AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHOD...AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan.展开更多
A measurement method of optical fiber length using timestamp technique is demonstrated. Based on IEEE1588 precise clock synchronization protocol, the principle that time delay asymmetry on two path results in synchr...A measurement method of optical fiber length using timestamp technique is demonstrated. Based on IEEE1588 precise clock synchronization protocol, the principle that time delay asymmetry on two path results in synchronization time deviation is used, and the difference between two-path delays could be deduced by measuring the synchronization time deviation reversely. Then the length of optical fiber on one path could be calculated if that on the other path is known Due to the fact that the path of Sync and Delay_Req message is symmetric, the optical pulse dispersion and the asymmetry of photoelectric detector performance on two paths are averaged by exchanging two optical fibers. The time difference between master and slave clocks is eliminated by sharing the same time base. At last, the lengths of two single-mode optical fibers are measured with the uncertainty of 0. 578 m for 3 227. 722 m and 0. 758 m for 25 491. 522 m, respectively. Thus this method has high precision and long range.展开更多
Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children.However...Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children.However,when compared with the eyes of normal children,the mechanism of growth of the axial length is so complicated that the reported findings differ significantly in terms of the measuring apparatus,assessment methods,and statistical outcome,making the rule of axial length development still unclear. In this paper, we first review the process of axial length development in normal healthy children and compare different hypotheses about certain factors that could affect the development of axial length. The results of some current research about the characteristics of axial length development in congenital cataract children are then reviewed. Lastly, the advantages and disadvantages of current axial length measurements methods are compared and analyzed.The purpose of this review is to improve our understanding of the complexity and importance of axial length development and to suggest better use of axial length monitoring measurements in congenital cataract children for pediatric ophthalmologists,with the hope of offering assistance that will enhance long-term therapeutic effects for these children.展开更多
For the linear crack skeleton of railway bridges with irregular strike,it is difficult to accurately express the crack contour feature by using a single smoothing fitting algorithm.In order to improve the measurement ...For the linear crack skeleton of railway bridges with irregular strike,it is difficult to accurately express the crack contour feature by using a single smoothing fitting algorithm.In order to improve the measurement accuracy,a polynomial curve fitting was proposed,which used the calibration point of crack contour as the boundary point,and then put them all together to produce a continuous contour curve to achieve the crack length measurement.The method was tested by measuring the linar cracks with different shapes.It is shown that this proposed algorithm can not only solve the jagged problem generated in the crack skeleton extraction process,but also improve the crack length measurement accuracy.The relative deviation is less than 0.15,and the measurement accuracy is over 98.05%,which provides a more effective means for the crack length measurement in railway bridges.展开更多
The bunch length can be measured by comparison of two frequency components of a synchrotron beam signal.An online bunch length measurement system has been implemented based on this method.Working frequencies of 3 GHz ...The bunch length can be measured by comparison of two frequency components of a synchrotron beam signal.An online bunch length measurement system has been implemented based on this method.Working frequencies of 3 GHz and 500 MHz were selected,and the raw data was acquired by digital oscilloscope and was resampled and analyzed using the MATLAB software platform at bunch-by-bunch rate.The constructed system was employed to study the bunch length synchronous oscillation phenomenon during injection.The beam experiments demonstrated a time resolution of less than 0.5 ps.展开更多
An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for...An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for measurement is identified by the machine, the placement of the measurement calipers is automatically determined by fitting an active contour model to the structure of interest. The fetal biparietal diameter (BPD) and femur length (FL) are then measured automatically. The validation data set contained 167 and 197 B-mode images for BPD and FL measurements, respectively. The images were acquired using 4 different ultrasound scanners, which resulted in varied image quality and gain settings. The mean gestational age (GA) of the fetuses was 19.4 weeks, range 16 to 41 weeks. A measurement success rate of 90% was achieved for both BPD and FL. The correlation coefficients between the manual and automatic measurements were 0.995 (BPD) and 0.967 (FL), mean errors were 0.5 mm (BPD) and -1.7 mm (FL) and error range with 95% confidence interval (CI) were ﹣3.8 - 4.8 mm (BPD) and ﹣11.4 - 8.1 mm (FL). The automatic measurement results were consistent in both high and low gain settings. The intraclass correlation coefficients between manual and automatic measurements were 0.995 (95% CI;0.981 - 0.999) for BPD in high gain, 1.0 (95% CI;0.998 - 1.0) for BPD in low gain, 0.998 (95% CI;0.991 - 0.999) for FL in high gain and 0.999 (95% CI;0.996 - 1.0) for FL in low gain settings. The method was implemented on a prototype, portable ultrasound machine designed to be used in low- and middle-income countries (LMIC). The overall performance of the method supports our hypothesis that automated methods can be used and are beneficial in a clinical setting.展开更多
Purpose:The aim of this paper was to examine the distribution of macular,retinal nerve fiber layer(RNFL)thickness and optic disc parameters of myopic and hyperopic eyes in comparison withemmetropic control eyes and to...Purpose:The aim of this paper was to examine the distribution of macular,retinal nerve fiber layer(RNFL)thickness and optic disc parameters of myopic and hyperopic eyes in comparison withemmetropic control eyes and to investigate their variation according to axial length(AL)andspherical equivalent(SE)in healthy children.Methods:This study included 293 pairs of eyes of 293children(145 boys and 148 girks),ranging in age from 6 to 17 years,Subjects were dividedaccording to SE in control(emmetropia,99 children),myopia(100 children)and hyperopia(94children)groups and according to axial AL in 68 short(<22.00 mm,68),medium(from≥22.00 mmto 25.00 mm,189)and long eyes(>25.00 mm,36).Macular parameters,RNFL thickness and opticdisc morphology were assessed by the Cirrus^(TM) HD-OCT.AL was measured using the IOL-Mastersystem.Littmann's formula was used for calculating the corrected AL-related ocular magnification.Results Mean age(±SD)was 10.84±3.05 years;mean(±SD)SE was+0.14±0.51 D(range from8.75 to+8.25 D)and mean AL(±SD)was 23.12±1.49.Average RNFL thickness,averagemacular thickness and macular volume decreased as AL and myopia increased.No correlationsbetween AL/SE and optic disc parameters were found after correcting for magnification effect.Conclusions:AL and refractive error affect measurements of macular and RNFL thickness inhealthy children.To make a correct interpretation of ocT measurements,ocular magnificationeffect should be taken into account by clinicians or OCT manufacturers.展开更多
In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical r...In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical reflected pulses are obtained from a single nanosecond pulse injected at the input due to the difference in lengths of the reference and test fibers. The lengths of the different optical fibers have been measured with this technique with high resolution and fast response time. The measured results show that, the proposed technique has a comparable performance with the well-known length measurement systems.展开更多
Cephalopods play key roles in global marine ecosystems as both predators and preys.Regressive estimation of original size and weight of cephalopod from beak measurements is a powerful tool of interrogating the feeding...Cephalopods play key roles in global marine ecosystems as both predators and preys.Regressive estimation of original size and weight of cephalopod from beak measurements is a powerful tool of interrogating the feeding ecology of predators at higher trophic levels.In this study,regressive relationships among beak measurements and body length and weight were determined for an octopus species(Octopus variabilis),an important endemic cephalopod species in the northwest Pacific Ocean.A total of 193 individuals(63 males and 130 females) were collected at a monthly interval from Jiaozhou Bay,China.Regressive relationships among 6 beak measurements(upper hood length,UHL;upper crest length,UCL;lower hood length,LHL;lower crest length,LCL;and upper and lower beak weights) and mantle length(ML),total length(TL) and body weight(W) were determined.Results showed that the relationships between beak size and TL and beak size and ML were linearly regressive,while those between beak size and W fitted a power function model.LHL and UCL were the most useful measurements for estimating the size and biomass of O.variabilis.The relationships among beak measurements and body length(either ML or TL) were not significantly different between two sexes;while those among several beak measurements(UHL,LHL and LBW) and body weight(W) were sexually different.Since male individuals of this species have a slightly greater body weight distribution than female individuals,the body weight was not an appropriate measurement for estimating size and biomass,especially when the sex of individuals in the stomachs of predators was unknown.These relationships provided essential information for future use in size and biomass estimation of O.variabilis,as well as the estimation of predator/prey size ratios in the diet of top predators.展开更多
This paper presents a new high accuracy measurement for hot deformation of large structure. Its princple and technological features, several key technologies and factors that affect measurement accuracy are discussed,...This paper presents a new high accuracy measurement for hot deformation of large structure. Its princple and technological features, several key technologies and factors that affect measurement accuracy are discussed, the uncertainty of measurement is analyzed, and measures to ensure accuracy are given.展开更多
Objectives: this research was conducted to describe the ultrasonic measurements of the foot full measurements (FFM) and their importance in the antenatal care (ANC). Material and methods: the Descriptive quantitative ...Objectives: this research was conducted to describe the ultrasonic measurements of the foot full measurements (FFM) and their importance in the antenatal care (ANC). Material and methods: the Descriptive quantitative cross-sectional study conducted in the ultrasound department at Alshaekh Mohammed Ali Fadol hospital in Omdurman locality. The study included 400 healthy Sudanese pregnant women whom in the 1st (late), 2nd and 3rd trimesters (i.e., after 10 weeks gestational age) of different parity and ages (15 years old and above);they have regular menstrual cycle and well certain of their last menstrual period and calculated date of delivery. Ultrasonographic measurement of Full Foot Length1 (FFL1), Foot Full Length2 (FFL2), and Foot Full Width (FFW) of all pregnant women were done. Sonographically we measured fetal foot from 14 to 40 weeks of gestation. Results: the study revealed that the mean FFL1 was 58.7 ± 12.9 mm. The minimum measurement was 18.8 mm, and the maximum was 89.1 mm, while the mean value of FFL2 was 53.4 ± 11.4 mm, with minimum value 17.5 mm and maximum 81.7 mm, and the mean FFW was 23.7 ± 5.1 mm, with minimum value 7.0 mm and maximum 38.0 mm. Conclusion: a strongly significant relationships were observed between (FFL1, FFL2, FFW) and gestational age (p = 0.00). However there is no significant difference between the FFL1, FFL2, and correlations with sex of embryo, residence, occupation, parity, maternal height, socioeconomic status, bleeding during this pregnancy, chronic illness, and caesarian section, moreover there are significant correlations between the FFL1, FFL2 and the (maternal age, maternal weight, and body mass index), but in the measurement of the fetal FFW there were no significant correlations with (sex of embryo, maternal age, body mass index, residence, occupation, parity, socioeconomic status, bleeding during this pregnancy, chronic illness, and caesarian section). Also there are significant correlations between the FFW and the maternal weight and height.展开更多
基金Supported by National Key Basic Research Program of China(973 Program,No.2013CB967000)National Natural Science Foundation of China(No.81271052)
文摘AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan.
基金National Natural Science Foundation of China(No.61271120/F010508)National Science and Technology Support Program(No.2014BAK02BO2,No.2014BAK02BO5)National Science and Technology Major Projects(broadband wireless2015ZX03001011-002)
文摘A measurement method of optical fiber length using timestamp technique is demonstrated. Based on IEEE1588 precise clock synchronization protocol, the principle that time delay asymmetry on two path results in synchronization time deviation is used, and the difference between two-path delays could be deduced by measuring the synchronization time deviation reversely. Then the length of optical fiber on one path could be calculated if that on the other path is known Due to the fact that the path of Sync and Delay_Req message is symmetric, the optical pulse dispersion and the asymmetry of photoelectric detector performance on two paths are averaged by exchanging two optical fibers. The time difference between master and slave clocks is eliminated by sharing the same time base. At last, the lengths of two single-mode optical fibers are measured with the uncertainty of 0. 578 m for 3 227. 722 m and 0. 758 m for 25 491. 522 m, respectively. Thus this method has high precision and long range.
基金Key Program for Clinical Discipline of Ministry of Health between 2010 and 2012(Grant No.2010-2012-439-175)
文摘Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children.However,when compared with the eyes of normal children,the mechanism of growth of the axial length is so complicated that the reported findings differ significantly in terms of the measuring apparatus,assessment methods,and statistical outcome,making the rule of axial length development still unclear. In this paper, we first review the process of axial length development in normal healthy children and compare different hypotheses about certain factors that could affect the development of axial length. The results of some current research about the characteristics of axial length development in congenital cataract children are then reviewed. Lastly, the advantages and disadvantages of current axial length measurements methods are compared and analyzed.The purpose of this review is to improve our understanding of the complexity and importance of axial length development and to suggest better use of axial length monitoring measurements in congenital cataract children for pediatric ophthalmologists,with the hope of offering assistance that will enhance long-term therapeutic effects for these children.
基金National Defense Pre-Research Fund Project(No.060601)Wanqiao Education Fund Project(No.06010023)。
文摘For the linear crack skeleton of railway bridges with irregular strike,it is difficult to accurately express the crack contour feature by using a single smoothing fitting algorithm.In order to improve the measurement accuracy,a polynomial curve fitting was proposed,which used the calibration point of crack contour as the boundary point,and then put them all together to produce a continuous contour curve to achieve the crack length measurement.The method was tested by measuring the linar cracks with different shapes.It is shown that this proposed algorithm can not only solve the jagged problem generated in the crack skeleton extraction process,but also improve the crack length measurement accuracy.The relative deviation is less than 0.15,and the measurement accuracy is over 98.05%,which provides a more effective means for the crack length measurement in railway bridges.
基金supported by the National Natural Science Foundation of China(Nos.11375255 and 11375254)
文摘The bunch length can be measured by comparison of two frequency components of a synchrotron beam signal.An online bunch length measurement system has been implemented based on this method.Working frequencies of 3 GHz and 500 MHz were selected,and the raw data was acquired by digital oscilloscope and was resampled and analyzed using the MATLAB software platform at bunch-by-bunch rate.The constructed system was employed to study the bunch length synchronous oscillation phenomenon during injection.The beam experiments demonstrated a time resolution of less than 0.5 ps.
文摘An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for measurement is identified by the machine, the placement of the measurement calipers is automatically determined by fitting an active contour model to the structure of interest. The fetal biparietal diameter (BPD) and femur length (FL) are then measured automatically. The validation data set contained 167 and 197 B-mode images for BPD and FL measurements, respectively. The images were acquired using 4 different ultrasound scanners, which resulted in varied image quality and gain settings. The mean gestational age (GA) of the fetuses was 19.4 weeks, range 16 to 41 weeks. A measurement success rate of 90% was achieved for both BPD and FL. The correlation coefficients between the manual and automatic measurements were 0.995 (BPD) and 0.967 (FL), mean errors were 0.5 mm (BPD) and -1.7 mm (FL) and error range with 95% confidence interval (CI) were ﹣3.8 - 4.8 mm (BPD) and ﹣11.4 - 8.1 mm (FL). The automatic measurement results were consistent in both high and low gain settings. The intraclass correlation coefficients between manual and automatic measurements were 0.995 (95% CI;0.981 - 0.999) for BPD in high gain, 1.0 (95% CI;0.998 - 1.0) for BPD in low gain, 0.998 (95% CI;0.991 - 0.999) for FL in high gain and 0.999 (95% CI;0.996 - 1.0) for FL in low gain settings. The method was implemented on a prototype, portable ultrasound machine designed to be used in low- and middle-income countries (LMIC). The overall performance of the method supports our hypothesis that automated methods can be used and are beneficial in a clinical setting.
文摘Purpose:The aim of this paper was to examine the distribution of macular,retinal nerve fiber layer(RNFL)thickness and optic disc parameters of myopic and hyperopic eyes in comparison withemmetropic control eyes and to investigate their variation according to axial length(AL)andspherical equivalent(SE)in healthy children.Methods:This study included 293 pairs of eyes of 293children(145 boys and 148 girks),ranging in age from 6 to 17 years,Subjects were dividedaccording to SE in control(emmetropia,99 children),myopia(100 children)and hyperopia(94children)groups and according to axial AL in 68 short(<22.00 mm,68),medium(from≥22.00 mmto 25.00 mm,189)and long eyes(>25.00 mm,36).Macular parameters,RNFL thickness and opticdisc morphology were assessed by the Cirrus^(TM) HD-OCT.AL was measured using the IOL-Mastersystem.Littmann's formula was used for calculating the corrected AL-related ocular magnification.Results Mean age(±SD)was 10.84±3.05 years;mean(±SD)SE was+0.14±0.51 D(range from8.75 to+8.25 D)and mean AL(±SD)was 23.12±1.49.Average RNFL thickness,averagemacular thickness and macular volume decreased as AL and myopia increased.No correlationsbetween AL/SE and optic disc parameters were found after correcting for magnification effect.Conclusions:AL and refractive error affect measurements of macular and RNFL thickness inhealthy children.To make a correct interpretation of ocT measurements,ocular magnificationeffect should be taken into account by clinicians or OCT manufacturers.
文摘In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical reflected pulses are obtained from a single nanosecond pulse injected at the input due to the difference in lengths of the reference and test fibers. The lengths of the different optical fibers have been measured with this technique with high resolution and fast response time. The measured results show that, the proposed technique has a comparable performance with the well-known length measurement systems.
基金funded by The National Natural Science Foundation of China(41006083)The Shandong Provincial Natural Science Foundation,China(ZR2010DQ026)+1 种基金The Fundamental Research Funds for the Central Universities(201022001,201262004)The Specialized Research Program for Marine Public Welfare Industry from the State Oceanic Administration,P.R.China(200805066)
文摘Cephalopods play key roles in global marine ecosystems as both predators and preys.Regressive estimation of original size and weight of cephalopod from beak measurements is a powerful tool of interrogating the feeding ecology of predators at higher trophic levels.In this study,regressive relationships among beak measurements and body length and weight were determined for an octopus species(Octopus variabilis),an important endemic cephalopod species in the northwest Pacific Ocean.A total of 193 individuals(63 males and 130 females) were collected at a monthly interval from Jiaozhou Bay,China.Regressive relationships among 6 beak measurements(upper hood length,UHL;upper crest length,UCL;lower hood length,LHL;lower crest length,LCL;and upper and lower beak weights) and mantle length(ML),total length(TL) and body weight(W) were determined.Results showed that the relationships between beak size and TL and beak size and ML were linearly regressive,while those between beak size and W fitted a power function model.LHL and UCL were the most useful measurements for estimating the size and biomass of O.variabilis.The relationships among beak measurements and body length(either ML or TL) were not significantly different between two sexes;while those among several beak measurements(UHL,LHL and LBW) and body weight(W) were sexually different.Since male individuals of this species have a slightly greater body weight distribution than female individuals,the body weight was not an appropriate measurement for estimating size and biomass,especially when the sex of individuals in the stomachs of predators was unknown.These relationships provided essential information for future use in size and biomass estimation of O.variabilis,as well as the estimation of predator/prey size ratios in the diet of top predators.
文摘This paper presents a new high accuracy measurement for hot deformation of large structure. Its princple and technological features, several key technologies and factors that affect measurement accuracy are discussed, the uncertainty of measurement is analyzed, and measures to ensure accuracy are given.
文摘Objectives: this research was conducted to describe the ultrasonic measurements of the foot full measurements (FFM) and their importance in the antenatal care (ANC). Material and methods: the Descriptive quantitative cross-sectional study conducted in the ultrasound department at Alshaekh Mohammed Ali Fadol hospital in Omdurman locality. The study included 400 healthy Sudanese pregnant women whom in the 1st (late), 2nd and 3rd trimesters (i.e., after 10 weeks gestational age) of different parity and ages (15 years old and above);they have regular menstrual cycle and well certain of their last menstrual period and calculated date of delivery. Ultrasonographic measurement of Full Foot Length1 (FFL1), Foot Full Length2 (FFL2), and Foot Full Width (FFW) of all pregnant women were done. Sonographically we measured fetal foot from 14 to 40 weeks of gestation. Results: the study revealed that the mean FFL1 was 58.7 ± 12.9 mm. The minimum measurement was 18.8 mm, and the maximum was 89.1 mm, while the mean value of FFL2 was 53.4 ± 11.4 mm, with minimum value 17.5 mm and maximum 81.7 mm, and the mean FFW was 23.7 ± 5.1 mm, with minimum value 7.0 mm and maximum 38.0 mm. Conclusion: a strongly significant relationships were observed between (FFL1, FFL2, FFW) and gestational age (p = 0.00). However there is no significant difference between the FFL1, FFL2, and correlations with sex of embryo, residence, occupation, parity, maternal height, socioeconomic status, bleeding during this pregnancy, chronic illness, and caesarian section, moreover there are significant correlations between the FFL1, FFL2 and the (maternal age, maternal weight, and body mass index), but in the measurement of the fetal FFW there were no significant correlations with (sex of embryo, maternal age, body mass index, residence, occupation, parity, socioeconomic status, bleeding during this pregnancy, chronic illness, and caesarian section). Also there are significant correlations between the FFW and the maternal weight and height.