Of the 700,000 people in the United States who experience a new or recurrent stroke each year,more than 500,000 survive(American Stroke Association,2007)[1]. Occupational therapy practitioners are critical rehabilitat...Of the 700,000 people in the United States who experience a new or recurrent stroke each year,more than 500,000 survive(American Stroke Association,2007)[1]. Occupational therapy practitioners are critical rehabilitation professionals for stroke survivors.展开更多
Natural ventilation(NV)has been considered a simple and effective method of ventilation.However,the intro-duction of NV does not achieve better indoor air quality(IAQ)when the outdoor atmospheric environment is pollut...Natural ventilation(NV)has been considered a simple and effective method of ventilation.However,the intro-duction of NV does not achieve better indoor air quality(IAQ)when the outdoor atmospheric environment is polluted.Therefore,portable air cleaners(PACs)are increasing in use in recent years,but their effectiveness is highly dependent on the residents’habits.A typical residence in Xi’an,China was selected to examine the effects of the use of NV alone and the use of NV and PACs together on IAQ in the three occupant states,i.e.,unoc-cupied,sleeping and leisure.Parameters,such as temperature,relative humidity,CO_(2),and PM_(2.5)concentration were measured when changing the window opening and the position of the PAC.The results showed that in the unoccupied state,opening the inner door can promote a more uniform thermal and humid environment.In the sleeping state,the I/O ratio of the PM_(2.5)concentration was the lowest when the window opening of the bedroom was 1/2 or 3/4,with a mean value of 0.3.In the leisure state,only using NV,when the purification rate reaches 90%,the mean purification time of each window opening in the living room is 87.5 min.The mean purification time was reduced to 25 min when both NV and PAC were used.The on-site purification efficiencies were 91.0%and 94.5%,when the window opening was 1/2(i.e.,the PAC was placed in the center of the room)and 3/4(i.e.,the PAC was placed away from the outer window),respectively.展开更多
文摘Of the 700,000 people in the United States who experience a new or recurrent stroke each year,more than 500,000 survive(American Stroke Association,2007)[1]. Occupational therapy practitioners are critical rehabilitation professionals for stroke survivors.
基金This study was jointly funded by the National Key Research and Development Program of China(No.2016YFC0700500)the Opening Fund of Key Laboratory of Plateau Green Building and Ecological Community in Qinghai Province(No.KLKF-2020-005).
文摘Natural ventilation(NV)has been considered a simple and effective method of ventilation.However,the intro-duction of NV does not achieve better indoor air quality(IAQ)when the outdoor atmospheric environment is polluted.Therefore,portable air cleaners(PACs)are increasing in use in recent years,but their effectiveness is highly dependent on the residents’habits.A typical residence in Xi’an,China was selected to examine the effects of the use of NV alone and the use of NV and PACs together on IAQ in the three occupant states,i.e.,unoc-cupied,sleeping and leisure.Parameters,such as temperature,relative humidity,CO_(2),and PM_(2.5)concentration were measured when changing the window opening and the position of the PAC.The results showed that in the unoccupied state,opening the inner door can promote a more uniform thermal and humid environment.In the sleeping state,the I/O ratio of the PM_(2.5)concentration was the lowest when the window opening of the bedroom was 1/2 or 3/4,with a mean value of 0.3.In the leisure state,only using NV,when the purification rate reaches 90%,the mean purification time of each window opening in the living room is 87.5 min.The mean purification time was reduced to 25 min when both NV and PAC were used.The on-site purification efficiencies were 91.0%and 94.5%,when the window opening was 1/2(i.e.,the PAC was placed in the center of the room)and 3/4(i.e.,the PAC was placed away from the outer window),respectively.