The widespread availability of digital multimedia data has led to a new challenge in digital forensics.Traditional source camera identification algorithms usually rely on various traces in the capturing process.Howeve...The widespread availability of digital multimedia data has led to a new challenge in digital forensics.Traditional source camera identification algorithms usually rely on various traces in the capturing process.However,these traces have become increasingly difficult to extract due to wide availability of various image processing algorithms.Convolutional Neural Networks(CNN)-based algorithms have demonstrated good discriminative capabilities for different brands and even different models of camera devices.However,their performances is not ideal in case of distinguishing between individual devices of the same model,because cameras of the same model typically use the same optical lens,image sensor,and image processing algorithms,that result in minimal overall differences.In this paper,we propose a camera forensics algorithm based on multi-scale feature fusion to address these issues.The proposed algorithm extracts different local features from feature maps of different scales and then fuses them to obtain a comprehensive feature representation.This representation is then fed into a subsequent camera fingerprint classification network.Building upon the Swin-T network,we utilize Transformer Blocks and Graph Convolutional Network(GCN)modules to fuse multi-scale features from different stages of the backbone network.Furthermore,we conduct experiments on established datasets to demonstrate the feasibility and effectiveness of the proposed approach.展开更多
An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation devi...An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps.展开更多
This paper introduces an intelligent computational approach for extracting salient objects fromimages and estimatingtheir distance information with PTZ (Pan-Tilt-Zoom) cameras. PTZ cameras have found wide applications...This paper introduces an intelligent computational approach for extracting salient objects fromimages and estimatingtheir distance information with PTZ (Pan-Tilt-Zoom) cameras. PTZ cameras have found wide applications innumerous public places, serving various purposes such as public securitymanagement, natural disastermonitoring,and crisis alarms, particularly with the rapid development of Artificial Intelligence and global infrastructuralprojects. In this paper, we combine Gauss optical principles with the PTZ camera’s capabilities of horizontal andpitch rotation, as well as optical zoom, to estimate the distance of the object.We present a novel monocular objectdistance estimation model based on the Focal Length-Target Pixel Size (FLTPS) relationship, achieving an accuracyrate of over 95% for objects within a 5 km range. The salient object extraction is achieved through a simplifiedconvolution kernel and the utilization of the object’s RGB features, which offer significantly faster computingspeeds compared to Convolutional Neural Networks (CNNs). Additionally, we introduce the dark channel beforethe fog removal algorithm, resulting in a 20 dB increase in image definition, which significantly benefits distanceestimation. Our system offers the advantages of stability and low device load, making it an asset for public securityaffairs and providing a reference point for future developments in surveillance hardware.展开更多
This paper aims to develop an automatic miscalibration detection and correction framework to maintain accurate calibration of LiDAR and camera for autonomous vehicle after the sensor drift.First,a monitoring algorithm...This paper aims to develop an automatic miscalibration detection and correction framework to maintain accurate calibration of LiDAR and camera for autonomous vehicle after the sensor drift.First,a monitoring algorithm that can continuously detect the miscalibration in each frame is designed,leveraging the rotational motion each individual sensor observes.Then,as sensor drift occurs,the projection constraints between visual feature points and LiDAR 3-D points are used to compute the scaled camera motion,which is further utilized to align the drifted LiDAR scan with the camera image.Finally,the proposed method is sufficiently compared with two representative approaches in the online experiments with varying levels of random drift,then the method is further extended to the offline calibration experiment and is demonstrated by a comparison with two existing benchmark methods.展开更多
Real-time indoor camera localization is a significant problem in indoor robot navigation and surveillance systems.The scene can change during the image sequence and plays a vital role in the localization performance o...Real-time indoor camera localization is a significant problem in indoor robot navigation and surveillance systems.The scene can change during the image sequence and plays a vital role in the localization performance of robotic applications in terms of accuracy and speed.This research proposed a real-time indoor camera localization system based on a recurrent neural network that detects scene change during the image sequence.An annotated image dataset trains the proposed system and predicts the camera pose in real-time.The system mainly improved the localization performance of indoor cameras by more accurately predicting the camera pose.It also recognizes the scene changes during the sequence and evaluates the effects of these changes.This system achieved high accuracy and real-time performance.The scene change detection process was performed using visual rhythm and the proposed recurrent deep architecture,which performed camera pose prediction and scene change impact evaluation.Overall,this study proposed a novel real-time localization system for indoor cameras that detects scene changes and shows how they affect localization performance.展开更多
Lattice modular robots possess diversity actuation methods, such as electric telescopic rod, gear rack, magnet, robot arm, etc. The researches on lattice modular robots mainly focus on their hardware descriptions and ...Lattice modular robots possess diversity actuation methods, such as electric telescopic rod, gear rack, magnet, robot arm, etc. The researches on lattice modular robots mainly focus on their hardware descriptions and reconfiguration algorithms. Meanwhile, their design architectures and actuation methods perform slow telescopic and moving speeds, relative low actuation force verse weight ratio, and without internal space to carry objects. To improve the mechanical performance and reveal the locomotion and reconfiguration binary essences of the lattice modular robots, a novel cube-shaped, frame-like, pneumatic-based reconfigurable robot module called pneumatic expandable cube(PE-Cube) is proposed. The three-dimensional(3D) expanding construction and omni-directional rolling analysis of the constructed robots are the main focuses. The PE-Cube with three degrees of freedom(Do Fs) is assembled by replacing the twelve edges of a cube with pneumatic cylinders. The proposed symmetric construction condition makes the constructed robots possess the same properties in each supporting state, and a binary control strategy cooperated with binary actuator(pneumatic cylinder) is directly adopted to control the PE-Cube. Taking an eight PE-Cube modules' construction as example, its dynamic rolling simulation, static rolling condition, and turning gait are illustrated and discussed. To testify telescopic synchronization, respond speed, locomotion feasibility, and repeatability and reliability of hardware system, an experimental pneumatic-based robotic system is built and the rolling and turning experiments of the eight PE-Cube modules' construction are carried out. As an extension, the locomotion feasibility of a thirty-two PE-Cube modules' construction is analyzed and proved, including dynamic rolling simulation, static rolling condition, and dynamic analysis in free tipping process. The proposed PE-Cube module, construction method, and locomotion analysis enrich the family of the lattice modular robot and provide the instruction to design the lattice modular robot.展开更多
This paper presents a design of optimal controllers with respect to a meaningful cost function to force an underactuated omni-directional intelligent navigator (ODIN) under unknown constant environmental loads to tr...This paper presents a design of optimal controllers with respect to a meaningful cost function to force an underactuated omni-directional intelligent navigator (ODIN) under unknown constant environmental loads to track a reference trajectory in two-dimensional space. Motivated by the vehicle's steering practice, the yaw angle regarded as a virtual control plus the surge thrust force are used to force the position of the vehicle to globally track its reference trajectory. The control design is based on several recent results developed for inverse optimal control and stability analysis of nonlinear systems, a new design of bounded disturbance observers, and backstepping and Lyapunov's direct methods. Both state- and output-feedback control designs are addressed. Simulations are included to illustrate the effectiveness of the proposed results.展开更多
In this paper a novel A1GalnP thin-film light-emitting diode (LED) with omni-directionally reflector (ODR) and transparent conducting indium tin oxide (ITO) n-type contact structure is proposed, and fabrication ...In this paper a novel A1GalnP thin-film light-emitting diode (LED) with omni-directionally reflector (ODR) and transparent conducting indium tin oxide (ITO) n-type contact structure is proposed, and fabrication process is developed. This reflector is realized with the combination of a low-refractive-index dielectric layer and a high reflectivity metal layer. This allows the light emitted or internally reflected downwardly towards the GaAs substrate at any angle of incidence to be reflected towards the top surface of the chip. ITO n-type contact is used for anti-reflection and current spreading layers on the ODR-LED with ITO. The sheet resistance of the ITO films (95 nm) deposited on n- ohmic contact of ODR-LED is of the order 23.5Ω/△ with up to 90% transmittance (above 92% for 590-770 nm) in the visible region of the spectrum. The optical and electrical characteristics of the ODR-LED with ITO are presented and compared to conventional AS-LED and ODR-LED without ITO. It is shown that the light output from the ODR-LED with ITO at forward current 20mA exceeds that of AS-LED and ODR-LED without ITO by about a factor of 1.63 and 0.16, respectively. A favourable luminous intensity of 218.3 mcd from the ODR-LED with ITO (peak wavelength 620 nm) could be obtained under 20 mA injection, which is 2.63 times and 1.21 times higher than that of AS-LED and ODR-LED without ITO, respectively.展开更多
Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstru...Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstructed PG and exact values, limit the effectiveness of the approach in accurate range monitoring during clinical applications. The aim of the study was to realize a PG-based dose reconstruction with a Compton camera, thereby further improving the prediction accuracy of in vivo range verification and providing a novel method for beam monitoring during proton therapy. In this paper, we present an approach based on a subset-driven origin ensemble with resolution recovery and a double evolutionary algorithm to reconstruct the dose depth profile(DDP) from the gamma events obtained by a cadmium-zinc-telluride Compton camera with limited position and energy resolution. Simulations of proton pencil beams with clinical particle rate irradiating phantoms made of different materials and the CT-based thoracic phantom were used to evaluate the feasibility of the proposed method. The results show that for the monoenergetic proton pencil beam irradiating homogeneous-material box phantom,the accuracy of the reconstructed DDP was within 0.3 mm for range prediction and within 5.2% for dose prediction. In particular, for 1.6-Gy irradiation in the therapy simulation of thoracic tumors, the range deviation of the reconstructed spreadout Bragg peak was within 0.8 mm, and the relative dose deviation in the peak area was less than 7% compared to the exact values. The results demonstrate the potential and feasibility of the proposed method in future Compton-based accurate dose reconstruction and range verification during proton therapy.展开更多
A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method wit...A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method with scattering angle correction(CSS-BP-SC) can quickly perform the back-projection process of the Compton cone and can be used to precompute the list-mode maximum likelihood expectation maximization(LM-MLEM). A dedicated parallel architecture was designed for the graphics processing unit acceleration of the back-projection and iteration stage of the CSS-BP-SC-based LM-MLEM. The imaging results of the two-point source Monte Carlo(MC) simulation demonstrate that by analyzing the full width at half maximum along the three coordinate axes, the CSS-BP-SC-based LM-MLEM can obtain imaging results comparable to those of the traditional reconstruction algorithm, that is, the simple back-projection-based LM-MLEM. The imaging results of the mouse phantom MC simulation and experiment demonstrate that the reconstruction results obtained by the proposed method sufficiently coincide with the set radioactivity distribution, and the speed increased by more than 664 times compared to the traditional reconstruction algorithm in the mouse phantom experiment. The proposed method will further advance the imaging applications of Compton cameras.展开更多
This article describes a new miniaturized omni-directional antenna with quasi-self-complementary structure for wireless communication applications. A novel ground structure composed of five rectangular plates is propo...This article describes a new miniaturized omni-directional antenna with quasi-self-complementary structure for wireless communication applications. A novel ground structure composed of five rectangular plates is proposed to enhance the impedance bandwidth and reduce the antenna size. The proposed antenna is comprised of two patches surrounded by the ground structure. Two metal patches of the antenna are located on two opposite sides of the dielectric substrate. The feed patch is used to excite the radiation patch. This unique design is realized by properly choosing the suitable feed patch shape, selecting similar slot shape on the radiation patch, and tuning their dimensions. The proposed antenna with an extremely small size of 6 mm × 9 mm has an operating impedance bandwidth ranging from 4.5 to 6.1 GHz for S<sub>11</sub> < -10 dB, which also covers the two IEEE 802.11a wireless local area network bands (5.15 - 5.35 GHz and 5.725 - 5.825 GHz). In addition to be very small in size, the antenna exhibits omni-directional radiation patterns in the entire operating bandwidth and low cross polarization. The distortionless time domain performance of the antenna is confirmed by investigation of the phase response and group delay. The obtained results in both frequency and time domain show that the proposed antenna is suitable for use in wireless communication systems.展开更多
Lanthanum bromide(LaBr_(3))crystal has a high energy resolution and time resolution and has been used in Compton cameras(CCs)over the past few decades.However,LaBr_(3) crystal arrays are difficult to process because L...Lanthanum bromide(LaBr_(3))crystal has a high energy resolution and time resolution and has been used in Compton cameras(CCs)over the past few decades.However,LaBr_(3) crystal arrays are difficult to process because LaBr_(3) is easy to crack and break;thus,few LaBr_(3)-based CC prototypes have been built.In this study,we designed and fabricated a large-pixel LaBr_(3) CC prototype and evaluated its performance with regard to position,energy,and angular resolution.We used two 10×10 LaBr_(3) crystal arrays with a pixel size of 5 mm×5 mm,silicon photomultipliers(SiPMs),and corresponding decoding circuits to construct our prototype.Additionally,a framework based on a Voronoi diagram and a lookup table was developed for list-mode projection data acquisition.Monte Carlo(MC)simulations based on Geant4 and experiments were conducted to evaluate the performance of our CC prototype.The lateral position resolution was 5 mm,and the maximum deviation in the depth direction was 2.5 and 5 mm for the scatterer and absorber,respectively.The corresponding measured energy resolu-tions were 7.65%and 8.44%,respectively,at 511 keV.The experimental results of ^(137)Cs point-like sources were consistent with the MC simulation results with regard to the spatial positions and full widths at half maximum(FWHMs).The angular resolution of the fabricated prototype was approximately 6°when a point-like ^(137)Cs source was centrally placed at a distance of 5 cm from the scatterer.We proposed and investigated a large-pixel LaBr_(3) CC for the first time and verified its feasibility for use in accurate spatial positioning of radiative sources with a high angular resolution.The proposed CC can satisfy the requirements of radiative source imaging and positioning in the nuclear industry and medical applications.展开更多
Theγ-rays are widely and abundantly present in strong nuclear radiation environments,and when they act on the camera equipment used to obtain environmental visual information on nuclear robots,radiation effects will ...Theγ-rays are widely and abundantly present in strong nuclear radiation environments,and when they act on the camera equipment used to obtain environmental visual information on nuclear robots,radiation effects will occur,which will degrade the performance of the camera system,reduce the imaging quality,and even cause catastrophic consequences.Color reducibility is an important index for evaluating the imaging quality of color camera,but its degradation mechanism in a nuclear radiation environment is still unclear.In this paper,theγ-ray irradiation experiments of CMOS cameras were carried out to analyse the degradation law of the camera’s color reducibility with cumulative irradiation and reveal the degradation mechanism of the color information of the CMOS camera underγ-ray irradiation.The results show that the spectral response of CMOS image sensor(CIS)and the spectral transmittance of lens after irradiation affect the values of a^(*)and b^(*)in the LAB color model.While the full well capacity(FWC)of CIS and transmittance of lens affect the value of L^(*)in the LAB color model,thus increase color difference and reduce brightness,the combined effect of color difference and brightness degradation will reduce the color reducibility of CMOS cameras.Therefore,the degradation of the color information of the CMOS camera afterγ-ray irradiation mainly comes from the changes in the FWC and spectral response of CIS,and the spectral transmittance of lens.展开更多
基金This work was funded by the National Natural Science Foundation of China(Grant No.62172132)Public Welfare Technology Research Project of Zhejiang Province(Grant No.LGF21F020014)the Opening Project of Key Laboratory of Public Security Information Application Based on Big-Data Architecture,Ministry of Public Security of Zhejiang Police College(Grant No.2021DSJSYS002).
文摘The widespread availability of digital multimedia data has led to a new challenge in digital forensics.Traditional source camera identification algorithms usually rely on various traces in the capturing process.However,these traces have become increasingly difficult to extract due to wide availability of various image processing algorithms.Convolutional Neural Networks(CNN)-based algorithms have demonstrated good discriminative capabilities for different brands and even different models of camera devices.However,their performances is not ideal in case of distinguishing between individual devices of the same model,because cameras of the same model typically use the same optical lens,image sensor,and image processing algorithms,that result in minimal overall differences.In this paper,we propose a camera forensics algorithm based on multi-scale feature fusion to address these issues.The proposed algorithm extracts different local features from feature maps of different scales and then fuses them to obtain a comprehensive feature representation.This representation is then fed into a subsequent camera fingerprint classification network.Building upon the Swin-T network,we utilize Transformer Blocks and Graph Convolutional Network(GCN)modules to fuse multi-scale features from different stages of the backbone network.Furthermore,we conduct experiments on established datasets to demonstrate the feasibility and effectiveness of the proposed approach.
基金National Natural Science Foundation of China(NSFC)(No.11775147)Guangdong Basic and Applied Basic Research Foundation(Nos.2019A1515110130 and 2024A1515011832)+1 种基金Shenzhen Key Laboratory of Photonics and Biophotonics(ZDSYS20210623092006020)Shenzhen Science and Technology Program(Nos.JCYJ20210324095007020,JCYJ20200109105201936 and JCYJ20230808105019039).
文摘An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps.
基金the Social Development Project of Jiangsu Key R&D Program(BE2022680)the National Natural Science Foundation of China(Nos.62371253,52278119).
文摘This paper introduces an intelligent computational approach for extracting salient objects fromimages and estimatingtheir distance information with PTZ (Pan-Tilt-Zoom) cameras. PTZ cameras have found wide applications innumerous public places, serving various purposes such as public securitymanagement, natural disastermonitoring,and crisis alarms, particularly with the rapid development of Artificial Intelligence and global infrastructuralprojects. In this paper, we combine Gauss optical principles with the PTZ camera’s capabilities of horizontal andpitch rotation, as well as optical zoom, to estimate the distance of the object.We present a novel monocular objectdistance estimation model based on the Focal Length-Target Pixel Size (FLTPS) relationship, achieving an accuracyrate of over 95% for objects within a 5 km range. The salient object extraction is achieved through a simplifiedconvolution kernel and the utilization of the object’s RGB features, which offer significantly faster computingspeeds compared to Convolutional Neural Networks (CNNs). Additionally, we introduce the dark channel beforethe fog removal algorithm, resulting in a 20 dB increase in image definition, which significantly benefits distanceestimation. Our system offers the advantages of stability and low device load, making it an asset for public securityaffairs and providing a reference point for future developments in surveillance hardware.
基金Supported by National Natural Science Foundation of China(Grant Nos.52025121,52394263)National Key R&D Plan of China(Grant No.2023YFD2000301).
文摘This paper aims to develop an automatic miscalibration detection and correction framework to maintain accurate calibration of LiDAR and camera for autonomous vehicle after the sensor drift.First,a monitoring algorithm that can continuously detect the miscalibration in each frame is designed,leveraging the rotational motion each individual sensor observes.Then,as sensor drift occurs,the projection constraints between visual feature points and LiDAR 3-D points are used to compute the scaled camera motion,which is further utilized to align the drifted LiDAR scan with the camera image.Finally,the proposed method is sufficiently compared with two representative approaches in the online experiments with varying levels of random drift,then the method is further extended to the offline calibration experiment and is demonstrated by a comparison with two existing benchmark methods.
文摘Real-time indoor camera localization is a significant problem in indoor robot navigation and surveillance systems.The scene can change during the image sequence and plays a vital role in the localization performance of robotic applications in terms of accuracy and speed.This research proposed a real-time indoor camera localization system based on a recurrent neural network that detects scene change during the image sequence.An annotated image dataset trains the proposed system and predicts the camera pose in real-time.The system mainly improved the localization performance of indoor cameras by more accurately predicting the camera pose.It also recognizes the scene changes during the sequence and evaluates the effects of these changes.This system achieved high accuracy and real-time performance.The scene change detection process was performed using visual rhythm and the proposed recurrent deep architecture,which performed camera pose prediction and scene change impact evaluation.Overall,this study proposed a novel real-time localization system for indoor cameras that detects scene changes and shows how they affect localization performance.
基金Supported by National Natural Science Foundation of China(Grant No.51175030)Fundamental Research Funds for the Central Universities,China(Grant No.2012JBZ002)+1 种基金Research Fund for the Doctoral Program of Higher Education(Grant No.20130009110030)Major Project of Ministry of Education of China(Grant No.625010403)
文摘Lattice modular robots possess diversity actuation methods, such as electric telescopic rod, gear rack, magnet, robot arm, etc. The researches on lattice modular robots mainly focus on their hardware descriptions and reconfiguration algorithms. Meanwhile, their design architectures and actuation methods perform slow telescopic and moving speeds, relative low actuation force verse weight ratio, and without internal space to carry objects. To improve the mechanical performance and reveal the locomotion and reconfiguration binary essences of the lattice modular robots, a novel cube-shaped, frame-like, pneumatic-based reconfigurable robot module called pneumatic expandable cube(PE-Cube) is proposed. The three-dimensional(3D) expanding construction and omni-directional rolling analysis of the constructed robots are the main focuses. The PE-Cube with three degrees of freedom(Do Fs) is assembled by replacing the twelve edges of a cube with pneumatic cylinders. The proposed symmetric construction condition makes the constructed robots possess the same properties in each supporting state, and a binary control strategy cooperated with binary actuator(pneumatic cylinder) is directly adopted to control the PE-Cube. Taking an eight PE-Cube modules' construction as example, its dynamic rolling simulation, static rolling condition, and turning gait are illustrated and discussed. To testify telescopic synchronization, respond speed, locomotion feasibility, and repeatability and reliability of hardware system, an experimental pneumatic-based robotic system is built and the rolling and turning experiments of the eight PE-Cube modules' construction are carried out. As an extension, the locomotion feasibility of a thirty-two PE-Cube modules' construction is analyzed and proved, including dynamic rolling simulation, static rolling condition, and dynamic analysis in free tipping process. The proposed PE-Cube module, construction method, and locomotion analysis enrich the family of the lattice modular robot and provide the instruction to design the lattice modular robot.
基金Supported in Part by the Australian Research Council under Grant DP0988424
文摘This paper presents a design of optimal controllers with respect to a meaningful cost function to force an underactuated omni-directional intelligent navigator (ODIN) under unknown constant environmental loads to track a reference trajectory in two-dimensional space. Motivated by the vehicle's steering practice, the yaw angle regarded as a virtual control plus the surge thrust force are used to force the position of the vehicle to globally track its reference trajectory. The control design is based on several recent results developed for inverse optimal control and stability analysis of nonlinear systems, a new design of bounded disturbance observers, and backstepping and Lyapunov's direct methods. Both state- and output-feedback control designs are addressed. Simulations are included to illustrate the effectiveness of the proposed results.
文摘In this paper a novel A1GalnP thin-film light-emitting diode (LED) with omni-directionally reflector (ODR) and transparent conducting indium tin oxide (ITO) n-type contact structure is proposed, and fabrication process is developed. This reflector is realized with the combination of a low-refractive-index dielectric layer and a high reflectivity metal layer. This allows the light emitted or internally reflected downwardly towards the GaAs substrate at any angle of incidence to be reflected towards the top surface of the chip. ITO n-type contact is used for anti-reflection and current spreading layers on the ODR-LED with ITO. The sheet resistance of the ITO films (95 nm) deposited on n- ohmic contact of ODR-LED is of the order 23.5Ω/△ with up to 90% transmittance (above 92% for 590-770 nm) in the visible region of the spectrum. The optical and electrical characteristics of the ODR-LED with ITO are presented and compared to conventional AS-LED and ODR-LED without ITO. It is shown that the light output from the ODR-LED with ITO at forward current 20mA exceeds that of AS-LED and ODR-LED without ITO by about a factor of 1.63 and 0.16, respectively. A favourable luminous intensity of 218.3 mcd from the ODR-LED with ITO (peak wavelength 620 nm) could be obtained under 20 mA injection, which is 2.63 times and 1.21 times higher than that of AS-LED and ODR-LED without ITO, respectively.
基金supported by Natural Science Foundation of Beijing Municipality (Beijing Natural Science Foundation)(No.7191005)。
文摘Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstructed PG and exact values, limit the effectiveness of the approach in accurate range monitoring during clinical applications. The aim of the study was to realize a PG-based dose reconstruction with a Compton camera, thereby further improving the prediction accuracy of in vivo range verification and providing a novel method for beam monitoring during proton therapy. In this paper, we present an approach based on a subset-driven origin ensemble with resolution recovery and a double evolutionary algorithm to reconstruct the dose depth profile(DDP) from the gamma events obtained by a cadmium-zinc-telluride Compton camera with limited position and energy resolution. Simulations of proton pencil beams with clinical particle rate irradiating phantoms made of different materials and the CT-based thoracic phantom were used to evaluate the feasibility of the proposed method. The results show that for the monoenergetic proton pencil beam irradiating homogeneous-material box phantom,the accuracy of the reconstructed DDP was within 0.3 mm for range prediction and within 5.2% for dose prediction. In particular, for 1.6-Gy irradiation in the therapy simulation of thoracic tumors, the range deviation of the reconstructed spreadout Bragg peak was within 0.8 mm, and the relative dose deviation in the peak area was less than 7% compared to the exact values. The results demonstrate the potential and feasibility of the proposed method in future Compton-based accurate dose reconstruction and range verification during proton therapy.
基金supported by the National Natural Science Foundation of China (No. 12220101005)Natural Science Foundation of Jiangsu Province (No. BK20220132)+2 种基金Primary Research and Development Plan of Jiangsu Province (No. BE2019002-3)Fundamental Research Funds for Central Universities (No. NG2022004)the Foundation of the Graduate Innovation Center in NUAA (No. xcxjh20210613)。
文摘A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method with scattering angle correction(CSS-BP-SC) can quickly perform the back-projection process of the Compton cone and can be used to precompute the list-mode maximum likelihood expectation maximization(LM-MLEM). A dedicated parallel architecture was designed for the graphics processing unit acceleration of the back-projection and iteration stage of the CSS-BP-SC-based LM-MLEM. The imaging results of the two-point source Monte Carlo(MC) simulation demonstrate that by analyzing the full width at half maximum along the three coordinate axes, the CSS-BP-SC-based LM-MLEM can obtain imaging results comparable to those of the traditional reconstruction algorithm, that is, the simple back-projection-based LM-MLEM. The imaging results of the mouse phantom MC simulation and experiment demonstrate that the reconstruction results obtained by the proposed method sufficiently coincide with the set radioactivity distribution, and the speed increased by more than 664 times compared to the traditional reconstruction algorithm in the mouse phantom experiment. The proposed method will further advance the imaging applications of Compton cameras.
文摘This article describes a new miniaturized omni-directional antenna with quasi-self-complementary structure for wireless communication applications. A novel ground structure composed of five rectangular plates is proposed to enhance the impedance bandwidth and reduce the antenna size. The proposed antenna is comprised of two patches surrounded by the ground structure. Two metal patches of the antenna are located on two opposite sides of the dielectric substrate. The feed patch is used to excite the radiation patch. This unique design is realized by properly choosing the suitable feed patch shape, selecting similar slot shape on the radiation patch, and tuning their dimensions. The proposed antenna with an extremely small size of 6 mm × 9 mm has an operating impedance bandwidth ranging from 4.5 to 6.1 GHz for S<sub>11</sub> < -10 dB, which also covers the two IEEE 802.11a wireless local area network bands (5.15 - 5.35 GHz and 5.725 - 5.825 GHz). In addition to be very small in size, the antenna exhibits omni-directional radiation patterns in the entire operating bandwidth and low cross polarization. The distortionless time domain performance of the antenna is confirmed by investigation of the phase response and group delay. The obtained results in both frequency and time domain show that the proposed antenna is suitable for use in wireless communication systems.
文摘Lanthanum bromide(LaBr_(3))crystal has a high energy resolution and time resolution and has been used in Compton cameras(CCs)over the past few decades.However,LaBr_(3) crystal arrays are difficult to process because LaBr_(3) is easy to crack and break;thus,few LaBr_(3)-based CC prototypes have been built.In this study,we designed and fabricated a large-pixel LaBr_(3) CC prototype and evaluated its performance with regard to position,energy,and angular resolution.We used two 10×10 LaBr_(3) crystal arrays with a pixel size of 5 mm×5 mm,silicon photomultipliers(SiPMs),and corresponding decoding circuits to construct our prototype.Additionally,a framework based on a Voronoi diagram and a lookup table was developed for list-mode projection data acquisition.Monte Carlo(MC)simulations based on Geant4 and experiments were conducted to evaluate the performance of our CC prototype.The lateral position resolution was 5 mm,and the maximum deviation in the depth direction was 2.5 and 5 mm for the scatterer and absorber,respectively.The corresponding measured energy resolu-tions were 7.65%and 8.44%,respectively,at 511 keV.The experimental results of ^(137)Cs point-like sources were consistent with the MC simulation results with regard to the spatial positions and full widths at half maximum(FWHMs).The angular resolution of the fabricated prototype was approximately 6°when a point-like ^(137)Cs source was centrally placed at a distance of 5 cm from the scatterer.We proposed and investigated a large-pixel LaBr_(3) CC for the first time and verified its feasibility for use in accurate spatial positioning of radiative sources with a high angular resolution.The proposed CC can satisfy the requirements of radiative source imaging and positioning in the nuclear industry and medical applications.
基金National Natural Science Foundation of China(11805269)West Light Talent Training Plan of the Chinese Academy of Sciences(2022-XBQNXZ-010)Science and Technology Innovation Leading Talent Project of Xinjiang Uygur Autonomous Region(2022TSYCLJ0042)。
文摘Theγ-rays are widely and abundantly present in strong nuclear radiation environments,and when they act on the camera equipment used to obtain environmental visual information on nuclear robots,radiation effects will occur,which will degrade the performance of the camera system,reduce the imaging quality,and even cause catastrophic consequences.Color reducibility is an important index for evaluating the imaging quality of color camera,but its degradation mechanism in a nuclear radiation environment is still unclear.In this paper,theγ-ray irradiation experiments of CMOS cameras were carried out to analyse the degradation law of the camera’s color reducibility with cumulative irradiation and reveal the degradation mechanism of the color information of the CMOS camera underγ-ray irradiation.The results show that the spectral response of CMOS image sensor(CIS)and the spectral transmittance of lens after irradiation affect the values of a^(*)and b^(*)in the LAB color model.While the full well capacity(FWC)of CIS and transmittance of lens affect the value of L^(*)in the LAB color model,thus increase color difference and reduce brightness,the combined effect of color difference and brightness degradation will reduce the color reducibility of CMOS cameras.Therefore,the degradation of the color information of the CMOS camera afterγ-ray irradiation mainly comes from the changes in the FWC and spectral response of CIS,and the spectral transmittance of lens.