In order to enhance the safety of the catapult launch of the carrier-based aircraft,the catapult launch multibody dynamic model is established aiming at the problem of off center catapult launch.The whole catapult pro...In order to enhance the safety of the catapult launch of the carrier-based aircraft,the catapult launch multibody dynamic model is established aiming at the problem of off center catapult launch.The whole catapult process including four stages which are buffering,tensioning,releasing and taxiing is taken into consideration and the body dynamics of the off-center catapult during each stage is analyzed.The catapult launch dynamic differences between the conditions only considering taxiing and that considering four stages are compared,and the effects of the different initial off center distances considering four stages on the attitude,landing gear load and acceleration of the carrier based aircraft during catapult launch are discussed.The results show that only considering taxiing may underestimate the dynamics of the carrier-based aircraft substantially.When taking four stages into consideration,the initial off-center distance has small influence on the aircraft dynamic characteristics during buffering and tensioning but has larger influence on that during releasing and taxiing.The increase of the off-center distance will cause the enhancement of the aircraft rolling and yawing,which may lead to the load difference between the left and right landing gears and the increase of the aircraft lateral acceleration.The establishment and simulation of the catapult launch multi body dynamic model founded on buffering,tensioning,releasing and taxiing provide reference for the carrier-based aircraft design and analysis of the catapult launch dynamics.展开更多
CBCT scanners have been widely used in angiography,radiotherapy guidance,mammography and oral maxillofacial imaging.To cut detector size,reduce manufacturing costs and radiation dose while keeping a reasonable FOV,the...CBCT scanners have been widely used in angiography,radiotherapy guidance,mammography and oral maxillofacial imaging.To cut detector size,reduce manufacturing costs and radiation dose while keeping a reasonable FOV,the flat panel detector can be placed off-center horizontally.This scanning configuration extends the FOV effectively.However,each projection is transversely truncated,bringing errors and artifacts in reconstruction.In this paper,a simple but practical method is proposed for this scanning geometry based on truncation compensation and the modified FDK algorithm.Numerical simulations with jaw phantom were conducted to evaluate the accuracy and practicability of the proposed method.A novel CBCT system for maxillofacial imaging is used for clinical test,which is equipped with an off-center small size flat panel detector.Results show that reconstruction accuracy is acceptable for clinical use,and the image quality appears sufficient for specific diagnostic requirements.It provides a novel solution for clinical CBCT system,in order to reduce radiation dose and manufacturing cost.展开更多
As a kind of special acoustic field, the helical wavefront of an acoustic vortex(AV) beam is demonstrated to have a pressure zero with phase singularity at the center in the transverse plane. The orbital angular mom...As a kind of special acoustic field, the helical wavefront of an acoustic vortex(AV) beam is demonstrated to have a pressure zero with phase singularity at the center in the transverse plane. The orbital angular momentum of AVs can be applied to the field of particle manipulation, which attracts more and more attention in acoustic researches. In this paper,by using the simplified circular array of point sources, dual coaxial AV beams are excited by the even-and odd-numbered sources with the topological charges of l_E and l_O based on the phase-coded approach, and the composite acoustic field with an on-axis center-AV and multiple off-axis sub-AVs can be generated by the superimposition of the AV beams for|l_E| ≠ |l_O|. The generation of edge phase dislocation is theoretically derived and numerically analyzed for l_E=-l_O. The numbers and the topological charges as well as the locations of the center-AV and sub-AVs are demonstrated, which are proved to be determined by the topological charges of the coaxial AV beams. The proposed approach breaks through the limit of only one on-axis AV with a single topological charge along the beam axis, and also provides the feasibility of off-axis particle trapping with multiple AVs in object manipulation.展开更多
文摘In order to enhance the safety of the catapult launch of the carrier-based aircraft,the catapult launch multibody dynamic model is established aiming at the problem of off center catapult launch.The whole catapult process including four stages which are buffering,tensioning,releasing and taxiing is taken into consideration and the body dynamics of the off-center catapult during each stage is analyzed.The catapult launch dynamic differences between the conditions only considering taxiing and that considering four stages are compared,and the effects of the different initial off center distances considering four stages on the attitude,landing gear load and acceleration of the carrier based aircraft during catapult launch are discussed.The results show that only considering taxiing may underestimate the dynamics of the carrier-based aircraft substantially.When taking four stages into consideration,the initial off-center distance has small influence on the aircraft dynamic characteristics during buffering and tensioning but has larger influence on that during releasing and taxiing.The increase of the off-center distance will cause the enhancement of the aircraft rolling and yawing,which may lead to the load difference between the left and right landing gears and the increase of the aircraft lateral acceleration.The establishment and simulation of the catapult launch multi body dynamic model founded on buffering,tensioning,releasing and taxiing provide reference for the carrier-based aircraft design and analysis of the catapult launch dynamics.
基金Supported by National Key Technology R&D Program of the Ministry of Science and Technology(No.2012BAI07B05)
文摘CBCT scanners have been widely used in angiography,radiotherapy guidance,mammography and oral maxillofacial imaging.To cut detector size,reduce manufacturing costs and radiation dose while keeping a reasonable FOV,the flat panel detector can be placed off-center horizontally.This scanning configuration extends the FOV effectively.However,each projection is transversely truncated,bringing errors and artifacts in reconstruction.In this paper,a simple but practical method is proposed for this scanning geometry based on truncation compensation and the modified FDK algorithm.Numerical simulations with jaw phantom were conducted to evaluate the accuracy and practicability of the proposed method.A novel CBCT system for maxillofacial imaging is used for clinical test,which is equipped with an off-center small size flat panel detector.Results show that reconstruction accuracy is acceptable for clinical use,and the image quality appears sufficient for specific diagnostic requirements.It provides a novel solution for clinical CBCT system,in order to reduce radiation dose and manufacturing cost.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11474166 and 11604156)the Science and Technology Cooperation Projects of People’s Republic of China–Romania(Grant No.42-23)+2 种基金the Natural Science Foundation of Jiangsu Province,China(Grant No.BK20161013)the Postdoctoral Science Foundation of China(Grant No.2016M591874)the Priority Academic Program Development of Jiangsu Higher Education Institutions,China
文摘As a kind of special acoustic field, the helical wavefront of an acoustic vortex(AV) beam is demonstrated to have a pressure zero with phase singularity at the center in the transverse plane. The orbital angular momentum of AVs can be applied to the field of particle manipulation, which attracts more and more attention in acoustic researches. In this paper,by using the simplified circular array of point sources, dual coaxial AV beams are excited by the even-and odd-numbered sources with the topological charges of l_E and l_O based on the phase-coded approach, and the composite acoustic field with an on-axis center-AV and multiple off-axis sub-AVs can be generated by the superimposition of the AV beams for|l_E| ≠ |l_O|. The generation of edge phase dislocation is theoretically derived and numerically analyzed for l_E=-l_O. The numbers and the topological charges as well as the locations of the center-AV and sub-AVs are demonstrated, which are proved to be determined by the topological charges of the coaxial AV beams. The proposed approach breaks through the limit of only one on-axis AV with a single topological charge along the beam axis, and also provides the feasibility of off-axis particle trapping with multiple AVs in object manipulation.