期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Inter-Observer Reliability of Fused Time-of-Flight MR Angiography and 3D Steady State Sequence versus 3D Contrast Enhanced Images in Evaluation of Neurovascular Compression
1
作者 Mohamed Mahmoud Elsherbini Ali Hassan Elmokadem +2 位作者 Ahmed El-Morsy Fatma Mohamed Sherif Amr Farid Khalil 《Open Journal of Modern Neurosurgery》 2022年第2期86-96,共11页
Purpose: Is to evaluate the accuracy of fused 3D time-of-flight (TOF) MR angiography and 3D Steady-State sequence (FIESTA) versus 3D contrast-enhanced T1 weighted images in evaluation of neurovascular compression via ... Purpose: Is to evaluate the accuracy of fused 3D time-of-flight (TOF) MR angiography and 3D Steady-State sequence (FIESTA) versus 3D contrast-enhanced T1 weighted images in evaluation of neurovascular compression via an inter-observer agreement protocol. Methods: Patients presented with trigeminal neuralgia, tinnitus, or facial hemispasm were examined using 3D-TOF-MRA, 3D-FIESTA, and 3D contrast-enhanced T1WI of the cerebellopontine angle to assess neurovascular compression. Two independent readers assessed the location, signal alteration, offending vascular structure, and grade of neurovascular compression using fused 3D-TOF-MRA and 3D-FIESTA versus contrast-enhanced T1 weighted images. The Kappa test for interobserver agreement was done. Results: The final study cohort consisted of 56 patients (42 females and 14 males) with a mean age of 38.25 ± 1.94. AICA was the offending vessel for 32 (57.1%) patients. The most common offending nerve was the trigeminal nerve in 26 patients, followed by facial/vestibulocochlear complex in 18 patients, and solely the 8th nerve in 12 patients. All three grades of compression were encountered in this study with percentages of 48.2% (27/56), 30.3% (17/56), and 21.4% (12/56) for grades I, II, III respectively. Fused TOF and steady-state images, and contrast-enhanced images showed perfect agreement for detection of the side of compression, the relation between nerve and vascular loop, offended neural segment, and offending vessel, while showing good agreement regarding the degree of compression. Conclusion: Fused TOF and steady-state images provide sufficient data to diagnose and grade microvascular compression syndromes comparable to contrast-enhanced images. 展开更多
关键词 neurovascular compression Trigeminal Neuralgia Microvascular Decompression TINNITUS VERTIGO Hemifacial Spasm
下载PDF
Three-dimensional time-of-flight magnetic resonance angiography combined with high resolution T2-weighted imaging in preoperative evaluation of microvascular decompression 被引量:1
2
作者 Chen Liang Ling Yang +2 位作者 Bin-Bin Zhang Shi-Wen Guo Rui-Chun Li 《World Journal of Clinical Cases》 SCIE 2022年第34期12594-12604,共11页
BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and H... BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD. 展开更多
关键词 Three-dimensional time-of-flight magnetic resonance angiography High resolution T2 weighted imaging neurovascular compression Microvascular decompression META-ANALYSIS
下载PDF
Prevalence of nerve-vessel contact at cisternal segments of the oculomotor nerve in asymptomatic patients evaluated with magnetic resonance images 被引量:2
3
作者 WANG Jin GONG Xiang-yang +1 位作者 SUN Yi HU Xing-yue 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第8期989-992,共4页
Background Some studies indicated that cases of idiopathic oculomotor nerve palsy can be explained by vascular compression of the oculomotor nerve. Vascular contact with or compression to the cisternal segment of the ... Background Some studies indicated that cases of idiopathic oculomotor nerve palsy can be explained by vascular compression of the oculomotor nerve. Vascular contact with or compression to the cisternal segment of the oculomotor nerve has been reported frequently in asymptomatic individuals. In this study, we retrospectively analyzed the relationship between the oculomotor nerve's cisternal segment and adjacent arteries in asymptomatic patients and the prevalence of this occurrence via magnetic resonance imaging (MRI). Method MRI of bilateral oculomotor nerves in 93 asymptomatic patients were reviewed. The oculomotor nerve-artery relationship was evaluated and classified from levels 1 to 3, representing the degrees of contact on oblique transverse and oblique sagittal reconstructed MRI. Prevalence of the nerve-artery relationship at each level was described. The correlation between the nerve-vessel relationship (levels) and the age was analyzed by Spearman's rank correlation analysis. Results Cisternal segment of the oculomotor nerve did not have contact with any artery (level 1) in 27.4% (51/186) nerves. One hundred nerves made contact with at least one artery (level 2), but their shapes or configurations were not changed; 35 nerves (18.8%) were displaced or distorted due to artery compression (level 3). The posterior cerebral artery had the greatest incidence of making contact with or compressing the cisternal segment of the oculomotor nerve (58.1%). No significant correlation between nerve-vessel relationship (levels) and the age was found in this study. Conclusions Whether oculomotor nerve contact with or compression by one or more arteries is of high prevalence in asymptomatic individuals as evidenced by MRI examination. There is no correlation with individual age. Discretion should be used when making an etiological diagnosis of vascular compression for patients with oculomotor nerve palsy. Further investigation of other causes is warranted. 展开更多
关键词 neurovascular compression oculomotor nerve magnetic resonance imaging
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部