Microfluidic analytical system was developed based on annular flow of phase separation multiphase flow with a ternary water-hydrophilic/hydrophobic organic solvent solution. The analytical system was combined with on-...Microfluidic analytical system was developed based on annular flow of phase separation multiphase flow with a ternary water-hydrophilic/hydrophobic organic solvent solution. The analytical system was combined with on-line luminol chemiluminescence detection for catechin analysis. The water (10 mM phosphate buffer, pH 7.3)-acetonitrile-ethyl acetate mixed solution (3:8:4, volume ratio) containing 60 μM luminol and 2 mM hydrogen peroxide as a carrier was fed into the capillary tube (open-tubular fused-silica, 75 μm inner diameter, 110 cm effective length) at a flow rate of 1.0 μL·min-1. The carrier solution showed stable chemiluminescence as a baseline on the flow chart. Eight catechins were detected as negative peaks for their antioxidant potential with different detection times. The system was applied to analyze the amounts of catechin in commercially available green tea beverages.展开更多
A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 m...A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 mm i.d.) for enrichment and separation was developed and validated to determine low levels of methotrexate (MTX). The method was based on oxidative cleavage of MTX into highly fluorescence products, 2,4-diaminopteridine-6-carboxaldehyde and the corresponding 2,4-diaminopteridine-6-carboxylic acid, during the flow of phosphate buffer (0.04 M, pH 3.4) containing the analyte through the packed reactor of cerium (IV) trihydroxyhydroperoxide (CTH) at a flow-rate of 0.2 mL/min and 40℃. The fluorescent products were enriched on the head of ODS analytical column for the final separation. The separation was performed at room temperature using an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 10:90 (v/v). The eluent was monitored at emission and excitation wavelengths of 463 and 367 nm, respectively. The method was successfully applied, without any interference from the excipients, for the determination of drug in tablets and vials with a detection limit of 0.06 ng/mL from 500 ?L of sample MTX.展开更多
Biosensors, which are the products of the biotechnology industry, are among the key projects of the 7th, 8th, and 9th Fiveyear Plans of China Science & Technology Developing Programs, respectively, and they play an i...Biosensors, which are the products of the biotechnology industry, are among the key projects of the 7th, 8th, and 9th Fiveyear Plans of China Science & Technology Developing Programs, respectively, and they play an important role in developing and reforming traditional biotechnology. SBA series biosensor analyzer, as the only one commercial biosensor in China, has attracted lots of attention in the process of information gathering and measurement for biological industry with the development of technology and society. In this paper, we presented an overview of the most important contributions dealing with the monitoring of the biochemical analytes in fermentation processes using SBA series biosensor analyzers in China. Future trends of the biosensor analyzer in China were also mentioned in the last section.展开更多
The results of data cube will occupy huge amount of disk space when the base table is of a large number of attributes. A new type of data cube, compact data cube like condensed cube and quotient cube, was proposed to ...The results of data cube will occupy huge amount of disk space when the base table is of a large number of attributes. A new type of data cube, compact data cube like condensed cube and quotient cube, was proposed to solve the problem. It compresses data cube dramatically. However, its query cost is so high that it cannot be used in most applications. This paper introduces the semi-closed cube to reduce the size of data cube and achieve almost the same query response time as the data cube does. Semi-closed cube is a generalization of condensed cube and quotient cube and is constructed from a quotient cube. When the query cost of quotient cube is higher than a given threshold, semi-closed cube selects some views and picks a fellow for each of them. All the tuples of those views are materialized except those closed by their fellows. To find a tuple of those views, users only need to scan the view and its fellow. Thus, their query performance is improved. Experiments were conducted using a real-world data set. The results show that semi-closed cube is an effective approach of data cube.展开更多
文摘Microfluidic analytical system was developed based on annular flow of phase separation multiphase flow with a ternary water-hydrophilic/hydrophobic organic solvent solution. The analytical system was combined with on-line luminol chemiluminescence detection for catechin analysis. The water (10 mM phosphate buffer, pH 7.3)-acetonitrile-ethyl acetate mixed solution (3:8:4, volume ratio) containing 60 μM luminol and 2 mM hydrogen peroxide as a carrier was fed into the capillary tube (open-tubular fused-silica, 75 μm inner diameter, 110 cm effective length) at a flow rate of 1.0 μL·min-1. The carrier solution showed stable chemiluminescence as a baseline on the flow chart. Eight catechins were detected as negative peaks for their antioxidant potential with different detection times. The system was applied to analyze the amounts of catechin in commercially available green tea beverages.
文摘A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 mm i.d.) for enrichment and separation was developed and validated to determine low levels of methotrexate (MTX). The method was based on oxidative cleavage of MTX into highly fluorescence products, 2,4-diaminopteridine-6-carboxaldehyde and the corresponding 2,4-diaminopteridine-6-carboxylic acid, during the flow of phosphate buffer (0.04 M, pH 3.4) containing the analyte through the packed reactor of cerium (IV) trihydroxyhydroperoxide (CTH) at a flow-rate of 0.2 mL/min and 40℃. The fluorescent products were enriched on the head of ODS analytical column for the final separation. The separation was performed at room temperature using an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 10:90 (v/v). The eluent was monitored at emission and excitation wavelengths of 463 and 367 nm, respectively. The method was successfully applied, without any interference from the excipients, for the determination of drug in tablets and vials with a detection limit of 0.06 ng/mL from 500 ?L of sample MTX.
基金Supported by the Postdoctoral Innovation Fund of Shandong Province(201303032)the Independent Innovation Projects of Shandong Province(2012CX20505)the National 863 High Technology Project of the Ministry of Science and Technology of China(2012AA021201)
文摘Biosensors, which are the products of the biotechnology industry, are among the key projects of the 7th, 8th, and 9th Fiveyear Plans of China Science & Technology Developing Programs, respectively, and they play an important role in developing and reforming traditional biotechnology. SBA series biosensor analyzer, as the only one commercial biosensor in China, has attracted lots of attention in the process of information gathering and measurement for biological industry with the development of technology and society. In this paper, we presented an overview of the most important contributions dealing with the monitoring of the biochemical analytes in fermentation processes using SBA series biosensor analyzers in China. Future trends of the biosensor analyzer in China were also mentioned in the last section.
文摘The results of data cube will occupy huge amount of disk space when the base table is of a large number of attributes. A new type of data cube, compact data cube like condensed cube and quotient cube, was proposed to solve the problem. It compresses data cube dramatically. However, its query cost is so high that it cannot be used in most applications. This paper introduces the semi-closed cube to reduce the size of data cube and achieve almost the same query response time as the data cube does. Semi-closed cube is a generalization of condensed cube and quotient cube and is constructed from a quotient cube. When the query cost of quotient cube is higher than a given threshold, semi-closed cube selects some views and picks a fellow for each of them. All the tuples of those views are materialized except those closed by their fellows. To find a tuple of those views, users only need to scan the view and its fellow. Thus, their query performance is improved. Experiments were conducted using a real-world data set. The results show that semi-closed cube is an effective approach of data cube.