期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Studies on the Electrochemical Behavior of Bleomycin at a Co/GC Ion Implantation Modified Electrode and Its Application
1
作者 HU Jing-bo LI Qi-long 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第4期362-367,共6页
In a 0. 10 mol/L HAc-NaAc buffer solution (pH = 4. 59), a sensitive reduction peak of bleomycin was observed by linear sweep voltammetry at a Co/GC ion implantation modified electrode. The peak potential was-0. 73 V(i... In a 0. 10 mol/L HAc-NaAc buffer solution (pH = 4. 59), a sensitive reduction peak of bleomycin was observed by linear sweep voltammetry at a Co/GC ion implantation modified electrode. The peak potential was-0. 73 V(iw. SCE). The peak current was proportional to the concentration of bleomycin over the range of 5.0 × 10-8-1.0× 10-6 and 1.0× 10-6-1. 0 × 10-5 mol/L with a detection limit of 2.0 × 10-8 mol/L. The electrochemical behavior of the reduction peak of bleomycin at the Co/GC modified electrode was studied by linear sweep and cyclic voltammetry and applied to the determination of bleomycin in urine. This method is simple, rapid and reliable. The reduction process is quasi-reversible. The experiments of AES and XPS showed that Co was surely implanted into the surface of GCE and the depth distribution of Co was in good agreement with Gooses normal distribution; the implanted Co at GCE improved the electrocatalytic activity. 展开更多
关键词 Keywords Co/gc ion implantation modified electrode Electrochemical behavior Linear sweep voltammetry BLEOMYCIN
下载PDF
Studies on Electrochemical Behavior of Bleomycin and Its Interaction with DNA at a Co/GC Ion Implantation Modified Electrode 被引量:2
2
作者 胡劲波 李启隆 尚军 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2002年第3期267-271,共5页
Electrochemical investigation of Bleomycin (BLM) and its interaction with DNAat a Co/GC ion implantation modified electrode was reported for the first time. The electrochemicalbehavior of BLM at Co/GC modified electro... Electrochemical investigation of Bleomycin (BLM) and its interaction with DNAat a Co/GC ion implantation modified electrode was reported for the first time. The electrochemicalbehavior of BLM at Co/GC modified electrode has been studied by linear sweep and cyclicvoltammetry, The reaction of BLM with DNA formed an electrochemically nonactive complex, whichresulted in a decrease in the BLM equilibrium concentration and its reduction current. The decreasein peak current was proportional to DNA concentration and could be used to determination DNAconcentration. The equilibrium constant of DNA-BLM complex β was determined to be 5.16 x 10^(16).The experiments of AES and XPS showed that Co was surely implanted into the surface of GCE( glassycarbon electrode) and the depth distribution of Co was in good agreement with Gaussian normaldistribution; the implanted Co at GCE improved the electrocatalytic activity. 展开更多
关键词 Co/gc ion implantation modified electrode linear sweep voltammetry BLEOMYCIN DNA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部