期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
A Study of DTC-Power Electronic Cascade Fed by Photovoltaic Cell-Three-Level NPC Inverter
1
作者 Iqbal Messaif El-Madjid Berkouk Nadia Saadia 《Smart Grid and Renewable Energy》 2010年第3期109-118,共10页
This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can als... This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can also convert the photovoltaic DC power into high quality AC power. Attention has been paid to the problem of neutral point potential variation. In this way, a Direct Torque Control (DTC) technique has been applied and the estimated value of the Neutral Point Potential (NPP) is used, which is calculated by motor currents. This control strategy uses the redundancy presented by the inverter for selecting appropriate switching state through a switching table to achieve the control of NPP. This study shows the effect of the stability problem of the DC voltages and good static and dynamic performances were obtained in simulation of the proposed cascade “photovoltaic cell-three-level NPC VSI-induction motor”. 展开更多
关键词 DTC Switching Table npc three-level inverter Photovoltaic Neutral Point Potential Redundant States
下载PDF
Multi-objective Model Predictive Control of Grid-connected Three-level Inverter Based on Hierarchical Optimization
2
作者 Ting Liu Yong Li +4 位作者 Li Jiang Jianghu Wan Jiaqi Yu Chao Ding Yijia Cao 《Chinese Journal of Electrical Engineering》 CSCD 2021年第1期63-72,共10页
In order to solve the problem of weighting factors selection in the conventional finite-control-set model predictive control for a grid-connected three-level inverter,an improved multi-objective model predictive contr... In order to solve the problem of weighting factors selection in the conventional finite-control-set model predictive control for a grid-connected three-level inverter,an improved multi-objective model predictive control without weighting factors based on hierarchical optimization is proposed.Four control objectives are considered in this strategy.The grid current and neutral-point voltage of the DC-link are taken as the objectives in the first optimization hierarchy,and by using fuzzy satisfaction decision,several feasible candidates of voltage vectors are determined.Then,the average switching frequency and common-mode voltage are optimized in the second hierarchy.The average ranking criterion is introduced to sort the objective functions,and the best voltage vector is obtained to realize the coordinated control of multiple objectives.At last,the effectiveness of the proposed strategy is verified by simulation results. 展开更多
关键词 Multi-objective model predictive control grid-connected three-level inverter hierarchical optimization fuzzy satisfaction decision average ranking criterion
原文传递
Impedance Modeling and Stability Analysis of a Three-phase Three-level NPC Inverter Connected to the Grid 被引量:5
3
作者 Bo Zhang Xiong Du +2 位作者 Jingbo Zhao Jiapei Zhou Xiaoming Zou 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第2期270-278,共9页
The interaction between grid-connected inverters and the grid may cause stability issues,and compromise the reliable operation of the inverters.This study investigates the stability of a three-level neutral point clam... The interaction between grid-connected inverters and the grid may cause stability issues,and compromise the reliable operation of the inverters.This study investigates the stability of a three-level neutral point clamped(NPC)inverter connected to the grid using impedance-based methods.Because the impedance model of a three-phase three-level NPC inverter has not yet been reported,this study fills the literature gap by analyzing the influence of three-level DC-side neutral point control on the impedance characteristics.By fully considering the DC bus dynamics and DC voltage control loop,and the current loop and phase-locked loop(PLL),the admittance model of a three-phase three-level NPC inverter is established and verified by simulation.Additionally,in the stability analysis of a threelevel NPC inverter grid-connected system,the frequency coupling introduced by the PLL and DC bus dynamics is included with the help of an established admittance model.The stability of the grid-connected system under different grid short circuit ratios(SCR)and operating power levels is analyzed according to the Nyquist stability criterion.The experimental results revealed that the established impedance model of the three-phase three-level NPC inverter can properly represent the stability of this system. 展开更多
关键词 grid-connected inverter neutral point control STABILITY three-level
原文传递
Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques for all voltage disturbances compensation 被引量:1
4
作者 Salim CHENNAI M-T BENCHOUIA 《Frontiers in Energy》 SCIE CSCD 2014年第2期221-239,共19页
This paper presents a novel and efficient control scheme for unified power quality conditioner (UPQC) based on three-level neutral point clamped (NPC) inverter using fuzzy logic techniques. The proposed UPQC is ca... This paper presents a novel and efficient control scheme for unified power quality conditioner (UPQC) based on three-level neutral point clamped (NPC) inverter using fuzzy logic techniques. The proposed UPQC is capable of mitigating source current harmonics and compensate all voltage disturbances such as voltage sags, swells, unbalances and harmonics. It is designed by the integration of series and shunt active filters (AFs) sharing a common DC bus capacitor. The DC voltage is maintained constant using proportional integral voltage controller. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt active power filters (APFs) and the power reactive theory (p-q theory) for series APFs. The shunt and series APF reference signals derived from the control algorithm and sensed signals are injected in two controllers to generate switching signals. To improve the UPQC capability, fuzzy logic techniques are introduced to control the series APF. The performances of the proposed UPQC system are evaluated in terms of power factor correction, mitigation of voltage or current harmonics and all other voltage disturbances compensation using Matlab-Simulink software and SimPowerSystem toolbox. The simulation results illustrate the performance of the proposed UPQC at the common connection point of the nonlinear load to improve the power energy quality. 展开更多
关键词 three-level neutral point clamped npc inverter unified power quality conditioner (UPQC) current
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部