Variable temperature X ray diffraction(XRD) was used to investigate the crystalline transition of Nylon 1012. The results show that Nylon 1012 undergoes a crystalline relaxation between the glass transition temperatur...Variable temperature X ray diffraction(XRD) was used to investigate the crystalline transition of Nylon 1012. The results show that Nylon 1012 undergoes a crystalline relaxation between the glass transition temperature and the melting point. We thus demonstrate, for the first time, the presence of the Brill transition in Nylon 1012, a phenomena that has been extensively studied in Nylon 66. It is found that the Brill transition temperature is about 120 ℃ and we have also showed that the Brill transition of Nylon 1012 is reversible when cooling the high temperature pseudohexagonal structure to room temperature. [WT5HZ]展开更多
文摘Variable temperature X ray diffraction(XRD) was used to investigate the crystalline transition of Nylon 1012. The results show that Nylon 1012 undergoes a crystalline relaxation between the glass transition temperature and the melting point. We thus demonstrate, for the first time, the presence of the Brill transition in Nylon 1012, a phenomena that has been extensively studied in Nylon 66. It is found that the Brill transition temperature is about 120 ℃ and we have also showed that the Brill transition of Nylon 1012 is reversible when cooling the high temperature pseudohexagonal structure to room temperature. [WT5HZ]