期刊文献+
共找到33,360篇文章
< 1 2 250 >
每页显示 20 50 100
Non-crossing Quantile Regression Neural Network as a Calibration Tool for Ensemble Weather Forecasts 被引量:1
1
作者 Mengmeng SONG Dazhi YANG +7 位作者 Sebastian LERCH Xiang'ao XIA Gokhan Mert YAGLI Jamie M.BRIGHT Yanbo SHEN Bai LIU Xingli LIU Martin Janos MAYER 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第7期1417-1437,共21页
Despite the maturity of ensemble numerical weather prediction(NWP),the resulting forecasts are still,more often than not,under-dispersed.As such,forecast calibration tools have become popular.Among those tools,quantil... Despite the maturity of ensemble numerical weather prediction(NWP),the resulting forecasts are still,more often than not,under-dispersed.As such,forecast calibration tools have become popular.Among those tools,quantile regression(QR)is highly competitive in terms of both flexibility and predictive performance.Nevertheless,a long-standing problem of QR is quantile crossing,which greatly limits the interpretability of QR-calibrated forecasts.On this point,this study proposes a non-crossing quantile regression neural network(NCQRNN),for calibrating ensemble NWP forecasts into a set of reliable quantile forecasts without crossing.The overarching design principle of NCQRNN is to add on top of the conventional QRNN structure another hidden layer,which imposes a non-decreasing mapping between the combined output from nodes of the last hidden layer to the nodes of the output layer,through a triangular weight matrix with positive entries.The empirical part of the work considers a solar irradiance case study,in which four years of ensemble irradiance forecasts at seven locations,issued by the European Centre for Medium-Range Weather Forecasts,are calibrated via NCQRNN,as well as via an eclectic mix of benchmarking models,ranging from the naïve climatology to the state-of-the-art deep-learning and other non-crossing models.Formal and stringent forecast verification suggests that the forecasts post-processed via NCQRNN attain the maximum sharpness subject to calibration,amongst all competitors.Furthermore,the proposed conception to resolve quantile crossing is remarkably simple yet general,and thus has broad applicability as it can be integrated with many shallow-and deep-learning-based neural networks. 展开更多
关键词 ensemble weather forecasting forecast calibration non-crossing quantile regression neural network CORP reliability diagram POST-PROCESSING
下载PDF
A real-time calibration method based on time-to-digital converter for accelerator timing system
2
作者 Qi-Hao Duan Liang Ge +2 位作者 Yan-Hao Jia Jie-Yu Zhu Wei Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期127-140,共14页
The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed ov... The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed over a certain range of 2 km,involving over a hundred devices.The white rabbit,a technology-enhancing Gigabit Ethernet,has shown the capability of scheduling distributed timing devices but still faces the challenge of obtaining real-time synchronization calibration param-eters with high precision.This study presents a calibration system based on a time-to-digital converter implemented on an ARM-based System-on-Chip(SoC).The system consists of four multi-sample delay lines,a bubble-proof encoder,an edge controller for managing data from different channels,and a highly effective calibration module that benefits from the SoC architecture.The performance was evaluated with an average RMS precision of 5.51 ps by measuring the time intervals from 0 to 24,000 ps with 120,000 data for every test.The design presented in this study refines the calibration precision of the HIAF timing system.This eliminates the errors caused by manual calibration without efficiency loss and provides data support for fault diagnosis.It can also be easily tailored or ported to other devices for specific applications and provides more space for developing timing systems for particle accelerators,such as white rabbits on HIAF. 展开更多
关键词 HIAF White rabbit calibration system Time-to-digital converter(TDC)
下载PDF
Wavelength calibration and spectral analysis of vacuum ultraviolet spectroscopy in EAST
3
作者 计华健 张洪明 +6 位作者 吕波 Cheonho BAE 何梁 林子超 尹相辉 沈永才 戴舒宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期37-43,共7页
A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength c... A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak. 展开更多
关键词 vacuum ultraviolet spectroscopy wavelength calibration impurity spectra
下载PDF
A Weakly-Supervised Crowd Density Estimation Method Based on Two-Stage Linear Feature Calibration
4
作者 Yong-Chao Li Rui-Sheng Jia +1 位作者 Ying-Xiang Hu Hong-Mei Sun 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第4期965-981,共17页
In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd dat... In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd datasets,and propose a crowd density estimation method based on weakly-supervised learning,in the absence of crowd position supervision information,which directly reduces the number of crowds by using the number of pedestrians in the image as the supervised information.For this purpose,we design a new training method,which exploits the correlation between global and local image features by incremental learning to train the network.Specifically,we design a parent-child network(PC-Net)focusing on the global and local image respectively,and propose a linear feature calibration structure to train the PC-Net simultaneously,and the child network learns feature transfer factors and feature bias weights,and uses the transfer factors and bias weights to linearly feature calibrate the features extracted from the Parent network,to improve the convergence of the network by using local features hidden in the crowd images.In addition,we use the pyramid vision transformer as the backbone of the PC-Net to extract crowd features at different levels,and design a global-local feature loss function(L2).We combine it with a crowd counting loss(LC)to enhance the sensitivity of the network to crowd features during the training process,which effectively improves the accuracy of crowd density estimation.The experimental results show that the PC-Net significantly reduces the gap between fullysupervised and weakly-supervised crowd density estimation,and outperforms the comparison methods on five datasets of Shanghai Tech Part A,ShanghaiTech Part B,UCF_CC_50,UCF_QNRF and JHU-CROWD++. 展开更多
关键词 Crowd density estimation linear feature calibration vision transformer weakly-supervision learning
下载PDF
A new calibration method for radon detector in seismic systems
5
作者 Hongwei Ren Yaowei Liu 《Earthquake Science》 2024年第5期445-458,共14页
Radon observation is an important measurement item of seismic precursor network observation.The radon detector calibration is a key technical link for ensuring radon observation accuracy.At present,the radon detector ... Radon observation is an important measurement item of seismic precursor network observation.The radon detector calibration is a key technical link for ensuring radon observation accuracy.At present,the radon detector calibration in seismic systems in China is faced with a series of bottleneck problems,such as aging and scrap,acquisition difficulties,high supervision costs,and transportation limitations of radon sources.As a result,a large number of radon detectors cannot be accurately calibrated regularly,seriously affecting the accuracy and reliability of radon observation data in China.To solve this problem,a new calibration method for radon detectors was established.The advantage of this method is that the dangerous radioactive substance,i.e.,the radon source,can be avoided,but only“standard instruments”and water samples with certain dissolved radon concentrations can be used to realize radon detector calibration.This method avoids the risk of radioactive leakage and solves the current widespread difficulties and bottleneck of radon detector calibration in seismic systems in China.The comparison experiment with the traditional calibration method shows that the error of the calibration coefficient obtained by the new method is less than 5%compared with that by the traditional method,which meets the requirements of seismic observation systems,confirming the reliability of the new method.This new method can completely replace the traditional calibration method of using a radon source in seismic systems. 展开更多
关键词 radon detector calibration “standard instrument” scintillation chamber radon source
下载PDF
Kinematic calibration under the expectation maximization framework for exoskeletal inertial motion capture system
6
作者 QIN Weiwei GUO Wenxin +2 位作者 HU Chen LIU Gang SONG Tainian 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期769-779,共11页
This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters ... This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters are calibrated by the traditional calibration method at first. Then, in order to calibrate the parameters affected by the random colored noise, the expectation maximization (EM) algorithm is introduced. Through the use of geometric parameters calibrated by the traditional calibration method, the iterations under the EM framework are decreased and the efficiency of the proposed method on embedded system is improved. The performance of the proposed kinematic calibration method is compared to the traditional calibration method. Furthermore, the feasibility of the proposed method is verified on the EI-MoCap system. The simulation and experiment demonstrate that the motion capture precision is significantly improved by 16.79%and 7.16%respectively in comparison to the traditional calibration method. 展开更多
关键词 human motion capture kinematic calibration EXOSKELETON gyroscopic drift expectation maximization(EM)
下载PDF
Calibration of CO and CO2 Monitors Used in Periodic Inspection of Vehicles at Fixed Stations for Environmental Control
7
作者 Adel Bassuoni Shehata Abdulrahman Rashed Al Askar +2 位作者 Najjy Hamad Al Yami Abdullah Suleiman Al Owaysi Sultan K. Alharbi 《Green and Sustainable Chemistry》 2024年第2期29-41,共13页
Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuri... Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment. 展开更多
关键词 MONITORS Periodic Inspection CO/CO2 calibration LINEARITY Precision Accuracy
下载PDF
Parameter calibration of the tensile-shear interactive damage constitutive model for sandstone failure
8
作者 Yun Shu Zheming Zhu +4 位作者 Meng Wang Weiting Gao Fei Wang Duanying Wan Yuntao Wang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第4期1153-1174,共22页
The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The bas... The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The basic parameters of sandstone are determined through a series of static and dynamic tests,including uniaxial compression,Brazilian disc,triaxial compression under varying confining pressures,hydrostatic compression,and dynamic compression and tensile tests with a split Hopkinson pressure bar.Based on the sandstone test results from this study and previous research,a step-by-step procedure for parameter calibration is outlined,which accounts for the categories of the strength surface,equation of state(EOS),strain rate effect,and damage.The calibrated parameters are verified through numerical tests that correspond to the experimental loading conditions.Consistency between numerical results and experimental data indicates the precision and reliability of the calibrated parameters.The methodology presented in this study is scientifically sound,straightforward,and essential for improving the TSID model.Furthermore,it has the potential to contribute to other rock constitutive models,particularly new user-defined models. 展开更多
关键词 Damage constitutive model Parameter calibration Rock modeling SANDSTONE Dynamic impact load Tensile-shear interactive damage(TSID)model
下载PDF
Global Calibration Method for Monocular Multi-View System Using Rotational Dual-Target
9
作者 Kun He Hongwei He 《Open Journal of Applied Sciences》 2024年第5期1192-1203,共12页
To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calib... To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calibration method is proposed for the geometric properties of rotational correlation motion and the absolute orientation of the field of view without over lap. Firstly, a dual-camera system is constructed for photographing and collecting the rotating image sequence of two flat targets rigidly connected by a long rod at different positions, and based on the known parameters, such as, target feature image, world coordinates, camera internal parameters and so on, then the global PnP optimization method is used to solve the rotation axis and the reference point at different positions;Then, the absolute orientation matrix is constructed based on the parameters of rotation axis, reference point and connecting rod length obtained by this method. In the end, the singular value decomposition method is used to find the optimal rotation matrix, and then get the translation matrix. It’s shown based on simulation and actual tests that in comparison with the existing methods, the maximum attitude and pose errors is 0.0083˚ and 0.3657 mm, respectively, which improves the accuracy by 27.8% and 24.4%, respectively. The calibration device in this paper is simple, and there are no parallel, vertical and coplanar requirements between multiple rotating positions. At the same time, in view of the calibration accuracy, the accuracy requirements of most application scenarios can be met. 展开更多
关键词 Machine Vision Accurate Demarcating Global calibration Absolute Orientation
下载PDF
Nose-to-nose校准技术的理论分析 被引量:10
10
作者 朱江淼 刘明亮 卢峰 《电子学报》 EI CAS CSCD 北大核心 2005年第3期480-483,共4页
Nose- to- nose校准技术的理论基础是 :kick -out脉冲正比于取样示波器系统的冲激响应 .Janverspecht博士和美国国家标准技术研究院 (NIST)用S参数法对此进行了详尽的分析 .本文从电路理论分析入手 ,对kick- out脉冲产生的机理重新进行... Nose- to- nose校准技术的理论基础是 :kick -out脉冲正比于取样示波器系统的冲激响应 .Janverspecht博士和美国国家标准技术研究院 (NIST)用S参数法对此进行了详尽的分析 .本文从电路理论分析入手 ,对kick- out脉冲产生的机理重新进行了分析 ,得出了十分有用的数学表达式和结论 :kick out脉冲不仅与电路参数有关 ,而且与选通脉冲有关 .这一结论并被计算机的仿真所证实 ,这用以前的理论是无法解释的 . 展开更多
关键词 校准 nose-to-nose kick-out脉冲 宽带取样示波器
下载PDF
宽带取样示波器Nose-to-Nose校正理论的新进展 被引量:9
11
作者 林茂六 赵华 《电子学报》 EI CAS CSCD 北大核心 2001年第3期409-411,共3页
本文根据电路、信号与系统理论并结合实际校测工作对一种适于高速 /宽带取样示波器性能校正的新方法———Nose to Nose (NTN)法的理论基础作了研究 ,分析了该方法中的重要信号kick out脉冲 ,推导了其数学表达式 ,提出了“kick out脉冲... 本文根据电路、信号与系统理论并结合实际校测工作对一种适于高速 /宽带取样示波器性能校正的新方法———Nose to Nose (NTN)法的理论基础作了研究 ,分析了该方法中的重要信号kick out脉冲 ,推导了其数学表达式 ,提出了“kick out脉冲与示波器取样系统的阶跃响应成比例”的新观点 。 展开更多
关键词 nose-to-nose 取样示波器 时域测量 校正 宽带
下载PDF
用于宽带取样示波器的Nose-to-nose校准技术 被引量:6
12
作者 朱江淼 刘明亮 陈建新 《应用基础与工程科学学报》 EI CSCD 2003年第1期94-97,共4页
介绍一种宽带系统校准的新方法 ,对比几种传统的校准方法 ,这种称为nose to nose的校准方法是目前校准精度最高的一种 .这项技术所基于的一个基本事实是 :当示波器的取样电路对直流电压取样时 ,会产生一个极窄的脉冲到输入端 ,这个脉冲... 介绍一种宽带系统校准的新方法 ,对比几种传统的校准方法 ,这种称为nose to nose的校准方法是目前校准精度最高的一种 .这项技术所基于的一个基本事实是 :当示波器的取样电路对直流电压取样时 ,会产生一个极窄的脉冲到输入端 ,这个脉冲正比于系统的冲激响应 ,称为kick out脉冲 ,这样将两台示波器的输入端对接就在第二台示波器上得到了含有两台示波器冲激响应的卷积输出 ,应用反卷积算法可以得到这两台示波器的冲激响应函数 . 展开更多
关键词 宽带取样示波器 nose-to-nose校准方法 冲激响应函数 反卷积算法 宽带系统校准 取样电路
下载PDF
基于Nose-to-Nose校准法的取样示波器冲激响应的一种算法 被引量:2
13
作者 赵华 林茂六 《电子学报》 EI CAS CSCD 北大核心 2003年第3期365-367,共3页
本文根据时变电路概念和信号与电路系统理论 ,利用Nose to Nose(NTN)校正法 ,对取样示波器的双二极管平衡型取样电路建立了时变线性电路模型 ,导出了kick out脉冲和取样系统冲激响应的时域表达式 ,证明了该脉冲是NTN校正中的零输入响应... 本文根据时变电路概念和信号与电路系统理论 ,利用Nose to Nose(NTN)校正法 ,对取样示波器的双二极管平衡型取样电路建立了时变线性电路模型 ,导出了kick out脉冲和取样系统冲激响应的时域表达式 ,证明了该脉冲是NTN校正中的零输入响应而非冲激响应 ,提出了从kick out脉冲中提取时间常数从而确定取样器冲激响应的新的数据处理方法与公式 ,有效地解决了NTN校正中取样管结电容变化对校正精度的影响问题 . 展开更多
关键词 nose-to-nose校正 取样 时变电路冲激响应 示波器 kick-out脉冲
下载PDF
取样示波器nose-to-nose校准技术中kick-out脉冲的研究 被引量:1
14
作者 朱江淼 刘明亮 高昀 《中国计量学院学报》 2003年第3期185-188,共4页
 研究了nose-to-nose校准技术中关键信号kick-out脉冲产生的机理以及影响因素,并通过将两台Agilent86100系列的50GHz的取样示波器对接,获得了kick-out脉冲的响应波形.
关键词 取样示波器 nose-to-nose校准技术 kick-out脉冲 产生机理 响应波形 阶跃响应
下载PDF
GYRO BIAS ON-ORBIT CALIBRATION FOR MICRO SATELLITES 被引量:1
15
作者 郁丰 刘建业 熊智 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2007年第4期300-304,共5页
According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements r... According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements restricted by satellite attitude dynamics and estimates the gyro bias generated when the gyro is electrified. Observability of the calibration model is analyzed and applicable conditions of the technology are derived. Simulation results indicate that the calibration algorithm is accurate and robust at gyro sampling rate, and its convergence speed is fast. Within the given attitude dynamics model error, the convergence time is less than 100 s and the convergence accuracy is about 1.0 (°)/h. Calibration performance can meet requirements of spacecraft operations. 展开更多
关键词 on-orbit calibration gyro bias Kalman filter micro satellite
下载PDF
基于MATLAB中calibration toolbox的相机标定应用研究 被引量:10
16
作者 张曦 黄亮 +1 位作者 徐洋 郭冬霄 《微型机与应用》 2011年第14期31-33,共3页
相机标定的目的是确定相机的几何和光学参数以及相机相对于世界坐标系的方位。cal-ibration toolbox作为一个标定工具,容纳了如Tsai、Faugeras等多种经典的标定方法,从自主标定的使用方面详细介绍了calibration toolbox的使用方法。
关键词 相机标定 MATLAB 标定工具箱
下载PDF
Nose-to-Nose校准技术的仿真研究 被引量:1
17
作者 朱苏磊 《测试技术学报》 EI 2005年第4期394-397,共4页
N ose-to-nose校准技术可以对任意带宽的取样示波器进行自校准.早期的研究工作集中在对关键信号k ick-ou t脉冲的仿真.本文从不同的角度对微波二极管取样头电路进行了全面的仿真,得到了结论:k ick-ou t脉冲是由于在取样电路的不平衡时... N ose-to-nose校准技术可以对任意带宽的取样示波器进行自校准.早期的研究工作集中在对关键信号k ick-ou t脉冲的仿真.本文从不同的角度对微波二极管取样头电路进行了全面的仿真,得到了结论:k ick-ou t脉冲是由于在取样电路的不平衡时选通脉冲的泄漏造成的.并对NTN校准技术从仿真实验到物理实验做了介绍. 展开更多
关键词 取样示波器 校准 kick—out脉冲 脉冲响应 nose-to-nose
下载PDF
Sub-pixel extraction of laser stripeand itsapplication in laser plane calibration 被引量:2
18
作者 陈平 张志胜 +1 位作者 戴敏 陈恺 《Journal of Southeast University(English Edition)》 EI CAS 2015年第1期107-112,共6页
For calibrating the laser plane to implement 3D shape measurement, an algorithm for extracting the laser stripe with sub-pixel accuracy is proposed. The proposed algorithm mainly consists of two stages: two-side edge... For calibrating the laser plane to implement 3D shape measurement, an algorithm for extracting the laser stripe with sub-pixel accuracy is proposed. The proposed algorithm mainly consists of two stages: two-side edge detection and center line extraction. First, the two-side edge of laser stripe is detected using the principal component angle-based progressive probabilistic Hough transform and its width is calculated through the distance between these two edges. Secondly, the center line of laser strip is extracted with 2D Taylor expansion at a sub-pixel level and the laser plane is calibrated with the 3D reconstructed coordinates from the extracted 2D sub-pixel ones. Experimental results demonstrate that the proposed method can not only extract the laser stripe at a high speed, nearly average 78 ms/frame, but also calibrate the coplanar laser stripes at a low error, limited to 0.3 mm. The proposed algorithm can satisfy the system requirement of two-side edge detection and center line extraction, and rapid speed, high precision, as well as strong anti-jamming. 展开更多
关键词 sub-pixel extraction center line extraction laser plane calibration progressive probabilistic Hough transform (PPHT) principal component (PC) angle 2D Taylor expan- sion
下载PDF
Calibration Scheme Under Spherical Coordinates for Magnetic Tracker Used in VR System
19
作者 徐彤 刘莉萍 +1 位作者 刘越 王涌天 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期256-258,共3页
A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, ... A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, spe cified in spherical coordinates, is generated first, which is then used to calibrate the tracking results by a two dimensional interpolation. The scheme can effectively correct the static errors in the magnetic tracking system. The employment of spherical coordinates significantly reduces the calculation complexity in calibration. 展开更多
关键词 calibration magnetic tracking virtual reality
下载PDF
基于Internet的数字示波器e-Calibration技术研究 被引量:1
20
作者 王勇 施文康 《计算机测量与控制》 CSCD 2004年第3期296-297,300,共3页
目前,国际测试计量领域诞生了一种新的校准技术——远程校准技术(e-Calibration).远程校准技术是一个全新的概念,它将日益发展的互联网技术与传统的校准方式结合起来,是测试计量领域发展的新趋势。以DSO(数字式存储示波器)为例,提出了... 目前,国际测试计量领域诞生了一种新的校准技术——远程校准技术(e-Calibration).远程校准技术是一个全新的概念,它将日益发展的互联网技术与传统的校准方式结合起来,是测试计量领域发展的新趋势。以DSO(数字式存储示波器)为例,提出了一种基于Internet的e-Calibration可行性方案,其对e-Calibration的实际应用有一定的参考价值。 展开更多
关键词 INTERNET 数字示波器 e-calibration 远程校准 互联网
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部