Sensitive detection of Staphylococcus aureus enterotoxin B(SEB)is of importance for preventing food poisoning from threatening human health.In this work,an electrochemical and colorimetric dual-signal detection assay ...Sensitive detection of Staphylococcus aureus enterotoxin B(SEB)is of importance for preventing food poisoning from threatening human health.In this work,an electrochemical and colorimetric dual-signal detection assay of SEB was developed.The probe(Ab2/AuPt@Fe-N-C)was bound to SEB captured by Ab1,where the Ab2/AuPt@Fe-N-C triggered methylene blue degradation and resulted in the decrease of electrochemical signal.Furthermore,the probe catalyzed the oxidation of 3,3’,5,5’-tetramethyl biphenyl to generate a colorimetric absorbance at 652 nm.Once the target was captured and formed a sandwich-like complex,the color changed from colorless to blue.SEB detection by colorimetric and electrochemical methods showed a linear relationship in the concentration ranges of 0.0002-10.0000 and 0.0005-10.0000 ng/mL,with limits of detection of 0.0667 and 0.1670 pg/mL,respectively.The dual-signal biosensor was successfully used to detect SEB in milk and water samples,which has great potential in toxin detection in food and the environment.展开更多
[Objective] The aim is to develop the piezoelectric immunosensor to detect H9-subtype avian influenza virus(AIV).[Method] The immunosensor chip was constructed by self-assembling mercaptopmpionic acid(MPA) to be m...[Objective] The aim is to develop the piezoelectric immunosensor to detect H9-subtype avian influenza virus(AIV).[Method] The immunosensor chip was constructed by self-assembling mercaptopmpionic acid(MPA) to be monolayer on the silver-coated electrode of quartz crystal and coupling the monoclonal antibody to H9 subtype AIV with N-ethy-N'-(3-dimethyl aminopropyl)carbodiimide hydrochloride(EDC) and N-hydroxysuccinimide(NHS).The immunosensor to detect H9 subtype AIV was established.[Result] The results showed that the immunosensor displayed better specificity to H9 AIV and had no response to H5AIV and NDV when it was used for detection.The sensitivity test indicated the detection sensitivity for the H9 subtype AIV could reach 20-100 EID50.[Conclusion] The research provided a foundation for further research on the immunosensor for detecting AIV and it could be a new approach to detect other related viruses.展开更多
An impedance immunosensor based on O-phenylenediamine modified gold electrode for the determination of phytohormone abscisic acid(ABA) was proposed.The operating pH,absorption time,absorption temperature and concentra...An impedance immunosensor based on O-phenylenediamine modified gold electrode for the determination of phytohormone abscisic acid(ABA) was proposed.The operating pH,absorption time,absorption temperature and concentration of anti-ABA antibody were investigated to optimize the analytical performance.The calibration curve for the determination of ABA was obtained from this impedance immunosensor under optimal conditions.The results showed that the detection limit at about 1 ng/mL in the range of 10-5000 ng/mL...展开更多
A novel multilayer film based on Au nanoparticles(AuNPs) and polyaniline/carboxylated multiwall carbon nanotubes-chitosan nanocomposite(PANI/MWCNTs/CS) was exploited to fabricate a highly sensitive immunosensor for de...A novel multilayer film based on Au nanoparticles(AuNPs) and polyaniline/carboxylated multiwall carbon nanotubes-chitosan nanocomposite(PANI/MWCNTs/CS) was exploited to fabricate a highly sensitive immunosensor for detecting chlorpyrifos. PANI-coated MWCNTs were prepared by in situ chemical polymerization and carboxylated MWCNTs played an important role in obtaining the thin and uniform coating of PANI resulting in the improved immunosensor response. Au NPs were used as a linker to immobilize chlorpyrifos antibody. The performance of the immunosensor was characterized by means of cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS) and scanning electron microscopy(SEM), respectively. All variables involved in the preparation process and analytical performance of the immunosensor were optimized.Under optimal conditions(antibody concentration: 5 μg/mL, working buffer pH: 6.5, incubation time: 40 min,incubation temperature: 25℃), the immunosensor exhibited a wide linear range from 0.1 to 40× 10^(-6)mg/mL and from 40 × 10^(-6)mg/mL to 500 × 10^(-6)mg/mL, and with a detection limit of 0.06 × 10^(-6)mg/mL, which provided a valuable tool for the chlorpyrifos detection in real samples.展开更多
A micro amperometric immunosensor with the sensitive area of only 1mm^2 was fabricated on silicon using the technique of Micro-Electro-Mechanical Systems (MEMS).A double exposure of SU-8 photoresist process was develo...A micro amperometric immunosensor with the sensitive area of only 1mm^2 was fabricated on silicon using the technique of Micro-Electro-Mechanical Systems (MEMS).A double exposure of SU-8 photoresist process was developed to create both the sensitive pool and reaction pool.Antibody was immobilized via cross-linking with glutaraldehyde on the sensitive area of the electrode surface,which was electropolymerized with polypyrrole previously.The immunosensor was characterized by detection of human immunoglobulin G (HIgG).The immunosensor displayed a good linear response to HIgG concentrations between 5ng/ml and 255ng/ml and demonstrated a fast response time of 3 minutes.展开更多
A novel immunosensor based on surface plasmon resonance(SPR) has been developed for the recognition of antigen. The sensor was designed on the basis of the fixed angle of incidence and measuring the reflected intens...A novel immunosensor based on surface plasmon resonance(SPR) has been developed for the recognition of antigen. The sensor was designed on the basis of the fixed angle of incidence and measuring the reflected intensities in a wavelength range of 430--750 nm in real-time. An ultra-bright white light-emitting diode(LED) was used as the light source. Molecular self-assembling in solution was used to form the sensing membrane on gold substrate. It has been seen that the sensitivity of the SPR sensor with 3-mercaptopropionic acid(MPA)/protein A(SPA) sensing membrane is considerably higher than that with MPA or SPA modified sensing membrane. The kinetic processes on the sensing membrane were studied. The human B factor(Bf), an activator of complement 3(C3), was recognized among the other antigens. This sensor can also be used for other antigen/antibody or adaptor/receptor recognition. Under optimized experimental conditions, the sensor has good selectivity, repeatability, and reversibility.展开更多
Convenient,rapid,and accurate detection of cardiac troponin I(cTnI)is crucial in early diagnosis of acute myocardial infarction(AMI).A paper-based electrochemical immunosensor is a promising choice in this field,becau...Convenient,rapid,and accurate detection of cardiac troponin I(cTnI)is crucial in early diagnosis of acute myocardial infarction(AMI).A paper-based electrochemical immunosensor is a promising choice in this field,because of the flexibility,porosity,and cost-efficacy of the paper.However,paper is poor in electronic conductivity and surface functionality.Herein,we report a paper-based electrochemical immunosensor for the label-free detection of cTnI with the working electrode modified by MXene(Ti_(3)C_(2))nanosheets.In order to immobilize the bio-receptor(anti-cTnI)on the MXene-modified working electrode,the MXene nanosheets were functionalized by aminosilane,and the functionalized MXene was immobilized onto the surface of the working electrode through Nafion.The large surface area of the MXene nanosheets facilitates the immobilization of antibodies,and the excellent conductivity facilitates the electron transfer between the electrochemical species and the underlying electrode surface.As a result,the paper-based immunosensor could detect cTnI within a wide range of 5-100 ng/mL with a detection limit of 0.58 ng/mL.The immunosensor also shows outstanding selectivity and good repeatability.Our MXene-modified paper-based electrochemical immunosensor enables fast and sensitive detection of cTnI,which may be used in real-time and cost-efficient monitoring of AMI diseases in clinics.展开更多
基金This work was financially supported by Major Science and Technology Project of Yunnan Province(202302AE090022)Key Research and Development Program of Yunnan(202203AC100010)+4 种基金the National Natural Science Foundation of China(32160597,32160236,32371463)National Key Research and Development Program of China(2022YFC2601604)Cardiovascular Ultrasound Innovation Team of Yunnan Province(202305AS350021)Spring City Plan:the High-level Talent Promotion and Training Project of Kunming(2022SCP001)the second phase of“Double-First Class”Program Construction of Yunnan University.
文摘Sensitive detection of Staphylococcus aureus enterotoxin B(SEB)is of importance for preventing food poisoning from threatening human health.In this work,an electrochemical and colorimetric dual-signal detection assay of SEB was developed.The probe(Ab2/AuPt@Fe-N-C)was bound to SEB captured by Ab1,where the Ab2/AuPt@Fe-N-C triggered methylene blue degradation and resulted in the decrease of electrochemical signal.Furthermore,the probe catalyzed the oxidation of 3,3’,5,5’-tetramethyl biphenyl to generate a colorimetric absorbance at 652 nm.Once the target was captured and formed a sandwich-like complex,the color changed from colorless to blue.SEB detection by colorimetric and electrochemical methods showed a linear relationship in the concentration ranges of 0.0002-10.0000 and 0.0005-10.0000 ng/mL,with limits of detection of 0.0667 and 0.1670 pg/mL,respectively.The dual-signal biosensor was successfully used to detect SEB in milk and water samples,which has great potential in toxin detection in food and the environment.
基金Supported by the Supporting Program of the"Eleventh Five-year Plan"for Sci&Tech Research of China(2006BAK20A29)Strategical Project for Science and Technology of Guangdong Province(2004A2090102)~~
文摘[Objective] The aim is to develop the piezoelectric immunosensor to detect H9-subtype avian influenza virus(AIV).[Method] The immunosensor chip was constructed by self-assembling mercaptopmpionic acid(MPA) to be monolayer on the silver-coated electrode of quartz crystal and coupling the monoclonal antibody to H9 subtype AIV with N-ethy-N'-(3-dimethyl aminopropyl)carbodiimide hydrochloride(EDC) and N-hydroxysuccinimide(NHS).The immunosensor to detect H9 subtype AIV was established.[Result] The results showed that the immunosensor displayed better specificity to H9 AIV and had no response to H5AIV and NDV when it was used for detection.The sensitivity test indicated the detection sensitivity for the H9 subtype AIV could reach 20-100 EID50.[Conclusion] The research provided a foundation for further research on the immunosensor for detecting AIV and it could be a new approach to detect other related viruses.
基金supported by the National Natural Science Foundation of China(No.90817101,30670190 and 3060049)
文摘An impedance immunosensor based on O-phenylenediamine modified gold electrode for the determination of phytohormone abscisic acid(ABA) was proposed.The operating pH,absorption time,absorption temperature and concentration of anti-ABA antibody were investigated to optimize the analytical performance.The calibration curve for the determination of ABA was obtained from this impedance immunosensor under optimal conditions.The results showed that the detection limit at about 1 ng/mL in the range of 10-5000 ng/mL...
基金supported by the National Natural Science Foundation of China (No. 30972055, 31101286)Agricultural Science and Technology Achievements Transformation Fund Projects of the Ministry of Science and Technology of China (No. 2011GB2C60020)Shandong Provincial Natural Science Foundation, China (No. Q2008D03)
文摘A novel multilayer film based on Au nanoparticles(AuNPs) and polyaniline/carboxylated multiwall carbon nanotubes-chitosan nanocomposite(PANI/MWCNTs/CS) was exploited to fabricate a highly sensitive immunosensor for detecting chlorpyrifos. PANI-coated MWCNTs were prepared by in situ chemical polymerization and carboxylated MWCNTs played an important role in obtaining the thin and uniform coating of PANI resulting in the improved immunosensor response. Au NPs were used as a linker to immobilize chlorpyrifos antibody. The performance of the immunosensor was characterized by means of cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS) and scanning electron microscopy(SEM), respectively. All variables involved in the preparation process and analytical performance of the immunosensor were optimized.Under optimal conditions(antibody concentration: 5 μg/mL, working buffer pH: 6.5, incubation time: 40 min,incubation temperature: 25℃), the immunosensor exhibited a wide linear range from 0.1 to 40× 10^(-6)mg/mL and from 40 × 10^(-6)mg/mL to 500 × 10^(-6)mg/mL, and with a detection limit of 0.06 × 10^(-6)mg/mL, which provided a valuable tool for the chlorpyrifos detection in real samples.
基金The authors greatly acknowledge the financial support from the National Natural Science Foundation of China (Grant No. 90307014)
文摘A micro amperometric immunosensor with the sensitive area of only 1mm^2 was fabricated on silicon using the technique of Micro-Electro-Mechanical Systems (MEMS).A double exposure of SU-8 photoresist process was developed to create both the sensitive pool and reaction pool.Antibody was immobilized via cross-linking with glutaraldehyde on the sensitive area of the electrode surface,which was electropolymerized with polypyrrole previously.The immunosensor was characterized by detection of human immunoglobulin G (HIgG).The immunosensor displayed a good linear response to HIgG concentrations between 5ng/ml and 255ng/ml and demonstrated a fast response time of 3 minutes.
基金National Key Technologies Research & Development Program of China(No.2006BAK03A09)National Basic Research Program of China(No.2007CB714503)Science and Technology Development Program of Jilin Province, China (No.20060706)
文摘A novel immunosensor based on surface plasmon resonance(SPR) has been developed for the recognition of antigen. The sensor was designed on the basis of the fixed angle of incidence and measuring the reflected intensities in a wavelength range of 430--750 nm in real-time. An ultra-bright white light-emitting diode(LED) was used as the light source. Molecular self-assembling in solution was used to form the sensing membrane on gold substrate. It has been seen that the sensitivity of the SPR sensor with 3-mercaptopropionic acid(MPA)/protein A(SPA) sensing membrane is considerably higher than that with MPA or SPA modified sensing membrane. The kinetic processes on the sensing membrane were studied. The human B factor(Bf), an activator of complement 3(C3), was recognized among the other antigens. This sensor can also be used for other antigen/antibody or adaptor/receptor recognition. Under optimized experimental conditions, the sensor has good selectivity, repeatability, and reversibility.
基金financially supported by the National Key R&D Program of China(2017YFA0204700)the Joint Research Funds of Department of Science&Technology of Shaanxi Province and Northwestern Polytechnical University(2020GXLH-Z-021)+1 种基金the China-Sweden Joint Mobility Project(51811530018)the Fundamental Research Funds for the Central Universities.
文摘Convenient,rapid,and accurate detection of cardiac troponin I(cTnI)is crucial in early diagnosis of acute myocardial infarction(AMI).A paper-based electrochemical immunosensor is a promising choice in this field,because of the flexibility,porosity,and cost-efficacy of the paper.However,paper is poor in electronic conductivity and surface functionality.Herein,we report a paper-based electrochemical immunosensor for the label-free detection of cTnI with the working electrode modified by MXene(Ti_(3)C_(2))nanosheets.In order to immobilize the bio-receptor(anti-cTnI)on the MXene-modified working electrode,the MXene nanosheets were functionalized by aminosilane,and the functionalized MXene was immobilized onto the surface of the working electrode through Nafion.The large surface area of the MXene nanosheets facilitates the immobilization of antibodies,and the excellent conductivity facilitates the electron transfer between the electrochemical species and the underlying electrode surface.As a result,the paper-based immunosensor could detect cTnI within a wide range of 5-100 ng/mL with a detection limit of 0.58 ng/mL.The immunosensor also shows outstanding selectivity and good repeatability.Our MXene-modified paper-based electrochemical immunosensor enables fast and sensitive detection of cTnI,which may be used in real-time and cost-efficient monitoring of AMI diseases in clinics.