One of the main aspects in computed tomography (CT) development is to make CT rapidly scan a large longitudinal volume with high z-axis resolution. The combination of helical scanning with multi-slice CT is a promisin...One of the main aspects in computed tomography (CT) development is to make CT rapidly scan a large longitudinal volume with high z-axis resolution. The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major challenge. Known algorithms need to derive the complementary data or work only for certain range of pitches. A reconstruction algorithm was presented that works with the direct data as well as arbitrary pitches. Filter interpolation based on the proposed method was implemented easy. The results of computer simulations under kinds of conditions for four-slice CT were presented. The proposed method can obtain higher efficiency than the conventional method.展开更多
Objective:To analyze the value of multi-slice spiral computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of carpal joint injury.Methods:A total of 130 patients with suspected wrist injuries admi...Objective:To analyze the value of multi-slice spiral computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of carpal joint injury.Methods:A total of 130 patients with suspected wrist injuries admitted to the Department of Orthopedics of our hospital from January 2023 to January 2024 were selected and randomly divided into a single group(n=65)and a joint group(n=65).The single group was diagnosed using multi-slice spiral CT,and the joint group was diagnosed using multi-slice spiral CT and magnetic resonance imaging,with pathological diagnosis as the gold standard.The diagnostic results of both groups were compared to the gold standard,and the diagnostic energy efficiency of both groups was compared.Results:The diagnostic results of the single group compared with the gold standard were significant(P<0.05).The diagnostic results of the joint group compared with the gold standard were not significant(P>0.05).The sensitivity and accuracy of diagnosis in the joint group were significantly higher than that in the single group(P<0.05).The specificity of diagnosis in the joint group was higher as compared to that in the single group(P>0.05).Conclusion:The combination of multi-slice spiral CT and MRI was highly accurate in diagnosing wrist injuries,and the misdiagnosis rate and leakage rate were relatively low.Hence,this diagnostic program is recommended to be popularized.展开更多
Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention t...Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.展开更多
Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collect...Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collected, of which 6 cases were normal, 5 cases were subjected to cirrhosis and hypertension of portal vein, 42 cases had portal tumor thrombus of hepatic cancer, and the remaining 4 cases showed lymph node enlargment in hilar of liver. All data of the patients came from conventional multi-slice spiral CT double phase of liver. Contrast media was 1.5–2 ml/kg with the injection rate being 2.5–3 ml/s. Axis and 3D portography was analyzed and compared in 42 cases of portal tumor thrombus of hepatic cancer.Results: According to portal tumor thrombus position, 42 cases were fallen into three categories: left (13 cases), right (20 cases), main (9 cases) of potal vein. There was no difference between axis and 3D portography in displaying portal tumor thrombus of hepatic cancer (P>0.05), but 3D portography showing collateral branches was better than axis portography after main portal vein thrombus.Conclusion: Multi-slice spiral CT 3D portography can display the position and types of portal tumor thrombus of hepatic cancer. 3D combined with axis portography can better evaluate the portal tumor thrombus of hepatic cancer and guide to select the therapies. Key words portal vein - tumor thrombus - multi-slice CT - 3 dimension imaging展开更多
BACKGROUND: During the past years, the number of liver transplantation has increased greatly, but the number of available organs has not increased. In view of the critical shortage of organs, the indications for livin...BACKGROUND: During the past years, the number of liver transplantation has increased greatly, but the number of available organs has not increased. In view of the critical shortage of organs, the indications for living-related liver transplantation (LRLT) have broadened since experience with the procedure has been achieved. This study was undertaken to assess the value of multi-slice spiral CT (MSCT) angiography in evaluating the hepatic arterial and veinous anatomy of potential donors for LRLT. METHODS: MSCT was performed after intravenous injection of contrast material at 3 ml/s. The total dose was calculated as 2 ml/kg. Twenty LRLT donors (2 men and 18 women) were subjected to MSCT angiography of hepatic blood vessels. These were generated by volume rendering and maximum intensity projection, while curved planar reformation was added in 5 patients. RESULTS: We identified 10 important hepatic vascular variants in 9 of the 20 donors (4 arterial, 4 venous, and 2 portal venous variants). In hepatic arterial variants, two had a replaced right hepatic artery arising from the superior mesenteric artery, an accessory right hepatic artery from the superior mesenteric artery and a replaced left hepatic artery arising from the left gastric artery. In hepatic venous variants, three had an accessory inferior right hepatic vein and one had two accessory inferior right hepatic veins. In hepatic portal venous variants, two had trifurcation of the main portal vein. CONCLUSIONS: As a non-invasive and reliable method, MSCT angiography is of value in the clinical evaluation of LRLT donors. MSCT angiography should be recommended as a routine preoperative examination for potential LRLT donors.展开更多
Objective: To assess the value of helical CT in the di- agnosis of liver diseases. Methods: 59 patients with different liver diseases were examined by two-phase or multi-phase dynamic helical CT. Results: Small hepato...Objective: To assess the value of helical CT in the di- agnosis of liver diseases. Methods: 59 patients with different liver diseases were examined by two-phase or multi-phase dynamic helical CT. Results: Small hepatocellular carcinoma showed a higher density in the arterial phase, and a lower den- sity in the portal vein phase. Large hepatic carcino- ma showed a mixed pattern of higher-density in the arterial phase, and a lower density in the portal vein phase. Metastasis carcinoma showed an 'oxeye sign' in the portal vein phase. Hemangioma was not obvi- ously enhanced in the early arterial phase, marginal- ly enhanced in the arterial phase, and equally-densed in the balanced phase. Conclusion: Two-phase helical CT is of value in im- proving the detection rate of or determining the fea- tures of hepatic diseases by two-phase helical dyna- mic scan (2.0-3.0 ml/s speed, and delay time 25- 30 s and 70-85 s).展开更多
Objective:To investigate the value of tumor markers in colorectal cancer with multi-slice spiral CT in the diagnosis of elderly colorectal cancer.Methods:From January 2016 to September 2017 year period, 73 elderly pat...Objective:To investigate the value of tumor markers in colorectal cancer with multi-slice spiral CT in the diagnosis of elderly colorectal cancer.Methods:From January 2016 to September 2017 year period, 73 elderly patients with colorectal cancer treated in our hospital were selected as observation group;64 elderly patients with intestinal benign lesions were selected as control group during the same period. Serum samples were collected to detect contents of CEA, CA72-4, CA19-9 and CYFRA21-1 by Roche luminous immunoassay analyzer, and multi slice spiral CT was used.Results:Serum levels of CEA, CA72-4, CA19-9 and CYFRA21-1 levels of the observation group were significantly higher than that of the control group;the positive rate of CEA, CA72-4, CA19-9, CYFRA21-1 and their combined detection were all significantly higher than that of the control group;positive rate of MSCT in the observation group was higher than the control group;positive rates of tumor markers combining with MSCT examination of colorectal cancer were higher than that of combined detection of tumor markers and MSCT examination;but there was no significant difference in positive rate of combined detection of tumor markers and the positive rate of MSCT detection of colorectal cancer.Conclusion:Colorectal cancer tumor markers combined with multi-slice spiral CT in the diagnosis of colorectal cancer in elderly has important research value, can significantly improve the positive rate of diagnosis.展开更多
AIM: To establish models of portal vein occlusion of hepatic VX2 tumor in rabbits and to evaluate the value of multi-slice CT. METHODS: Forty New Zealand rabbits were divided into 4 groups according to digital table...AIM: To establish models of portal vein occlusion of hepatic VX2 tumor in rabbits and to evaluate the value of multi-slice CT. METHODS: Forty New Zealand rabbits were divided into 4 groups according to digital table: Immediate group (group A; transplantation of tumor immediately after the portal vein occlusion), 3-wk group (group B; transplantation of tumor at 3 wk after the portal vein occlusion), negative control group (group C) and positive control group (group D), 10 rabbits in each group. Hepatic VX2 tumor was transplanted with abdominalembedding innoculation immediately after the portal vein occlusion and at 3 wk after the portal vein occlusion. Meanwhile, they were divided into negative control group (Left external branch of portal vein was occluded by sham-operation, and left exite was embedded and inoculated pseudoly) and positive control group (Transplanted tumor did not suffer from the portal vein occlusion). All rabbits were scanned with multi-slice CT. RESULTS: All 40 animals were employed in the final analysis without death. Tumor did not grow in both immediate group and 3-wk group. In 3-wk group, left endite was atrophied and growth of tumor was inhibited. The maximal diameter of tumor was significantly smaller than that in positive control group (2.55±0.46 vs 3.59±0.37 cm, t = 5.57, P 〈 0.001). Incidences of metastasis in the liver and lung were lower in 3-wk group than those in positive control group (10% vs 400, and 90% vs 100%, respectively). The expression intensities of the vascular endothelium growth factor (VEGF) in groups A, B, C and D were 0.10±0.06, 0.66±0.21, 0.28±0.09 and 1.48±0.32, respectively. VEGF expression level in the test group A was significantly lower than that in the negative control group C (t = 5.07; P 〈 0.001).In addition, VEGF expression in the test group B was significantly lower than that in the positive control group D (t = 6.38; P 〈 0.001). Scanning with multi-slice CT showed that displaying rate of hepatic artery branches was obviously lower in grade Ⅲ(40%) than that in grade Ⅰ(70%) and Ⅱ(100%) (P 〈 0.05); but there was no significant difference in displaying rate of the portal vein at various grades. Values of blood flow (BF) of the liver, blood volume (BV), mean transit time (MTT) and permeability of vascular surface (PS) were lower in the immediate group and 3-wk group than those in control groups, but values of hepatic arterial fraction (HAF) were increased. Significant positive correlations were existed between BF and BV (r = 0.905, P 〈 0.01), and between BF and PS (r = 0.967, P 〈 0.01), between BV and PS (r = 0.889, P 〈 0.01). A significant negative correlation existed between PV and HAF (r = -0.768, P 〈 0.01), between PS and HAF (r = -0.557, P 〈 0.01). The values of BF, BV and PS had a positive correlation with VEGF (rBF = 0.842, rBV = 0.579, rPS = 0.811, P 〈 0.01) . However, there was no significant correlation between the values of MTT and HAF and the VEGF expression (rMTt = 0.066, rHAF = -0.027). CONCLUSION: Ligating the left external branch of portal vein is an ideal way to establish models of portal vein occlusion in rabbits with hepatic VX2 tumor. Multi slice CT plays a key role in evaluating effect of portal vein occlusion.展开更多
Objective:To analyze the value of multislice spiral CT in the diagnosis and resectability of pancreatic cancer.Method:56 patients with pancreatic cancer treated in our hospital from January 2018 to October 2019 were s...Objective:To analyze the value of multislice spiral CT in the diagnosis and resectability of pancreatic cancer.Method:56 patients with pancreatic cancer treated in our hospital from January 2018 to October 2019 were selected as the research subjects.All patients underwent multi-phase scanning by multislice spiral CT.According to the results of the images,observe whether the pancreatic cancer has affected the blood vessels surrounding the pancreas,evaluate the resectability based on the results of the examination,and analyze the final results of the operation which was taken as the standard.Results:all the 56 cases presented slightly low density or equal density,and 28 cases had complete outline.Multi-slice spiral assessment of patients’vascular invasion types found that 192 branches can be resected with 70 branches cannot;Multi-slice spiral assessment of the main arterial and venous invasion grades around the pancreas of the patients found that 212 branches can be resected with 50 branches cannot;Multi-slice spiral CT was used to evaluate the resectability of pancreatic cancer compared with surgical results.The accuracy of resectable types of vascular invasion was 72.52%;the accuracy of resectable vascular invasion grades was 79.39%.Conclusion:the application of multi-slice spiral CT in the diagnosis of pancreatic cancer can provide a clear understanding of the condition of vascular invasion and distant metastasis,and the accuracy of assessing resection can reach more than 70.00%,which provides a reference for clinical application.展开更多
In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection trun...In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection truncation. The reason is that the ramp filter is global. To restrain the truncation artifacts, an approximate reconstruction formula is proposed based on the Derivative-Hilbert-Backprojection(DHB) framework. In the method, the first order derivative filter is followed by the Hilbert transform. Since the filtered projection values are almost zero by the first order derivative filter, the following Hilbert transform has little influence on the projection values, even though the projections are laterally truncated. The proposed method has two main advantages. First, it has comparable computational efficiency and image quality as well as the conventional helical FDK algorithm for non-truncated projections. The second advantage is that images can be reconstructed with acceptable quality and much lower computational cost in comparison to the Laplace operator based algorithm in cases with truncated projections. To point out the advantages of our method, simulations on the computer and real data experiments on our laboratory industrial cone-beam CT are conducted. The simulated and experimental results demonstrate that the method is feasible for image reconstruction in the case of projection truncation.展开更多
Objective:To compare and analyze the clinical diagnostic value of multi-slice spiral CT and enhanced MRI for primary liver cancer(PLC),and to summarize the imaging findings.Methods:The research subjects in this articl...Objective:To compare and analyze the clinical diagnostic value of multi-slice spiral CT and enhanced MRI for primary liver cancer(PLC),and to summarize the imaging findings.Methods:The research subjects in this article were 50 patients with PLC who were admitted to our hospital from 2017 April to 2018 September.After the patients were admitted,they were examined by multi-slice spiral CT and enhanced MRI scanning,and the pathological diagnosis results were followed up.Relevant information was reviewed and analyzed.Results:The detection rate of multi-slice spiral CT was higher than that of MRI in the portal venous phase lesion detection.The difference was statistically significant(P<0.05).The detection rate of lesions in the arterial phase and delayed phase was not statistically significant(P>0.05);the diagnostic accuracy of multi-slice spiral CT was 85.96%,and the diagnostic accuracy of enhanced MRI scanning was 91.11%,which was not statistically significant(P>0.05).MRI scans showed the capsules of primary liver cancer better than CT,but the difference was not statistically significant(P>0.05).Conclusion:In conclusion,both multi-slice spiral CT and enhanced MRI can be used for the effective diagnosis of primary liver cancer intrahepatic lesions.The diagnostic value of the two is equivalent,but enhanced MRI has a slightly higher diagnostic accuracy and can be used as the preferred method.展开更多
To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 200...To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 2002 and May 2004 in the study including six cases with fractures on axis body,five on odontoid process and 10 on axis body and odontoid process.All cases received X-ray plain film,helical CT scanning,multi-planar reformatting(MPR) and VRT.Results Screw fixation through axis body and massa lateralis atlantis was performed in 10 cases and that through axis body and odontoid process in 11.VRT could clearly display full aperture of screw orbit,location of screw and angle of fixation and hence was superior to X-ray plain film and MPR.Multi-angle VRT displayed asymmetrical space of odontoid process and massa lateralis atlantis in four cases and medial deviation of 2~5 mm of half screw in screw fixation through axis body and massa lateralis atlantis in six.Conclusion VRT can eliminate false shadow of fixation screw,clearly display full aperture of screw orbit and hence supply improtant imaging evidence for post-operative evaluation of screw fixation of axis fractures.7 refs,1 fig,1 tab.展开更多
文摘One of the main aspects in computed tomography (CT) development is to make CT rapidly scan a large longitudinal volume with high z-axis resolution. The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major challenge. Known algorithms need to derive the complementary data or work only for certain range of pitches. A reconstruction algorithm was presented that works with the direct data as well as arbitrary pitches. Filter interpolation based on the proposed method was implemented easy. The results of computer simulations under kinds of conditions for four-slice CT were presented. The proposed method can obtain higher efficiency than the conventional method.
文摘Objective:To analyze the value of multi-slice spiral computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of carpal joint injury.Methods:A total of 130 patients with suspected wrist injuries admitted to the Department of Orthopedics of our hospital from January 2023 to January 2024 were selected and randomly divided into a single group(n=65)and a joint group(n=65).The single group was diagnosed using multi-slice spiral CT,and the joint group was diagnosed using multi-slice spiral CT and magnetic resonance imaging,with pathological diagnosis as the gold standard.The diagnostic results of both groups were compared to the gold standard,and the diagnostic energy efficiency of both groups was compared.Results:The diagnostic results of the single group compared with the gold standard were significant(P<0.05).The diagnostic results of the joint group compared with the gold standard were not significant(P>0.05).The sensitivity and accuracy of diagnosis in the joint group were significantly higher than that in the single group(P<0.05).The specificity of diagnosis in the joint group was higher as compared to that in the single group(P>0.05).Conclusion:The combination of multi-slice spiral CT and MRI was highly accurate in diagnosing wrist injuries,and the misdiagnosis rate and leakage rate were relatively low.Hence,this diagnostic program is recommended to be popularized.
文摘Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.
文摘Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collected, of which 6 cases were normal, 5 cases were subjected to cirrhosis and hypertension of portal vein, 42 cases had portal tumor thrombus of hepatic cancer, and the remaining 4 cases showed lymph node enlargment in hilar of liver. All data of the patients came from conventional multi-slice spiral CT double phase of liver. Contrast media was 1.5–2 ml/kg with the injection rate being 2.5–3 ml/s. Axis and 3D portography was analyzed and compared in 42 cases of portal tumor thrombus of hepatic cancer.Results: According to portal tumor thrombus position, 42 cases were fallen into three categories: left (13 cases), right (20 cases), main (9 cases) of potal vein. There was no difference between axis and 3D portography in displaying portal tumor thrombus of hepatic cancer (P>0.05), but 3D portography showing collateral branches was better than axis portography after main portal vein thrombus.Conclusion: Multi-slice spiral CT 3D portography can display the position and types of portal tumor thrombus of hepatic cancer. 3D combined with axis portography can better evaluate the portal tumor thrombus of hepatic cancer and guide to select the therapies. Key words portal vein - tumor thrombus - multi-slice CT - 3 dimension imaging
文摘BACKGROUND: During the past years, the number of liver transplantation has increased greatly, but the number of available organs has not increased. In view of the critical shortage of organs, the indications for living-related liver transplantation (LRLT) have broadened since experience with the procedure has been achieved. This study was undertaken to assess the value of multi-slice spiral CT (MSCT) angiography in evaluating the hepatic arterial and veinous anatomy of potential donors for LRLT. METHODS: MSCT was performed after intravenous injection of contrast material at 3 ml/s. The total dose was calculated as 2 ml/kg. Twenty LRLT donors (2 men and 18 women) were subjected to MSCT angiography of hepatic blood vessels. These were generated by volume rendering and maximum intensity projection, while curved planar reformation was added in 5 patients. RESULTS: We identified 10 important hepatic vascular variants in 9 of the 20 donors (4 arterial, 4 venous, and 2 portal venous variants). In hepatic arterial variants, two had a replaced right hepatic artery arising from the superior mesenteric artery, an accessory right hepatic artery from the superior mesenteric artery and a replaced left hepatic artery arising from the left gastric artery. In hepatic venous variants, three had an accessory inferior right hepatic vein and one had two accessory inferior right hepatic veins. In hepatic portal venous variants, two had trifurcation of the main portal vein. CONCLUSIONS: As a non-invasive and reliable method, MSCT angiography is of value in the clinical evaluation of LRLT donors. MSCT angiography should be recommended as a routine preoperative examination for potential LRLT donors.
文摘Objective: To assess the value of helical CT in the di- agnosis of liver diseases. Methods: 59 patients with different liver diseases were examined by two-phase or multi-phase dynamic helical CT. Results: Small hepatocellular carcinoma showed a higher density in the arterial phase, and a lower den- sity in the portal vein phase. Large hepatic carcino- ma showed a mixed pattern of higher-density in the arterial phase, and a lower density in the portal vein phase. Metastasis carcinoma showed an 'oxeye sign' in the portal vein phase. Hemangioma was not obvi- ously enhanced in the early arterial phase, marginal- ly enhanced in the arterial phase, and equally-densed in the balanced phase. Conclusion: Two-phase helical CT is of value in im- proving the detection rate of or determining the fea- tures of hepatic diseases by two-phase helical dyna- mic scan (2.0-3.0 ml/s speed, and delay time 25- 30 s and 70-85 s).
文摘Objective:To investigate the value of tumor markers in colorectal cancer with multi-slice spiral CT in the diagnosis of elderly colorectal cancer.Methods:From January 2016 to September 2017 year period, 73 elderly patients with colorectal cancer treated in our hospital were selected as observation group;64 elderly patients with intestinal benign lesions were selected as control group during the same period. Serum samples were collected to detect contents of CEA, CA72-4, CA19-9 and CYFRA21-1 by Roche luminous immunoassay analyzer, and multi slice spiral CT was used.Results:Serum levels of CEA, CA72-4, CA19-9 and CYFRA21-1 levels of the observation group were significantly higher than that of the control group;the positive rate of CEA, CA72-4, CA19-9, CYFRA21-1 and their combined detection were all significantly higher than that of the control group;positive rate of MSCT in the observation group was higher than the control group;positive rates of tumor markers combining with MSCT examination of colorectal cancer were higher than that of combined detection of tumor markers and MSCT examination;but there was no significant difference in positive rate of combined detection of tumor markers and the positive rate of MSCT detection of colorectal cancer.Conclusion:Colorectal cancer tumor markers combined with multi-slice spiral CT in the diagnosis of colorectal cancer in elderly has important research value, can significantly improve the positive rate of diagnosis.
文摘AIM: To establish models of portal vein occlusion of hepatic VX2 tumor in rabbits and to evaluate the value of multi-slice CT. METHODS: Forty New Zealand rabbits were divided into 4 groups according to digital table: Immediate group (group A; transplantation of tumor immediately after the portal vein occlusion), 3-wk group (group B; transplantation of tumor at 3 wk after the portal vein occlusion), negative control group (group C) and positive control group (group D), 10 rabbits in each group. Hepatic VX2 tumor was transplanted with abdominalembedding innoculation immediately after the portal vein occlusion and at 3 wk after the portal vein occlusion. Meanwhile, they were divided into negative control group (Left external branch of portal vein was occluded by sham-operation, and left exite was embedded and inoculated pseudoly) and positive control group (Transplanted tumor did not suffer from the portal vein occlusion). All rabbits were scanned with multi-slice CT. RESULTS: All 40 animals were employed in the final analysis without death. Tumor did not grow in both immediate group and 3-wk group. In 3-wk group, left endite was atrophied and growth of tumor was inhibited. The maximal diameter of tumor was significantly smaller than that in positive control group (2.55±0.46 vs 3.59±0.37 cm, t = 5.57, P 〈 0.001). Incidences of metastasis in the liver and lung were lower in 3-wk group than those in positive control group (10% vs 400, and 90% vs 100%, respectively). The expression intensities of the vascular endothelium growth factor (VEGF) in groups A, B, C and D were 0.10±0.06, 0.66±0.21, 0.28±0.09 and 1.48±0.32, respectively. VEGF expression level in the test group A was significantly lower than that in the negative control group C (t = 5.07; P 〈 0.001).In addition, VEGF expression in the test group B was significantly lower than that in the positive control group D (t = 6.38; P 〈 0.001). Scanning with multi-slice CT showed that displaying rate of hepatic artery branches was obviously lower in grade Ⅲ(40%) than that in grade Ⅰ(70%) and Ⅱ(100%) (P 〈 0.05); but there was no significant difference in displaying rate of the portal vein at various grades. Values of blood flow (BF) of the liver, blood volume (BV), mean transit time (MTT) and permeability of vascular surface (PS) were lower in the immediate group and 3-wk group than those in control groups, but values of hepatic arterial fraction (HAF) were increased. Significant positive correlations were existed between BF and BV (r = 0.905, P 〈 0.01), and between BF and PS (r = 0.967, P 〈 0.01), between BV and PS (r = 0.889, P 〈 0.01). A significant negative correlation existed between PV and HAF (r = -0.768, P 〈 0.01), between PS and HAF (r = -0.557, P 〈 0.01). The values of BF, BV and PS had a positive correlation with VEGF (rBF = 0.842, rBV = 0.579, rPS = 0.811, P 〈 0.01) . However, there was no significant correlation between the values of MTT and HAF and the VEGF expression (rMTt = 0.066, rHAF = -0.027). CONCLUSION: Ligating the left external branch of portal vein is an ideal way to establish models of portal vein occlusion in rabbits with hepatic VX2 tumor. Multi slice CT plays a key role in evaluating effect of portal vein occlusion.
文摘Objective:To analyze the value of multislice spiral CT in the diagnosis and resectability of pancreatic cancer.Method:56 patients with pancreatic cancer treated in our hospital from January 2018 to October 2019 were selected as the research subjects.All patients underwent multi-phase scanning by multislice spiral CT.According to the results of the images,observe whether the pancreatic cancer has affected the blood vessels surrounding the pancreas,evaluate the resectability based on the results of the examination,and analyze the final results of the operation which was taken as the standard.Results:all the 56 cases presented slightly low density or equal density,and 28 cases had complete outline.Multi-slice spiral assessment of patients’vascular invasion types found that 192 branches can be resected with 70 branches cannot;Multi-slice spiral assessment of the main arterial and venous invasion grades around the pancreas of the patients found that 212 branches can be resected with 50 branches cannot;Multi-slice spiral CT was used to evaluate the resectability of pancreatic cancer compared with surgical results.The accuracy of resectable types of vascular invasion was 72.52%;the accuracy of resectable vascular invasion grades was 79.39%.Conclusion:the application of multi-slice spiral CT in the diagnosis of pancreatic cancer can provide a clear understanding of the condition of vascular invasion and distant metastasis,and the accuracy of assessing resection can reach more than 70.00%,which provides a reference for clinical application.
基金Supported by the National High Technology Research and Development Program of China(No.2012AA011603)National Nature Science Foundation of China(No.61372172)
文摘In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection truncation. The reason is that the ramp filter is global. To restrain the truncation artifacts, an approximate reconstruction formula is proposed based on the Derivative-Hilbert-Backprojection(DHB) framework. In the method, the first order derivative filter is followed by the Hilbert transform. Since the filtered projection values are almost zero by the first order derivative filter, the following Hilbert transform has little influence on the projection values, even though the projections are laterally truncated. The proposed method has two main advantages. First, it has comparable computational efficiency and image quality as well as the conventional helical FDK algorithm for non-truncated projections. The second advantage is that images can be reconstructed with acceptable quality and much lower computational cost in comparison to the Laplace operator based algorithm in cases with truncated projections. To point out the advantages of our method, simulations on the computer and real data experiments on our laboratory industrial cone-beam CT are conducted. The simulated and experimental results demonstrate that the method is feasible for image reconstruction in the case of projection truncation.
文摘Objective:To compare and analyze the clinical diagnostic value of multi-slice spiral CT and enhanced MRI for primary liver cancer(PLC),and to summarize the imaging findings.Methods:The research subjects in this article were 50 patients with PLC who were admitted to our hospital from 2017 April to 2018 September.After the patients were admitted,they were examined by multi-slice spiral CT and enhanced MRI scanning,and the pathological diagnosis results were followed up.Relevant information was reviewed and analyzed.Results:The detection rate of multi-slice spiral CT was higher than that of MRI in the portal venous phase lesion detection.The difference was statistically significant(P<0.05).The detection rate of lesions in the arterial phase and delayed phase was not statistically significant(P>0.05);the diagnostic accuracy of multi-slice spiral CT was 85.96%,and the diagnostic accuracy of enhanced MRI scanning was 91.11%,which was not statistically significant(P>0.05).MRI scans showed the capsules of primary liver cancer better than CT,but the difference was not statistically significant(P>0.05).Conclusion:In conclusion,both multi-slice spiral CT and enhanced MRI can be used for the effective diagnosis of primary liver cancer intrahepatic lesions.The diagnostic value of the two is equivalent,but enhanced MRI has a slightly higher diagnostic accuracy and can be used as the preferred method.
文摘To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 2002 and May 2004 in the study including six cases with fractures on axis body,five on odontoid process and 10 on axis body and odontoid process.All cases received X-ray plain film,helical CT scanning,multi-planar reformatting(MPR) and VRT.Results Screw fixation through axis body and massa lateralis atlantis was performed in 10 cases and that through axis body and odontoid process in 11.VRT could clearly display full aperture of screw orbit,location of screw and angle of fixation and hence was superior to X-ray plain film and MPR.Multi-angle VRT displayed asymmetrical space of odontoid process and massa lateralis atlantis in four cases and medial deviation of 2~5 mm of half screw in screw fixation through axis body and massa lateralis atlantis in six.Conclusion VRT can eliminate false shadow of fixation screw,clearly display full aperture of screw orbit and hence supply improtant imaging evidence for post-operative evaluation of screw fixation of axis fractures.7 refs,1 fig,1 tab.