Objective: To evaluate the relation between epicardial adipose tissue (EAT) thickness and also pericoronary fat assessed by Multidetector Computed Tomography (MDCT) with both calcium score and significance of coronary...Objective: To evaluate the relation between epicardial adipose tissue (EAT) thickness and also pericoronary fat assessed by Multidetector Computed Tomography (MDCT) with both calcium score and significance of coronary artery disease. Background: Epicardial adipose tissue (the visceral fat of the heart present under the visceral layer of the pericardium) has the same origin of abdominal visceral fat, which is known to be strongly related to the development of coronary artery atherosclerosis. Multidetector CT (MDCT) provides an accurate and reproducible quantification of EAT due to its high spatial and temporal resolution. Patients and Methods: The current study included 70 patients with low-intermediate probability of coronary artery disease. All patients were subjected to 256 Multidetectors CT to assess EAT thickness, the mean thickness of the pericoronary fat surrounding the three coronary arteries and coronary calcium score. Also coronary CT angiography was done and patients were then divided into 3 groups according to significance of coronary atherosclerosis: Group 1: No atherosclerosis (20 patients), Group 2: Non obstructive atherosclerosis (luminal narrowing less than 50% in diameter) (25 patients), Group3: Obstructive atherosclerosis (luminal narrowing ≥ 50%) (25 patients). Results: The mean EAT thickness and the mean pericoronary fat thickness were significantly higher in patients with obstructive coronary artery disease (CAD) with stenosis > 50% (group 3) compared to other groups with normal coronaries or non obstructive (CAD). ROC curve was used to define the best cut off value of the thickness of both EAT and pericoronary fat in predicting the obstructive CAD group which was ≥7.2 and 12.6 mm for epicardial and pericoronary fat respectively. Also there is a positive correlation between both epicardial adipose tissue and pericoronary fat thickness and the coronary calcium score. Conclusion: EAT thickness and pericoronary fat thickness can be used in predicting the significance of coronary artery disease.展开更多
CBCT scanners have been widely used in angiography,radiotherapy guidance,mammography and oral maxillofacial imaging.To cut detector size,reduce manufacturing costs and radiation dose while keeping a reasonable FOV,the...CBCT scanners have been widely used in angiography,radiotherapy guidance,mammography and oral maxillofacial imaging.To cut detector size,reduce manufacturing costs and radiation dose while keeping a reasonable FOV,the flat panel detector can be placed off-center horizontally.This scanning configuration extends the FOV effectively.However,each projection is transversely truncated,bringing errors and artifacts in reconstruction.In this paper,a simple but practical method is proposed for this scanning geometry based on truncation compensation and the modified FDK algorithm.Numerical simulations with jaw phantom were conducted to evaluate the accuracy and practicability of the proposed method.A novel CBCT system for maxillofacial imaging is used for clinical test,which is equipped with an off-center small size flat panel detector.Results show that reconstruction accuracy is acceptable for clinical use,and the image quality appears sufficient for specific diagnostic requirements.It provides a novel solution for clinical CBCT system,in order to reduce radiation dose and manufacturing cost.展开更多
To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dual-energy X-ray photon counter with a lutetium-oxyorthosilicate photomultiplier detector system, three comp...To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dual-energy X-ray photon counter with a lutetium-oxyorthosilicate photomultiplier detector system, three comparators, two microcomputers, and two frequency-voltage converters. X-ray photons are detected using the detector system, and the event pulses are input to three comparators simultaneously to determine threshold energies. At a tube voltage of 100 kV, the three threshold energies are 16, 35 and 52 keV, and two energy ranges are 16 - 35 and 52 - 100 keV. X-ray photons in the two ranges are counted using microcomputers, and the logical pulses from the two microcomputers are input to two frequency-voltage converters. In dual-energy computed tomography (CT), the tube voltage and current were 100 kV and 0.29 mA, respectively. Two tomograms were obtained simultaneously at two energy ranges. The energy ranges for gadolinium-L-edge and K-edge CT were 16 - 35 and 52 - 100 keV, respectively. The maximum count rate of dual-energy CT was 105 kilocounts per second with energies ranging from 16 to 100 keV, and the exposure time for tomography was 19.6 min.展开更多
Purpose: To present an application of the anisotropic diffusion (AD) method to improve the accuracy of the functional images of perfusion parameters such as cerebral blood flow (CBF), cerebral blood volume (CBV) and m...Purpose: To present an application of the anisotropic diffusion (AD) method to improve the accuracy of the functional images of perfusion parameters such as cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) generated from cerebral CT perfusion studies using multi-detector row CT (MDCT). Materials and Methods: Continuous scans (1 sec/rotation ×60 sec) consisting of four 5-mm-thick contiguous slices were acquired after an intravenous injection of iodinated contrast material in 6 patients with cerebrovascular disease using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. New image data were generated by thinning out the above original images at an interval of 2 sec or 3 sec. The thinned-out images were then interpolated by linear interpolation to generate the same number of images as originally acquired. The CBF, CBV and MTT images were generated using deconvolution analysis based on singular value decomposition. Results: When using the AD method, the correlation coefficient between the MTT values obtained from the original and thinned-out images was significantly improved. Furthermore, the coefficients of variation of the CBF, CBV and MTT values in the white matter significantly decreased as compared to not using the AD method. Conclusion: Our results suggest that the AD method is useful for improving the accuracy of the functional images of perfusion parameters and for reducing radiation exposure in cerebral CT perfusion studies using MDCT.展开更多
目的:探究双层探测器光谱CT多定量参数术前对胃癌Lauren分型的诊断价值。方法:收集48例术前在双层探测器光谱CT上行腹部增强检查且术后病理确诊为胃腺癌的患者,获取双层探测器光谱CT多定量参数及术后病理资料。按Lauren分型将入组病例...目的:探究双层探测器光谱CT多定量参数术前对胃癌Lauren分型的诊断价值。方法:收集48例术前在双层探测器光谱CT上行腹部增强检查且术后病理确诊为胃腺癌的患者,获取双层探测器光谱CT多定量参数及术后病理资料。按Lauren分型将入组病例分为三组,其中弥漫型17例,混合型21例,肠型10例。通过后处理软件得到碘浓度图及有效原子序数图,测量胃癌病灶及同层面腹主动脉期及静脉期的碘浓度及有效原子序数,计算标准化碘浓度及标准化有效原子序数。比较增强各期不同分型间各参数值的差异,对有统计学意义的参数绘制其受试者工作特征(receiver operating characteristic,ROC)曲线评估各参数的诊断效能,按约登指数为最大原则得出诊断阈值及曲线下面积(area under curve,AUC)。结果:弥漫型胃癌的各项参数值均高于肠型及混合型胃癌,弥漫型与混合型、弥漫型与肠型差异均具有统计学意义(P<0.05),而混合型与肠型除动脉期标准化有效原子序数差异具有统计学意义(P<0.05)外,余各参数值差异均无统计学意义(P>0.05)。动脉期及静脉期碘浓度、标准化碘浓度、有效原子序数及标准化有效原子序数诊断弥漫型胃癌的AUC分别为0.758、0.819、0.739、0.861及0.889、0.825、0.832、0.881;诊断阈值分别为1.26、0.12、7.91、0.75及1.81、0.52、8.28、0.91;动静脉期碘浓度、标准化碘浓度中,静脉期AUC最大;动静脉期有效原子序数、标准化有效原子序数中,静脉期AUC最大。结论:双层探测器光谱CT碘浓度及有效原子序数可为术前鉴别胃癌Lauren分型提供更多信息,具有一定的临床价值。展开更多
Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detec...Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detector row computed tomographic (MDCT) abdominal image, using a bioelectrical body composition analyzer scale as the reference standard. CT images of 21 patients with previously measured LBW (mLBW) were processed using computer-assisted, vendor-specific software (Advantage Windows 4.2;GE Healthcare, Inc). For each transverse image, a fat-fraction was automatically measured as the number of fat pixels (-200 to -50 HU) divided by the total number of pixels having an attenuation value ≥-200 HU. Estimated LBW (eLBW) of five single contiguous sections was calculated in each of three abdominal regions (upper abdomen, mid abdomen and pelvis) by multiplying TBW by (1 – fat-fraction). Bland-Altman plot with limits of agreement was used to assess agreement between mLBW and eLBW. The mean mLBW for all patients was 56 kg (range, 39 - 75 kg). Mean differences and limits of agreement between mLBW and eLBW measurements for the upper abdomen, mid abdomen and pelvis reported were -8.9 kg (-25.6 kg, +7.5 kg), -10.6 kg (-27.7 kg, +6.4 kg), and +0.5 kg (-12.8 kg, +13.8 kg) respectively. eLBW deriving directly from a transverse CT image of the pelvis can accurately predict mLBW.展开更多
文摘Objective: To evaluate the relation between epicardial adipose tissue (EAT) thickness and also pericoronary fat assessed by Multidetector Computed Tomography (MDCT) with both calcium score and significance of coronary artery disease. Background: Epicardial adipose tissue (the visceral fat of the heart present under the visceral layer of the pericardium) has the same origin of abdominal visceral fat, which is known to be strongly related to the development of coronary artery atherosclerosis. Multidetector CT (MDCT) provides an accurate and reproducible quantification of EAT due to its high spatial and temporal resolution. Patients and Methods: The current study included 70 patients with low-intermediate probability of coronary artery disease. All patients were subjected to 256 Multidetectors CT to assess EAT thickness, the mean thickness of the pericoronary fat surrounding the three coronary arteries and coronary calcium score. Also coronary CT angiography was done and patients were then divided into 3 groups according to significance of coronary atherosclerosis: Group 1: No atherosclerosis (20 patients), Group 2: Non obstructive atherosclerosis (luminal narrowing less than 50% in diameter) (25 patients), Group3: Obstructive atherosclerosis (luminal narrowing ≥ 50%) (25 patients). Results: The mean EAT thickness and the mean pericoronary fat thickness were significantly higher in patients with obstructive coronary artery disease (CAD) with stenosis > 50% (group 3) compared to other groups with normal coronaries or non obstructive (CAD). ROC curve was used to define the best cut off value of the thickness of both EAT and pericoronary fat in predicting the obstructive CAD group which was ≥7.2 and 12.6 mm for epicardial and pericoronary fat respectively. Also there is a positive correlation between both epicardial adipose tissue and pericoronary fat thickness and the coronary calcium score. Conclusion: EAT thickness and pericoronary fat thickness can be used in predicting the significance of coronary artery disease.
基金Supported by National Key Technology R&D Program of the Ministry of Science and Technology(No.2012BAI07B05)
文摘CBCT scanners have been widely used in angiography,radiotherapy guidance,mammography and oral maxillofacial imaging.To cut detector size,reduce manufacturing costs and radiation dose while keeping a reasonable FOV,the flat panel detector can be placed off-center horizontally.This scanning configuration extends the FOV effectively.However,each projection is transversely truncated,bringing errors and artifacts in reconstruction.In this paper,a simple but practical method is proposed for this scanning geometry based on truncation compensation and the modified FDK algorithm.Numerical simulations with jaw phantom were conducted to evaluate the accuracy and practicability of the proposed method.A novel CBCT system for maxillofacial imaging is used for clinical test,which is equipped with an off-center small size flat panel detector.Results show that reconstruction accuracy is acceptable for clinical use,and the image quality appears sufficient for specific diagnostic requirements.It provides a novel solution for clinical CBCT system,in order to reduce radiation dose and manufacturing cost.
文摘To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dual-energy X-ray photon counter with a lutetium-oxyorthosilicate photomultiplier detector system, three comparators, two microcomputers, and two frequency-voltage converters. X-ray photons are detected using the detector system, and the event pulses are input to three comparators simultaneously to determine threshold energies. At a tube voltage of 100 kV, the three threshold energies are 16, 35 and 52 keV, and two energy ranges are 16 - 35 and 52 - 100 keV. X-ray photons in the two ranges are counted using microcomputers, and the logical pulses from the two microcomputers are input to two frequency-voltage converters. In dual-energy computed tomography (CT), the tube voltage and current were 100 kV and 0.29 mA, respectively. Two tomograms were obtained simultaneously at two energy ranges. The energy ranges for gadolinium-L-edge and K-edge CT were 16 - 35 and 52 - 100 keV, respectively. The maximum count rate of dual-energy CT was 105 kilocounts per second with energies ranging from 16 to 100 keV, and the exposure time for tomography was 19.6 min.
文摘Purpose: To present an application of the anisotropic diffusion (AD) method to improve the accuracy of the functional images of perfusion parameters such as cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) generated from cerebral CT perfusion studies using multi-detector row CT (MDCT). Materials and Methods: Continuous scans (1 sec/rotation ×60 sec) consisting of four 5-mm-thick contiguous slices were acquired after an intravenous injection of iodinated contrast material in 6 patients with cerebrovascular disease using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. New image data were generated by thinning out the above original images at an interval of 2 sec or 3 sec. The thinned-out images were then interpolated by linear interpolation to generate the same number of images as originally acquired. The CBF, CBV and MTT images were generated using deconvolution analysis based on singular value decomposition. Results: When using the AD method, the correlation coefficient between the MTT values obtained from the original and thinned-out images was significantly improved. Furthermore, the coefficients of variation of the CBF, CBV and MTT values in the white matter significantly decreased as compared to not using the AD method. Conclusion: Our results suggest that the AD method is useful for improving the accuracy of the functional images of perfusion parameters and for reducing radiation exposure in cerebral CT perfusion studies using MDCT.
文摘目的:探究双层探测器光谱CT多定量参数术前对胃癌Lauren分型的诊断价值。方法:收集48例术前在双层探测器光谱CT上行腹部增强检查且术后病理确诊为胃腺癌的患者,获取双层探测器光谱CT多定量参数及术后病理资料。按Lauren分型将入组病例分为三组,其中弥漫型17例,混合型21例,肠型10例。通过后处理软件得到碘浓度图及有效原子序数图,测量胃癌病灶及同层面腹主动脉期及静脉期的碘浓度及有效原子序数,计算标准化碘浓度及标准化有效原子序数。比较增强各期不同分型间各参数值的差异,对有统计学意义的参数绘制其受试者工作特征(receiver operating characteristic,ROC)曲线评估各参数的诊断效能,按约登指数为最大原则得出诊断阈值及曲线下面积(area under curve,AUC)。结果:弥漫型胃癌的各项参数值均高于肠型及混合型胃癌,弥漫型与混合型、弥漫型与肠型差异均具有统计学意义(P<0.05),而混合型与肠型除动脉期标准化有效原子序数差异具有统计学意义(P<0.05)外,余各参数值差异均无统计学意义(P>0.05)。动脉期及静脉期碘浓度、标准化碘浓度、有效原子序数及标准化有效原子序数诊断弥漫型胃癌的AUC分别为0.758、0.819、0.739、0.861及0.889、0.825、0.832、0.881;诊断阈值分别为1.26、0.12、7.91、0.75及1.81、0.52、8.28、0.91;动静脉期碘浓度、标准化碘浓度中,静脉期AUC最大;动静脉期有效原子序数、标准化有效原子序数中,静脉期AUC最大。结论:双层探测器光谱CT碘浓度及有效原子序数可为术前鉴别胃癌Lauren分型提供更多信息,具有一定的临床价值。
文摘Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detector row computed tomographic (MDCT) abdominal image, using a bioelectrical body composition analyzer scale as the reference standard. CT images of 21 patients with previously measured LBW (mLBW) were processed using computer-assisted, vendor-specific software (Advantage Windows 4.2;GE Healthcare, Inc). For each transverse image, a fat-fraction was automatically measured as the number of fat pixels (-200 to -50 HU) divided by the total number of pixels having an attenuation value ≥-200 HU. Estimated LBW (eLBW) of five single contiguous sections was calculated in each of three abdominal regions (upper abdomen, mid abdomen and pelvis) by multiplying TBW by (1 – fat-fraction). Bland-Altman plot with limits of agreement was used to assess agreement between mLBW and eLBW. The mean mLBW for all patients was 56 kg (range, 39 - 75 kg). Mean differences and limits of agreement between mLBW and eLBW measurements for the upper abdomen, mid abdomen and pelvis reported were -8.9 kg (-25.6 kg, +7.5 kg), -10.6 kg (-27.7 kg, +6.4 kg), and +0.5 kg (-12.8 kg, +13.8 kg) respectively. eLBW deriving directly from a transverse CT image of the pelvis can accurately predict mLBW.