As part of the enhanced recovery after surgery (ERAS) protocol, the goal-directed fluid management with hemodynamic monitoring can effectively guide perioperative fluid use and significantly improve the outcomes in ...As part of the enhanced recovery after surgery (ERAS) protocol, the goal-directed fluid management with hemodynamic monitoring can effectively guide perioperative fluid use and significantly improve the outcomes in highrisk patients undergoing major surgeries. Several minimally invasive and non-invasive monitoring devices are commercially available for clinical use. As part of an internal evaluation, we reported the results from three different hemodynamic monitoring devices used in a patient undergoing a major abdominal surgery.展开更多
Objective:To explore the effect of continuous non-invasive blood pressure monitoring on intraoperative hemodynamics and postoperative myocardial injury in craniotomy.Methods:120 cases of elective craniotomy were divid...Objective:To explore the effect of continuous non-invasive blood pressure monitoring on intraoperative hemodynamics and postoperative myocardial injury in craniotomy.Methods:120 cases of elective craniotomy were divided into the self-control group(continuous non-invasive blood pressure monitoring and intermittent cuff non-invasive blood pressure monitoring,CNAP group)and propensity score matching group(only intermittent cuff non-invasive blood pressure measurement in previous craniotomy,PSM group);Goal-directed hemodynamic management in CNAP group included heart rate(HR),blood pressure(BP),stroke volume(SV),stroke variability(SVV),and systemic vascular resistance index(SVRI).The main index is to compare the troponin level within 72 hours after operation between the CNAP group and the PSM group;The secondary indicators are the comparison of the hemodynamic conditions between the CNAP group and the PSM at 10 specific time points.Results:The incidence of postoperative myocardial injury in the CNAP group was significantly lower than that in the PSM group(12%vs.30%,P=0.01);in the CNAP group hypotensive episodes(6 vs.3,P=0.01),positive balance of fluid therapy(700 vs.500 mL,P<0.001),more use of vasoactive drugs(29 vs.18,P=0.04),more stable hemodynamics medical status(P=0.03)were recorded.Conclusion:The hemodynamic management strategy based on continuous non-invasive blood pressure monitoring can reduce the incidence of myocardial injury after elective craniotomy and maintain a more stable hemodynamic state.展开更多
Objective: To investigate the effects of exogenous recombinant human brain natriuretic peptide(rh BNP) after primary percutaneous coronary intervention(PCI) on non-invasive hemodynamic in acute myocardial infarction p...Objective: To investigate the effects of exogenous recombinant human brain natriuretic peptide(rh BNP) after primary percutaneous coronary intervention(PCI) on non-invasive hemodynamic in acute myocardial infarction patients with left ventricular failure. Methods: A number of 96 acute myocardial infarction patients accompanied with heart failure after PCI hospitalized in the People's Hospital of Sanya during February 2012 to October 2015 were selected. They were randomly divided into the therapy group(n = 50) and control group(n = 46). On the basis of routine treatment, patients in the therapy group were treated with intravenous rh BNP(1.5 μg/kg was intravenous injection with uniform speed of 3 min, followed by continuous infusion 0.007 5 μg/kg·min for 72 h), while the control group received conventional treatment. Bio Z-2011 non-invasive hemodynamic real-time monitoring system was used to monitor the hemodynamic parameters changes and the leves of plasma pro-BNP, serum creatinine, serum potassium, serum sodium and urine volume of each group before and after treating for 30 min, 1 h, 3 h, 6 h, 12 h, 24 h, 48 h, 72 h. Results: Patients in the therapy group showed no effect on heart rate, while after 30 min of intravenous injection of rh BNP, CO, CI, SV, and SI increased significantly and LVET and TFC reduced at the same time, which had certain effect on blood pressure(SBP/DBP). Compared with the control group, the therapy group showed a faster and more effective improvement on haemodynamics. Conclusions: Acute myocardial infarction patients complicated with left heart failure after primary PCI can significantly improve hemodynamics by treating with rh BNP.展开更多
Septic shock in children is associated with high mortality and morbidity. Its management is time-sensitive and must be aggressive and target oriented. The use of clinical assessment alone to differentiate between cold...Septic shock in children is associated with high mortality and morbidity. Its management is time-sensitive and must be aggressive and target oriented. The use of clinical assessment alone to differentiate between cold and warm shock and to select the appropriate inotropic and vasoactive medications is fraught with errors. Semiquantitative and quantitative assessment of the preload,contractility and afterload using non-invasive tools has been suggested,in conjunction with clinical and laboratory assessment,to direct shock management and select between vasopressors,vasodilators and inotropes or a combination of these drugs. This review aims to describe non-invasive tools to assess the hemodynamic status in septic shock including echocardiography,trans-thoracic/trans-esophageal Doppler and electrical cardiometry. As septic shock is a dynamic condition that changes markedly overtime,frequent or continuous measurement of the cardiac output(CO),systemic vascular resistance(SVR) and other hemodynamic parameters using the above-mentioned tools is essential to personalize the treatment and adapt it over time. The different combinations of blood pressure,CO and SVR serve as a pathophysiological framework to manage fl-uid therapy and titrate inotropic and vasoactive drugs. Near infrared spectroscopy is introduced as a noninvasive method to measure end organ perfusion and assess the response to treatment.展开更多
The clinical course ofchronic liver diseases is significantly dependent on the progression rate and the extent offibrosis, i.e. the non-structured replacement of necrotic parenchyma by extracellular matrix. Fibrogenes...The clinical course ofchronic liver diseases is significantly dependent on the progression rate and the extent offibrosis, i.e. the non-structured replacement of necrotic parenchyma by extracellular matrix. Fibrogenesis, i.e. the development offibrosis can be regarded as an unlimited wound healing process, which is based on matrix (connective tissue) synthesis in activated hepatic stellate cells, fibroblasts (fibrocytes), hepatocytes and biliary epithelial cells, which are converted to matrix-producing (myo-)fibroblasts by a process defined as epithelial-mesenchymal transition. Blood (noninvasive) biomarkers offibrogenesis and fibrosis can be divided into class and class analytes. Class biomarkers are those single tests, which are based on the pathophysiology offibrosis, whereas class biomarkers aremostly multiparametric algorithms, which have been statistically evaluated with regard to the detection and activity ofongoing fibrosis. Currently available markers fulfil the criteria ofideal clinical-chemical tests only partially, but increased understanding ofthe complex pathogenesis offibrosis offers additional ways for pathophysiologically well based serum (plasma) biomarkers. They include TGF-β-driven marker proteins, bone marrow-derived cells (fibrocytes), and cytokines, which govern proand anti-fibrotic activities. Proteomic and glycomic approaches ofserum are under investigation to set up specific protein or carbohydrate profiles in patients with liver fibrosis. These and other novel parameters will supplement or eventually replaceliver biopsy/histology, high resolution imaging analysis, and elastography for the detection and monitoring of patients at risk ofdeveloping liver fibrosis.展开更多
Hemodynamic monitoring has long formed the cornerstone of heart failure(HF) and pulmonary hypertension diagnosis and management. We review the long history of invasive hemodynamic monitors initially using pulmonary ar...Hemodynamic monitoring has long formed the cornerstone of heart failure(HF) and pulmonary hypertension diagnosis and management. We review the long history of invasive hemodynamic monitors initially using pulmonary artery(PA) pressure catheters in the hospital setting, to evaluating the utility of a number of implantable devices that can allow for ambulatory determination of intracardiac pressures. Although the use of indwelling PA catheters has fallen out of favor in a number of settings, implantable devices have afforded clinicians an opportunity for objective determination of a patient's volume status and pulmonary pressures. Some devices, such as the CardioM EMS and thoracic impedance monitors present as part of implantable cardiac defibrillators, are supported by a body of evidence which show the potential to reduce HF related morbidity and have received regulatory approval, whereas other devices have failed to show benefit and, in some cases, harm. Clearly these devices can convey a considerable amount of information and clinicians should start to familiarize themselves with their use and expect further development and refinement in the future.展开更多
To study monitoring hemodynamics and oxygen dynamics of adult respiratory distress syndrome (ARDS) secondary to high altitude pulmonary edema (HAPE),we performed clinic and laboratory studies in 8 patients who prelimi...To study monitoring hemodynamics and oxygen dynamics of adult respiratory distress syndrome (ARDS) secondary to high altitude pulmonary edema (HAPE),we performed clinic and laboratory studies in 8 patients who preliminarily developed high altitude cerebral edema (HACE) and then ARDS occurred at an altitude of 4 500 m. After an initial emergency treatment on high mountains,all the patients were rapidly transported to a hospital at a lower altitude of 2 808 m. The right cardiac catheterizations were carried out within 5 h after hospitalized. The monitoring hemodynamics and oxygen dynamics were studied via a thermodilution Swan-Gaze catheter. The results showed that before treatments at the beginning of monitoring,there presented a significant pulmonary artery hypertension with a decreased cardiac function,and a lower oxygen metabolism in all the 8 patients. However,after some effective treatments,including mechanical ventilation and using dexamethasone,furosemide,etc,four days later the result of a repeated monitoring showed that their pulmonary artery pressure had been decreased with an improved cardiac function with all the oxygen metabolic indexes increased significantly. Our studies suggested that performing monitoring hemodynamics in patients with ARDS secondary to HAPE will define the clinical therapeutic measures which will benefit the outcome.展开更多
Systemic blood circulation is one of life activity’s most important physiological functions.Continuous noninvasive hemodynamicmonitoring is essential for the management of cardiovascular status.However,it is difficul...Systemic blood circulation is one of life activity’s most important physiological functions.Continuous noninvasive hemodynamicmonitoring is essential for the management of cardiovascular status.However,it is difficult to achieve systemichemodynamic monitoring with the daily use of current devices due to the lack of multichannel and time-synchronized operationcapability over the whole body.Here,we utilize a soft microfiber Bragg grating group to monitor spatiotemporalhemodynamics by taking advantage of the high sensitivity,electromagnetic immunity,and great temporal synchronizationbetween multiple remote sensor nodes.A continuous systemic hemodynamic measurement technique is developedusing all-mechanical physiological signals,such as ballistocardiogram signals and pulse waves,to illustrate the actualmechanical process of blood circulation.Multiple hemodynamic parameters,such as systemic pulse transit time,heartrate,blood pressure,and peripheral resistance,are monitored using skin-like microfiber Bragg grating patches conformallyattached at different body locations.Relying on the soft microfiber Bragg grating group,the spatiotemporal hemodynamicmonitoring technique opens up new possibilities in clinical medical diagnosis and daily health management.展开更多
Despite the development of noninvasive tools as echocardiography,right-sided heart catheterization remains an integral part of the cardiovascular evaluation.In the last decade,better understanding of the hemodynamic p...Despite the development of noninvasive tools as echocardiography,right-sided heart catheterization remains an integral part of the cardiovascular evaluation.In the last decade,better understanding of the hemodynamic process before heart failure decompensation led to improvement of outpatient strategies to prevent it.Advances in implantable wireless technology now allow frequent and direct measurement of intracardiac fi lling pressures,which can be monitored by health care providers to help tailor therapy to reduce fi lling pressures and hospital readmission rates.展开更多
Objective: To compare the haemodynamic effects of the induction agents ketamine, etomidate and sevoflurane using the model of electrical velocimetry based cardiac output monitoring in paediatric cardiac surgical patie...Objective: To compare the haemodynamic effects of the induction agents ketamine, etomidate and sevoflurane using the model of electrical velocimetry based cardiac output monitoring in paediatric cardiac surgical patients. Design: Prospective randomized study. Setting: Tertiary care hospital. Participants: 60 children < 2 years age undergoing cardiac surgery. Interventions: The patients were randomized into 3 equal groups to receive 1.5-2.5 mg/kg iv ketamine (group K), 0.2-0.3 mg/kg iv etomidate (group E) or upto 8% sevoflurane (group S) as the induction agent. Hemodynamic parameters were noted before and after induction of anaesthesia utilizing a noninvasive cardiac monitor based on the model of electrical velocimetry. Measurements and Main Results: The demographic characteristics of the patients were similar in the three groups. The HR decreased in all groups, least in group E (P ≤ 0.01) but the MAP decreased only in group S (P ≤ 0.001). In group S, the stroke volume improved from 9 ± 3.2 ml to 10 ± 3.2 ml (P ≤ 0.05) and the stroke volume variation decreased from 25% ± 6.4% to 13% ± 6.2% (P ≤ 0.001). The stroke index and systemic arterial saturation improved in all groups (P ≤ 0.01). The cardiac index and index of contractility were unchanged. The transthoracic fluid content reduced in groups E and S, but did not change in group K (P ≤ 0.05). Conclusions: Etomidate appeared to provide the most stable conditions for induction of anesthesia in children undergoing cardiac surgery, followed by ketamine and sevoflurane.展开更多
AIM:To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening.METHODS:Sleep-disordered breathing(SDB) is associated with cardi...AIM:To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening.METHODS:Sleep-disordered breathing(SDB) is associated with cardiovascular disease.Patients with existing cardiovascular disease may have unrecognized SDB or may develop SDB while under the care of a cardiologist.A screening device for SDB,easy to use and appealing to cardiologists,would assist in referral of appropriate patients for full polysomnography(PSG).A cardiac and respiratory monitor(CPAM) was attached to patients undergoing PSG and an apnea/hypopnea index(AHI) generated.The CPAM device produced respiration rate,snoring rate,individual apnea/hypopnea events and an SDB severity score(SDBSS).In addition to AHI,an expert over-reader annotated individual breaths,snores and SDB breathing events to which the automated algorithms were compared.RESULTS:The test set consisted of data from 85 patients(age:50.5 ± 12.4 years).Of these,57 had a positive PSG defined as AHI ≥ 5.0(mean:30.0 ± 29.8,negative group mean:1.5 ± 1.2).The sensitivity and specificity of the SDBSS compared to AHI was 57.9% and 89.3%,respectively.The correlation of snoring rate by CPAM compared to the expert overreader was r = 0.58(mean error:1.52 snores/min),while the automated respiration rate had a correlation of r = 0.90(mean error:0.70 breaths/min).CONCLUSION:This performance assessment shows that CPAM can be a useful portable monitor for screening and follow-up of subjects for SDB.展开更多
Background Heart failure is a significant problem leading to repeated hospitalizations. Telemonitoring and hemodynamic monitoring have demonstrated success in reducing hospitalization rates, but not all studies report...Background Heart failure is a significant problem leading to repeated hospitalizations. Telemonitoring and hemodynamic monitoring have demonstrated success in reducing hospitalization rates, but not all studies reported significant effects. The aim of this systematic review and meta-analysis is to examine the effectiveness of telemonitoring and wireless hemodynamic monitoring devices in reducing hospitalizations in heart failure. Methods & Results PubMed and Cochrane Library were searched up to 1st May 2017 for articles that investigated the effects of telemonitoring or hemodynamic monitoring on hospitalization rates in heart failure. In 31,501 patients (mean age: 68 ± 12 years; 61% male; follow-up 11 ± 8 months), telemonitoring reduced hospitalization rates with a HR of 0.73 (95% CI: 0.65-0.83; P 〈 0.0001) with significant heterogeneity (I2 = 94%). These effects were observed in the short-term (≤ 6 months: HR = 0.77, 95% CI: 0.65-0.89; P 〈 0.01) and long-term (≥ 12 months: HR = 0.73, 95% CI: 0.62-0.87; P 〈 0.0001). In 4831 patients (mean age 66 ± 18 years; 66% male; follow-up 13 ± 4 months), wireless hemodynamic monitoring also reduced hospitalization rates with a HR of 0.60 (95% CI: 0.53-0.69; P 〈 0.001) with significant heterogeneity (I2 = 64%).This reduction was observed both in the short-term (HR = 0.55, 95% CI: 0.45-0.68; P 〈 0.001; I2 = 72%) and long-term (HR = 0.64, 95% CI: 0.57-0.72; P 〈 0.001; I2 = 55%). Conclusions Telemonitoring and hemodynamic monitoring reduce hospitalization in both short- and long-term in heart failure patients展开更多
Intraoperative fluid management is pivotal to the outcome and success of surgery, especially in high-risk proce- dures. Empirical formula and invasive static monitoring have been traditionally used to guide intraopera...Intraoperative fluid management is pivotal to the outcome and success of surgery, especially in high-risk proce- dures. Empirical formula and invasive static monitoring have been traditionally used to guide intraoperative fluid management and assess volume status. With the awareness of the potential complications of invasive procedures and the poor reliability of these methods as indicators of volume status, we present a case scenario of a patient who underwent major abdominal surgery as an example to discuss how the use of minimally invasive dynamic monitoring may guide intraoperative fluid therapy.展开更多
Objective: Few studies are available on the hemodynamic changes acutely determined by Primary Percutaneous Coronary Intervention (PCI) in ST-Elevation Myocardial Infarction (STEMI) patients, probably for the difficult...Objective: Few studies are available on the hemodynamic changes acutely determined by Primary Percutaneous Coronary Intervention (PCI) in ST-Elevation Myocardial Infarction (STEMI) patients, probably for the difficult evaluation of hemodynamic variables in this acute setting. Therefore, the paper is to evaluate the variations of several hemodynamic parameters determined by PCI using PRAM (Pressure Recording Analytical Method), minimally invasive hemodynamic monitoring. Methods: We analyzed in 20 STEMI patients submitted to PCI several hemodynamic variables, assessed with PRAM from radial/ femoral artery, 3-minute before PCI and at endprocedure. Variables measures were: systolic, diastolic, dicrotic and mean arterial pressures;heart rate (HR);stroke volume (SV);systemic vascular resistance (SVR);dP/dtmax;cardiac cycle efficiency (CCE). Results: In our patients HR, SVR and dP/dtmax decreased significantly (85 ± 6.3 to 77 ± 4.5, p = 0.002;1738 ± 241 to 1450 ± 253, p = 0.022;1.22 ± 0.11 to 1.11 ± 0.12, p = 0.007, respectively) while CCE and SV increased significantly (?0.25 ± 0.23 to ?0.01 ± 0.12,展开更多
AIM: To assess whether Most Care is able to detect the cardiovascular alterations in response to physiological stress (posture). METHODS: Non invasive hemodynamic was assessed in 26 cirrhotic patients compared to heal...AIM: To assess whether Most Care is able to detect the cardiovascular alterations in response to physiological stress (posture). METHODS: Non invasive hemodynamic was assessed in 26 cirrhotic patients compared to healthy subjects, both in the supine and standing positions. RESULTS: In baseline conditions, when compared to healthy subjects, cirrhotic patients showed significantly lower values of dicrotic and diastolic pressures and systemic vascular resistance. While in the standing position, cirrhotic patients showed higher values of cardiac index, stroke volume index and cardiac cycle efficiency. When returning to the supine position, cirrhotic patients exhibited lower values of dicrotic and diastolic pressures and systemic vascular resistance in the presence of higher values of cardiac index, stroke volume index and cardiac cycle efficiency. CONCLUSION: Most Care proved to be able to detect cardiovascular abnormalities bedside in the resting state and after postural challenge in cirrhotic patients.展开更多
Failure of an automated blood pressure cuff to deflate when a patient is under general anesthesia can lead to catastrophic consequences if unnoticed for more than three hours [1]. We present this as a hearsay case in ...Failure of an automated blood pressure cuff to deflate when a patient is under general anesthesia can lead to catastrophic consequences if unnoticed for more than three hours [1]. We present this as a hearsay case in which an automated blood pressure cuff of the Spacelabs Ultraview Clinical Workstation monitor (model No. 90385) applied pressure for about five hours resulting in limb thrombosis. In order to analyze this catastrophe, simulation scenarios were tested to elucidate the possible errors and malfunctions that may have led to this injury. We present the analysis of the advantages and validity of the hearsay case report. We also include our proposed criteria that should be required when a hearsay case is considered for publication.展开更多
With the rise in prevalence of Type II diabetes throughout the world, an increasing need for a portable monitoring system for both blood glucose and lipoprotein concentrations is in demand. Recent work has led to non-...With the rise in prevalence of Type II diabetes throughout the world, an increasing need for a portable monitoring system for both blood glucose and lipoprotein concentrations is in demand. Recent work has led to non-invasive wearable devices for monitoring changes in blood glucose concentrations using electromagnetic (EM) waves. However, this still fall short as a means of monitoring cholesterol levels in diabetic patients. The EM study on human tissues emphasized here may also relate to the safety guidelines applied to cellular communications, power lines, and other EM applications. The specific absorption rate (SAR) for the power of the non-ionizing frequency must not exceed a threshold as it impacts DNA and can lead to cancerous tissues. In this study, we used COMSOL software for the investigation of the viability of using EM within the frequency range of 64 MHz-1 GHz as a means of monitoring the transmission properties of human blood and lipoprotein. In this approach, wave equations were solved within blood and lipoprotein boundaries. Research parameters, including frequency range, Power input (SAR), and lipoprotein densities, were investigated. The transmission properties, produced by the electrical and thermal characteristics of these physiological parameters, have led to proper diagnosis of lipoprotein density. Within the frequency range of 64 MHz to 1 GHz, and for a power range of 0.1 to 0.6 SAR, lipoprotein density from 1.00 g/mL to 1.20 g/mL was considered. A 2D model, with an antenna source that supplied the electromagnetic waves to human tissues, was created for the simulations. These were used for the study of the transmission properties of the EM energy into the blood and lipoprotein tissues. While the range of magnetic flux values between simulations varies only slightly or not at all, the distribution of these values is impacted by given parameters. As such, a device capable of comparing magnetic flux values and penetration depths could easily distinguish between samples of different lipoprotein densities. The results obtained in this study can be accommodated non-invasively by human tissues, and can be produced in a practical model using wearable devices. A practical model is proposed for future consideration.展开更多
Multimodal monitoring(MMM)in the intensive care unit(ICU)has become increasingly sophisticated with the integration of neurophysical principles.However,the challenge remains to select and interpret the most appropriat...Multimodal monitoring(MMM)in the intensive care unit(ICU)has become increasingly sophisticated with the integration of neurophysical principles.However,the challenge remains to select and interpret the most appropriate combination of neuromonitoring modalities to optimize patient outcomes.This manuscript reviewed current neuromonitoring tools,focusing on intracranial pressure,cerebral electrical activity,metabolism,and invasive and noninvasive autoregulation moni-toring.In addition,the integration of advanced machine learning and data science tools within the ICU were discussed.Invasive monitoring includes analysis of intracranial pressure waveforms,jugular venous oximetry,monitoring of brain tissue oxygenation,thermal diffusion flowmetry,electrocorticography,depth electroencephalography,and cerebral microdialysis.Noninvasive measures include transcranial Doppler,tympanic membrane displacement,near-infrared spectroscopy,optic nerve sheath diameter,positron emission tomography,and systemic hemodynamic monitoring including heart rate variability analysis.The neurophysical basis and clinical relevance of each method within the ICU setting were examined.Machine learning algorithms have shown promise by helping to analyze and interpret data in real time from continuous MMM tools,helping clinicians make more accurate and timely decisions.These algorithms can integrate diverse data streams to generate predictive models for patient outcomes and optimize treatment strategies.MMM,grounded in neurophysics,offers a more nuanced understanding of cerebral physiology and disease in the ICU.Although each modality has its strengths and limitations,its integrated use,especially in combination with machine learning algorithms,can offer invaluable information for individualized patient care.展开更多
Convenient non-invasive flow monitoring would facilitate the operation and control in microfluidic chips,but is challenging due to the small space of microchannels and complex operation required in traditional optical...Convenient non-invasive flow monitoring would facilitate the operation and control in microfluidic chips,but is challenging due to the small space of microchannels and complex operation required in traditional optical methods.In this work,we propose a novel non-invasive strategy to probe microfluidic flows via streaming potential phenomenon.By sealing one side of the microchannel with a piece of hydrogel film,streaming potential inside the channel can be clearly detected by electrodes at outer surface of the hydrogel due to ion diffusion in the hydrogel.Flow is detected without sensors contacting with the internal liquid.Moreover,the electrodes shape like a tiny probe,which can move around mapping the flow distribution in a chip with the spatial resolution of 1 mm and flow rate detection limit of 3μL·min–1.Bubbles inside the channels can also be detected,due to the fluctuation of streaming voltage when gas-liquid interface flows through the electrode,showing an easy and potential way for multi-functional flow monitoring in microfluidic chips.展开更多
Human metabolite moisture detection is important in health monitoring and non-invasive diagnosis.However,ultra-sensitive quantitative extraction of respiration information in real-time remains a great challenge.Herein...Human metabolite moisture detection is important in health monitoring and non-invasive diagnosis.However,ultra-sensitive quantitative extraction of respiration information in real-time remains a great challenge.Herein,chemiresistors based on imine-linked covalent organic framework(COF)films with dual-active sites are fabricated to address this issue,which demonstrates an amplified humidity-sensing signal performance.By regulation of monomers and functional groups,these COF films can be pre-engineered to achieve high response,wide detection range,fast response,and recovery time.Under the condition of relative humidity ranging from 13 to 98%,the COFTAPB-DHTA film-based humidity sensor exhibits outstanding humidity sensing perfor-mance with an expanded response value of 390 times.Furthermore,the response values of the COF film-based sensor are highly linear to the relative humidity in the range below 60%,reflecting a quantitative sensing mechanism at the molecular level.Based on the dual-site adsorption of the(-C=N-)and(C-N)stretching vibrations,the revers-ible tautomerism induced by hydrogen bonding with water molecules is demonstrated to be the main intrinsic mechanism for this effective humidity detection.In addition,the synthesized COF films can be further exploited to effectively detect human nasal and oral breathing as well as fabric permeability,which will inspire novel designs for effective humidity-detection devices.展开更多
文摘As part of the enhanced recovery after surgery (ERAS) protocol, the goal-directed fluid management with hemodynamic monitoring can effectively guide perioperative fluid use and significantly improve the outcomes in highrisk patients undergoing major surgeries. Several minimally invasive and non-invasive monitoring devices are commercially available for clinical use. As part of an internal evaluation, we reported the results from three different hemodynamic monitoring devices used in a patient undergoing a major abdominal surgery.
文摘Objective:To explore the effect of continuous non-invasive blood pressure monitoring on intraoperative hemodynamics and postoperative myocardial injury in craniotomy.Methods:120 cases of elective craniotomy were divided into the self-control group(continuous non-invasive blood pressure monitoring and intermittent cuff non-invasive blood pressure monitoring,CNAP group)and propensity score matching group(only intermittent cuff non-invasive blood pressure measurement in previous craniotomy,PSM group);Goal-directed hemodynamic management in CNAP group included heart rate(HR),blood pressure(BP),stroke volume(SV),stroke variability(SVV),and systemic vascular resistance index(SVRI).The main index is to compare the troponin level within 72 hours after operation between the CNAP group and the PSM group;The secondary indicators are the comparison of the hemodynamic conditions between the CNAP group and the PSM at 10 specific time points.Results:The incidence of postoperative myocardial injury in the CNAP group was significantly lower than that in the PSM group(12%vs.30%,P=0.01);in the CNAP group hypotensive episodes(6 vs.3,P=0.01),positive balance of fluid therapy(700 vs.500 mL,P<0.001),more use of vasoactive drugs(29 vs.18,P=0.04),more stable hemodynamics medical status(P=0.03)were recorded.Conclusion:The hemodynamic management strategy based on continuous non-invasive blood pressure monitoring can reduce the incidence of myocardial injury after elective craniotomy and maintain a more stable hemodynamic state.
基金supported by Science and Education Project of Hainan Province Health and Family Planning administrationand Sanya Health and Technology Innovation Project(NO.2015YW19)
文摘Objective: To investigate the effects of exogenous recombinant human brain natriuretic peptide(rh BNP) after primary percutaneous coronary intervention(PCI) on non-invasive hemodynamic in acute myocardial infarction patients with left ventricular failure. Methods: A number of 96 acute myocardial infarction patients accompanied with heart failure after PCI hospitalized in the People's Hospital of Sanya during February 2012 to October 2015 were selected. They were randomly divided into the therapy group(n = 50) and control group(n = 46). On the basis of routine treatment, patients in the therapy group were treated with intravenous rh BNP(1.5 μg/kg was intravenous injection with uniform speed of 3 min, followed by continuous infusion 0.007 5 μg/kg·min for 72 h), while the control group received conventional treatment. Bio Z-2011 non-invasive hemodynamic real-time monitoring system was used to monitor the hemodynamic parameters changes and the leves of plasma pro-BNP, serum creatinine, serum potassium, serum sodium and urine volume of each group before and after treating for 30 min, 1 h, 3 h, 6 h, 12 h, 24 h, 48 h, 72 h. Results: Patients in the therapy group showed no effect on heart rate, while after 30 min of intravenous injection of rh BNP, CO, CI, SV, and SI increased significantly and LVET and TFC reduced at the same time, which had certain effect on blood pressure(SBP/DBP). Compared with the control group, the therapy group showed a faster and more effective improvement on haemodynamics. Conclusions: Acute myocardial infarction patients complicated with left heart failure after primary PCI can significantly improve hemodynamics by treating with rh BNP.
文摘Septic shock in children is associated with high mortality and morbidity. Its management is time-sensitive and must be aggressive and target oriented. The use of clinical assessment alone to differentiate between cold and warm shock and to select the appropriate inotropic and vasoactive medications is fraught with errors. Semiquantitative and quantitative assessment of the preload,contractility and afterload using non-invasive tools has been suggested,in conjunction with clinical and laboratory assessment,to direct shock management and select between vasopressors,vasodilators and inotropes or a combination of these drugs. This review aims to describe non-invasive tools to assess the hemodynamic status in septic shock including echocardiography,trans-thoracic/trans-esophageal Doppler and electrical cardiometry. As septic shock is a dynamic condition that changes markedly overtime,frequent or continuous measurement of the cardiac output(CO),systemic vascular resistance(SVR) and other hemodynamic parameters using the above-mentioned tools is essential to personalize the treatment and adapt it over time. The different combinations of blood pressure,CO and SVR serve as a pathophysiological framework to manage fl-uid therapy and titrate inotropic and vasoactive drugs. Near infrared spectroscopy is introduced as a noninvasive method to measure end organ perfusion and assess the response to treatment.
文摘The clinical course ofchronic liver diseases is significantly dependent on the progression rate and the extent offibrosis, i.e. the non-structured replacement of necrotic parenchyma by extracellular matrix. Fibrogenesis, i.e. the development offibrosis can be regarded as an unlimited wound healing process, which is based on matrix (connective tissue) synthesis in activated hepatic stellate cells, fibroblasts (fibrocytes), hepatocytes and biliary epithelial cells, which are converted to matrix-producing (myo-)fibroblasts by a process defined as epithelial-mesenchymal transition. Blood (noninvasive) biomarkers offibrogenesis and fibrosis can be divided into class and class analytes. Class biomarkers are those single tests, which are based on the pathophysiology offibrosis, whereas class biomarkers aremostly multiparametric algorithms, which have been statistically evaluated with regard to the detection and activity ofongoing fibrosis. Currently available markers fulfil the criteria ofideal clinical-chemical tests only partially, but increased understanding ofthe complex pathogenesis offibrosis offers additional ways for pathophysiologically well based serum (plasma) biomarkers. They include TGF-β-driven marker proteins, bone marrow-derived cells (fibrocytes), and cytokines, which govern proand anti-fibrotic activities. Proteomic and glycomic approaches ofserum are under investigation to set up specific protein or carbohydrate profiles in patients with liver fibrosis. These and other novel parameters will supplement or eventually replaceliver biopsy/histology, high resolution imaging analysis, and elastography for the detection and monitoring of patients at risk ofdeveloping liver fibrosis.
文摘Hemodynamic monitoring has long formed the cornerstone of heart failure(HF) and pulmonary hypertension diagnosis and management. We review the long history of invasive hemodynamic monitors initially using pulmonary artery(PA) pressure catheters in the hospital setting, to evaluating the utility of a number of implantable devices that can allow for ambulatory determination of intracardiac pressures. Although the use of indwelling PA catheters has fallen out of favor in a number of settings, implantable devices have afforded clinicians an opportunity for objective determination of a patient's volume status and pulmonary pressures. Some devices, such as the CardioM EMS and thoracic impedance monitors present as part of implantable cardiac defibrillators, are supported by a body of evidence which show the potential to reduce HF related morbidity and have received regulatory approval, whereas other devices have failed to show benefit and, in some cases, harm. Clearly these devices can convey a considerable amount of information and clinicians should start to familiarize themselves with their use and expect further development and refinement in the future.
基金"973"National Key Basic Research and Development Program(No.2012CB518202)Project of Qinghai Development of Science and Technology(No.2011-N-150)
文摘To study monitoring hemodynamics and oxygen dynamics of adult respiratory distress syndrome (ARDS) secondary to high altitude pulmonary edema (HAPE),we performed clinic and laboratory studies in 8 patients who preliminarily developed high altitude cerebral edema (HACE) and then ARDS occurred at an altitude of 4 500 m. After an initial emergency treatment on high mountains,all the patients were rapidly transported to a hospital at a lower altitude of 2 808 m. The right cardiac catheterizations were carried out within 5 h after hospitalized. The monitoring hemodynamics and oxygen dynamics were studied via a thermodilution Swan-Gaze catheter. The results showed that before treatments at the beginning of monitoring,there presented a significant pulmonary artery hypertension with a decreased cardiac function,and a lower oxygen metabolism in all the 8 patients. However,after some effective treatments,including mechanical ventilation and using dexamethasone,furosemide,etc,four days later the result of a repeated monitoring showed that their pulmonary artery pressure had been decreased with an improved cardiac function with all the oxygen metabolic indexes increased significantly. Our studies suggested that performing monitoring hemodynamics in patients with ARDS secondary to HAPE will define the clinical therapeutic measures which will benefit the outcome.
基金supported by the National Key R&D Program of China(2021YFA1401103)the National Natural Science Foundation of China(61925502 and 51772145).
文摘Systemic blood circulation is one of life activity’s most important physiological functions.Continuous noninvasive hemodynamicmonitoring is essential for the management of cardiovascular status.However,it is difficult to achieve systemichemodynamic monitoring with the daily use of current devices due to the lack of multichannel and time-synchronized operationcapability over the whole body.Here,we utilize a soft microfiber Bragg grating group to monitor spatiotemporalhemodynamics by taking advantage of the high sensitivity,electromagnetic immunity,and great temporal synchronizationbetween multiple remote sensor nodes.A continuous systemic hemodynamic measurement technique is developedusing all-mechanical physiological signals,such as ballistocardiogram signals and pulse waves,to illustrate the actualmechanical process of blood circulation.Multiple hemodynamic parameters,such as systemic pulse transit time,heartrate,blood pressure,and peripheral resistance,are monitored using skin-like microfiber Bragg grating patches conformallyattached at different body locations.Relying on the soft microfiber Bragg grating group,the spatiotemporal hemodynamicmonitoring technique opens up new possibilities in clinical medical diagnosis and daily health management.
文摘Despite the development of noninvasive tools as echocardiography,right-sided heart catheterization remains an integral part of the cardiovascular evaluation.In the last decade,better understanding of the hemodynamic process before heart failure decompensation led to improvement of outpatient strategies to prevent it.Advances in implantable wireless technology now allow frequent and direct measurement of intracardiac fi lling pressures,which can be monitored by health care providers to help tailor therapy to reduce fi lling pressures and hospital readmission rates.
文摘Objective: To compare the haemodynamic effects of the induction agents ketamine, etomidate and sevoflurane using the model of electrical velocimetry based cardiac output monitoring in paediatric cardiac surgical patients. Design: Prospective randomized study. Setting: Tertiary care hospital. Participants: 60 children < 2 years age undergoing cardiac surgery. Interventions: The patients were randomized into 3 equal groups to receive 1.5-2.5 mg/kg iv ketamine (group K), 0.2-0.3 mg/kg iv etomidate (group E) or upto 8% sevoflurane (group S) as the induction agent. Hemodynamic parameters were noted before and after induction of anaesthesia utilizing a noninvasive cardiac monitor based on the model of electrical velocimetry. Measurements and Main Results: The demographic characteristics of the patients were similar in the three groups. The HR decreased in all groups, least in group E (P ≤ 0.01) but the MAP decreased only in group S (P ≤ 0.001). In group S, the stroke volume improved from 9 ± 3.2 ml to 10 ± 3.2 ml (P ≤ 0.05) and the stroke volume variation decreased from 25% ± 6.4% to 13% ± 6.2% (P ≤ 0.001). The stroke index and systemic arterial saturation improved in all groups (P ≤ 0.01). The cardiac index and index of contractility were unchanged. The transthoracic fluid content reduced in groups E and S, but did not change in group K (P ≤ 0.05). Conclusions: Etomidate appeared to provide the most stable conditions for induction of anesthesia in children undergoing cardiac surgery, followed by ketamine and sevoflurane.
基金Supported by An equipment grant from Inovise Medical,Inc.,Beaverton OR,United States,for clinical data collection
文摘AIM:To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening.METHODS:Sleep-disordered breathing(SDB) is associated with cardiovascular disease.Patients with existing cardiovascular disease may have unrecognized SDB or may develop SDB while under the care of a cardiologist.A screening device for SDB,easy to use and appealing to cardiologists,would assist in referral of appropriate patients for full polysomnography(PSG).A cardiac and respiratory monitor(CPAM) was attached to patients undergoing PSG and an apnea/hypopnea index(AHI) generated.The CPAM device produced respiration rate,snoring rate,individual apnea/hypopnea events and an SDB severity score(SDBSS).In addition to AHI,an expert over-reader annotated individual breaths,snores and SDB breathing events to which the automated algorithms were compared.RESULTS:The test set consisted of data from 85 patients(age:50.5 ± 12.4 years).Of these,57 had a positive PSG defined as AHI ≥ 5.0(mean:30.0 ± 29.8,negative group mean:1.5 ± 1.2).The sensitivity and specificity of the SDBSS compared to AHI was 57.9% and 89.3%,respectively.The correlation of snoring rate by CPAM compared to the expert overreader was r = 0.58(mean error:1.52 snores/min),while the automated respiration rate had a correlation of r = 0.90(mean error:0.70 breaths/min).CONCLUSION:This performance assessment shows that CPAM can be a useful portable monitor for screening and follow-up of subjects for SDB.
文摘Background Heart failure is a significant problem leading to repeated hospitalizations. Telemonitoring and hemodynamic monitoring have demonstrated success in reducing hospitalization rates, but not all studies reported significant effects. The aim of this systematic review and meta-analysis is to examine the effectiveness of telemonitoring and wireless hemodynamic monitoring devices in reducing hospitalizations in heart failure. Methods & Results PubMed and Cochrane Library were searched up to 1st May 2017 for articles that investigated the effects of telemonitoring or hemodynamic monitoring on hospitalization rates in heart failure. In 31,501 patients (mean age: 68 ± 12 years; 61% male; follow-up 11 ± 8 months), telemonitoring reduced hospitalization rates with a HR of 0.73 (95% CI: 0.65-0.83; P 〈 0.0001) with significant heterogeneity (I2 = 94%). These effects were observed in the short-term (≤ 6 months: HR = 0.77, 95% CI: 0.65-0.89; P 〈 0.01) and long-term (≥ 12 months: HR = 0.73, 95% CI: 0.62-0.87; P 〈 0.0001). In 4831 patients (mean age 66 ± 18 years; 66% male; follow-up 13 ± 4 months), wireless hemodynamic monitoring also reduced hospitalization rates with a HR of 0.60 (95% CI: 0.53-0.69; P 〈 0.001) with significant heterogeneity (I2 = 64%).This reduction was observed both in the short-term (HR = 0.55, 95% CI: 0.45-0.68; P 〈 0.001; I2 = 72%) and long-term (HR = 0.64, 95% CI: 0.57-0.72; P 〈 0.001; I2 = 55%). Conclusions Telemonitoring and hemodynamic monitoring reduce hospitalization in both short- and long-term in heart failure patients
基金supported by the Department of Anesthesiologyand Pain MedicineUniversity of California Davis Health System+1 种基金SacramentoCA 95617 and NIH Grant(#UL1 TR000002)
文摘Intraoperative fluid management is pivotal to the outcome and success of surgery, especially in high-risk proce- dures. Empirical formula and invasive static monitoring have been traditionally used to guide intraoperative fluid management and assess volume status. With the awareness of the potential complications of invasive procedures and the poor reliability of these methods as indicators of volume status, we present a case scenario of a patient who underwent major abdominal surgery as an example to discuss how the use of minimally invasive dynamic monitoring may guide intraoperative fluid therapy.
文摘Objective: Few studies are available on the hemodynamic changes acutely determined by Primary Percutaneous Coronary Intervention (PCI) in ST-Elevation Myocardial Infarction (STEMI) patients, probably for the difficult evaluation of hemodynamic variables in this acute setting. Therefore, the paper is to evaluate the variations of several hemodynamic parameters determined by PCI using PRAM (Pressure Recording Analytical Method), minimally invasive hemodynamic monitoring. Methods: We analyzed in 20 STEMI patients submitted to PCI several hemodynamic variables, assessed with PRAM from radial/ femoral artery, 3-minute before PCI and at endprocedure. Variables measures were: systolic, diastolic, dicrotic and mean arterial pressures;heart rate (HR);stroke volume (SV);systemic vascular resistance (SVR);dP/dtmax;cardiac cycle efficiency (CCE). Results: In our patients HR, SVR and dP/dtmax decreased significantly (85 ± 6.3 to 77 ± 4.5, p = 0.002;1738 ± 241 to 1450 ± 253, p = 0.022;1.22 ± 0.11 to 1.11 ± 0.12, p = 0.007, respectively) while CCE and SV increased significantly (?0.25 ± 0.23 to ?0.01 ± 0.12,
文摘AIM: To assess whether Most Care is able to detect the cardiovascular alterations in response to physiological stress (posture). METHODS: Non invasive hemodynamic was assessed in 26 cirrhotic patients compared to healthy subjects, both in the supine and standing positions. RESULTS: In baseline conditions, when compared to healthy subjects, cirrhotic patients showed significantly lower values of dicrotic and diastolic pressures and systemic vascular resistance. While in the standing position, cirrhotic patients showed higher values of cardiac index, stroke volume index and cardiac cycle efficiency. When returning to the supine position, cirrhotic patients exhibited lower values of dicrotic and diastolic pressures and systemic vascular resistance in the presence of higher values of cardiac index, stroke volume index and cardiac cycle efficiency. CONCLUSION: Most Care proved to be able to detect cardiovascular abnormalities bedside in the resting state and after postural challenge in cirrhotic patients.
文摘Failure of an automated blood pressure cuff to deflate when a patient is under general anesthesia can lead to catastrophic consequences if unnoticed for more than three hours [1]. We present this as a hearsay case in which an automated blood pressure cuff of the Spacelabs Ultraview Clinical Workstation monitor (model No. 90385) applied pressure for about five hours resulting in limb thrombosis. In order to analyze this catastrophe, simulation scenarios were tested to elucidate the possible errors and malfunctions that may have led to this injury. We present the analysis of the advantages and validity of the hearsay case report. We also include our proposed criteria that should be required when a hearsay case is considered for publication.
文摘With the rise in prevalence of Type II diabetes throughout the world, an increasing need for a portable monitoring system for both blood glucose and lipoprotein concentrations is in demand. Recent work has led to non-invasive wearable devices for monitoring changes in blood glucose concentrations using electromagnetic (EM) waves. However, this still fall short as a means of monitoring cholesterol levels in diabetic patients. The EM study on human tissues emphasized here may also relate to the safety guidelines applied to cellular communications, power lines, and other EM applications. The specific absorption rate (SAR) for the power of the non-ionizing frequency must not exceed a threshold as it impacts DNA and can lead to cancerous tissues. In this study, we used COMSOL software for the investigation of the viability of using EM within the frequency range of 64 MHz-1 GHz as a means of monitoring the transmission properties of human blood and lipoprotein. In this approach, wave equations were solved within blood and lipoprotein boundaries. Research parameters, including frequency range, Power input (SAR), and lipoprotein densities, were investigated. The transmission properties, produced by the electrical and thermal characteristics of these physiological parameters, have led to proper diagnosis of lipoprotein density. Within the frequency range of 64 MHz to 1 GHz, and for a power range of 0.1 to 0.6 SAR, lipoprotein density from 1.00 g/mL to 1.20 g/mL was considered. A 2D model, with an antenna source that supplied the electromagnetic waves to human tissues, was created for the simulations. These were used for the study of the transmission properties of the EM energy into the blood and lipoprotein tissues. While the range of magnetic flux values between simulations varies only slightly or not at all, the distribution of these values is impacted by given parameters. As such, a device capable of comparing magnetic flux values and penetration depths could easily distinguish between samples of different lipoprotein densities. The results obtained in this study can be accommodated non-invasively by human tissues, and can be produced in a practical model using wearable devices. A practical model is proposed for future consideration.
文摘Multimodal monitoring(MMM)in the intensive care unit(ICU)has become increasingly sophisticated with the integration of neurophysical principles.However,the challenge remains to select and interpret the most appropriate combination of neuromonitoring modalities to optimize patient outcomes.This manuscript reviewed current neuromonitoring tools,focusing on intracranial pressure,cerebral electrical activity,metabolism,and invasive and noninvasive autoregulation moni-toring.In addition,the integration of advanced machine learning and data science tools within the ICU were discussed.Invasive monitoring includes analysis of intracranial pressure waveforms,jugular venous oximetry,monitoring of brain tissue oxygenation,thermal diffusion flowmetry,electrocorticography,depth electroencephalography,and cerebral microdialysis.Noninvasive measures include transcranial Doppler,tympanic membrane displacement,near-infrared spectroscopy,optic nerve sheath diameter,positron emission tomography,and systemic hemodynamic monitoring including heart rate variability analysis.The neurophysical basis and clinical relevance of each method within the ICU setting were examined.Machine learning algorithms have shown promise by helping to analyze and interpret data in real time from continuous MMM tools,helping clinicians make more accurate and timely decisions.These algorithms can integrate diverse data streams to generate predictive models for patient outcomes and optimize treatment strategies.MMM,grounded in neurophysics,offers a more nuanced understanding of cerebral physiology and disease in the ICU.Although each modality has its strengths and limitations,its integrated use,especially in combination with machine learning algorithms,can offer invaluable information for individualized patient care.
基金supported by the National Natural Science Foundation of China(Grant Nos.51976141,52006123,62161160311).
文摘Convenient non-invasive flow monitoring would facilitate the operation and control in microfluidic chips,but is challenging due to the small space of microchannels and complex operation required in traditional optical methods.In this work,we propose a novel non-invasive strategy to probe microfluidic flows via streaming potential phenomenon.By sealing one side of the microchannel with a piece of hydrogel film,streaming potential inside the channel can be clearly detected by electrodes at outer surface of the hydrogel due to ion diffusion in the hydrogel.Flow is detected without sensors contacting with the internal liquid.Moreover,the electrodes shape like a tiny probe,which can move around mapping the flow distribution in a chip with the spatial resolution of 1 mm and flow rate detection limit of 3μL·min–1.Bubbles inside the channels can also be detected,due to the fluctuation of streaming voltage when gas-liquid interface flows through the electrode,showing an easy and potential way for multi-functional flow monitoring in microfluidic chips.
基金supported by the National Key Research and Development Program of China(2022YFB3205500,and 2022YFC3104700)the National Natural Science Foundation of China(62101329 and 61971284)+4 种基金the Shanghai Sailing Program(21YF1421400)the Natural Science Foundation of Shanghai(23ZR1430100)the Oceanic Interdisciplinary Program of Shanghai Jiao Tong University(SL2020ZD203,SL2021MS006 and SL2020MS031)Scientific Research Fund of Second Institute of Oceanography,Ministry of Natural Resources of P.R.China(SL2003)Startup Fund for Youngman Research at Shanghai Jiao Tong University.
文摘Human metabolite moisture detection is important in health monitoring and non-invasive diagnosis.However,ultra-sensitive quantitative extraction of respiration information in real-time remains a great challenge.Herein,chemiresistors based on imine-linked covalent organic framework(COF)films with dual-active sites are fabricated to address this issue,which demonstrates an amplified humidity-sensing signal performance.By regulation of monomers and functional groups,these COF films can be pre-engineered to achieve high response,wide detection range,fast response,and recovery time.Under the condition of relative humidity ranging from 13 to 98%,the COFTAPB-DHTA film-based humidity sensor exhibits outstanding humidity sensing perfor-mance with an expanded response value of 390 times.Furthermore,the response values of the COF film-based sensor are highly linear to the relative humidity in the range below 60%,reflecting a quantitative sensing mechanism at the molecular level.Based on the dual-site adsorption of the(-C=N-)and(C-N)stretching vibrations,the revers-ible tautomerism induced by hydrogen bonding with water molecules is demonstrated to be the main intrinsic mechanism for this effective humidity detection.In addition,the synthesized COF films can be further exploited to effectively detect human nasal and oral breathing as well as fabric permeability,which will inspire novel designs for effective humidity-detection devices.