Objective:To analyze the value of multi-slice spiral computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of carpal joint injury.Methods:A total of 130 patients with suspected wrist injuries admi...Objective:To analyze the value of multi-slice spiral computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of carpal joint injury.Methods:A total of 130 patients with suspected wrist injuries admitted to the Department of Orthopedics of our hospital from January 2023 to January 2024 were selected and randomly divided into a single group(n=65)and a joint group(n=65).The single group was diagnosed using multi-slice spiral CT,and the joint group was diagnosed using multi-slice spiral CT and magnetic resonance imaging,with pathological diagnosis as the gold standard.The diagnostic results of both groups were compared to the gold standard,and the diagnostic energy efficiency of both groups was compared.Results:The diagnostic results of the single group compared with the gold standard were significant(P<0.05).The diagnostic results of the joint group compared with the gold standard were not significant(P>0.05).The sensitivity and accuracy of diagnosis in the joint group were significantly higher than that in the single group(P<0.05).The specificity of diagnosis in the joint group was higher as compared to that in the single group(P>0.05).Conclusion:The combination of multi-slice spiral CT and MRI was highly accurate in diagnosing wrist injuries,and the misdiagnosis rate and leakage rate were relatively low.Hence,this diagnostic program is recommended to be popularized.展开更多
Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention t...Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.展开更多
Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collect...Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collected, of which 6 cases were normal, 5 cases were subjected to cirrhosis and hypertension of portal vein, 42 cases had portal tumor thrombus of hepatic cancer, and the remaining 4 cases showed lymph node enlargment in hilar of liver. All data of the patients came from conventional multi-slice spiral CT double phase of liver. Contrast media was 1.5–2 ml/kg with the injection rate being 2.5–3 ml/s. Axis and 3D portography was analyzed and compared in 42 cases of portal tumor thrombus of hepatic cancer.Results: According to portal tumor thrombus position, 42 cases were fallen into three categories: left (13 cases), right (20 cases), main (9 cases) of potal vein. There was no difference between axis and 3D portography in displaying portal tumor thrombus of hepatic cancer (P>0.05), but 3D portography showing collateral branches was better than axis portography after main portal vein thrombus.Conclusion: Multi-slice spiral CT 3D portography can display the position and types of portal tumor thrombus of hepatic cancer. 3D combined with axis portography can better evaluate the portal tumor thrombus of hepatic cancer and guide to select the therapies. Key words portal vein - tumor thrombus - multi-slice CT - 3 dimension imaging展开更多
AIM: To determine the possible predisposing factors of bezoar-induced small bowel obstruction(b I-Sb O) and to discuss the diagnostic value of multi-slice spiral computed tomography,particularly contrast-enhanced scan...AIM: To determine the possible predisposing factors of bezoar-induced small bowel obstruction(b I-Sb O) and to discuss the diagnostic value of multi-slice spiral computed tomography,particularly contrast-enhanced scanning,in this condition.METHODS: A total of 35 b I-Sb O cases treated at our hospital from January 2007 to December 2013 were retrospectively analysed.Complete clinical and computed tomography(CT) data of the patients were available and confirmed by surgery.SbO was clinically diagnosed on the basis of clinical manifestations.Of the 35 patients,18 underwent abdominal and pelvic CT planar scanning with GE 64-slice spiral CT and 17 underwent abdominal and pelvic CT planar scanning with GE 64-slice spiral CT combined with contrastenhanced examination.Original images were processed using a GE ADW4.3 workstation to obtain MPR,CPR,MIP and CTA images.The images of all patients were evaluated by two abdominal imaging experts.The main analytical contents of planar scanning included intestinal bezoar conditions,changes in the intestinal wall and changes in peri-intestinal conditions.Vascular hyperaemia and arterial blood supply conditions at a specific obstruction site and the distal end of the obstruction site were evaluated through contrastenhanced examination.RESULTS: The proportion of males to females among the 35 cases was 1:1.69(13:22); median age was 63.3 years.The following cases were observed: 29(82.8%) cases occurred in autumn and winter and showed a history of consuming high amounts of persimmon and hawthorn; 19(54.3%) cases revealed a history of gastrointestinal surgery; 19 exhibited incomplete dentition,with missing partial or whole posterior teeth; 26 suffered from obstruction at the ileum.A total of 51 bezoars were found in these patients,of whom 16(45.7%) had multiple bezoars.CT planar scanning of bezoars showed lumps with mottled gas inside the intestinal cavity.Furthermore,9 cases of bezoars had envelopes and 11 cases were accompanied with thickening of the distal wall of the obstructed bowel.Scanning of 17 cases was enhanced; the results revealed that the mesenteric blood vessels at the obstruction site and the proximal site were dilated,and a total of 7 cases were accompanied with distal vascular dilation and intestinal wall thickening.CONCLUSION: b I-Sb O exhibits regional and seasonal characteristics.CT planar and contrast-enhanced scanning can be applied to diagnose and observe vascular conditions in obstructed zones.展开更多
BACKGROUND: During the past years, the number of liver transplantation has increased greatly, but the number of available organs has not increased. In view of the critical shortage of organs, the indications for livin...BACKGROUND: During the past years, the number of liver transplantation has increased greatly, but the number of available organs has not increased. In view of the critical shortage of organs, the indications for living-related liver transplantation (LRLT) have broadened since experience with the procedure has been achieved. This study was undertaken to assess the value of multi-slice spiral CT (MSCT) angiography in evaluating the hepatic arterial and veinous anatomy of potential donors for LRLT. METHODS: MSCT was performed after intravenous injection of contrast material at 3 ml/s. The total dose was calculated as 2 ml/kg. Twenty LRLT donors (2 men and 18 women) were subjected to MSCT angiography of hepatic blood vessels. These were generated by volume rendering and maximum intensity projection, while curved planar reformation was added in 5 patients. RESULTS: We identified 10 important hepatic vascular variants in 9 of the 20 donors (4 arterial, 4 venous, and 2 portal venous variants). In hepatic arterial variants, two had a replaced right hepatic artery arising from the superior mesenteric artery, an accessory right hepatic artery from the superior mesenteric artery and a replaced left hepatic artery arising from the left gastric artery. In hepatic venous variants, three had an accessory inferior right hepatic vein and one had two accessory inferior right hepatic veins. In hepatic portal venous variants, two had trifurcation of the main portal vein. CONCLUSIONS: As a non-invasive and reliable method, MSCT angiography is of value in the clinical evaluation of LRLT donors. MSCT angiography should be recommended as a routine preoperative examination for potential LRLT donors.展开更多
The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postopera...The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postoperative cone-beam computed tomography (CBCT) images. Second, the reliability and accuracy of this condylar volume quantification method was assessed. The mandibles of 20 patients (11 female and 9 male) who underwent bimaxillary surgery were semi-automatically extracted from MSCT/CBCT scans and rendered in 3D. The resulting condyles were spatially matched by using an anatomical landmark-based registration procedure. A standardized sphere was created around each condyle, and the condylar bone volume within this selected region of interest was automatically calculated. To investigate the reproducibility of the method, inter- and intra-observer reliability was calculated for assessments made by two experienced radiologists twice five months apart in a set of ten randomly selected patients. To test the accuracy of the bone segmentation, the inner and outer bone structures of one dry mandible, scanned according to the clinical set-up, were compared with the gold standard, micro-CT. Thirty-eight condyles showed a significant (P〈O.05) mean bone volume decrease of 26.4%_ 11.4% (502.9 mm3+ 268.1 mm3). No significant effects of side, sex or age were found. Good to excellent (ICC〉 0.6) intra- and inter-observer reliability was observed for both MSCT and CBCT. Moreover, the bone segmentation accuracy was less than one voxel (0.4 mm) for MSCT (0.3 mm __. 0.2 mm) and CBCT (0.4 mm _ 0.3 mm), thus indicating the clinical potential of this method for objective follow-up in pathological condylar resorption.展开更多
Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral ...Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral computed tomography (MSCT) guidance before the procedure. Methods: A series of 58 consecutive patients with refractory paroxysmal AF were enrolled to undergo segmental radiofrequency ablation ofPV ostia. The 36 male and 22 female patients with mean age of (57.4±9.5) (32-79) years and no obvious organic heart disease. Before ablation, patients received MSCT to generate 3-dimentional image of the left atrium (LA) and proximal PVs. Patients then underwent segmental radiofrequency ablation ofPV ostia using PV circular mapping catheter manipulated several times to ensure complete isolation between PVs and LA. Results: No complications occurred during the procedure. One patient developed delayed cardiac tamponade, which was drained percutaneously. The mean follow-up time was (17.1±9.3) months. Forty-one patients (95%) experienced improved quality of life one month after the procedure. Thirty-six patients (83%) showed stable sinus rhythm, while 10 patients (23%) required additional anti-arrhythmic drugs. AF returned≥1 time in 6 (14%) patients who underwent anti-arrhythmic drug therapy, but the number of episodes was less than that before the procedure. However, one patient experienced recurrent episodes of atrial flutter. Conclusion: It is safe and effective to perform segmental radiofrequency ablation of PV ostia for patients with refractory paroxysmal AF using MSCT guidance mappening.展开更多
BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of t...BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of transformation into malignant tumors is as high as 20%-30%.AIM To investigate the value of multi-slice spiral computed tomography(MSCT)in the differential diagnosis of GST and benign gastric polyps,and GST risk stratification assessment.METHODS We included 64 patients with GST(GST group)and 60 with benign gastric polyps(control group),confirmed by pathological examination after surgery in PLA General Hospital,from January 2016 to June 2021.The differences in the MSCT imaging characteristic parameters and enhanced CT values between the two groups before surgery were compared.According to the National Institutes of Health’s standard,GST is divided into low-and high-risk groups for MSCT imaging characteristic parameters and enhanced CT values.RESULTS The incidences of extraluminal growth,blurred boundaries,and ulceration in the GST group were significantly higher than those in the control group(P<0.05).The CT values and enhanced peak CT values in the arterial phase in the CST group were higher than those in the control group(P<0.05).The MSCT differential diagnosis of GST and gastric polyp sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and areas under the curve(AUCs)were 73.44%,83.33%,26.56%,16.67%,0.784,respectively.The receiver operating characteristic curves were plotted with the arterial CT value and enhanced peak CT value,with a statistical difference.The results showed that the sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of arterial CT in the differential diagnosis of GST and gastric polyps were 80.18%,62.20%,19.82%,37.80%,and 0.710,respectively.The sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of the enhanced peak CT value in the differential diagnosis of GST and gastric polyps were 67.63%,60.40%,32.37%,39.60%,and 0.710,respectively.The incidence of blurred lesion boundaries and ulceration in the high-risk group was significantly higher than that in the low-risk group(P<0.05).The arterial phase and enhanced peak CT values in the high-risk group were significantly higher than those in the low-risk group(P<0.05).CONCLUSION Presurgical MSCT examination has important value in the differential diagnosis of GST and gastric benign polyps and can effectively evaluate the risk grade of GST patients.展开更多
BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can c...BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can clearly demonstrate the 3D space of fractures and detect fractures at a higher rate.AIM To investigate the clinical value of multi-slice spiral CT 3D reconstruction in the diagnosis of unstable pelvic fractures in the elderly as well as the effect of less invasive stabilization.METHODS A total of 86 patients with unstable pelvic fractures treated between March 2016 and March 2019 underwent femoral supracondylar bone traction before surgery.Pelvic radiography and multi-row spiral CT were performed successively once the patient’s vital signs and hemodynamic indices were stable.Secondary processing of the original data was performed to obtain 3D reconstruction images and determine the vertical displacement of the pelvis.After basic or complete reduction,minimally invasive internal fixation using hollow lag screws was performed.The detection rates of fracture location and classification by X-ray and CT reconstruction were compared.Patients were divided into two groups according to the presence or absence of preoperative 3D reconstruction to compare postoperative reduction,wound healing time,fracture healing time,hospitalization time,visual analog scale(VAS)score,poor internal fixation,and functional recovery.RESULTS The diagnostic coincidence rates of X-rays for pubic symphysis,ilium wing,sacroiliac periarticular,and sacral fractures were lower than those of CT reconstruction.The coincidence rate of CT reconstruction in the clinical classification of pelvic fractures was 100%,whereas 11 cases were misdiagnosed by X-ray;the total coincidence rate was 87.21%.The total excellent and good rates of postoperative reduction were significantly higher in the study group than in the control group(P<0.05).The wound healing,fracture healing,and hospitalization times were significantly shorter in the study group than in the control group(P<0.05).The VAS scores decreased in both groups postoperatively and were lower in the study group than in the control group(P<0.05).The total incidence of poor postoperative internal fixation was significantly lower in the study group than in the control group(P<0.05).The overall rate of postoperative functional recovery was significantly higher in the study group than in the control group(P<0.05).CONCLUSION Multi-slice spiral CT has high guiding significance for the diagnosis,classification,and treatment of unstable pelvic fractures in the elderly.Preoperative 3D reconstruction can effectively shorten the operation time and promote fracture healing,while minimally invasive internal fixation can effectively reduce pain and promote functional recovery of fracture sites,making it worthy of clinical application.展开更多
BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enha...BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enhance clinical treatment of the disease.AIM To explore the role of computed tomography(CT)recurrence in evaluating EGC after ESD treatment.METHODS We retrospectively recruited patients from our endoscopy department,between January 2002 and December 2015,and analyzed their basic characteristics,including symptoms,CT results,and results of endoscopy with biopsy,among others.RESULTS Among a total of 2150 patients EGC patients surveyed,1362 met our inclusion and exclusion criteria and were therefore enrolled in our study.The cohort’s sensitivity of CT for recurrent GC and specificity were 44.22%and 43.86%,respectively,with negative and positive predictive values of 40.15%(275/685)and 48.01%(325/677),respectively.The area under the curve of arterial and venous CT values for recurrent EGC were 0.545,and 0.604,respectively.Receiver operating characteristic curve revealed no statistically significant differences between arterial and venous CT values for recurrent EGC.CONCLUSION Enhanced CT has superior diagnostic efficacy,but less accuracy,compared to gold standard techniques in patients with recurrent EGC.展开更多
Objective:To investigate the value of tumor markers in colorectal cancer with multi-slice spiral CT in the diagnosis of elderly colorectal cancer.Methods:From January 2016 to September 2017 year period, 73 elderly pat...Objective:To investigate the value of tumor markers in colorectal cancer with multi-slice spiral CT in the diagnosis of elderly colorectal cancer.Methods:From January 2016 to September 2017 year period, 73 elderly patients with colorectal cancer treated in our hospital were selected as observation group;64 elderly patients with intestinal benign lesions were selected as control group during the same period. Serum samples were collected to detect contents of CEA, CA72-4, CA19-9 and CYFRA21-1 by Roche luminous immunoassay analyzer, and multi slice spiral CT was used.Results:Serum levels of CEA, CA72-4, CA19-9 and CYFRA21-1 levels of the observation group were significantly higher than that of the control group;the positive rate of CEA, CA72-4, CA19-9, CYFRA21-1 and their combined detection were all significantly higher than that of the control group;positive rate of MSCT in the observation group was higher than the control group;positive rates of tumor markers combining with MSCT examination of colorectal cancer were higher than that of combined detection of tumor markers and MSCT examination;but there was no significant difference in positive rate of combined detection of tumor markers and the positive rate of MSCT detection of colorectal cancer.Conclusion:Colorectal cancer tumor markers combined with multi-slice spiral CT in the diagnosis of colorectal cancer in elderly has important research value, can significantly improve the positive rate of diagnosis.展开更多
AIM: To establish models of portal vein occlusion of hepatic VX2 tumor in rabbits and to evaluate the value of multi-slice CT. METHODS: Forty New Zealand rabbits were divided into 4 groups according to digital table...AIM: To establish models of portal vein occlusion of hepatic VX2 tumor in rabbits and to evaluate the value of multi-slice CT. METHODS: Forty New Zealand rabbits were divided into 4 groups according to digital table: Immediate group (group A; transplantation of tumor immediately after the portal vein occlusion), 3-wk group (group B; transplantation of tumor at 3 wk after the portal vein occlusion), negative control group (group C) and positive control group (group D), 10 rabbits in each group. Hepatic VX2 tumor was transplanted with abdominalembedding innoculation immediately after the portal vein occlusion and at 3 wk after the portal vein occlusion. Meanwhile, they were divided into negative control group (Left external branch of portal vein was occluded by sham-operation, and left exite was embedded and inoculated pseudoly) and positive control group (Transplanted tumor did not suffer from the portal vein occlusion). All rabbits were scanned with multi-slice CT. RESULTS: All 40 animals were employed in the final analysis without death. Tumor did not grow in both immediate group and 3-wk group. In 3-wk group, left endite was atrophied and growth of tumor was inhibited. The maximal diameter of tumor was significantly smaller than that in positive control group (2.55±0.46 vs 3.59±0.37 cm, t = 5.57, P 〈 0.001). Incidences of metastasis in the liver and lung were lower in 3-wk group than those in positive control group (10% vs 400, and 90% vs 100%, respectively). The expression intensities of the vascular endothelium growth factor (VEGF) in groups A, B, C and D were 0.10±0.06, 0.66±0.21, 0.28±0.09 and 1.48±0.32, respectively. VEGF expression level in the test group A was significantly lower than that in the negative control group C (t = 5.07; P 〈 0.001).In addition, VEGF expression in the test group B was significantly lower than that in the positive control group D (t = 6.38; P 〈 0.001). Scanning with multi-slice CT showed that displaying rate of hepatic artery branches was obviously lower in grade Ⅲ(40%) than that in grade Ⅰ(70%) and Ⅱ(100%) (P 〈 0.05); but there was no significant difference in displaying rate of the portal vein at various grades. Values of blood flow (BF) of the liver, blood volume (BV), mean transit time (MTT) and permeability of vascular surface (PS) were lower in the immediate group and 3-wk group than those in control groups, but values of hepatic arterial fraction (HAF) were increased. Significant positive correlations were existed between BF and BV (r = 0.905, P 〈 0.01), and between BF and PS (r = 0.967, P 〈 0.01), between BV and PS (r = 0.889, P 〈 0.01). A significant negative correlation existed between PV and HAF (r = -0.768, P 〈 0.01), between PS and HAF (r = -0.557, P 〈 0.01). The values of BF, BV and PS had a positive correlation with VEGF (rBF = 0.842, rBV = 0.579, rPS = 0.811, P 〈 0.01) . However, there was no significant correlation between the values of MTT and HAF and the VEGF expression (rMTt = 0.066, rHAF = -0.027). CONCLUSION: Ligating the left external branch of portal vein is an ideal way to establish models of portal vein occlusion in rabbits with hepatic VX2 tumor. Multi slice CT plays a key role in evaluating effect of portal vein occlusion.展开更多
Transcatheter aortic valve implantation(TAVI) has been shown in improve outcome of severe aortic stenosis(AS) patients, deemed surgical high-risk or inoperable, and has grown popular in the past decade. The procedure ...Transcatheter aortic valve implantation(TAVI) has been shown in improve outcome of severe aortic stenosis(AS) patients, deemed surgical high-risk or inoperable, and has grown popular in the past decade. The procedure requires accurate prior planning, and demands an integration of a "Heart Team" consisted from cardiac surgeons, interventional cardiologists, and imaging experts. The role of cardiac imaging and especially multi-slice computerized tomography(MSCT) has been a mainstay of pre-evaluation of severe AS patients that allows to accurately depict and size the cardiac and vascular structures, and has become the primary tool for procedural planning. This article is aimed to evaluate current uses of MSCT in severe AS patients undergoing TAVI, delineate the various measurements derived from this modality and review current literature regarding it's advantages over other techniques.展开更多
Most of coal is produced from open-cut mines in Southeast Asian countries. However, the conditions of their surface mines are worsening each year: the stripping ratio is increasing, approaching economic ratio and the...Most of coal is produced from open-cut mines in Southeast Asian countries. However, the conditions of their surface mines are worsening each year: the stripping ratio is increasing, approaching economic ratio and the regulation of environmental protection. To meet the demand for coal, underground mines have to be developed in the near future. Under these circumstances, the development of new coal mines from open-cut highwalls are being planned in Southeast Asian Countries. Moreover, some of the Southeast Asian mines have thick coal seams. However, if the conventional mining systems and designs introduced in US, Australia and European Countries are applied, several geotechnical issues can be expected due to the mines' weak geological conditions. From these backgrounds, this paper proposed a punch multi-slice mining system with stowing for thick coal seam under weak geological conditions and discussed its applicability and suitable design by means of numerical analysis.展开更多
Objective:To analyze the value of multislice spiral CT in the diagnosis and resectability of pancreatic cancer.Method:56 patients with pancreatic cancer treated in our hospital from January 2018 to October 2019 were s...Objective:To analyze the value of multislice spiral CT in the diagnosis and resectability of pancreatic cancer.Method:56 patients with pancreatic cancer treated in our hospital from January 2018 to October 2019 were selected as the research subjects.All patients underwent multi-phase scanning by multislice spiral CT.According to the results of the images,observe whether the pancreatic cancer has affected the blood vessels surrounding the pancreas,evaluate the resectability based on the results of the examination,and analyze the final results of the operation which was taken as the standard.Results:all the 56 cases presented slightly low density or equal density,and 28 cases had complete outline.Multi-slice spiral assessment of patients’vascular invasion types found that 192 branches can be resected with 70 branches cannot;Multi-slice spiral assessment of the main arterial and venous invasion grades around the pancreas of the patients found that 212 branches can be resected with 50 branches cannot;Multi-slice spiral CT was used to evaluate the resectability of pancreatic cancer compared with surgical results.The accuracy of resectable types of vascular invasion was 72.52%;the accuracy of resectable vascular invasion grades was 79.39%.Conclusion:the application of multi-slice spiral CT in the diagnosis of pancreatic cancer can provide a clear understanding of the condition of vascular invasion and distant metastasis,and the accuracy of assessing resection can reach more than 70.00%,which provides a reference for clinical application.展开更多
Objective:To compare and analyze the clinical diagnostic value of multi-slice spiral CT and enhanced MRI for primary liver cancer(PLC),and to summarize the imaging findings.Methods:The research subjects in this articl...Objective:To compare and analyze the clinical diagnostic value of multi-slice spiral CT and enhanced MRI for primary liver cancer(PLC),and to summarize the imaging findings.Methods:The research subjects in this article were 50 patients with PLC who were admitted to our hospital from 2017 April to 2018 September.After the patients were admitted,they were examined by multi-slice spiral CT and enhanced MRI scanning,and the pathological diagnosis results were followed up.Relevant information was reviewed and analyzed.Results:The detection rate of multi-slice spiral CT was higher than that of MRI in the portal venous phase lesion detection.The difference was statistically significant(P<0.05).The detection rate of lesions in the arterial phase and delayed phase was not statistically significant(P>0.05);the diagnostic accuracy of multi-slice spiral CT was 85.96%,and the diagnostic accuracy of enhanced MRI scanning was 91.11%,which was not statistically significant(P>0.05).MRI scans showed the capsules of primary liver cancer better than CT,but the difference was not statistically significant(P>0.05).Conclusion:In conclusion,both multi-slice spiral CT and enhanced MRI can be used for the effective diagnosis of primary liver cancer intrahepatic lesions.The diagnostic value of the two is equivalent,but enhanced MRI has a slightly higher diagnostic accuracy and can be used as the preferred method.展开更多
Background Many studies have shown that cancer cell differentiation and microvascular invasion play a principle role in cancer progression and metastasis, and non-invasive imaging techniques such as CT, MRI and US ass...Background Many studies have shown that cancer cell differentiation and microvascular invasion play a principle role in cancer progression and metastasis, and non-invasive imaging techniques such as CT, MRI and US assessing the differentiation and the surgical resectibility and the prognosis of cancers are now of great importance. This study aimed to explore the correlation of triple-phase multi-slice CT scan with the histological differentiation and intratumor microvascular/lymphatic invasion of progressive gastric cancer.Methods The present study included 64 patients with gastric cancer, all of whom underwent routinal and dual-phase contrast enhancement multi-slice CT examinations of the upper abdomen before surgery. The post-operative specimens were used for determination of histological differentiation, cancer cell invasion of intratumoral microvascular/lyrnphatic vessel identified by CD34 and D2-40 expression. Correlations between contrast enhancement ratio (CER) of triple-phase multi-slice CT scan in gastric cancer and histological differentiation as well as intraturnoral microvascular/lymphatic invasion were compared and analyzed.Results There was a significant correlation between CER of triple-phase CT scan in gastric cancer and tumor histological differentiation (P〈0.05). CER of the arterial phase in gastric cancer with intratumoral microvascular invasion was significantly higher than that without invasion (0.61±0.28 vs. 0.46±0.14, P 〈0.05); CER of the arterial-parenchymal phase was significantly lower in gastric cancer with intratumoral microvascular invasion than that without invasion (1.81±0.39 vs. 2.28±0.80, P〈0.05). However, CER of the parenchymal phase in gastric cancer with intratumoral lymphatic invasion was significantly higher than that without invasion (1.25±0.57 vs. 1.00±0.35, P〈0.05).Conclusions CER of triple-phase multi-slice CT scan in gastric cancer is closely correlated with intratumoral microvascular and lymphatic invasion, and also could be used as a marker for histological differentiation.展开更多
Background This study aimed to investigate multi-slice CT contrast-enhanced presentation of gastric cancer and its correlation with histo-differentiation and p53 and P-glycoprotein (P-gp) expression. Methods Sixty-s...Background This study aimed to investigate multi-slice CT contrast-enhanced presentation of gastric cancer and its correlation with histo-differentiation and p53 and P-glycoprotein (P-gp) expression. Methods Sixty-six patients with gastric cancer in the present study underwent a multi-slice CT preoperative routine and dual-phase contrast-enhanced examination of the upper abdomen; postoperative specimens were used to determine histo-differentiation and the expression of p53 and P-gp. The correlation of multi-slice CT contrast-enhanced presentation with histo-differentiation and expression of p53 and P-gp was analyzed. Results The dual-phase contrast-enhanced ratio (CER) was not correlated with the histo-differentiation of gastric cancer (P 〉0.05). Positive expression of p53 and P-gp was significantly higher in the cases of layered or heterogeneous enhancement than in the cases of homogenous enhancement (P 〈0.05). Positive expression of p53 was also correlated with the arterial phase CER, tumor size and lymph node metastasis (P 〈0.05), but not with infiltration thickness of the gastric wall, nor was it correlated with the portal phase CER (P 〉0.05). Positive expression of P-gp was only correlated with the portal phase CER (P=0.005). Conclusions Differently enhanced pattern and CER of the arterial and portal phase in gastric cancer correlate with its different histo-differentiation and expression of p53 and P-gp respectively. In addition, tumor size and lymph node metastasis of gastric cancer relate to the expression of p53.展开更多
Background Multi-slice CT liver perfusion has been widely used in experimental studies of hemodynamic changes in liver lesions, and is usually performed as an adjunct to a conventional CT examination because of its hi...Background Multi-slice CT liver perfusion has been widely used in experimental studies of hemodynamic changes in liver lesions, and is usually performed as an adjunct to a conventional CT examination because of its high temporal and spatial resolution, simple protocol, good reproducibility, and ability to measure hemodynamic changes of liver tissues at the capillary level. Experimental rat models, especially those of induced liver cancer, are often used in studies of hemodynamic changes in liver cancer. Carcinogenesis in rats has a similar pathological progression and characteristics resembling those in human liver cancer; as a result, rat models are often used as ideal animal models in the study of human liver cancer. However, liver perfusion imaging in rats is difficult to perform, because rats' livers are so small that different concentrations, flow rates, and dose of contrast agents during the CT perfusion scanning can influence the quality of liver perfusion images in rats. The purpose of this study, therefore, was to investigate the optimal scan protocol for the imaging of hepatic perfusion using a deconvolution mathematical method in rats by comparing the results of rats in different injection conditions of the contrast agent, including concentration, rate and time. Methods Plain CT scan conditions in eighty 2-month-old male Wistar rats were 5.0 mm slice thickness, 5.0 mm interval, 1.0 pitch, 120 kV tube voltage, 60 mA tube current, 512x512 matrix, and FOV 9.6 cm. Perfusion scanning was carried out with different concentrations of diatrizoate (19%, 38%, 57%, and 76%), different injection rates (0.3 and 0.5 ml/s), and different injection times (1, 2-3, 4-5, and 6 seconds). The above conditions were randomly matched and adjusted to determine the best perfusion scan protocol. Three-phase contrast-enhanced scanning was performed after CT perfusion. Histological examination of the liver tissues with hematoxylin and eosin stains was done after CT scanning. Results When the concentration of the contrast agent was 19% or 38%, no pseudo-color map was created. The viscosity increased when the concentration of the contrast agent was 76%; so it is difficult to inject the contrast agent at such a high concentration. Also no pseudo-color map was generated when the injection time was short (1, 2-3, and 4-5 seconds) or the injection rate was low (0.3 ml/s). The best perfusion images and perfusion parameters were obtained during 50 seconds scanning. Each rat was given an injection of 57% diatrizoate at 0.5 mils via the tail vein using a high-pressure syringe for 6 seconds. The perfusion parameters included hepatic blood flow (HBF), hepatic blood volume (HBV), mean transit time (MTT) of the contrast agent, capillary permeability-surface area product (PS), hepatic arterial index (HAl), hepatic artery perfusion (HAP), and hepatic portal perfusion (HPP). All these parameters reflected the perfusion status of liver parenchyma in normal rats. Three phases of enhancement were modified according to the time-density curves (TDCs) of the perfusion imaging: hepatic arterial phase (7 seconds), hepatic portal venous phase (15 seconds), and a delayed phase (23-31 seconds). On examination by microscopy, the liver tissues were pathologically normal. Conclusions The appropriate protocol with multi-slice spiral CT liver perfusion reflected normal liver hemodynamics in rats. This study laid a solid foundation for further investigation of the physiological characteristics of liver cancer in a rat model, and was an important supplement to and reference for conventional contrast-enhanced CT scans.展开更多
文摘Objective:To analyze the value of multi-slice spiral computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of carpal joint injury.Methods:A total of 130 patients with suspected wrist injuries admitted to the Department of Orthopedics of our hospital from January 2023 to January 2024 were selected and randomly divided into a single group(n=65)and a joint group(n=65).The single group was diagnosed using multi-slice spiral CT,and the joint group was diagnosed using multi-slice spiral CT and magnetic resonance imaging,with pathological diagnosis as the gold standard.The diagnostic results of both groups were compared to the gold standard,and the diagnostic energy efficiency of both groups was compared.Results:The diagnostic results of the single group compared with the gold standard were significant(P<0.05).The diagnostic results of the joint group compared with the gold standard were not significant(P>0.05).The sensitivity and accuracy of diagnosis in the joint group were significantly higher than that in the single group(P<0.05).The specificity of diagnosis in the joint group was higher as compared to that in the single group(P>0.05).Conclusion:The combination of multi-slice spiral CT and MRI was highly accurate in diagnosing wrist injuries,and the misdiagnosis rate and leakage rate were relatively low.Hence,this diagnostic program is recommended to be popularized.
文摘Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.
文摘Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collected, of which 6 cases were normal, 5 cases were subjected to cirrhosis and hypertension of portal vein, 42 cases had portal tumor thrombus of hepatic cancer, and the remaining 4 cases showed lymph node enlargment in hilar of liver. All data of the patients came from conventional multi-slice spiral CT double phase of liver. Contrast media was 1.5–2 ml/kg with the injection rate being 2.5–3 ml/s. Axis and 3D portography was analyzed and compared in 42 cases of portal tumor thrombus of hepatic cancer.Results: According to portal tumor thrombus position, 42 cases were fallen into three categories: left (13 cases), right (20 cases), main (9 cases) of potal vein. There was no difference between axis and 3D portography in displaying portal tumor thrombus of hepatic cancer (P>0.05), but 3D portography showing collateral branches was better than axis portography after main portal vein thrombus.Conclusion: Multi-slice spiral CT 3D portography can display the position and types of portal tumor thrombus of hepatic cancer. 3D combined with axis portography can better evaluate the portal tumor thrombus of hepatic cancer and guide to select the therapies. Key words portal vein - tumor thrombus - multi-slice CT - 3 dimension imaging
文摘AIM: To determine the possible predisposing factors of bezoar-induced small bowel obstruction(b I-Sb O) and to discuss the diagnostic value of multi-slice spiral computed tomography,particularly contrast-enhanced scanning,in this condition.METHODS: A total of 35 b I-Sb O cases treated at our hospital from January 2007 to December 2013 were retrospectively analysed.Complete clinical and computed tomography(CT) data of the patients were available and confirmed by surgery.SbO was clinically diagnosed on the basis of clinical manifestations.Of the 35 patients,18 underwent abdominal and pelvic CT planar scanning with GE 64-slice spiral CT and 17 underwent abdominal and pelvic CT planar scanning with GE 64-slice spiral CT combined with contrastenhanced examination.Original images were processed using a GE ADW4.3 workstation to obtain MPR,CPR,MIP and CTA images.The images of all patients were evaluated by two abdominal imaging experts.The main analytical contents of planar scanning included intestinal bezoar conditions,changes in the intestinal wall and changes in peri-intestinal conditions.Vascular hyperaemia and arterial blood supply conditions at a specific obstruction site and the distal end of the obstruction site were evaluated through contrastenhanced examination.RESULTS: The proportion of males to females among the 35 cases was 1:1.69(13:22); median age was 63.3 years.The following cases were observed: 29(82.8%) cases occurred in autumn and winter and showed a history of consuming high amounts of persimmon and hawthorn; 19(54.3%) cases revealed a history of gastrointestinal surgery; 19 exhibited incomplete dentition,with missing partial or whole posterior teeth; 26 suffered from obstruction at the ileum.A total of 51 bezoars were found in these patients,of whom 16(45.7%) had multiple bezoars.CT planar scanning of bezoars showed lumps with mottled gas inside the intestinal cavity.Furthermore,9 cases of bezoars had envelopes and 11 cases were accompanied with thickening of the distal wall of the obstructed bowel.Scanning of 17 cases was enhanced; the results revealed that the mesenteric blood vessels at the obstruction site and the proximal site were dilated,and a total of 7 cases were accompanied with distal vascular dilation and intestinal wall thickening.CONCLUSION: b I-Sb O exhibits regional and seasonal characteristics.CT planar and contrast-enhanced scanning can be applied to diagnose and observe vascular conditions in obstructed zones.
文摘BACKGROUND: During the past years, the number of liver transplantation has increased greatly, but the number of available organs has not increased. In view of the critical shortage of organs, the indications for living-related liver transplantation (LRLT) have broadened since experience with the procedure has been achieved. This study was undertaken to assess the value of multi-slice spiral CT (MSCT) angiography in evaluating the hepatic arterial and veinous anatomy of potential donors for LRLT. METHODS: MSCT was performed after intravenous injection of contrast material at 3 ml/s. The total dose was calculated as 2 ml/kg. Twenty LRLT donors (2 men and 18 women) were subjected to MSCT angiography of hepatic blood vessels. These were generated by volume rendering and maximum intensity projection, while curved planar reformation was added in 5 patients. RESULTS: We identified 10 important hepatic vascular variants in 9 of the 20 donors (4 arterial, 4 venous, and 2 portal venous variants). In hepatic arterial variants, two had a replaced right hepatic artery arising from the superior mesenteric artery, an accessory right hepatic artery from the superior mesenteric artery and a replaced left hepatic artery arising from the left gastric artery. In hepatic venous variants, three had an accessory inferior right hepatic vein and one had two accessory inferior right hepatic veins. In hepatic portal venous variants, two had trifurcation of the main portal vein. CONCLUSIONS: As a non-invasive and reliable method, MSCT angiography is of value in the clinical evaluation of LRLT donors. MSCT angiography should be recommended as a routine preoperative examination for potential LRLT donors.
基金the Coordination for the Improvement of Higher Education Personnel(CAPES)programmeScience without borders from Brazilian governmentthe Research Foundation Flanders(FWO)from Flemish government for the fellowship support
文摘The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postoperative cone-beam computed tomography (CBCT) images. Second, the reliability and accuracy of this condylar volume quantification method was assessed. The mandibles of 20 patients (11 female and 9 male) who underwent bimaxillary surgery were semi-automatically extracted from MSCT/CBCT scans and rendered in 3D. The resulting condyles were spatially matched by using an anatomical landmark-based registration procedure. A standardized sphere was created around each condyle, and the condylar bone volume within this selected region of interest was automatically calculated. To investigate the reproducibility of the method, inter- and intra-observer reliability was calculated for assessments made by two experienced radiologists twice five months apart in a set of ten randomly selected patients. To test the accuracy of the bone segmentation, the inner and outer bone structures of one dry mandible, scanned according to the clinical set-up, were compared with the gold standard, micro-CT. Thirty-eight condyles showed a significant (P〈O.05) mean bone volume decrease of 26.4%_ 11.4% (502.9 mm3+ 268.1 mm3). No significant effects of side, sex or age were found. Good to excellent (ICC〉 0.6) intra- and inter-observer reliability was observed for both MSCT and CBCT. Moreover, the bone segmentation accuracy was less than one voxel (0.4 mm) for MSCT (0.3 mm __. 0.2 mm) and CBCT (0.4 mm _ 0.3 mm), thus indicating the clinical potential of this method for objective follow-up in pathological condylar resorption.
文摘Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral computed tomography (MSCT) guidance before the procedure. Methods: A series of 58 consecutive patients with refractory paroxysmal AF were enrolled to undergo segmental radiofrequency ablation ofPV ostia. The 36 male and 22 female patients with mean age of (57.4±9.5) (32-79) years and no obvious organic heart disease. Before ablation, patients received MSCT to generate 3-dimentional image of the left atrium (LA) and proximal PVs. Patients then underwent segmental radiofrequency ablation ofPV ostia using PV circular mapping catheter manipulated several times to ensure complete isolation between PVs and LA. Results: No complications occurred during the procedure. One patient developed delayed cardiac tamponade, which was drained percutaneously. The mean follow-up time was (17.1±9.3) months. Forty-one patients (95%) experienced improved quality of life one month after the procedure. Thirty-six patients (83%) showed stable sinus rhythm, while 10 patients (23%) required additional anti-arrhythmic drugs. AF returned≥1 time in 6 (14%) patients who underwent anti-arrhythmic drug therapy, but the number of episodes was less than that before the procedure. However, one patient experienced recurrent episodes of atrial flutter. Conclusion: It is safe and effective to perform segmental radiofrequency ablation of PV ostia for patients with refractory paroxysmal AF using MSCT guidance mappening.
文摘BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of transformation into malignant tumors is as high as 20%-30%.AIM To investigate the value of multi-slice spiral computed tomography(MSCT)in the differential diagnosis of GST and benign gastric polyps,and GST risk stratification assessment.METHODS We included 64 patients with GST(GST group)and 60 with benign gastric polyps(control group),confirmed by pathological examination after surgery in PLA General Hospital,from January 2016 to June 2021.The differences in the MSCT imaging characteristic parameters and enhanced CT values between the two groups before surgery were compared.According to the National Institutes of Health’s standard,GST is divided into low-and high-risk groups for MSCT imaging characteristic parameters and enhanced CT values.RESULTS The incidences of extraluminal growth,blurred boundaries,and ulceration in the GST group were significantly higher than those in the control group(P<0.05).The CT values and enhanced peak CT values in the arterial phase in the CST group were higher than those in the control group(P<0.05).The MSCT differential diagnosis of GST and gastric polyp sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and areas under the curve(AUCs)were 73.44%,83.33%,26.56%,16.67%,0.784,respectively.The receiver operating characteristic curves were plotted with the arterial CT value and enhanced peak CT value,with a statistical difference.The results showed that the sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of arterial CT in the differential diagnosis of GST and gastric polyps were 80.18%,62.20%,19.82%,37.80%,and 0.710,respectively.The sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of the enhanced peak CT value in the differential diagnosis of GST and gastric polyps were 67.63%,60.40%,32.37%,39.60%,and 0.710,respectively.The incidence of blurred lesion boundaries and ulceration in the high-risk group was significantly higher than that in the low-risk group(P<0.05).The arterial phase and enhanced peak CT values in the high-risk group were significantly higher than those in the low-risk group(P<0.05).CONCLUSION Presurgical MSCT examination has important value in the differential diagnosis of GST and gastric benign polyps and can effectively evaluate the risk grade of GST patients.
文摘BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can clearly demonstrate the 3D space of fractures and detect fractures at a higher rate.AIM To investigate the clinical value of multi-slice spiral CT 3D reconstruction in the diagnosis of unstable pelvic fractures in the elderly as well as the effect of less invasive stabilization.METHODS A total of 86 patients with unstable pelvic fractures treated between March 2016 and March 2019 underwent femoral supracondylar bone traction before surgery.Pelvic radiography and multi-row spiral CT were performed successively once the patient’s vital signs and hemodynamic indices were stable.Secondary processing of the original data was performed to obtain 3D reconstruction images and determine the vertical displacement of the pelvis.After basic or complete reduction,minimally invasive internal fixation using hollow lag screws was performed.The detection rates of fracture location and classification by X-ray and CT reconstruction were compared.Patients were divided into two groups according to the presence or absence of preoperative 3D reconstruction to compare postoperative reduction,wound healing time,fracture healing time,hospitalization time,visual analog scale(VAS)score,poor internal fixation,and functional recovery.RESULTS The diagnostic coincidence rates of X-rays for pubic symphysis,ilium wing,sacroiliac periarticular,and sacral fractures were lower than those of CT reconstruction.The coincidence rate of CT reconstruction in the clinical classification of pelvic fractures was 100%,whereas 11 cases were misdiagnosed by X-ray;the total coincidence rate was 87.21%.The total excellent and good rates of postoperative reduction were significantly higher in the study group than in the control group(P<0.05).The wound healing,fracture healing,and hospitalization times were significantly shorter in the study group than in the control group(P<0.05).The VAS scores decreased in both groups postoperatively and were lower in the study group than in the control group(P<0.05).The total incidence of poor postoperative internal fixation was significantly lower in the study group than in the control group(P<0.05).The overall rate of postoperative functional recovery was significantly higher in the study group than in the control group(P<0.05).CONCLUSION Multi-slice spiral CT has high guiding significance for the diagnosis,classification,and treatment of unstable pelvic fractures in the elderly.Preoperative 3D reconstruction can effectively shorten the operation time and promote fracture healing,while minimally invasive internal fixation can effectively reduce pain and promote functional recovery of fracture sites,making it worthy of clinical application.
文摘BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enhance clinical treatment of the disease.AIM To explore the role of computed tomography(CT)recurrence in evaluating EGC after ESD treatment.METHODS We retrospectively recruited patients from our endoscopy department,between January 2002 and December 2015,and analyzed their basic characteristics,including symptoms,CT results,and results of endoscopy with biopsy,among others.RESULTS Among a total of 2150 patients EGC patients surveyed,1362 met our inclusion and exclusion criteria and were therefore enrolled in our study.The cohort’s sensitivity of CT for recurrent GC and specificity were 44.22%and 43.86%,respectively,with negative and positive predictive values of 40.15%(275/685)and 48.01%(325/677),respectively.The area under the curve of arterial and venous CT values for recurrent EGC were 0.545,and 0.604,respectively.Receiver operating characteristic curve revealed no statistically significant differences between arterial and venous CT values for recurrent EGC.CONCLUSION Enhanced CT has superior diagnostic efficacy,but less accuracy,compared to gold standard techniques in patients with recurrent EGC.
文摘Objective:To investigate the value of tumor markers in colorectal cancer with multi-slice spiral CT in the diagnosis of elderly colorectal cancer.Methods:From January 2016 to September 2017 year period, 73 elderly patients with colorectal cancer treated in our hospital were selected as observation group;64 elderly patients with intestinal benign lesions were selected as control group during the same period. Serum samples were collected to detect contents of CEA, CA72-4, CA19-9 and CYFRA21-1 by Roche luminous immunoassay analyzer, and multi slice spiral CT was used.Results:Serum levels of CEA, CA72-4, CA19-9 and CYFRA21-1 levels of the observation group were significantly higher than that of the control group;the positive rate of CEA, CA72-4, CA19-9, CYFRA21-1 and their combined detection were all significantly higher than that of the control group;positive rate of MSCT in the observation group was higher than the control group;positive rates of tumor markers combining with MSCT examination of colorectal cancer were higher than that of combined detection of tumor markers and MSCT examination;but there was no significant difference in positive rate of combined detection of tumor markers and the positive rate of MSCT detection of colorectal cancer.Conclusion:Colorectal cancer tumor markers combined with multi-slice spiral CT in the diagnosis of colorectal cancer in elderly has important research value, can significantly improve the positive rate of diagnosis.
文摘AIM: To establish models of portal vein occlusion of hepatic VX2 tumor in rabbits and to evaluate the value of multi-slice CT. METHODS: Forty New Zealand rabbits were divided into 4 groups according to digital table: Immediate group (group A; transplantation of tumor immediately after the portal vein occlusion), 3-wk group (group B; transplantation of tumor at 3 wk after the portal vein occlusion), negative control group (group C) and positive control group (group D), 10 rabbits in each group. Hepatic VX2 tumor was transplanted with abdominalembedding innoculation immediately after the portal vein occlusion and at 3 wk after the portal vein occlusion. Meanwhile, they were divided into negative control group (Left external branch of portal vein was occluded by sham-operation, and left exite was embedded and inoculated pseudoly) and positive control group (Transplanted tumor did not suffer from the portal vein occlusion). All rabbits were scanned with multi-slice CT. RESULTS: All 40 animals were employed in the final analysis without death. Tumor did not grow in both immediate group and 3-wk group. In 3-wk group, left endite was atrophied and growth of tumor was inhibited. The maximal diameter of tumor was significantly smaller than that in positive control group (2.55±0.46 vs 3.59±0.37 cm, t = 5.57, P 〈 0.001). Incidences of metastasis in the liver and lung were lower in 3-wk group than those in positive control group (10% vs 400, and 90% vs 100%, respectively). The expression intensities of the vascular endothelium growth factor (VEGF) in groups A, B, C and D were 0.10±0.06, 0.66±0.21, 0.28±0.09 and 1.48±0.32, respectively. VEGF expression level in the test group A was significantly lower than that in the negative control group C (t = 5.07; P 〈 0.001).In addition, VEGF expression in the test group B was significantly lower than that in the positive control group D (t = 6.38; P 〈 0.001). Scanning with multi-slice CT showed that displaying rate of hepatic artery branches was obviously lower in grade Ⅲ(40%) than that in grade Ⅰ(70%) and Ⅱ(100%) (P 〈 0.05); but there was no significant difference in displaying rate of the portal vein at various grades. Values of blood flow (BF) of the liver, blood volume (BV), mean transit time (MTT) and permeability of vascular surface (PS) were lower in the immediate group and 3-wk group than those in control groups, but values of hepatic arterial fraction (HAF) were increased. Significant positive correlations were existed between BF and BV (r = 0.905, P 〈 0.01), and between BF and PS (r = 0.967, P 〈 0.01), between BV and PS (r = 0.889, P 〈 0.01). A significant negative correlation existed between PV and HAF (r = -0.768, P 〈 0.01), between PS and HAF (r = -0.557, P 〈 0.01). The values of BF, BV and PS had a positive correlation with VEGF (rBF = 0.842, rBV = 0.579, rPS = 0.811, P 〈 0.01) . However, there was no significant correlation between the values of MTT and HAF and the VEGF expression (rMTt = 0.066, rHAF = -0.027). CONCLUSION: Ligating the left external branch of portal vein is an ideal way to establish models of portal vein occlusion in rabbits with hepatic VX2 tumor. Multi slice CT plays a key role in evaluating effect of portal vein occlusion.
文摘Transcatheter aortic valve implantation(TAVI) has been shown in improve outcome of severe aortic stenosis(AS) patients, deemed surgical high-risk or inoperable, and has grown popular in the past decade. The procedure requires accurate prior planning, and demands an integration of a "Heart Team" consisted from cardiac surgeons, interventional cardiologists, and imaging experts. The role of cardiac imaging and especially multi-slice computerized tomography(MSCT) has been a mainstay of pre-evaluation of severe AS patients that allows to accurately depict and size the cardiac and vascular structures, and has become the primary tool for procedural planning. This article is aimed to evaluate current uses of MSCT in severe AS patients undergoing TAVI, delineate the various measurements derived from this modality and review current literature regarding it's advantages over other techniques.
文摘Most of coal is produced from open-cut mines in Southeast Asian countries. However, the conditions of their surface mines are worsening each year: the stripping ratio is increasing, approaching economic ratio and the regulation of environmental protection. To meet the demand for coal, underground mines have to be developed in the near future. Under these circumstances, the development of new coal mines from open-cut highwalls are being planned in Southeast Asian Countries. Moreover, some of the Southeast Asian mines have thick coal seams. However, if the conventional mining systems and designs introduced in US, Australia and European Countries are applied, several geotechnical issues can be expected due to the mines' weak geological conditions. From these backgrounds, this paper proposed a punch multi-slice mining system with stowing for thick coal seam under weak geological conditions and discussed its applicability and suitable design by means of numerical analysis.
文摘Objective:To analyze the value of multislice spiral CT in the diagnosis and resectability of pancreatic cancer.Method:56 patients with pancreatic cancer treated in our hospital from January 2018 to October 2019 were selected as the research subjects.All patients underwent multi-phase scanning by multislice spiral CT.According to the results of the images,observe whether the pancreatic cancer has affected the blood vessels surrounding the pancreas,evaluate the resectability based on the results of the examination,and analyze the final results of the operation which was taken as the standard.Results:all the 56 cases presented slightly low density or equal density,and 28 cases had complete outline.Multi-slice spiral assessment of patients’vascular invasion types found that 192 branches can be resected with 70 branches cannot;Multi-slice spiral assessment of the main arterial and venous invasion grades around the pancreas of the patients found that 212 branches can be resected with 50 branches cannot;Multi-slice spiral CT was used to evaluate the resectability of pancreatic cancer compared with surgical results.The accuracy of resectable types of vascular invasion was 72.52%;the accuracy of resectable vascular invasion grades was 79.39%.Conclusion:the application of multi-slice spiral CT in the diagnosis of pancreatic cancer can provide a clear understanding of the condition of vascular invasion and distant metastasis,and the accuracy of assessing resection can reach more than 70.00%,which provides a reference for clinical application.
文摘Objective:To compare and analyze the clinical diagnostic value of multi-slice spiral CT and enhanced MRI for primary liver cancer(PLC),and to summarize the imaging findings.Methods:The research subjects in this article were 50 patients with PLC who were admitted to our hospital from 2017 April to 2018 September.After the patients were admitted,they were examined by multi-slice spiral CT and enhanced MRI scanning,and the pathological diagnosis results were followed up.Relevant information was reviewed and analyzed.Results:The detection rate of multi-slice spiral CT was higher than that of MRI in the portal venous phase lesion detection.The difference was statistically significant(P<0.05).The detection rate of lesions in the arterial phase and delayed phase was not statistically significant(P>0.05);the diagnostic accuracy of multi-slice spiral CT was 85.96%,and the diagnostic accuracy of enhanced MRI scanning was 91.11%,which was not statistically significant(P>0.05).MRI scans showed the capsules of primary liver cancer better than CT,but the difference was not statistically significant(P>0.05).Conclusion:In conclusion,both multi-slice spiral CT and enhanced MRI can be used for the effective diagnosis of primary liver cancer intrahepatic lesions.The diagnostic value of the two is equivalent,but enhanced MRI has a slightly higher diagnostic accuracy and can be used as the preferred method.
文摘Background Many studies have shown that cancer cell differentiation and microvascular invasion play a principle role in cancer progression and metastasis, and non-invasive imaging techniques such as CT, MRI and US assessing the differentiation and the surgical resectibility and the prognosis of cancers are now of great importance. This study aimed to explore the correlation of triple-phase multi-slice CT scan with the histological differentiation and intratumor microvascular/lymphatic invasion of progressive gastric cancer.Methods The present study included 64 patients with gastric cancer, all of whom underwent routinal and dual-phase contrast enhancement multi-slice CT examinations of the upper abdomen before surgery. The post-operative specimens were used for determination of histological differentiation, cancer cell invasion of intratumoral microvascular/lyrnphatic vessel identified by CD34 and D2-40 expression. Correlations between contrast enhancement ratio (CER) of triple-phase multi-slice CT scan in gastric cancer and histological differentiation as well as intraturnoral microvascular/lymphatic invasion were compared and analyzed.Results There was a significant correlation between CER of triple-phase CT scan in gastric cancer and tumor histological differentiation (P〈0.05). CER of the arterial phase in gastric cancer with intratumoral microvascular invasion was significantly higher than that without invasion (0.61±0.28 vs. 0.46±0.14, P 〈0.05); CER of the arterial-parenchymal phase was significantly lower in gastric cancer with intratumoral microvascular invasion than that without invasion (1.81±0.39 vs. 2.28±0.80, P〈0.05). However, CER of the parenchymal phase in gastric cancer with intratumoral lymphatic invasion was significantly higher than that without invasion (1.25±0.57 vs. 1.00±0.35, P〈0.05).Conclusions CER of triple-phase multi-slice CT scan in gastric cancer is closely correlated with intratumoral microvascular and lymphatic invasion, and also could be used as a marker for histological differentiation.
文摘Background This study aimed to investigate multi-slice CT contrast-enhanced presentation of gastric cancer and its correlation with histo-differentiation and p53 and P-glycoprotein (P-gp) expression. Methods Sixty-six patients with gastric cancer in the present study underwent a multi-slice CT preoperative routine and dual-phase contrast-enhanced examination of the upper abdomen; postoperative specimens were used to determine histo-differentiation and the expression of p53 and P-gp. The correlation of multi-slice CT contrast-enhanced presentation with histo-differentiation and expression of p53 and P-gp was analyzed. Results The dual-phase contrast-enhanced ratio (CER) was not correlated with the histo-differentiation of gastric cancer (P 〉0.05). Positive expression of p53 and P-gp was significantly higher in the cases of layered or heterogeneous enhancement than in the cases of homogenous enhancement (P 〈0.05). Positive expression of p53 was also correlated with the arterial phase CER, tumor size and lymph node metastasis (P 〈0.05), but not with infiltration thickness of the gastric wall, nor was it correlated with the portal phase CER (P 〉0.05). Positive expression of P-gp was only correlated with the portal phase CER (P=0.005). Conclusions Differently enhanced pattern and CER of the arterial and portal phase in gastric cancer correlate with its different histo-differentiation and expression of p53 and P-gp respectively. In addition, tumor size and lymph node metastasis of gastric cancer relate to the expression of p53.
文摘Background Multi-slice CT liver perfusion has been widely used in experimental studies of hemodynamic changes in liver lesions, and is usually performed as an adjunct to a conventional CT examination because of its high temporal and spatial resolution, simple protocol, good reproducibility, and ability to measure hemodynamic changes of liver tissues at the capillary level. Experimental rat models, especially those of induced liver cancer, are often used in studies of hemodynamic changes in liver cancer. Carcinogenesis in rats has a similar pathological progression and characteristics resembling those in human liver cancer; as a result, rat models are often used as ideal animal models in the study of human liver cancer. However, liver perfusion imaging in rats is difficult to perform, because rats' livers are so small that different concentrations, flow rates, and dose of contrast agents during the CT perfusion scanning can influence the quality of liver perfusion images in rats. The purpose of this study, therefore, was to investigate the optimal scan protocol for the imaging of hepatic perfusion using a deconvolution mathematical method in rats by comparing the results of rats in different injection conditions of the contrast agent, including concentration, rate and time. Methods Plain CT scan conditions in eighty 2-month-old male Wistar rats were 5.0 mm slice thickness, 5.0 mm interval, 1.0 pitch, 120 kV tube voltage, 60 mA tube current, 512x512 matrix, and FOV 9.6 cm. Perfusion scanning was carried out with different concentrations of diatrizoate (19%, 38%, 57%, and 76%), different injection rates (0.3 and 0.5 ml/s), and different injection times (1, 2-3, 4-5, and 6 seconds). The above conditions were randomly matched and adjusted to determine the best perfusion scan protocol. Three-phase contrast-enhanced scanning was performed after CT perfusion. Histological examination of the liver tissues with hematoxylin and eosin stains was done after CT scanning. Results When the concentration of the contrast agent was 19% or 38%, no pseudo-color map was created. The viscosity increased when the concentration of the contrast agent was 76%; so it is difficult to inject the contrast agent at such a high concentration. Also no pseudo-color map was generated when the injection time was short (1, 2-3, and 4-5 seconds) or the injection rate was low (0.3 ml/s). The best perfusion images and perfusion parameters were obtained during 50 seconds scanning. Each rat was given an injection of 57% diatrizoate at 0.5 mils via the tail vein using a high-pressure syringe for 6 seconds. The perfusion parameters included hepatic blood flow (HBF), hepatic blood volume (HBV), mean transit time (MTT) of the contrast agent, capillary permeability-surface area product (PS), hepatic arterial index (HAl), hepatic artery perfusion (HAP), and hepatic portal perfusion (HPP). All these parameters reflected the perfusion status of liver parenchyma in normal rats. Three phases of enhancement were modified according to the time-density curves (TDCs) of the perfusion imaging: hepatic arterial phase (7 seconds), hepatic portal venous phase (15 seconds), and a delayed phase (23-31 seconds). On examination by microscopy, the liver tissues were pathologically normal. Conclusions The appropriate protocol with multi-slice spiral CT liver perfusion reflected normal liver hemodynamics in rats. This study laid a solid foundation for further investigation of the physiological characteristics of liver cancer in a rat model, and was an important supplement to and reference for conventional contrast-enhanced CT scans.