AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patie...AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patients who underwent unilateral cataract surgery,followed by implantation of rotationally asymmetric MIOLs were included.Distance and near visual acuity outcomes,intraocular aberrations,preferred reading distances,preoperative and postoperative refractive errors,mesopic and photopic pupil diameters,and the mesopic and photopic kappa angles were assessed.Patients were also administered a satisfaction survey.Photic phenomena were graded by questionnaire.Independent-related factors were identified by correlation and bivariate logistic regression analyses.RESULTS: The distance from the photopic to the mesopic pupil center(pupil center shift) was significantly associated with glare/halo symptoms [odds ratio(OR)=2.065,95% confidence interval(CI)=0.916-4.679,P=0.006] and night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007).The preoperative photopic angle kappa was significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041).The photopic angle kappa was also significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041) and with night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007) in patients implanted with rotationally asymmetric MIOLs.CONCLUSION: A large pupil center shift and misalignment between the visual and pupillary axis(angle kappa)may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs.展开更多
AIM:To evaluate clinical outcomes of unilateral implantation of a diffractive multifocal intraocular lens(IOL)in patients with contralateral monofocal IOL.METHODS:Twenty-two patients who already had implantation of a ...AIM:To evaluate clinical outcomes of unilateral implantation of a diffractive multifocal intraocular lens(IOL)in patients with contralateral monofocal IOL.METHODS:Twenty-two patients who already had implantation of a monofocal IOL in unilateral eye underwent implantation of a diffractive multifocal IOL in contralateral eye were enrolled.After 1,6,and 12 mo,uncorrected and distant corrected distant visual acuity(UCDVA and DCDVA),uncorrected and distant corrected intermediate-visual acuity(UCIVA and DCIVA),uncorrected and distant corrected near visual acuity(UCNVA and DCNVA),and contrast sensitivity were obtained.Halo/glare symptoms,spectacle dependence,and patient satisfaction were also evaluated.RESULTS:The mean age was 67.86±7.25 y and the average interval between two IOL implantations was 645.82±878.44 d.At 1 mo,binocular UCDVA was lower than 0.20 logMAR in 76%of patients(mean 0.12±0.13 logMAR),which increased to 90%by 6 and 12 mo.The binocular UCDVA was significantly better than the monocular results(P<0.05)at 1,6,and 12 mo.Additionally,UCNVA was lower than 0.40 logMAR in 82%of patients,increasing to 90%by 6 and 12 mo.Mean UCNVA in the multifocal IOL implanted eye was statistically significantly better than that in the monofocal IOL implanted eye(P<0.05)at 1,6,and 12 mo.About 5%of patients at 1 and 6 mo,reported"severe glare or halo".Patient satisfaction rates were 95%and 91%at 6 and 12 mo,respectively.CONCLUSION:Unilateral implantation of multifocal IOL in patients with a contralateral,monofocal IOL implantation results in high patient satisfaction rate,with low severe glare or halo rate during follow-up.It can represent a good option for patients who have previously had a monofocal IOL implantation regardless of two year interval duration between two IOL implantations.展开更多
AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification...AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification and implantation with the SBL-3 segmented multifocal IOL between January 1,2017 and January 31,2019 were included in this retrospective study.Preoperative biometry measurements were obtained using an IOL Master.Manifest refraction was performed at least 4 wk postoperatively.Accuracy of the eight formulas[Barrett Universal II,Emmetropia Verifying Optical(EVO),Haigis,Hill-RBF 2.0,Hoffer Q,Holladay 1,Kane,and SRK/T]was analyzed.RESULTS:Using current lens constants,all formulas exhibited errors of slight myopic shift in refractive prediction.The Barrett Universal II formula had a significantly lower median absolute error(MedAE)than did Holladay 1(P=0.02),Kane(P=0.001)and Hill-RBF 2.0(P<0.001)formulas.The Haigis formula had a lower MedAE value than did the Hill-RBF 2.0 formula(P=0.005).Differences in MedAE values among SRK/T,EVO and Hoffer Q formulas were not significant.After optimizing lens constants,the MedAE values of all formulas were reduced;significant changes were noted for EVO(P=0.022),Haigis(P=0.048);Hill-RBF 2.0(P=0.014),Holladay 1(P=0.045)and Kane(P=0.022)formulas.All formulas performed equally well after optimization of lens constants(P=0.203).CONCLUSION:All eight formulas tend to result in a myopic shift when using current lens constants.Optimized lens constants improve the accuracy of these formulas among adult Chinese patients.展开更多
Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they a...Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they are associated with a higher prevalence of dysphotopsia symptoms that is one of the most common causes of patient dissatisfaction. Neuroadaptation seems to play a major role in the optimal adaptation to multifocal IOLs. In this context, the development of strategies that facilitate the neuroadaptation process to multifocality might be an effective strategy to reduce patients' dissatisfaction. Video games have been proved to be effective for the improvement of visual acuity and for the promotion of neuroplasticity in elderly subjects and other populations with cortical-related visual impairment. This narrative review highlights the physiological potential of video games as a perceptual strategy to improve visual acuity and promote neuroplasticity in patients using multifocalIOLs, although research is still needed to confirm these benefits in this specific population, with only one comparative study to this date providing evidence of them.展开更多
Dear Editor,We write you to present a 20-year-old man with resistant spasm of accommodation without any organic cause treated with clear lens extraction(CLE)with phacoemulsification and multifocal intraocular lens(...Dear Editor,We write you to present a 20-year-old man with resistant spasm of accommodation without any organic cause treated with clear lens extraction(CLE)with phacoemulsification and multifocal intraocular lens(IOL)implantation.展开更多
AIM: To evaluate the clinical utility of automated refraction(AR) and keratometry(KR) compared with subjective or manifest refraction(MR) after cataract or refractive lens exchange surgery with implantation of ...AIM: To evaluate the clinical utility of automated refraction(AR) and keratometry(KR) compared with subjective or manifest refraction(MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X(Oculentis GmbH) refractive multifocal intraocular lens(IOL).METHODS: Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3 mo follow-up.RESULTS: Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was-1.28±0.29 diopters(D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION: We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.展开更多
·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative stu...·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs:AT LISA tri 839 MP(30 eyes;Carl Zeiss Meditec,Germany)and LS-313 MF30(30 eyes;Oculentis GmbH,Germany).Visual acuity,refractive outcome,contrast sensitivity,defocus curves,quality of vision,and optical phenomena were evaluated at3 mo postoperatively.·RESULTS:There were no statistical differences between groups in uncorrected distance visual acuity(P=0.13)and uncorrected near visual acuity(P=0.54).In contrast,uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group(P=0.02).No significant statistical between-group difference was detected in cylinder(P=0.43).Compared to trifocal group,spherical refraction and spherical equivalent in refractive multi focal group were more myopic(P<0.01).Under photopic conditions,no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree(cpd).The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group(P=0.01,P=0.034,respectively).The questionnaires of quality of vision and optical phenomena showed no differences between groups.·CONCLUSION:Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity.Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency.展开更多
BACKGROUND Asymmetric multifocal intraocular lenses(IOLs)are now widely used in the modern cataract surgery,providing a good level of visual performance over a range of distances and high postoperative patient satisfa...BACKGROUND Asymmetric multifocal intraocular lenses(IOLs)are now widely used in the modern cataract surgery,providing a good level of visual performance over a range of distances and high postoperative patient satisfaction.We report a case of improved visual quality after shifting the near segment of an asymmetrical multifocal IOL to the superotemporal placement in the dominant eye of a glaucoma patient.CASE SUMMARY A 72-year-old woman with bilateral glaucoma underwent phacoemulsification in the dominant eye(left eye)with implantation of an asymmetrical multifocal IOL.Postoperative uncorrected distance visual acuity(UDVA)was 0.0 logMAR(20/20 Snellen)and uncorrected near visual acuity(UNVA)was 0.1 logMAR(20/25 Snellen).Two weeks later,the patient presented to our clinic with decreased vision due to migration of lens epithelial cells to IOL anterior surface and edema of corneal endothelial cells.Anterior capsule polishing and superotemporal placement of near segment[+3.00 diopter(D)addition(add)]of IOL were performed.As a result,UDVA at the first week and first year after reposition was 0.0 logMAR(20/20 Snellen),and compared with 0.3 logMAR(20/40 Snellen)in the first week,the UNVA was improved to 0.0 logMAR(20/20 Snellen)one year after surgery.CONCLUSION The postoperative inflammatory reaction and lens epithelial cells proliferation were obvious in this glaucoma patient.Capsule polishing and rotation of the lens were beneficial to the patient,which not only enhanced the patient's vision,but also improved the patient's satisfaction.Therefore,glaucoma patients need to be cautious of implanting multifocal IOLs.Placement of a near segment of an asymmetrical multifocal IOL in the dominant eye should be performed on an individual basis.展开更多
I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qv...I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qvision) hospitals in Spain.展开更多
Background:To compare objective electrophysiological contrast sensitivity function(CSF)in patients implanted with either multifocal intraocular lenses(MIOLs)or monofocal intraocular lenses(IOLs)by pattern reversal vis...Background:To compare objective electrophysiological contrast sensitivity function(CSF)in patients implanted with either multifocal intraocular lenses(MIOLs)or monofocal intraocular lenses(IOLs)by pattern reversal visual evoked potentials(prVEP)measurements.Methods:Fourty-five cataract patients were randomly allocated to receive bilaterally:apodized diffractive-refractive Alcon Acrysof MIOL(A),full diffractive AMO Tecnis MIOL(B)or monofocal Alcon Acrysof IOL(C).Primary outcomes:1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies.Secondary outcomes:psychophysical CSF measured with VCTS-6500,photopic uncorrected distance(UDVA),and mesopic and photopic uncorrected near and intermediate visual acuities(UNVA and UIVA respectively).Results:Electrophysiological CSF curve had an inverted U-shaped morphology in all groups,with a biphasic pattern in Group B.Group A showed a lower CSF than group B at 4 and 8 cpd,and a lower value than group C at 8 cpd.Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B.Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups.Mesopic UNVA and UIVA were better in group B.Conclusions:Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs.This may be related to the visual acuity under certain conditions or to IOL characteristics.This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.展开更多
Purpose:To investigate the influence of posterior corneal astigmatism on the prediction accuracy of toric multifocal intraocular lens(IOL)calculation.Methods:The keratometric astigmatism measured by Lenstar LS 9...Purpose:To investigate the influence of posterior corneal astigmatism on the prediction accuracy of toric multifocal intraocular lens(IOL)calculation.Methods:The keratometric astigmatism measured by Lenstar LS 900(KCA_(L)),keratometric astigmatism(KCAp)and total corneal astigmatism(TCA)measured by Scheimpflug camera(Pentacam HR)were documented and analyzed accordingly.Three deduction models using different parameters were compared.Model 1:KCA_(L)+keratometric comeal surgically induced astigmatism(KCSIA,0.30 D@50°);Model 2:KCA_(P)+KCSIA);Model 3:TCA 4-total CSIA(TCSIA,0.23 D@50°).The prediction errors of each model as the difference vector between the actual and the intended residual astigmatism were compared.Results:Seventy-six eyes implanted with toric multifocal IOLs were included in this study.The vector differences of the actual KCSIA and TCSIA were statistically significant in the total sample and against-the-rule(ATR)subgroup(both P<0.05).Model 1 deduced the smallest mean values of prediction error,while that of Model 3 were smaller than that of Model 2,both in the total sample and the ATR subgroups(all P<0.05).Meanwhile,in the total sample and ATR subgroups,the centroid vector magnitudes of Model 3 were smaller than that of Model 1(0.31±0.76 D and 0.39±0.76 D).Conclusions:The calculation of toric multifocal IOL should be individualized especially in the ATR eyes for the impact of PCA on the estimation of the preoperative comeal astigmatism and the CSIA.展开更多
Background:To investigate the decentration and tilt of plate-haptic multifocal intraocular lenses(MfIOLs)in myopic eyes.Methods:Myopic(axial length[AXL]>24.5 mm)and non-myopic(21.0 mm<AXL≤24.5 mm)cataract eyes ...Background:To investigate the decentration and tilt of plate-haptic multifocal intraocular lenses(MfIOLs)in myopic eyes.Methods:Myopic(axial length[AXL]>24.5 mm)and non-myopic(21.0 mm<AXL≤24.5 mm)cataract eyes were enrolled in this prospective study and randomly assigned to receive implantation of Zeiss AT LISA tri 839MP lenses(Group A)or Tecnis ZMB00 lenses(Group B).In total,122 eyes of 122 patients were available for analysis.Decentration and tilt of MfIOLs,high-order aberrations(HOAs),and modulation transfer functions(MTFs)were evaluated using the OPD-Scan III aberrometer 3 months postoperatively.Subjective symptoms were assessed with a Quality of Vision questionnaire.Results:Near and distance visual acuities,tilt and horizontal decentration did not differ between the two groups,postoperatively.However,myopic eyes of Group B showed greater vertical decentration than those of Group A(−0.17±0.14 mm vs.-0.03±0.09 mm,respectively),particularly when the MfIOLs were placed horizontally or obliquely.Overall decentration of myopic eyes was greater in Group B than in Group A(0.41±0.15 mm vs.0.16±0.10 mm,respectively).In Group B,AXL was negatively correlated with vertical decentration and positively correlated with overall decentration.No such correlations were found in Group A.Intraocular total HOAs,coma,trefoil and spherical aberrations were lower in Group A than in Group B for a 6.0 mm pupil among myopic eyes.Generally,Group A had better MTFs and fewer subjective symptoms than Group B among myopic eyes.Conclusions:Plate-haptic design of MfIOLs may be a suggested option for myopic cataract eyes due to the less inferior decentration and better visual quality postoperatively.展开更多
Purpose:To evaluate the clinical and visual outcomes,quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens(IOL).Metho...Purpose:To evaluate the clinical and visual outcomes,quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens(IOL).Methods:In this prospective consecutive case series,20 eyes of 10 patients were included(mean age 63.80±12.55 years).Uncorrected and corrected visual acuity(far,intermediate and near),subjective refraction,binocular defocus curve,contrast sensitivity(CSV-1000)and quality of vision and satisfaction questionnaires were measured.The follow-up was 12 months after surgery.Results:At 12 months after surgery,uncorrected distance visual acuity(UDVA)improved with surgery(P=0.001)with a value of 0.08±0.08 logMAR.Uncorrected near visual acuity(UNVA)was 0.22±0.12 logMAR and distance corrected near visual acuity(DCNVA)was 0.16±0.13 logMAR.Intermediate distance visual acuity(UIVA)was 0.22±0.10 logMAR.Contrast sensitivity outcomes were similar to normal population in photopic conditions and slightly reduced in mesopic conditions of lighting.Defocus curve showed that this multifocal iOL was able to provide a visual acuity(VA)equal to or better than 0.16 logMAR between defocus levels of+1.00 to-2.50 D.Good patient satisfaction was obtained in quality of vision and satisfaction questionnaires outcomes.Conclusions:The Precizon Presbyopic NVA IOL(OPHTEC BV)provides good visual outcomes.This multifocal IOL provides a high percentage of spectacle independence due to good VA at far,intermediate and near distances and satisfactory contrast sensitivity.High patient satisfaction was observed in quality of vision and satisfaction questionnaires with a low percentage of patients manifesting photic phenomena.展开更多
Purpose:To evaluate the clinical and visual outcomes,quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens(IOL).Metho...Purpose:To evaluate the clinical and visual outcomes,quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens(IOL).Methods:In this prospective consecutive case series,20 eyes of 10 patients were included(mean age 63.80±12.55 years).Uncorrected and corrected visual acuity(far,intermediate and near),subjective refraction,binocular defocus curve,contrast sensitivity(CSV-1000)and quality of vision and satisfaction questionnaires were measured.The follow-up was 12 months after surgery.Results:At 12 months after surgery,uncorrected distance visual acuity(UDVA)improved with surgery(p=0.001)with a value of 0.08±0.08 logMAR.Uncorrected near visual acuity(UNVA)was 0.22±0.12 logMAR and distance corrected near visual acuity(DCNVA)was 0.16±0.13 logMAR.Intermediate distance visual acuity(UIVA)was 0.22±0.10 logMAR.Contrast sensitivity outcomes were similar to normal population in photopic conditions and slightly reduced in mesopic conditions of lighting.Defocus curve showed that this multifocal IOL was able to provide a visual acuity(VA)equal or better to 0.16 logMAR between defocus levels of+1.00 to−2.50 D.Good patient satisfaction was obtained in quality of vision and satisfaction questionnaires outcomes.Conclusions:The Precizon Presbyopic NVA IOL(OPHTEC BV)provides good visual outcomes.This multifocal IOL provides a high percentage of spectacle independence due to good VA at far,intermediate and near distances and satisfactory contrast sensitivity.High patient satisfaction was observed in quality of vision and satisfaction questionnaires with a low percentage of patients manifesting photic phenomena.展开更多
Background:Presbyopia has become a global disease affecting the world's aging population.Among various treatments,cataract extraction and intraocular lens(IOL)implantation have become the most popular and common m...Background:Presbyopia has become a global disease affecting the world's aging population.Among various treatments,cataract extraction and intraocular lens(IOL)implantation have become the most popular and common methods of presbyopia correction.During the twentieth century,IOLs have underwent significant innovation and advancements to meet the patients'high demands for functional vision at all distances.Main Text:To meet the increasing needs for excellent near and intermediate vision for daily activities,some premium IOLs with more than one focus have been developed,for example,the refractive MfIOLs,diffractive MfIOLs,extended depth of field(EDOF)IOLs,and accommodating IOLs(AIOLs)were introduced to meet this need.In addition,the add-on MfIOLs have been explored as promising supplementary IOLs for pseudophakic presbyopia.When selecting the MfIOLs,the IOLs'features,patients’characteristics,preoperative eye conditions,and treatment expectations should be considered.Conclusions:In this review,we focus on the multifocal IOLs(MfIOLs)commonly used for presbyopia correction and systematically summarized their optical designs and clinical outcomes.More evidence-based studies are required to provide guidelines for MfIOL selection,provide maximum visual benefits,and develop personalized visual solutions in the future.展开更多
Background:Pseudophakic presbyopic correction is among the prevalent methods for regaining near vision capacity.The purpose of this study is to compare the impact of pseudophakic monovision correction and multifocal l...Background:Pseudophakic presbyopic correction is among the prevalent methods for regaining near vision capacity.The purpose of this study is to compare the impact of pseudophakic monovision correction and multifocal lens implantation on the performance in a series of activities of daily living(ADL)of presbyopic patients.Methods:An ADL research framework(10 ADLs)was constructed and validated in a sample of patients divided into three validation groups according to their near visual acuity.Sixty-two participants that underwent mini-monovision(MoG)cataract extraction and 60 that underwent bilateral multifocal lenses implantation(MfG)populated study groups and addressed the ADLs.Binocular uncorrected distant(BdUVA)and near(BnUVA)visual acuity were associated with ADL scores and with subjective satisfaction using the VF-14 questionnaire.Results:Test-retest reliability[all Intraclass Correlations Coefficients(ICC)>0.90]and construct validity(all p<0.05)tests indicated sufficient psychometric performance of the ADL framework.Both study groups presented comparable mean ADL scores(p=0.07)however,MoG patients had lower performance in demanding ADLs(p=0.02).ADL scores demonstrated significant correlation with BnUVA(r^(2)=−0.67,p<0.01)VF-14 scores(r^(2)=0.53,p<0.01).Conclusions:Both methods provide sufficient near vision capacity for the majority of activities of daily living.However,only multifocal lens implantation can address demanding near vision tasks.展开更多
文摘AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patients who underwent unilateral cataract surgery,followed by implantation of rotationally asymmetric MIOLs were included.Distance and near visual acuity outcomes,intraocular aberrations,preferred reading distances,preoperative and postoperative refractive errors,mesopic and photopic pupil diameters,and the mesopic and photopic kappa angles were assessed.Patients were also administered a satisfaction survey.Photic phenomena were graded by questionnaire.Independent-related factors were identified by correlation and bivariate logistic regression analyses.RESULTS: The distance from the photopic to the mesopic pupil center(pupil center shift) was significantly associated with glare/halo symptoms [odds ratio(OR)=2.065,95% confidence interval(CI)=0.916-4.679,P=0.006] and night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007).The preoperative photopic angle kappa was significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041).The photopic angle kappa was also significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041) and with night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007) in patients implanted with rotationally asymmetric MIOLs.CONCLUSION: A large pupil center shift and misalignment between the visual and pupillary axis(angle kappa)may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs.
基金Supported by the Student Research Grant of University of Ulsan College of Medicine,Seoul,Korea(No.17-18)Grant from the Asan Institute for Life Sciences,Seoul,Korea(No.2014-464)。
文摘AIM:To evaluate clinical outcomes of unilateral implantation of a diffractive multifocal intraocular lens(IOL)in patients with contralateral monofocal IOL.METHODS:Twenty-two patients who already had implantation of a monofocal IOL in unilateral eye underwent implantation of a diffractive multifocal IOL in contralateral eye were enrolled.After 1,6,and 12 mo,uncorrected and distant corrected distant visual acuity(UCDVA and DCDVA),uncorrected and distant corrected intermediate-visual acuity(UCIVA and DCIVA),uncorrected and distant corrected near visual acuity(UCNVA and DCNVA),and contrast sensitivity were obtained.Halo/glare symptoms,spectacle dependence,and patient satisfaction were also evaluated.RESULTS:The mean age was 67.86±7.25 y and the average interval between two IOL implantations was 645.82±878.44 d.At 1 mo,binocular UCDVA was lower than 0.20 logMAR in 76%of patients(mean 0.12±0.13 logMAR),which increased to 90%by 6 and 12 mo.The binocular UCDVA was significantly better than the monocular results(P<0.05)at 1,6,and 12 mo.Additionally,UCNVA was lower than 0.40 logMAR in 82%of patients,increasing to 90%by 6 and 12 mo.Mean UCNVA in the multifocal IOL implanted eye was statistically significantly better than that in the monofocal IOL implanted eye(P<0.05)at 1,6,and 12 mo.About 5%of patients at 1 and 6 mo,reported"severe glare or halo".Patient satisfaction rates were 95%and 91%at 6 and 12 mo,respectively.CONCLUSION:Unilateral implantation of multifocal IOL in patients with a contralateral,monofocal IOL implantation results in high patient satisfaction rate,with low severe glare or halo rate during follow-up.It can represent a good option for patients who have previously had a monofocal IOL implantation regardless of two year interval duration between two IOL implantations.
基金Supported by National Key Research and Development Program of China(No.2017YFC1104600)National Natural Science Foundation of China(No.81770909)。
文摘AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification and implantation with the SBL-3 segmented multifocal IOL between January 1,2017 and January 31,2019 were included in this retrospective study.Preoperative biometry measurements were obtained using an IOL Master.Manifest refraction was performed at least 4 wk postoperatively.Accuracy of the eight formulas[Barrett Universal II,Emmetropia Verifying Optical(EVO),Haigis,Hill-RBF 2.0,Hoffer Q,Holladay 1,Kane,and SRK/T]was analyzed.RESULTS:Using current lens constants,all formulas exhibited errors of slight myopic shift in refractive prediction.The Barrett Universal II formula had a significantly lower median absolute error(MedAE)than did Holladay 1(P=0.02),Kane(P=0.001)and Hill-RBF 2.0(P<0.001)formulas.The Haigis formula had a lower MedAE value than did the Hill-RBF 2.0 formula(P=0.005).Differences in MedAE values among SRK/T,EVO and Hoffer Q formulas were not significant.After optimizing lens constants,the MedAE values of all formulas were reduced;significant changes were noted for EVO(P=0.022),Haigis(P=0.048);Hill-RBF 2.0(P=0.014),Holladay 1(P=0.045)and Kane(P=0.022)formulas.All formulas performed equally well after optimization of lens constants(P=0.203).CONCLUSION:All eight formulas tend to result in a myopic shift when using current lens constants.Optimized lens constants improve the accuracy of these formulas among adult Chinese patients.
基金Coco-Martin MB,Maldonado-López MJ,Molina-Martín A and Pi?ero DP are supported by CDTI(Centro para el Desarrollo Tecnológico Industrial,Ministry of Economy and Competitiveness of Spain)by means of the program PID(“Proyectos de Investigación y Desarrollo”)The author Pi?ero DP has been also supported by the Ministry of Economy,Industry and Competitiveness of Spain within the program Ramón y Cajal(RYC-2016-20471)Valenzuela PL is supported by a contract granted by University of Alcalá(FPI2016)
文摘Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they are associated with a higher prevalence of dysphotopsia symptoms that is one of the most common causes of patient dissatisfaction. Neuroadaptation seems to play a major role in the optimal adaptation to multifocal IOLs. In this context, the development of strategies that facilitate the neuroadaptation process to multifocality might be an effective strategy to reduce patients' dissatisfaction. Video games have been proved to be effective for the improvement of visual acuity and for the promotion of neuroplasticity in elderly subjects and other populations with cortical-related visual impairment. This narrative review highlights the physiological potential of video games as a perceptual strategy to improve visual acuity and promote neuroplasticity in patients using multifocalIOLs, although research is still needed to confirm these benefits in this specific population, with only one comparative study to this date providing evidence of them.
文摘Dear Editor,We write you to present a 20-year-old man with resistant spasm of accommodation without any organic cause treated with clear lens extraction(CLE)with phacoemulsification and multifocal intraocular lens(IOL)implantation.
文摘AIM: To evaluate the clinical utility of automated refraction(AR) and keratometry(KR) compared with subjective or manifest refraction(MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X(Oculentis GmbH) refractive multifocal intraocular lens(IOL).METHODS: Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3 mo follow-up.RESULTS: Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was-1.28±0.29 diopters(D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION: We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.
基金Supported by Key Research and Development Projects of Shaanxi Province(No.2017SF-246)Science and Technology Planning Project of Xi’an(No.2017116SF/YX010No.201805097YX5SF31)。
文摘·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs:AT LISA tri 839 MP(30 eyes;Carl Zeiss Meditec,Germany)and LS-313 MF30(30 eyes;Oculentis GmbH,Germany).Visual acuity,refractive outcome,contrast sensitivity,defocus curves,quality of vision,and optical phenomena were evaluated at3 mo postoperatively.·RESULTS:There were no statistical differences between groups in uncorrected distance visual acuity(P=0.13)and uncorrected near visual acuity(P=0.54).In contrast,uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group(P=0.02).No significant statistical between-group difference was detected in cylinder(P=0.43).Compared to trifocal group,spherical refraction and spherical equivalent in refractive multi focal group were more myopic(P<0.01).Under photopic conditions,no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree(cpd).The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group(P=0.01,P=0.034,respectively).The questionnaires of quality of vision and optical phenomena showed no differences between groups.·CONCLUSION:Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity.Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency.
基金Supported by National Natural Science Foundation of China,No.81974130Natural Science Foundation of Hunan Province,China,No.2020JJ4882.
文摘BACKGROUND Asymmetric multifocal intraocular lenses(IOLs)are now widely used in the modern cataract surgery,providing a good level of visual performance over a range of distances and high postoperative patient satisfaction.We report a case of improved visual quality after shifting the near segment of an asymmetrical multifocal IOL to the superotemporal placement in the dominant eye of a glaucoma patient.CASE SUMMARY A 72-year-old woman with bilateral glaucoma underwent phacoemulsification in the dominant eye(left eye)with implantation of an asymmetrical multifocal IOL.Postoperative uncorrected distance visual acuity(UDVA)was 0.0 logMAR(20/20 Snellen)and uncorrected near visual acuity(UNVA)was 0.1 logMAR(20/25 Snellen).Two weeks later,the patient presented to our clinic with decreased vision due to migration of lens epithelial cells to IOL anterior surface and edema of corneal endothelial cells.Anterior capsule polishing and superotemporal placement of near segment[+3.00 diopter(D)addition(add)]of IOL were performed.As a result,UDVA at the first week and first year after reposition was 0.0 logMAR(20/20 Snellen),and compared with 0.3 logMAR(20/40 Snellen)in the first week,the UNVA was improved to 0.0 logMAR(20/20 Snellen)one year after surgery.CONCLUSION The postoperative inflammatory reaction and lens epithelial cells proliferation were obvious in this glaucoma patient.Capsule polishing and rotation of the lens were beneficial to the patient,which not only enhanced the patient's vision,but also improved the patient's satisfaction.Therefore,glaucoma patients need to be cautious of implanting multifocal IOLs.Placement of a near segment of an asymmetrical multifocal IOL in the dominant eye should be performed on an individual basis.
文摘I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qvision) hospitals in Spain.
文摘Background:To compare objective electrophysiological contrast sensitivity function(CSF)in patients implanted with either multifocal intraocular lenses(MIOLs)or monofocal intraocular lenses(IOLs)by pattern reversal visual evoked potentials(prVEP)measurements.Methods:Fourty-five cataract patients were randomly allocated to receive bilaterally:apodized diffractive-refractive Alcon Acrysof MIOL(A),full diffractive AMO Tecnis MIOL(B)or monofocal Alcon Acrysof IOL(C).Primary outcomes:1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies.Secondary outcomes:psychophysical CSF measured with VCTS-6500,photopic uncorrected distance(UDVA),and mesopic and photopic uncorrected near and intermediate visual acuities(UNVA and UIVA respectively).Results:Electrophysiological CSF curve had an inverted U-shaped morphology in all groups,with a biphasic pattern in Group B.Group A showed a lower CSF than group B at 4 and 8 cpd,and a lower value than group C at 8 cpd.Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B.Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups.Mesopic UNVA and UIVA were better in group B.Conclusions:Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs.This may be related to the visual acuity under certain conditions or to IOL characteristics.This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.
基金the Science&Technology Development Fund of Tianjin Education Commission for Higher Education[2017KJ214]the High-level Innovative Talent Program for Young Scholar of Tianjin Medical University Eye Hospital[YDYYRCXM-C2018-01]+2 种基金the Tianjin Key Medical Discipline(Specialty)Construction Projectthe National Natural Science Foundation of China[81900846]the Tianjin Health Science and technology project[ZC20207].
文摘Purpose:To investigate the influence of posterior corneal astigmatism on the prediction accuracy of toric multifocal intraocular lens(IOL)calculation.Methods:The keratometric astigmatism measured by Lenstar LS 900(KCA_(L)),keratometric astigmatism(KCAp)and total corneal astigmatism(TCA)measured by Scheimpflug camera(Pentacam HR)were documented and analyzed accordingly.Three deduction models using different parameters were compared.Model 1:KCA_(L)+keratometric comeal surgically induced astigmatism(KCSIA,0.30 D@50°);Model 2:KCA_(P)+KCSIA);Model 3:TCA 4-total CSIA(TCSIA,0.23 D@50°).The prediction errors of each model as the difference vector between the actual and the intended residual astigmatism were compared.Results:Seventy-six eyes implanted with toric multifocal IOLs were included in this study.The vector differences of the actual KCSIA and TCSIA were statistically significant in the total sample and against-the-rule(ATR)subgroup(both P<0.05).Model 1 deduced the smallest mean values of prediction error,while that of Model 3 were smaller than that of Model 2,both in the total sample and the ATR subgroups(all P<0.05).Meanwhile,in the total sample and ATR subgroups,the centroid vector magnitudes of Model 3 were smaller than that of Model 1(0.31±0.76 D and 0.39±0.76 D).Conclusions:The calculation of toric multifocal IOL should be individualized especially in the ATR eyes for the impact of PCA on the estimation of the preoperative comeal astigmatism and the CSIA.
基金Publication of this article was supported by research grants from the National Natural Science Foundation of the People’s Republic of China(grant nos.81870642,81670835 and 81470613)the Shanghai High Myopia Study Group,the International Science and Technology Cooperation Foundation of Shanghai(grant no.14430721100)the Outstanding Youth Medical Talents Program of Shanghai Health and Family Planning Commission(grant no.2017YQ011).
文摘Background:To investigate the decentration and tilt of plate-haptic multifocal intraocular lenses(MfIOLs)in myopic eyes.Methods:Myopic(axial length[AXL]>24.5 mm)and non-myopic(21.0 mm<AXL≤24.5 mm)cataract eyes were enrolled in this prospective study and randomly assigned to receive implantation of Zeiss AT LISA tri 839MP lenses(Group A)or Tecnis ZMB00 lenses(Group B).In total,122 eyes of 122 patients were available for analysis.Decentration and tilt of MfIOLs,high-order aberrations(HOAs),and modulation transfer functions(MTFs)were evaluated using the OPD-Scan III aberrometer 3 months postoperatively.Subjective symptoms were assessed with a Quality of Vision questionnaire.Results:Near and distance visual acuities,tilt and horizontal decentration did not differ between the two groups,postoperatively.However,myopic eyes of Group B showed greater vertical decentration than those of Group A(−0.17±0.14 mm vs.-0.03±0.09 mm,respectively),particularly when the MfIOLs were placed horizontally or obliquely.Overall decentration of myopic eyes was greater in Group B than in Group A(0.41±0.15 mm vs.0.16±0.10 mm,respectively).In Group B,AXL was negatively correlated with vertical decentration and positively correlated with overall decentration.No such correlations were found in Group A.Intraocular total HOAs,coma,trefoil and spherical aberrations were lower in Group A than in Group B for a 6.0 mm pupil among myopic eyes.Generally,Group A had better MTFs and fewer subjective symptoms than Group B among myopic eyes.Conclusions:Plate-haptic design of MfIOLs may be a suggested option for myopic cataract eyes due to the less inferior decentration and better visual quality postoperatively.
基金funded by Network for Cooperative Research in Health"OFTARED"(Reference:RD16/0008/0012),Instituto de Salud CarlosⅢllandwas co-funded by European Regional Development Fund(ERDF),"Away to make Europe"。
文摘Purpose:To evaluate the clinical and visual outcomes,quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens(IOL).Methods:In this prospective consecutive case series,20 eyes of 10 patients were included(mean age 63.80±12.55 years).Uncorrected and corrected visual acuity(far,intermediate and near),subjective refraction,binocular defocus curve,contrast sensitivity(CSV-1000)and quality of vision and satisfaction questionnaires were measured.The follow-up was 12 months after surgery.Results:At 12 months after surgery,uncorrected distance visual acuity(UDVA)improved with surgery(P=0.001)with a value of 0.08±0.08 logMAR.Uncorrected near visual acuity(UNVA)was 0.22±0.12 logMAR and distance corrected near visual acuity(DCNVA)was 0.16±0.13 logMAR.Intermediate distance visual acuity(UIVA)was 0.22±0.10 logMAR.Contrast sensitivity outcomes were similar to normal population in photopic conditions and slightly reduced in mesopic conditions of lighting.Defocus curve showed that this multifocal iOL was able to provide a visual acuity(VA)equal to or better than 0.16 logMAR between defocus levels of+1.00 to-2.50 D.Good patient satisfaction was obtained in quality of vision and satisfaction questionnaires outcomes.Conclusions:The Precizon Presbyopic NVA IOL(OPHTEC BV)provides good visual outcomes.This multifocal IOL provides a high percentage of spectacle independence due to good VA at far,intermediate and near distances and satisfactory contrast sensitivity.High patient satisfaction was observed in quality of vision and satisfaction questionnaires with a low percentage of patients manifesting photic phenomena.
基金Network for Cooperative Research in Health“OFTARED”–Reference:RD16/0008/0012Funded by Instituto de Salud Carlos III and co-funded by European Regional Development Fund(ERDF),“A way to make Europe”.
文摘Purpose:To evaluate the clinical and visual outcomes,quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens(IOL).Methods:In this prospective consecutive case series,20 eyes of 10 patients were included(mean age 63.80±12.55 years).Uncorrected and corrected visual acuity(far,intermediate and near),subjective refraction,binocular defocus curve,contrast sensitivity(CSV-1000)and quality of vision and satisfaction questionnaires were measured.The follow-up was 12 months after surgery.Results:At 12 months after surgery,uncorrected distance visual acuity(UDVA)improved with surgery(p=0.001)with a value of 0.08±0.08 logMAR.Uncorrected near visual acuity(UNVA)was 0.22±0.12 logMAR and distance corrected near visual acuity(DCNVA)was 0.16±0.13 logMAR.Intermediate distance visual acuity(UIVA)was 0.22±0.10 logMAR.Contrast sensitivity outcomes were similar to normal population in photopic conditions and slightly reduced in mesopic conditions of lighting.Defocus curve showed that this multifocal IOL was able to provide a visual acuity(VA)equal or better to 0.16 logMAR between defocus levels of+1.00 to−2.50 D.Good patient satisfaction was obtained in quality of vision and satisfaction questionnaires outcomes.Conclusions:The Precizon Presbyopic NVA IOL(OPHTEC BV)provides good visual outcomes.This multifocal IOL provides a high percentage of spectacle independence due to good VA at far,intermediate and near distances and satisfactory contrast sensitivity.High patient satisfaction was observed in quality of vision and satisfaction questionnaires with a low percentage of patients manifesting photic phenomena.
基金the National Natural Science Foundation of China(Grant No.81970779 to Zhu Yanan).
文摘Background:Presbyopia has become a global disease affecting the world's aging population.Among various treatments,cataract extraction and intraocular lens(IOL)implantation have become the most popular and common methods of presbyopia correction.During the twentieth century,IOLs have underwent significant innovation and advancements to meet the patients'high demands for functional vision at all distances.Main Text:To meet the increasing needs for excellent near and intermediate vision for daily activities,some premium IOLs with more than one focus have been developed,for example,the refractive MfIOLs,diffractive MfIOLs,extended depth of field(EDOF)IOLs,and accommodating IOLs(AIOLs)were introduced to meet this need.In addition,the add-on MfIOLs have been explored as promising supplementary IOLs for pseudophakic presbyopia.When selecting the MfIOLs,the IOLs'features,patients’characteristics,preoperative eye conditions,and treatment expectations should be considered.Conclusions:In this review,we focus on the multifocal IOLs(MfIOLs)commonly used for presbyopia correction and systematically summarized their optical designs and clinical outcomes.More evidence-based studies are required to provide guidelines for MfIOL selection,provide maximum visual benefits,and develop personalized visual solutions in the future.
文摘Background:Pseudophakic presbyopic correction is among the prevalent methods for regaining near vision capacity.The purpose of this study is to compare the impact of pseudophakic monovision correction and multifocal lens implantation on the performance in a series of activities of daily living(ADL)of presbyopic patients.Methods:An ADL research framework(10 ADLs)was constructed and validated in a sample of patients divided into three validation groups according to their near visual acuity.Sixty-two participants that underwent mini-monovision(MoG)cataract extraction and 60 that underwent bilateral multifocal lenses implantation(MfG)populated study groups and addressed the ADLs.Binocular uncorrected distant(BdUVA)and near(BnUVA)visual acuity were associated with ADL scores and with subjective satisfaction using the VF-14 questionnaire.Results:Test-retest reliability[all Intraclass Correlations Coefficients(ICC)>0.90]and construct validity(all p<0.05)tests indicated sufficient psychometric performance of the ADL framework.Both study groups presented comparable mean ADL scores(p=0.07)however,MoG patients had lower performance in demanding ADLs(p=0.02).ADL scores demonstrated significant correlation with BnUVA(r^(2)=−0.67,p<0.01)VF-14 scores(r^(2)=0.53,p<0.01).Conclusions:Both methods provide sufficient near vision capacity for the majority of activities of daily living.However,only multifocal lens implantation can address demanding near vision tasks.