic behavior of the reinforce...The effects of concrete's time-variant elastic modulus,casting structural components,assembling temporary shoring framework system,and shock by operating construction equipment on dynamic behavior of the reinforced concrete frame structure during construction were investigated. The dynamic tests of an eight-storey reinforced concrete frame structure during full-scaled stages of the sixth storey construction cycle were carried out by ambient vibration. Natural frequencies,corresponding mode shapes and damping ratio were determined by power spectrum processing the tested signal data in frequency domain. The changes of frequencies,mode shapes and damping ratios at different construction stages were given. The results show that natural frequencies and modal damping ratios reach the maximum at stage of casting fresh concrete,especially for higher modes. Modal damping ratios at each construction stage are less than 5% of those during usage.展开更多
The model combined by cable,girder and damper is founded to study the influence of girder vibration on cable damper 's performance of a cable-stayed bridge. The complex mode method and nondimensionalization are us...The model combined by cable,girder and damper is founded to study the influence of girder vibration on cable damper 's performance of a cable-stayed bridge. The complex mode method and nondimensionalization are used to analyze the relationship between the girder's parameters and the performance of cable-related damper. The results indicate that the performance of cable-related damper will decrease greatly when the girder frequencies are near the frequencies of cable. The smaller absolute displacement of damper's piston caused by the very small vibration phase shift of girder and cable is the physical cause of the negative impact mentioned above.展开更多
文摘Vibration can be introduced in all mechanical fields in our life.Engineers try to avoid its negative effect leading in some cases to deformation in the machines.Many researches are dedicated to study the identification of damping especially in multi degree of freedom systems with particular attention to the source of energy dissipation.They focus on developing new tools or methods which may be used in real problems to obtain accurate results about the amount(or value)and the location of energy dissipation in the structure.The aim of this paper is to present an original procedure aims to experimentally determine the modal damping ratio of a mechanical structure.The proposed procedure consists of extracting the Frequency Response Function of the vibrating system using the video magnification method and then calculate the modal damping ratio using the 3-dB method.These experimental measurements are carried out by giving an external force on a cantilever beam,then the modal damping ratios are extracted using motion magnification.The obtained results show a relative error less than 4.2% between the experimental measurements and the analytical calculation for the Frequency Response Function(FRF)curves.The novelty of the paper is to combine the video magnification technique and the 3dB method in a procedure that aims to experimentally measure the modal damping of a mechanical structure.The proposed procedure in this paper represents the damping identification as a simple and easy engineering application.
基金State Key Program of Natural Science Foundation of China Under Grant No.50738002
文摘Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-known disadvantages, such as oil leakage and difficult adjustment of damping ratio for an operating TMD. Alternatively, eddy current damping (ECD) that does not require any contact with the main structure is a potential solution. This paper discusses the design, analysis, manufacture and testing of a large-scale horizontal TMD based on ECD. First, the theoretical model of ECD is formulated, then one large-scale horizontal TMD using ECD is constructed, and finally performance tests of the TMD are conducted. The test results show that the proposed TMD has a very low intrinsic damping ratio, while the damping ratio due to ECD is the dominant damping source, which can be as large as 15% in a proper configuration. In addition, the damping ratios estimated with the theoretical model are roughly consistent with those identified from the test results, and the source of this error is investigated. Moreover, it is demonstrated that the damping ratio in the proposed TMD can be easily adjusted by varying the air gap between permanent magnets and conductive plates. In view of practical applications, possible improvements and feasibility considerations for the proposed TMD are then discussed. It is confirmed that the proposed TMD with ECD is reliable and feasible for use in structural vibration control.
基金Sponsored by the National Natural Science Foundation of China (Grant No.50675052)
文摘In order to improve the effectiveness of traditional time domain identification methods in identifying damping ratios, a new damping ratio identification method based on pattern search is proposed by fluctuating the reliable natural frequency obtained through traditional time domain identification methods by about 10% to build the boundary conditions, using all the initial identification results to establish the free decay response of the system, and using the pattern search method to correct the initial identification results with the residual sum of squares between the free decay response and the actually measured free-decay signal as the objective function. The proposed method deals with the actually measured free-decay signal with curve fitting and avoids enlarging the identified error caused by intermediate conversion, so it can effectively improve the identified accuracy of damping ratios. Simulations for a room-sized vibration isolation foundation show that the relative errors of analyzed three damping ratios are down to 1.05%, 1.51% and 3.7% by the proposed method from 8.42%, 5.85% and 8.5% by STD method when the noise level is 10%.
基金Project(50678064) supported by the National Natural Science Foundation of China
文摘The effects of concrete's time-variant elastic modulus,casting structural components,assembling temporary shoring framework system,and shock by operating construction equipment on dynamic behavior of the reinforced concrete frame structure during construction were investigated. The dynamic tests of an eight-storey reinforced concrete frame structure during full-scaled stages of the sixth storey construction cycle were carried out by ambient vibration. Natural frequencies,corresponding mode shapes and damping ratio were determined by power spectrum processing the tested signal data in frequency domain. The changes of frequencies,mode shapes and damping ratios at different construction stages were given. The results show that natural frequencies and modal damping ratios reach the maximum at stage of casting fresh concrete,especially for higher modes. Modal damping ratios at each construction stage are less than 5% of those during usage.
基金Sponsored by the Natural Science Foundation of China(Grant No.50808063)
文摘The model combined by cable,girder and damper is founded to study the influence of girder vibration on cable damper 's performance of a cable-stayed bridge. The complex mode method and nondimensionalization are used to analyze the relationship between the girder's parameters and the performance of cable-related damper. The results indicate that the performance of cable-related damper will decrease greatly when the girder frequencies are near the frequencies of cable. The smaller absolute displacement of damper's piston caused by the very small vibration phase shift of girder and cable is the physical cause of the negative impact mentioned above.