期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
The optimal distance between two electrode tips during recording of compound nerve action potentials in the rat median nerve
1
作者 Yongping Li Jie Lao +3 位作者 Xin Zhao Dong Tian Yi Zhu Xiaochun Wei 《Neural Regeneration Research》 SCIE CAS CSCD 2014年第2期171-178,共8页
The distance between the two electrode tips can greatly influence the parameters used for record- ing compound nerve action potentials. To investigate the optimal parameters for these recordings in the rat median nerv... The distance between the two electrode tips can greatly influence the parameters used for record- ing compound nerve action potentials. To investigate the optimal parameters for these recordings in the rat median nerve, we dissociated the nerve using different methods and compound nerve action potentials were orthodromically or antidromically recorded with different electrode spac- ings. Compound nerve action potentials could be consistently recorded using a method in which the middle part of the median nerve was intact, with both ends dissociated from the surrounding fascia and a ground wire inserted into the muscle close to the intact part. When the distance be- tween two stimulating electrode tips was increased, the threshold and supramaximal stimulating intensity of compound nerve action potentials were gradually decreased, but the amplitude was not changed significantly. When the distance between two recording electrode tips was increased, the amplitude was gradually increased, but the threshold and supramaximal stimulating intensity exhibited no significant change. Different distances between recording and stimulating sites did not produce significant effects on the aforementioned parameters. A distance of 5 mm between recording and stimulating electrodes and a distance of 10 mm between recording and stimulating sites were found to be optimal for compound nerve action potential recording in the rat median nerve. In addition, the orthodromic compound action potential, with a biphasic waveform that was more stable and displayed less interference (however also required a higher threshold and higher supramaximal stimulus), was found to be superior to the antidromic compound action potential. 展开更多
关键词 nerve regeneration peripheral nerve injury compound nerve action potential mediannerve electrodes AMPLITUDE supramaximal stimulus intensity recording electrode the Project 211in China neural regeneration
下载PDF
COMPOUND ACTION POTENTIAL OF PERIPHERAL NERVE BY MES AND CES ABOUT DIFFERENCES OF TECHNICAL CHAKACTERISTICS
2
作者 LlU Hongguang ZHOU Lin JIANG Dazong(Research Institute of Biomed. Eng, Xi’an Jiaotong Uni. Xi’an 710049, China)(Shannxi Normal University (now Japan x 630-8485, Nara University) 《Chinese Journal of Biomedical Engineering(English Edition)》 1999年第3期54-55,共2页
关键词 action COMPOUND action potential OF PERIPHERAL nerve BY MES AND CES ABOUT DIFFERENCES OF TECHNICAL CHAKACTERISTICS MES CES
下载PDF
Berrettini Anastomosis Iatrogenic Injury Relating to Carpel Tunnel Syndrome Case Study
3
作者 Maha Farhina 《International Journal of Clinical Medicine》 CAS 2022年第11期494-500,共7页
Some diseases require medical mitigation following the diagnosis, and sometimes the situation means that the patient has to undertake strong medication. However, this medicine is designed pharmacodynamically to intera... Some diseases require medical mitigation following the diagnosis, and sometimes the situation means that the patient has to undertake strong medication. However, this medicine is designed pharmacodynamically to interact with other organs before they reach the intended organ. Some mitigation imposes challenges on the involved organ. While the main organ will be healed, some drugs’ footprints will be left out to other organs. These are called iatrogenic injuries. In the case of anastomosis, it requires the alteration of surgical methods or the origin of iatrogenic injury in the arm;thus, the knowledge of anastomosis is very important to the field of medical practice. In addition, carpal tunnel release becomes vital in curing carpal tunnel syndrome. The paper focuses on a case of a 42-year-old woman found to have a complication to her middle finger. This case becomes important for studying Berrettini anastomosis iatrogenic injury, which relates to carpal tunnel syndrome. The Berrettini branch is a complication that facilitates communication between the superficial ulnar and median nerve. The analysis also provides the electro-diagnostic evidence of Berrettini anastomosis on how it can give a position three-finger and thus contribute to a force explanation of the median neuropraxia. Lastly, the paper provides information on the implication of the Berrettini branch for surgical use. The implication of pictures in the digital era can be used to analyze the varied connection and length between the median nerve and ulnar section. It’s easy to locate the position of high risk of iatrogenic injury in the palm due to the consistent location of Berrettini communication branches. The precaution is that operations have to be conducted moderately for a clear vision as the carefully mitigated practice ensures protection from the destruction and injury of the surrounding structures. 展开更多
关键词 Iatrogenic Injury Berrettini Anastomosis (BA) SNAP-Sensory nerve action potential CTS-Carpal Tunnel Syndrome Median nerve Ulnar nerve
下载PDF
上一页 1 下一页 到第