Background Coronary artery fistula (CAF) is a rare anomaly.Transcatheter CAF closure has been introduced using various materials,but only few data are available on the Guglielmi detachable coil (GDC).The advantage...Background Coronary artery fistula (CAF) is a rare anomaly.Transcatheter CAF closure has been introduced using various materials,but only few data are available on the Guglielmi detachable coil (GDC).The advantage of using GDC for transcatheter CAF closure is more controllable,therefore much safer when compared to other coils.This report is about our experience in transcatheter closure of CAF using fibered GDC in our hospital.Methods & Results From 2002 to 2007,there were 10 patients with CAFs (age range:28 to 56 year-old,7 males) who underwent transcatheter CAF closure.There were a total of 19 CAFs which originated from right coronary (n =5),left circumflex (n =3),left anterior descending artery (n =10) and left main trunk (n =1).Median number of coil deployment for each fistula was 3 (range:1 to 6).The pulmonary artery was the most common site of the distal communication of CAFs (n =14),followed by right atrium (n =3),left atrium (n =1) and left ventricle (n =1).Immediate coronary angiography after GDC deployment revealed no residual shunt in 12 (63.2%) CAFs,significant reduction of the flow in 5 (26.3%),while 2 (10.5%) could not be closed due to small size.Nine (90%) patients underwent a repeated angiography within 3 to 8 months.Among 12 CAFs that were occluded immediately post-deployment,there were 2 CAFs with insignificant residual flow.Among 6 CAFs with significantly decreased flow immediately post-deployment,2 were occluded totally in the follow-up angiography.In total,12 (70.5%) CAFs were occluded completely and 5 (29.5%) CAFs still had insignificant residual flow,which did not need any additional coil deployment.During a mean follow up of 4.3 ± 0.7 year,all patients remained symptom and complication free.Conclusions The fibered GDC is a safe and effective method for percutaneous closure of the CAFs.展开更多
We present a case report about percutaneous closure of a congenital Gerbode defect using Nit-Occlud~? Lê VSD coil. The patient was referred to our hospital with a diagnosis of ventricular septal defect(VSD) and s...We present a case report about percutaneous closure of a congenital Gerbode defect using Nit-Occlud~? Lê VSD coil. The patient was referred to our hospital with a diagnosis of ventricular septal defect(VSD) and severe pulmonary arterial hypertension. But transthoracic echocardiography revealed a communication between the left ventricle(LV) and the right atrial(RA), called Gerbode defect. Catheterization confirmed the shunt from the LV to the RA. We successfully closed the defect with a VSD coil. After uneventful 6 mo follow-up, the patient was out of dyspnea, the symptom urged him to have medical attention. This case report is to discuss the diagnosis and percutaneous treatment approach for this rare congenital heart disease.展开更多
Purpose To improve the method of PDA closuremanipulation for occluding larger PDAs with the diameter】5mm Method:For 3 patients after perforating the femoral artery,a guiding wire wasintroduced into the aortic atery a...Purpose To improve the method of PDA closuremanipulation for occluding larger PDAs with the diameter】5mm Method:For 3 patients after perforating the femoral artery,a guiding wire wasintroduced into the aortic atery and past through the PDA.Along the wirea balloon catheter was adopted to explore the real internal eiameter and thedistensibility of the PDA.Using a multi-usable catheter which remade fromthe coronary angiographic catheter and had a relative larger cavity was easyto push the coil.Result:The diameters of 3 patients were 6.0,6.3 and40 minutes.A small shunt existed in only one case and disappeared onemonth late.Conclusion:The improved method is safe and valuable forclmical application.展开更多
文摘Background Coronary artery fistula (CAF) is a rare anomaly.Transcatheter CAF closure has been introduced using various materials,but only few data are available on the Guglielmi detachable coil (GDC).The advantage of using GDC for transcatheter CAF closure is more controllable,therefore much safer when compared to other coils.This report is about our experience in transcatheter closure of CAF using fibered GDC in our hospital.Methods & Results From 2002 to 2007,there were 10 patients with CAFs (age range:28 to 56 year-old,7 males) who underwent transcatheter CAF closure.There were a total of 19 CAFs which originated from right coronary (n =5),left circumflex (n =3),left anterior descending artery (n =10) and left main trunk (n =1).Median number of coil deployment for each fistula was 3 (range:1 to 6).The pulmonary artery was the most common site of the distal communication of CAFs (n =14),followed by right atrium (n =3),left atrium (n =1) and left ventricle (n =1).Immediate coronary angiography after GDC deployment revealed no residual shunt in 12 (63.2%) CAFs,significant reduction of the flow in 5 (26.3%),while 2 (10.5%) could not be closed due to small size.Nine (90%) patients underwent a repeated angiography within 3 to 8 months.Among 12 CAFs that were occluded immediately post-deployment,there were 2 CAFs with insignificant residual flow.Among 6 CAFs with significantly decreased flow immediately post-deployment,2 were occluded totally in the follow-up angiography.In total,12 (70.5%) CAFs were occluded completely and 5 (29.5%) CAFs still had insignificant residual flow,which did not need any additional coil deployment.During a mean follow up of 4.3 ± 0.7 year,all patients remained symptom and complication free.Conclusions The fibered GDC is a safe and effective method for percutaneous closure of the CAFs.
文摘We present a case report about percutaneous closure of a congenital Gerbode defect using Nit-Occlud~? Lê VSD coil. The patient was referred to our hospital with a diagnosis of ventricular septal defect(VSD) and severe pulmonary arterial hypertension. But transthoracic echocardiography revealed a communication between the left ventricle(LV) and the right atrial(RA), called Gerbode defect. Catheterization confirmed the shunt from the LV to the RA. We successfully closed the defect with a VSD coil. After uneventful 6 mo follow-up, the patient was out of dyspnea, the symptom urged him to have medical attention. This case report is to discuss the diagnosis and percutaneous treatment approach for this rare congenital heart disease.
文摘Purpose To improve the method of PDA closuremanipulation for occluding larger PDAs with the diameter】5mm Method:For 3 patients after perforating the femoral artery,a guiding wire wasintroduced into the aortic atery and past through the PDA.Along the wirea balloon catheter was adopted to explore the real internal eiameter and thedistensibility of the PDA.Using a multi-usable catheter which remade fromthe coronary angiographic catheter and had a relative larger cavity was easyto push the coil.Result:The diameters of 3 patients were 6.0,6.3 and40 minutes.A small shunt existed in only one case and disappeared onemonth late.Conclusion:The improved method is safe and valuable forclmical application.