This review paper reports near-infrared(NIR)imaging studies using a newly-developed NIR camera,Compovision.Compovision can measure a significantly wide area of 150mm×250mm at high speed of between 2and 5s.It enab...This review paper reports near-infrared(NIR)imaging studies using a newly-developed NIR camera,Compovision.Compovision can measure a significantly wide area of 150mm×250mm at high speed of between 2and 5s.It enables a wide spectral region measurement in the 1 000~2 350nm range at 6nm intervals.We investigated the potential of Compovision in the applications to industrial problems such as the evaluation of pharmaceutical tablets and polymers.Our studies have demonstrated that NIR imaging based on Compovision can solve several issues such as long acquisition times and relatively low sensitivity of detection.NIR imaging with Compovision is strongly expected to be applied not only to pharmaceutical tablet monitoring and polymer characterization but also to various applications such as those to food products,biomedical substances and organic and inorganic materials.展开更多
Subcutaneous vein network plays important roles to maintain microcirculation that is related to some diagnostic aspects.Despite developments of optical imaging technologies,still the difficulties about deep skin vascu...Subcutaneous vein network plays important roles to maintain microcirculation that is related to some diagnostic aspects.Despite developments of optical imaging technologies,still the difficulties about deep skin vascular imaging have been continued.On the other hand,since hemoglobin con-centration of human blood has key role in the veins imaging by optical manner,the used wavelength in vascular imaging,must be chosen considering absorption of hemoglobin.In this research,we constructed a near infrared(NIR)light source because of lower absorption of hemoglobin in this optical region.To obtain vascular image,reflectance geometry was used.Next,from recorded images,vascular network analysis,such as calculation of width of vascular of interest and complexity of selected region were implemented.By comparing with other modalities,we observed that proposed imaging system has great advantages including nonionized radiation,moderate penetration depth of 0.5-3 mm and diameter of 1 mm,cost-effective and algorit hmic simplicity for analysis.展开更多
We present a novel optical sensor to acquire simultaneously functional near-infrared imaging(fNIRI)and functional magnetic resonance imaging(fMRI)data with an improved handling and direct localization in the MRI compa...We present a novel optical sensor to acquire simultaneously functional near-infrared imaging(fNIRI)and functional magnetic resonance imaging(fMRI)data with an improved handling and direct localization in the MRI compared to available sensors.Quantitative phantom and interference measurements showed that both methods can be combined without reciprocal adverse effects.The direct localization of the optical sensor on MR images acquired with a T1-weighted echo sequence simplifies the co-registration of NIRI and MRI data.In addition,the optical sensor is simple to attach,which is crucial for measurements on vulnerable subjects.The fNIRI and T2^(*)-weighted fMRI data of a cerebral activation were simultaneously acquired proving the practicability of the setup.展开更多
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical...Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.展开更多
Optical memory effect-based speckle-correlated technology has been developed for reconstructing hidden objectsfrom disordered speckle patterns,achieving imaging through scattering layers.However,the lighting efficienc...Optical memory effect-based speckle-correlated technology has been developed for reconstructing hidden objectsfrom disordered speckle patterns,achieving imaging through scattering layers.However,the lighting efficiency and fieldof view of existing speckle-correlated imaging systems are limited.Here,a near-infrared low spatial coherence fiberrandom laser illumination method is proposed to address the above limitations.Through the utilization of random Rayleighscattering within dispersion-shifted fibers to provide feedback,coupled with stimulated Raman scattering for amplification,a near-infrared fiber random laser exhibiting a high spectral density and extremely low spatial coherence is generated.Based on the designed fiber random laser,speckle-correlated imaging through scattering layers is achieved,with highlighting efficiency and a large imaging field of view.This work improves the performance of speckle-correlated imagingand enriches the research on imaging through scattering medium.展开更多
The adulteration concentration of palm kernel oil(PKO)in virgin coconut oil(VCO)was quantified using near-infrared(NIR)hyperspectral imaging.Nowadays,some VCO is adulterated with lower-priced PKO to reduce production ...The adulteration concentration of palm kernel oil(PKO)in virgin coconut oil(VCO)was quantified using near-infrared(NIR)hyperspectral imaging.Nowadays,some VCO is adulterated with lower-priced PKO to reduce production costs,which diminishes the quality of the VCO.This study used NIR hyperspectral imaging in the wavelength region 900-1,650 nm to create a quantitative model for the detection of PKO contaminants(0-100%)in VCO and to develop predictive mapping.The prediction equation for the adulteration of VCO with PKO was constructed using the partial least squares regression method.The best predictive model was pre-processed using the standard normal variate method,and the coefficient of determination of prediction was 0.991,the root mean square error of prediction was 2.93%,and the residual prediction deviation was 10.37.The results showed that this model could be applied for quantifying the adulteration concentration of PKO in VCO.The prediction adulteration concentration mapping of VCO with PKO was created from a calibration model that showed the color level according to the adulteration concentration in the range of 0-100%.NIR hyperspectral imaging could be clearly used to quantify the adulteration of VCO with a color level map that provides a quick,accurate,and non-destructive detection method.展开更多
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr...The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).展开更多
The aim of this research was to determine the rice protein content utilizing a NIR imaging system.The developed imaging system utilized a NIR camera which installed automatically exchanged filters with the wavelength ...The aim of this research was to determine the rice protein content utilizing a NIR imaging system.The developed imaging system utilized a NIR camera which installed automatically exchanged filters with the wavelength range from 870 nm to 1014 nm.Multiple liner regression(MLR),partial least square regression(PLSR),and artificial neural network(ANN)models were employed as data analysis methods for 6.18%-9.43%rice protein detections within both the NIR imaging system and commercial NIRS.A total of 180 rice samples were used in this study,of which 120 random samples were selected as a calibration set for the MLR and PLSR models.Moreover,for establishing the back-propagation ANN model,the same 120 samples were divided into two parts,80 samples were used for network training and the other 40 were established as the monitoring set.To compare with the results of MLR,PLSR,and ANN models,the remaining 60 of the total 180 samples were established as the validation set.Applying an MLR linear regression model composed of five wavelengths;the NIR imaging system successfully detected rice protein content.The predicting results of r_(val)^(2) and SEP were 0.769 and 0.294%,respectively.In PLSR model,utilizing the imaging system obtained the results of r_(val)^(2)=0.782,and SEP=0.274%within the wavelength range from 870 nm to 1014 nm.Five significant wavelengths selected by the MLR model were the same as the input data of the ANN model,and the prediction results were r_(val)^(2)=0.806,and SEP=0.266%.The prediction results indicated that the developed NIR imaging system has the advantages of simple,convenient operation,and high detection accuracy as well as it presents commercial potential in non-destructive detection of rice protein content.展开更多
Historically,psychiatric diagnoses have been made based on patient’s reported symptoms applying the criteria from diagnostic and statistical manual of mental disorders.The utilization of neuroimaging or biomarkers to...Historically,psychiatric diagnoses have been made based on patient’s reported symptoms applying the criteria from diagnostic and statistical manual of mental disorders.The utilization of neuroimaging or biomarkers to make the diagnosis and manage psychiatric disorders remains a distant goal.There have been several studies that examine brain imaging in psychiatric disorders,but more work is needed to elucidate the complexities of the human brain.In this editorial,we examine two articles by Xu et al and Stoyanov et al,that show developments in the direction of using neuroimaging to examine the brains of people with schizo-phrenia and depression.Xu et al used magnetic resonance imaging to examine the brain structure of patients with schizophrenia,in addition to examining neurotransmitter levels as biomarkers.Stoyanov et al used functional magnetic resonance imaging to look at modulation of different neural circuits by diagnostic-specific scales in patients with schizophrenia and depression.These two studies provide crucial evidence in advancing our understanding of the brain in prevalent psychiatric disorders.展开更多
Moderate to severe perinatal hypoxic-ischemic encephalopathy occurs in~1 to 3/1000 live births in high-income countries and is associated with a significant risk of death or neurodevelopmental disability.Detailed asse...Moderate to severe perinatal hypoxic-ischemic encephalopathy occurs in~1 to 3/1000 live births in high-income countries and is associated with a significant risk of death or neurodevelopmental disability.Detailed assessment is important to help identify highrisk infants,to help families,and to support appropriate interventions.A wide range of monitoring tools is available to assess changes over time,including urine and blood biomarkers,neurological examination,and electroencephalography.At present,magnetic resonance imaging is unique as although it is expensive and not suited to monitoring the early evolution of hypoxic-ischemic encephalopathy by a week of life it can provide direct insight into the anatomical changes in the brain after hypoxic-ischemic encephalopathy and so offers strong prognostic information on the long-term outcome after hypoxic-ischemic encephalopathy.This review investigated the temporal dynamics of neonatal hypoxic-ischemic encephalopathy injuries,with a particular emphasis on exploring the correlation between the prognostic implications of magnetic resonance imaging scans in the first week of life and their relationship to long-term outcome prediction,particularly for infants treated with therapeutic hypothermia.A comprehensive literature search,from 2016 to 2024,identified 20 pertinent articles.This review highlights that while the optimal timing of magnetic resonance imaging scans is not clear,overall,it suggests that magnetic resonance imaging within the first week of life provides strong prognostic accuracy.Many challenges limit the timing consistency,particularly the need for intensive care and clinical monitoring.Conversely,although most reports examined the prognostic value of scans taken between 4 and 10 days after birth,there is evidence from small numbers of cases that,at times,brain injury may continue to evolve for weeks after birth.This suggests that in the future it will be important to explore a wider range of times after hypoxic-ischemic encephalopathy to fully understand the optimal timing for predicting long-term outcomes.展开更多
Sotos syndrome is characterized by overgrowth features and is caused by alterations in the nuclear receptor binding SET domain protein 1 gene.Attentiondeficit/hyperactivity disorder(ADHD)is considered a neurodevelopme...Sotos syndrome is characterized by overgrowth features and is caused by alterations in the nuclear receptor binding SET domain protein 1 gene.Attentiondeficit/hyperactivity disorder(ADHD)is considered a neurodevelopment and psychiatric disorder in childhood.Genetic characteristics and clinical presentation could play an important role in the diagnosis of Sotos syndrome and ADHD.Magnetic resonance imaging(MRI)has been used to assess medical images in Sotos syndrome and ADHD.The images process is considered to display in MRI while wavelet fusion has been used to integrate distinct images for achieving more complete information in single image in this editorial.In the future,genetic mechanisms and artificial intelligence related to medical images could be used in the clinical diagnosis of Sotos syndrome and ADHD.展开更多
Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism....Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism.This review provides a comprehensive summary of the latest developments in the application of presynaptic dopaminergic positron emission tomography imaging in disorders that manifest parkinsonism.We conducted a thorough literature search using reputable databases such as PubMed and Web of Science.Selection criteria involved identifying peer-reviewed articles published within the last 5 years,with emphasis on their relevance to clinical applications.The findings from these studies highlight that presynaptic dopaminergic positron emission tomography has demonstrated potential not only in diagnosing and differentiating various Parkinsonian conditions but also in assessing disease severity and predicting prognosis.Moreover,when employed in conjunction with other imaging modalities and advanced analytical methods,presynaptic dopaminergic positron emission tomography has been validated as a reliable in vivo biomarker.This validation extends to screening and exploring potential neuropathological mechanisms associated with dopaminergic depletion.In summary,the insights gained from interpreting these studies are crucial for enhancing the effectiveness of preclinical investigations and clinical trials,ultimately advancing toward the goals of neuroregeneration in parkinsonian disorders.展开更多
Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of ...Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of life of patients,several endeavors have been made toward precision medicine through image-guided surgery,allowing access to real-time intraoperative anatomy and accurate tumor staging.The goal of the surgeon is to achieve a more precise,individualized,and less invasive surgery without compromising oncological efficiency and safety.In this perspective,we have demonstrated the role of indocyanine green(ICG)and near-infrared(NIR)fluorescence imaging method in gastric cancer surgery.This technique may be used to improve localization of the tumor,detection of sentinel lymph nodes(SLN),real-time lymphatic mapping,and blood flow assessment(anastomosis perfusion).展开更多
Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determine...Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determined by immunohistochemical(IHC) staining using tissue microarrays with the H-score system and immunofluorescence(IF) staining of tumor cell lines.Imaging probes with the NIR fluorescent dye cyanine 7(Cy7) conjugated to COC183 B2 Mab were chemically engineered. OC183 B2-positive human OC cells(SKOV3-Luc) were injected subcutaneously into BALB/c nude mice. Bioluminescent imaging(BLI) was performed to detect tumor location and growth. COC183 B2-Cy7 at 1.1,3.3, 10, or 30 μg were used for in vivo fluorescence imaging, and phosphate-buffered saline(PBS), free Cy7 dye and mouse isotype immunoglobulin G(IgG)-Cy7(delivered at the same doses as COC183 B2-Cy7) were used as controls.Results: The expression of OC183 B2 with a high H-score was more prevalent in OC tissue than fallopian tube(FT) tissue. Among 417 OC patients, the expression of OC183 B2 was significantly correlated with the histological subtype, histological grade, residual tumor size, relapse state and survival status. IF staining demonstrated that COC183 B2 specifically expressed in SKOV3 cells but not HeLa cells. In vivo NIR fluorescence imaging indicated that COC183 B2-Cy7 was mainly distributed in the xenograft and liver with optimal tumor-to-background(T/B)ratios in the xenograft at 30 μg dose. The highest fluorescent signals in the tumor were observed at 96 h postinjection(hpi). Ex vivo fluorescence imaging revealed the fluorescent signals mainly from the tumor and liver. IHC analysis confirmed that xenografts were OC183 B2 positive.Conclusions: COC183 B2 is a good candidate for NIR fluorescence imaging and imaging-guided surgery in OC.展开更多
The interleukin-11(IL-11)and the IL-11 receptorα-subunit(IL-11Rα)have been demonstrated to regulate the invasion and proliferation of tumor cells.Our study intends to evaluate a noninvasive imaging of IL-11Rαexpres...The interleukin-11(IL-11)and the IL-11 receptorα-subunit(IL-11Rα)have been demonstrated to regulate the invasion and proliferation of tumor cells.Our study intends to evaluate a noninvasive imaging of IL-11Rαexpression in breast tumors using near-infrared(NIR)fluorescent dye Cy7-labeled IL-11 mimic peptide CGRRAGGSC.This work evaluated the IL-11Rαexpression of breast tumor cells and the binding status of this peptide to IL-11Rαin vitro and in vivo by using Western blotting,immunofluorescence staining and near-infrared fluorescence imaging.Our biochemical study showed that IL-11Rαwas overexpressed in breast tumor cells(MCF-7).The cell-binding assay demonstrated specific binding of peptide CGRRAGGSC to MCF-7 cells in vitro.In vivo imaging results showed that NIR fluorescent signals of Cy7-CGRRAGGSC were selectively accumulated in tumor and metabolic organs.While in the blocking experiment,free CGRRAGGSC obviously blocked the concentration of the Cy7-CGRRAGGSC in the tumors.These results suggested that IL-11Rαmay be used as a potential target for noninvasive imaging in IL-11Rαoverexpressed tumors.Furthermore,the imaging agent of near-infrared fluorescent dye Cy7-labeled CGRRAGGSC is suitable for IL-11Rαexpression imaging study in vivo.展开更多
Semiconducting conjugated polymer nanoparticles(SPNs)represent an emerging class of phototheranostic materi-als with great promise for cancer treatment.In this report,low-bandgap electron donoracceptor(DA)-conjugated ...Semiconducting conjugated polymer nanoparticles(SPNs)represent an emerging class of phototheranostic materi-als with great promise for cancer treatment.In this report,low-bandgap electron donoracceptor(DA)-conjugated SPNs with sur-face cloaked by red blood cell membrane(RBCM)are developed for highly e ective photoacoustic imaging and photothermal therapy.The resulting RBCM-coated SPN(SPN@RBCM)displays remarkable near-infrared light absorption and good photosta-bility,as well as high photothermal conver-sion e ciency for photoacoustic imaging and photothermal therapy.Particularly,due to the small size(<5 nm),SPN@RBCM has the advantages of deep tumor penetration and rapid clearance from the body with no appreciable toxicity.The RBCM endows the SPNs with prolonged systematic circulation time,less reticuloendothelial system uptake and reduced immune-recognition,hence improving tumor accumulation after intravenous injection,which provides strong photoacoustic signals and exerts excellent photothermal therapeutic e ects.Thus,this work provides a valuable paradigm for safe and highly e cient tumor pho-toacoustic imaging and photothermal therapy for further clinical translation.展开更多
This study was undertaken to investigate the feasibility of near-infrared(NIR) hyperspectral imaging(1 000–2 500 nm) for non-destructive and quantitative prediction of protein content in peanut kernels. Partial least...This study was undertaken to investigate the feasibility of near-infrared(NIR) hyperspectral imaging(1 000–2 500 nm) for non-destructive and quantitative prediction of protein content in peanut kernels. Partial least squares regression(PLSR) calibration model was established between the spectral data extracted from the hyperspectral images and the reference measured protein content values, with the coefficient of determination of prediction(R_P^2) of 0.885 and root mean square error of prediction(RMSEP) of 0.465%.Regression coefficients(RC) from PLSR analysis were used to identify the most essential wavelengths that had the greatest influence on changes in the protein content. Eight optimal wavelengths were selected by RC and its corresponding simplified RC-PLSR prediction model was also obtained, showing better performance with a higher R_P^2 of 0.870 and a lower RMSEP of 0.494%. The results indicate that hyperspectral imaging with PLSR analysis can be used as a rapid and non-destructive method for predicting protein content in peanut.展开更多
The application to detect ilally added drugs in dietary supplerments by near-infrared spectral imaging was studied with the focus on nifedipine,diclofenac and metformin.The method is based on near-infrared spectral im...The application to detect ilally added drugs in dietary supplerments by near-infrared spectral imaging was studied with the focus on nifedipine,diclofenac and metformin.The method is based on near-infrared spectral images correlation cofficient to detect ilally added drugs.The results comply 100%with HPLC methods test results with no false positive results.展开更多
Polarimetric imaging enhances the ability to distinguish objects from a bright background by detecting their particular polarization status,which offers another degree of freedom in infrared remote sensing.However,to ...Polarimetric imaging enhances the ability to distinguish objects from a bright background by detecting their particular polarization status,which offers another degree of freedom in infrared remote sensing.However,to scale up by monolithically integrating grating-based polarizers onto a focal plane array(FPA)of infrared detectors,fundamental technical obstacles must be overcome,including reductions of the extinction ratio by the misalignment between the polarizer and the detector,grating line width fluctuations,the line edge roughness,etc.This paper reports the authors’latest achievements in overcoming those problems by solving key technical issues regarding the integration of large-scale polarizers onto the chips of FPAs with individual indium gallium arsenide/indium phosphide(In Ga As/In P)sensors as the basic building blocks.Polarimetric and photovoltaic chips with divisions of the focal plane of 540×4 pixels and 320×256 superpixels have been successfully manufactured.Polarimetric imaging with enhanced contrast has been demonstrated.The progress made in this work has opened up a broad avenue toward industrialization of high quality polarimetric imaging in infrared wavelengths.展开更多
Near infrared chemical imaging(NIR-CI)combines conventional near infrared(NIR)spectros-copy with chemical imaging,thus provides spectral and spatial information simult aneously.It could be utilized to visualize the sp...Near infrared chemical imaging(NIR-CI)combines conventional near infrared(NIR)spectros-copy with chemical imaging,thus provides spectral and spatial information simult aneously.It could be utilized to visualize the spatial distribution of the ingredients in a sample.The data acquired using NIR CI instrument are hyperspectral data cube(hypercube)containing thousands of spectra.Chemometric methodologies are necessary to transform spectral information into chemical information.Partial least squares(PLS)method was performed to extract chemical information of chlorpheniramine maleate in pharmaceutical formulations.A series of samples which consisted of different CPM concentrations(w/w)were compressed and hypercube data were measured.The spectra extracted from the hypercube were used to establish the PLS model of CPM.The results of the model were R^(2)_(val)0.981,RMSEC 0.384%,RMSECV 0.483%,RMSEP 0.631%,indicating that this model was reliable.展开更多
文摘This review paper reports near-infrared(NIR)imaging studies using a newly-developed NIR camera,Compovision.Compovision can measure a significantly wide area of 150mm×250mm at high speed of between 2and 5s.It enables a wide spectral region measurement in the 1 000~2 350nm range at 6nm intervals.We investigated the potential of Compovision in the applications to industrial problems such as the evaluation of pharmaceutical tablets and polymers.Our studies have demonstrated that NIR imaging based on Compovision can solve several issues such as long acquisition times and relatively low sensitivity of detection.NIR imaging with Compovision is strongly expected to be applied not only to pharmaceutical tablet monitoring and polymer characterization but also to various applications such as those to food products,biomedical substances and organic and inorganic materials.
基金Scientic and Technological Research Council of Turkey(TUBITAK),under grand,No:113E771.
文摘Subcutaneous vein network plays important roles to maintain microcirculation that is related to some diagnostic aspects.Despite developments of optical imaging technologies,still the difficulties about deep skin vascular imaging have been continued.On the other hand,since hemoglobin con-centration of human blood has key role in the veins imaging by optical manner,the used wavelength in vascular imaging,must be chosen considering absorption of hemoglobin.In this research,we constructed a near infrared(NIR)light source because of lower absorption of hemoglobin in this optical region.To obtain vascular image,reflectance geometry was used.Next,from recorded images,vascular network analysis,such as calculation of width of vascular of interest and complexity of selected region were implemented.By comparing with other modalities,we observed that proposed imaging system has great advantages including nonionized radiation,moderate penetration depth of 0.5-3 mm and diameter of 1 mm,cost-effective and algorit hmic simplicity for analysis.
基金The authors gratefully acknowledge the support of the Swiss National Foundation(National Research Programme NRP 57)and like to thank Andreas Metz for his dedication.We thank Klaas Enno Stephan for supporting this study and Philips Healthcare for technical andfinancial support.We like to address special thanks to Elisabeth Moore from Philips Healthcare for providing and answering questions about the MRI stability test postprocessing software,to Dennis Hueber from ISS Inc.for answering questions about the ISS OxiplexTSTM and to Cornelia Hagmann for proofreading the manuscript.
文摘We present a novel optical sensor to acquire simultaneously functional near-infrared imaging(fNIRI)and functional magnetic resonance imaging(fMRI)data with an improved handling and direct localization in the MRI compared to available sensors.Quantitative phantom and interference measurements showed that both methods can be combined without reciprocal adverse effects.The direct localization of the optical sensor on MR images acquired with a T1-weighted echo sequence simplifies the co-registration of NIRI and MRI data.In addition,the optical sensor is simple to attach,which is crucial for measurements on vulnerable subjects.The fNIRI and T2^(*)-weighted fMRI data of a cerebral activation were simultaneously acquired proving the practicability of the setup.
文摘Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.
基金supported by the National Natural Science Foundation of China(Grant Nos.62375040 and 11974071)the Sichuan Science and Technology Program(Grant Nos.2022ZYD0108 and 2023JDRC0030).
文摘Optical memory effect-based speckle-correlated technology has been developed for reconstructing hidden objectsfrom disordered speckle patterns,achieving imaging through scattering layers.However,the lighting efficiency and fieldof view of existing speckle-correlated imaging systems are limited.Here,a near-infrared low spatial coherence fiberrandom laser illumination method is proposed to address the above limitations.Through the utilization of random Rayleighscattering within dispersion-shifted fibers to provide feedback,coupled with stimulated Raman scattering for amplification,a near-infrared fiber random laser exhibiting a high spectral density and extremely low spatial coherence is generated.Based on the designed fiber random laser,speckle-correlated imaging through scattering layers is achieved,with highlighting efficiency and a large imaging field of view.This work improves the performance of speckle-correlated imagingand enriches the research on imaging through scattering medium.
基金supported by the Thailand Research Fund through the Royal Golden Jubilee Ph.D.Program(PHD/0225/2561)the Faculty of Engineering,Kamphaeng Saen Campus,Kasetsart University,Thailand。
文摘The adulteration concentration of palm kernel oil(PKO)in virgin coconut oil(VCO)was quantified using near-infrared(NIR)hyperspectral imaging.Nowadays,some VCO is adulterated with lower-priced PKO to reduce production costs,which diminishes the quality of the VCO.This study used NIR hyperspectral imaging in the wavelength region 900-1,650 nm to create a quantitative model for the detection of PKO contaminants(0-100%)in VCO and to develop predictive mapping.The prediction equation for the adulteration of VCO with PKO was constructed using the partial least squares regression method.The best predictive model was pre-processed using the standard normal variate method,and the coefficient of determination of prediction was 0.991,the root mean square error of prediction was 2.93%,and the residual prediction deviation was 10.37.The results showed that this model could be applied for quantifying the adulteration concentration of PKO in VCO.The prediction adulteration concentration mapping of VCO with PKO was created from a calibration model that showed the color level according to the adulteration concentration in the range of 0-100%.NIR hyperspectral imaging could be clearly used to quantify the adulteration of VCO with a color level map that provides a quick,accurate,and non-destructive detection method.
基金supported by the National Key Research and Development Program of China(Nos.2019YFE03090100 and 2022YFE03100002)National Natural Science Foundation of China(No.12075241)。
文摘The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).
文摘The aim of this research was to determine the rice protein content utilizing a NIR imaging system.The developed imaging system utilized a NIR camera which installed automatically exchanged filters with the wavelength range from 870 nm to 1014 nm.Multiple liner regression(MLR),partial least square regression(PLSR),and artificial neural network(ANN)models were employed as data analysis methods for 6.18%-9.43%rice protein detections within both the NIR imaging system and commercial NIRS.A total of 180 rice samples were used in this study,of which 120 random samples were selected as a calibration set for the MLR and PLSR models.Moreover,for establishing the back-propagation ANN model,the same 120 samples were divided into two parts,80 samples were used for network training and the other 40 were established as the monitoring set.To compare with the results of MLR,PLSR,and ANN models,the remaining 60 of the total 180 samples were established as the validation set.Applying an MLR linear regression model composed of five wavelengths;the NIR imaging system successfully detected rice protein content.The predicting results of r_(val)^(2) and SEP were 0.769 and 0.294%,respectively.In PLSR model,utilizing the imaging system obtained the results of r_(val)^(2)=0.782,and SEP=0.274%within the wavelength range from 870 nm to 1014 nm.Five significant wavelengths selected by the MLR model were the same as the input data of the ANN model,and the prediction results were r_(val)^(2)=0.806,and SEP=0.266%.The prediction results indicated that the developed NIR imaging system has the advantages of simple,convenient operation,and high detection accuracy as well as it presents commercial potential in non-destructive detection of rice protein content.
文摘Historically,psychiatric diagnoses have been made based on patient’s reported symptoms applying the criteria from diagnostic and statistical manual of mental disorders.The utilization of neuroimaging or biomarkers to make the diagnosis and manage psychiatric disorders remains a distant goal.There have been several studies that examine brain imaging in psychiatric disorders,but more work is needed to elucidate the complexities of the human brain.In this editorial,we examine two articles by Xu et al and Stoyanov et al,that show developments in the direction of using neuroimaging to examine the brains of people with schizo-phrenia and depression.Xu et al used magnetic resonance imaging to examine the brain structure of patients with schizophrenia,in addition to examining neurotransmitter levels as biomarkers.Stoyanov et al used functional magnetic resonance imaging to look at modulation of different neural circuits by diagnostic-specific scales in patients with schizophrenia and depression.These two studies provide crucial evidence in advancing our understanding of the brain in prevalent psychiatric disorders.
基金supported by a grant from the Health Research New Zealand(HRC)22/559(to AJG and LB)。
文摘Moderate to severe perinatal hypoxic-ischemic encephalopathy occurs in~1 to 3/1000 live births in high-income countries and is associated with a significant risk of death or neurodevelopmental disability.Detailed assessment is important to help identify highrisk infants,to help families,and to support appropriate interventions.A wide range of monitoring tools is available to assess changes over time,including urine and blood biomarkers,neurological examination,and electroencephalography.At present,magnetic resonance imaging is unique as although it is expensive and not suited to monitoring the early evolution of hypoxic-ischemic encephalopathy by a week of life it can provide direct insight into the anatomical changes in the brain after hypoxic-ischemic encephalopathy and so offers strong prognostic information on the long-term outcome after hypoxic-ischemic encephalopathy.This review investigated the temporal dynamics of neonatal hypoxic-ischemic encephalopathy injuries,with a particular emphasis on exploring the correlation between the prognostic implications of magnetic resonance imaging scans in the first week of life and their relationship to long-term outcome prediction,particularly for infants treated with therapeutic hypothermia.A comprehensive literature search,from 2016 to 2024,identified 20 pertinent articles.This review highlights that while the optimal timing of magnetic resonance imaging scans is not clear,overall,it suggests that magnetic resonance imaging within the first week of life provides strong prognostic accuracy.Many challenges limit the timing consistency,particularly the need for intensive care and clinical monitoring.Conversely,although most reports examined the prognostic value of scans taken between 4 and 10 days after birth,there is evidence from small numbers of cases that,at times,brain injury may continue to evolve for weeks after birth.This suggests that in the future it will be important to explore a wider range of times after hypoxic-ischemic encephalopathy to fully understand the optimal timing for predicting long-term outcomes.
基金Supported by Natural Science Foundation of Shanghai,No.17ZR1431400National Key R and D Program of China,No.2017YFA0103902.
文摘Sotos syndrome is characterized by overgrowth features and is caused by alterations in the nuclear receptor binding SET domain protein 1 gene.Attentiondeficit/hyperactivity disorder(ADHD)is considered a neurodevelopment and psychiatric disorder in childhood.Genetic characteristics and clinical presentation could play an important role in the diagnosis of Sotos syndrome and ADHD.Magnetic resonance imaging(MRI)has been used to assess medical images in Sotos syndrome and ADHD.The images process is considered to display in MRI while wavelet fusion has been used to integrate distinct images for achieving more complete information in single image in this editorial.In the future,genetic mechanisms and artificial intelligence related to medical images could be used in the clinical diagnosis of Sotos syndrome and ADHD.
基金supported by the Research Project of the Shanghai Health Commission,No.2020YJZX0111(to CZ)the National Natural Science Foundation of China,Nos.82021002(to CZ),82272039(to CZ),82171252(to FL)+1 种基金a grant from the National Health Commission of People’s Republic of China(PRC),No.Pro20211231084249000238(to JW)Medical Innovation Research Project of Shanghai Science and Technology Commission,No.21Y11903300(to JG).
文摘Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism.This review provides a comprehensive summary of the latest developments in the application of presynaptic dopaminergic positron emission tomography imaging in disorders that manifest parkinsonism.We conducted a thorough literature search using reputable databases such as PubMed and Web of Science.Selection criteria involved identifying peer-reviewed articles published within the last 5 years,with emphasis on their relevance to clinical applications.The findings from these studies highlight that presynaptic dopaminergic positron emission tomography has demonstrated potential not only in diagnosing and differentiating various Parkinsonian conditions but also in assessing disease severity and predicting prognosis.Moreover,when employed in conjunction with other imaging modalities and advanced analytical methods,presynaptic dopaminergic positron emission tomography has been validated as a reliable in vivo biomarker.This validation extends to screening and exploring potential neuropathological mechanisms associated with dopaminergic depletion.In summary,the insights gained from interpreting these studies are crucial for enhancing the effectiveness of preclinical investigations and clinical trials,ultimately advancing toward the goals of neuroregeneration in parkinsonian disorders.
文摘Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of life of patients,several endeavors have been made toward precision medicine through image-guided surgery,allowing access to real-time intraoperative anatomy and accurate tumor staging.The goal of the surgeon is to achieve a more precise,individualized,and less invasive surgery without compromising oncological efficiency and safety.In this perspective,we have demonstrated the role of indocyanine green(ICG)and near-infrared(NIR)fluorescence imaging method in gastric cancer surgery.This technique may be used to improve localization of the tumor,detection of sentinel lymph nodes(SLN),real-time lymphatic mapping,and blood flow assessment(anastomosis perfusion).
基金supported by the National Key Research and Development Program of China (No.2016YFA0201400)National Natural Science Foundation of China (No. 81671431)
文摘Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determined by immunohistochemical(IHC) staining using tissue microarrays with the H-score system and immunofluorescence(IF) staining of tumor cell lines.Imaging probes with the NIR fluorescent dye cyanine 7(Cy7) conjugated to COC183 B2 Mab were chemically engineered. OC183 B2-positive human OC cells(SKOV3-Luc) were injected subcutaneously into BALB/c nude mice. Bioluminescent imaging(BLI) was performed to detect tumor location and growth. COC183 B2-Cy7 at 1.1,3.3, 10, or 30 μg were used for in vivo fluorescence imaging, and phosphate-buffered saline(PBS), free Cy7 dye and mouse isotype immunoglobulin G(IgG)-Cy7(delivered at the same doses as COC183 B2-Cy7) were used as controls.Results: The expression of OC183 B2 with a high H-score was more prevalent in OC tissue than fallopian tube(FT) tissue. Among 417 OC patients, the expression of OC183 B2 was significantly correlated with the histological subtype, histological grade, residual tumor size, relapse state and survival status. IF staining demonstrated that COC183 B2 specifically expressed in SKOV3 cells but not HeLa cells. In vivo NIR fluorescence imaging indicated that COC183 B2-Cy7 was mainly distributed in the xenograft and liver with optimal tumor-to-background(T/B)ratios in the xenograft at 30 μg dose. The highest fluorescent signals in the tumor were observed at 96 h postinjection(hpi). Ex vivo fluorescence imaging revealed the fluorescent signals mainly from the tumor and liver. IHC analysis confirmed that xenografts were OC183 B2 positive.Conclusions: COC183 B2 is a good candidate for NIR fluorescence imaging and imaging-guided surgery in OC.
基金Supported by National Natural Science Foundation of China (No.81202032)Key University Science Research Project of Jiangsu Province (No. 16KJB320004)+2 种基金Jiangsu Provincial Health and Family Planning Commission Foundation (No.Z201502)Jiangsu Provincial Health and Family Planning Research Projects (No.H2018029)Key Laboratory of Nuclear Medicine of the Ministry of Health, Jiangsu Provincial Key Laboratory of Molecular Nuclear Medicine (No.KF201501)
文摘The interleukin-11(IL-11)and the IL-11 receptorα-subunit(IL-11Rα)have been demonstrated to regulate the invasion and proliferation of tumor cells.Our study intends to evaluate a noninvasive imaging of IL-11Rαexpression in breast tumors using near-infrared(NIR)fluorescent dye Cy7-labeled IL-11 mimic peptide CGRRAGGSC.This work evaluated the IL-11Rαexpression of breast tumor cells and the binding status of this peptide to IL-11Rαin vitro and in vivo by using Western blotting,immunofluorescence staining and near-infrared fluorescence imaging.Our biochemical study showed that IL-11Rαwas overexpressed in breast tumor cells(MCF-7).The cell-binding assay demonstrated specific binding of peptide CGRRAGGSC to MCF-7 cells in vitro.In vivo imaging results showed that NIR fluorescent signals of Cy7-CGRRAGGSC were selectively accumulated in tumor and metabolic organs.While in the blocking experiment,free CGRRAGGSC obviously blocked the concentration of the Cy7-CGRRAGGSC in the tumors.These results suggested that IL-11Rαmay be used as a potential target for noninvasive imaging in IL-11Rαoverexpressed tumors.Furthermore,the imaging agent of near-infrared fluorescent dye Cy7-labeled CGRRAGGSC is suitable for IL-11Rαexpression imaging study in vivo.
基金supported by the National Natural Science Foundation of China(Grant Nos.61727823,51873160)the joint research project of Health and Education Commission of Fujian Province(Grant No.2019-WJ-20).
文摘Semiconducting conjugated polymer nanoparticles(SPNs)represent an emerging class of phototheranostic materi-als with great promise for cancer treatment.In this report,low-bandgap electron donoracceptor(DA)-conjugated SPNs with sur-face cloaked by red blood cell membrane(RBCM)are developed for highly e ective photoacoustic imaging and photothermal therapy.The resulting RBCM-coated SPN(SPN@RBCM)displays remarkable near-infrared light absorption and good photosta-bility,as well as high photothermal conver-sion e ciency for photoacoustic imaging and photothermal therapy.Particularly,due to the small size(<5 nm),SPN@RBCM has the advantages of deep tumor penetration and rapid clearance from the body with no appreciable toxicity.The RBCM endows the SPNs with prolonged systematic circulation time,less reticuloendothelial system uptake and reduced immune-recognition,hence improving tumor accumulation after intravenous injection,which provides strong photoacoustic signals and exerts excellent photothermal therapeutic e ects.Thus,this work provides a valuable paradigm for safe and highly e cient tumor pho-toacoustic imaging and photothermal therapy for further clinical translation.
基金Supported by the Natural Science Foundation of Guangdong Province(2017A030310558)China Postdoctoral Science Foundation(2017M612672)Fundamental Research Funds for the Central Universities(2017MS067)
文摘This study was undertaken to investigate the feasibility of near-infrared(NIR) hyperspectral imaging(1 000–2 500 nm) for non-destructive and quantitative prediction of protein content in peanut kernels. Partial least squares regression(PLSR) calibration model was established between the spectral data extracted from the hyperspectral images and the reference measured protein content values, with the coefficient of determination of prediction(R_P^2) of 0.885 and root mean square error of prediction(RMSEP) of 0.465%.Regression coefficients(RC) from PLSR analysis were used to identify the most essential wavelengths that had the greatest influence on changes in the protein content. Eight optimal wavelengths were selected by RC and its corresponding simplified RC-PLSR prediction model was also obtained, showing better performance with a higher R_P^2 of 0.870 and a lower RMSEP of 0.494%. The results indicate that hyperspectral imaging with PLSR analysis can be used as a rapid and non-destructive method for predicting protein content in peanut.
基金support of National Science and Technology Support Program (2012BAK08B02)Beijing Institute for Drug Control and Jiangsu Institute for Food and Drug Control for their generous providing of dietary supplements samples.
文摘The application to detect ilally added drugs in dietary supplerments by near-infrared spectral imaging was studied with the focus on nifedipine,diclofenac and metformin.The method is based on near-infrared spectral images correlation cofficient to detect ilally added drugs.The results comply 100%with HPLC methods test results with no false positive results.
基金financially supported by the following projects:Open project of SITP(Project Number:IIMDKFJJ-18-09)National Natural Science Foundation of China(Project Number:61927820)+2 种基金The STCSM2019-11-20 funding(Project Number:19142202700)National Natural Science Foundation of China(Project Number:NSF No.U1732104)Zhejiang Lab’s International Talent Fund for Young Professionals。
文摘Polarimetric imaging enhances the ability to distinguish objects from a bright background by detecting their particular polarization status,which offers another degree of freedom in infrared remote sensing.However,to scale up by monolithically integrating grating-based polarizers onto a focal plane array(FPA)of infrared detectors,fundamental technical obstacles must be overcome,including reductions of the extinction ratio by the misalignment between the polarizer and the detector,grating line width fluctuations,the line edge roughness,etc.This paper reports the authors’latest achievements in overcoming those problems by solving key technical issues regarding the integration of large-scale polarizers onto the chips of FPAs with individual indium gallium arsenide/indium phosphide(In Ga As/In P)sensors as the basic building blocks.Polarimetric and photovoltaic chips with divisions of the focal plane of 540×4 pixels and 320×256 superpixels have been successfully manufactured.Polarimetric imaging with enhanced contrast has been demonstrated.The progress made in this work has opened up a broad avenue toward industrialization of high quality polarimetric imaging in infrared wavelengths.
基金supported from Beijing Municipal Government for the university a±liated with the Party Central Committee(Prof.Shi)National Natural Science Foundation of China(81303218)+1 种基金Doctoral Fund of Ministry of Education of China(20130013120006)Special Fund of Beijing University of Chinese Medicine(Manfei Xu).
文摘Near infrared chemical imaging(NIR-CI)combines conventional near infrared(NIR)spectros-copy with chemical imaging,thus provides spectral and spatial information simult aneously.It could be utilized to visualize the spatial distribution of the ingredients in a sample.The data acquired using NIR CI instrument are hyperspectral data cube(hypercube)containing thousands of spectra.Chemometric methodologies are necessary to transform spectral information into chemical information.Partial least squares(PLS)method was performed to extract chemical information of chlorpheniramine maleate in pharmaceutical formulations.A series of samples which consisted of different CPM concentrations(w/w)were compressed and hypercube data were measured.The spectra extracted from the hypercube were used to establish the PLS model of CPM.The results of the model were R^(2)_(val)0.981,RMSEC 0.384%,RMSECV 0.483%,RMSEP 0.631%,indicating that this model was reliable.