Objective To analyze the short-term outcomes of redo coronary artery bypass grafting(CABG) using on-pump and off-pump CABG techniques. Methods From January 2003 to August 2013, non-randomized 80 patients were treated ...Objective To analyze the short-term outcomes of redo coronary artery bypass grafting(CABG) using on-pump and off-pump CABG techniques. Methods From January 2003 to August 2013, non-randomized 80 patients were treated with redo CABG in the Department of Cardiac Surgery, Peking University Third Hospital. Among these patients, 40 underwent on-pump CABG technique(redo-ONCAB group) and 40 underwent off-pump CABG technique(redo-OPCAB group). Furthermore, transmyocardial laser revascularization was performed in high-risk patients who were not suitable to conventional grafting. Clinical data of the two groups were recorded and analyzed including operation time, coronary grafts, incomplete revascularization, postoperative ventilation, perioperative stroke, and low output syndrome, etc. Results There were no significantly differences in age, gender distribution, incidences of hypertension, stroke, and other clinical characteristics between redo-OPCAB group and redo-ONCAB group(all P>0.05), except for incidences of renal dysfunction and pulmonary disease(all P<0.05). The number of grafting vessels in the redo-ONCAB and redo-OPCAB groups was 2.1 ± 0.74 and 1.4 ±0.52 respectively. There was significant difference between the two groups(P=0.0243). Compared with the redo-ONCAB group, there was shorter operation time(P=0.0045), postoperative ventilation(P=0.0211) and intensive care unit stay(P=0.0400), as well as fewer use of platelet(P=0.0338) and blood transfusion(P=0.0034) in the redo-OPCAB group. The incidence of incomplete revascularization(P=0.0253) and the use of transmyocardial laser revascularization(P=0.0052) were higher in the redo-OPCAB group than those in the redo-ONCAB group(all P<0.05). However, no significant differences were showed for the incidence of the use of intra aortic balloon pump and continuous renal replacement therapy, perioperative stroke, low output syndrome, and in-hospital mortality between the two groups(all P>0.05). Conclusion Redo CABG is the safety and efficacy surgical procedure, and redo-OPCAB technique with better outcomes is commended especially in high-risk patients.展开更多
We study the possible topological phase in a one-dimensional(1D) quantum wire with an oscillating Rashba spin–orbital coupling in real space. It is shown that there are a pair of particle–hole symmetric gaps formi...We study the possible topological phase in a one-dimensional(1D) quantum wire with an oscillating Rashba spin–orbital coupling in real space. It is shown that there are a pair of particle–hole symmetric gaps forming in the bulk energy band and fractional boundary states residing in the gap when the system has an inversion symmetry. These states are topologically nontrivial and can be characterized by a quantized Berry phase ±π or nonzero Chern number through dimensional extension. When the Rashba spin–orbital coupling varies slowly with time, the system can pump out 2 charges in a pumping cycle because of the spin flip effect. This quantized pumping is protected by topology and is robust against moderate disorders as long as the disorder strength does not exceed the opened energy gap.展开更多
文摘Objective To analyze the short-term outcomes of redo coronary artery bypass grafting(CABG) using on-pump and off-pump CABG techniques. Methods From January 2003 to August 2013, non-randomized 80 patients were treated with redo CABG in the Department of Cardiac Surgery, Peking University Third Hospital. Among these patients, 40 underwent on-pump CABG technique(redo-ONCAB group) and 40 underwent off-pump CABG technique(redo-OPCAB group). Furthermore, transmyocardial laser revascularization was performed in high-risk patients who were not suitable to conventional grafting. Clinical data of the two groups were recorded and analyzed including operation time, coronary grafts, incomplete revascularization, postoperative ventilation, perioperative stroke, and low output syndrome, etc. Results There were no significantly differences in age, gender distribution, incidences of hypertension, stroke, and other clinical characteristics between redo-OPCAB group and redo-ONCAB group(all P>0.05), except for incidences of renal dysfunction and pulmonary disease(all P<0.05). The number of grafting vessels in the redo-ONCAB and redo-OPCAB groups was 2.1 ± 0.74 and 1.4 ±0.52 respectively. There was significant difference between the two groups(P=0.0243). Compared with the redo-ONCAB group, there was shorter operation time(P=0.0045), postoperative ventilation(P=0.0211) and intensive care unit stay(P=0.0400), as well as fewer use of platelet(P=0.0338) and blood transfusion(P=0.0034) in the redo-OPCAB group. The incidence of incomplete revascularization(P=0.0253) and the use of transmyocardial laser revascularization(P=0.0052) were higher in the redo-OPCAB group than those in the redo-ONCAB group(all P<0.05). However, no significant differences were showed for the incidence of the use of intra aortic balloon pump and continuous renal replacement therapy, perioperative stroke, low output syndrome, and in-hospital mortality between the two groups(all P>0.05). Conclusion Redo CABG is the safety and efficacy surgical procedure, and redo-OPCAB technique with better outcomes is commended especially in high-risk patients.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.115074045 and 11204187)the Natural Science Foundation of Jiangsu Province,China(Grant No.BK20131284)
文摘We study the possible topological phase in a one-dimensional(1D) quantum wire with an oscillating Rashba spin–orbital coupling in real space. It is shown that there are a pair of particle–hole symmetric gaps forming in the bulk energy band and fractional boundary states residing in the gap when the system has an inversion symmetry. These states are topologically nontrivial and can be characterized by a quantized Berry phase ±π or nonzero Chern number through dimensional extension. When the Rashba spin–orbital coupling varies slowly with time, the system can pump out 2 charges in a pumping cycle because of the spin flip effect. This quantized pumping is protected by topology and is robust against moderate disorders as long as the disorder strength does not exceed the opened energy gap.