期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Density Dependence of Tunnel Fire Resistance for Aerogel-Cement Mortar Coatings 被引量:2
1
作者 朱平华 JIA Zhi +3 位作者 王新杰 CHEN Chunhong LIU Hui XU Xiaoyan 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2020年第3期598-604,共7页
Five kinds of mortars with density grades of 500, 600, 700, 800, and 900 kg/m3 were prepared. Their thermal conductivity and compressive strength were measured, and the morphological changes before and after simulated... Five kinds of mortars with density grades of 500, 600, 700, 800, and 900 kg/m3 were prepared. Their thermal conductivity and compressive strength were measured, and the morphological changes before and after simulated tunnel fire were observed. To investigate the fire resistance, the interfacial temperature of a 30 mm thick aerogel-cement mortar and self-compacting concrete (SCC) in a simulated tunnel fire with the maximum temperature of 1100 ℃ for 2.5 h was tested and recorded. The results showed that as the density decreased, both compressive strength and thermal conductivity of the aerogel-cement mortar exhibited an exponential decrease. The effective fire resistance time of the mortar with 500, 600, 700, 800, and 900 kg/m^3 for protecting SCC from tunnel fire were 97 min, 114 min, 144 min, > 150 min, 136 min, respectively. 700 - 800 kg/m3 was the optimum density for engineering application of tunnel concrete fireproof coating. 展开更多
关键词 aerogel-cement mortar coating density grades compressive strength thermal conductivity simulated tunnel fire resistance
下载PDF
上一页 1 下一页 到第