The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been propos...The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been proposed for the determination of nitrite at nanomolar level to illustrate the role of nitrite in the marine nitrogen cycle. However, most of previous reports are not widely accepted, because of their complexity and cost equipment or intensive labor requirement. In this study, a simple automatic system for the determination of nanomolar level nitrite using on-line preconcentration with spectrophotometric detection was described..An Oasis HLB cartridge was adopted to quantitatively enrich the pink-colored azo compound, formed from nitrite via Griess reaction. The cartridge was rinsed with water and ethanol (volume fraction is 55%, the same below), in turn, then eluted by an eluent containing 50% ethanol and 0.25 M(mol/dm^3) H2SO4, and determined at 543 nm with a 2 cm path-length flow cell. Under the optimized experimental conditions, the calibration curve showed a good linearity in the range of 1.4 85.7 aM, and the LOD (3a) was estimated to be 0.5 nM. The relative standard deviations of 7 measurements were 4.0% and 1.0% for the samples spiked at 7.1 and 28.6 nM, respectively. The recoveries for the different natural water samples were between 92.2%-108.4%. Each HLB cartridge could be reused for at least 50 times. As compared with other SPE methods, the advantages of this method included the free of interference from salinity variation and less sample consuming. The results of the application of the proposed method to natural water showed good agreement with liquid waveguide capillary cell detection method.展开更多
A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast a...A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5).展开更多
The online flow injection preconcentration and electrothermal atomic absorption spectrometry method were used for the determination of trace nickel in electrolytic manganese samples by sorption on a conical minicolumn...The online flow injection preconcentration and electrothermal atomic absorption spectrometry method were used for the determination of trace nickel in electrolytic manganese samples by sorption on a conical minicolumn packed with activated carbon at pH 9.0. The nickel was eluted from the minicolumn with 10%(v/v) nitric acid. An enrichment factor of 190-fold for a sample volume of 10mL was obtained. The detection limit (DL) of nickel with the use of the preconcentration method was 13ng·g -1in the original solid sample. The precision for 10 replicate determinations at 150ng·g -1 nickel concentration was 5.2% relative standard deviation (RSD). The calibration graph was linear with a correlation coefficient of r=0.9996 up to concentration of 660ng·g -1 nickel.展开更多
An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determinatio...An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples.展开更多
A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn pac...A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments.展开更多
The suitability of 1-nitroso-2-naphthol(NN) as a complexing agent for on-line preconcentration of cobalt eluted on the C_(18) microcolumn by means of the FI-FAAS system was tested. Various parameters affecting the com...The suitability of 1-nitroso-2-naphthol(NN) as a complexing agent for on-line preconcentration of cobalt eluted on the C_(18) microcolumn by means of the FI-FAAS system was tested. Various parameters affecting the complex formation and its elution were optimized. A 2.3×10^(-3) mol/L reagent solution and the aqueous sample solution acidified with 0.1% (volume fraction) nitric acid were on-line mixed (6.4 mL/min) on a reaction coil set at (65±1)℃ and flowed through the microcolumn for 30 s. The pH of the mixed solution was adjusted to 3—4 with HNO_3(1 mol/L) or NaOH(1 mol/L). The adsorbed complexes in the microcolumn were eluted into the nebulizer of FAAS in 10 s with ethanol acidified with 1% HNO_3(3.0 mL/min). A good precision(1.6% for 100μg/L Co(Ⅱ), n=10), a high enrichment factor 17.2, with detection limit (3σ) 3.2μg/L, and sample throughput (90 h^(-1)) were obtained. The method was applied to the certified reference materials(CRMs), NBS-362 and NBS-364, for the determination of cobalt and the results were in good agreement with the certified values.展开更多
This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inerti...This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature.展开更多
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(...On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%.展开更多
A quite new type of chelating resin Carboxymethylated Polyethylenimine-Polymethylenepolyphenylene Isocyanate(CPPI)is used for the preconcentration of Zn from high salt water such as seawater. The preconcentration is c...A quite new type of chelating resin Carboxymethylated Polyethylenimine-Polymethylenepolyphenylene Isocyanate(CPPI)is used for the preconcentration of Zn from high salt water such as seawater. The preconcentration is controlled through the technique of Flow Injection Analysis(FIA).The concentrated sample solution is then directly transferred to an Inductively Coupled Plasma-Atomic Fluorescence Spectrometer(ICP-AFS)for determination.The detection limit of Zn by the technique is about 0.06 ppb.展开更多
The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination ...The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination reaction by melt coextrusion.Beside evenly mixing of poly(hexamethylene guanidine)(PHMG)and PET in the melt coextrusion procedure,the amination reaction also occurred between PHMG and PET under high temperature(230-270℃).The antibacterial ability of composite PET showed obvious PHMG concentration dependence,and antibacterial activity reached more than 99%when PHMG content was 2.5 wt%.Moreover,LIVE/DEAD fluorescence test further confirmed that the composite PET could kill bacteria quickly and efiectively(within 30 min);while negligible cytotoxicity was observed to HSF and HUVEC cells.Onestep eco-friendly fabrication of composite antibacterial PET was accomplished by on-line melt coextrusion.The composite antibacterial PET has potential use in multiple fields to combat with pathogenic including textiles,packaging materials,decoration materials and biomedical devices,etc.展开更多
This article focuses on iodine determination by microwave plasma torch atomic emission spectrometry (MPT-AES) coupled with online preconcentration vapor generation method. A new desolvation device, multistrand Nafio...This article focuses on iodine determination by microwave plasma torch atomic emission spectrometry (MPT-AES) coupled with online preconcentration vapor generation method. A new desolvation device, multistrand Nafion dryer, was used as the substitute for condenser desolvation system. Some experimental conditions, such as preconcentration time, acidity of sample solution, rinsing solution acidity and dynamic linear range were investigated and optimized. The new desolvation system eliminates the problem of decreasing emission intensity of I(I) 206.238 nm line with the increase of working time on a conventional condenser desolvation system, thus greatly improving the reproducibility.展开更多
基金The National High Technology Research and Development Program of China under contract Nos 2006AA09Z174 and 2007AA061501the National Natural Science Foundation of China under contract No. 40521003
文摘The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been proposed for the determination of nitrite at nanomolar level to illustrate the role of nitrite in the marine nitrogen cycle. However, most of previous reports are not widely accepted, because of their complexity and cost equipment or intensive labor requirement. In this study, a simple automatic system for the determination of nanomolar level nitrite using on-line preconcentration with spectrophotometric detection was described..An Oasis HLB cartridge was adopted to quantitatively enrich the pink-colored azo compound, formed from nitrite via Griess reaction. The cartridge was rinsed with water and ethanol (volume fraction is 55%, the same below), in turn, then eluted by an eluent containing 50% ethanol and 0.25 M(mol/dm^3) H2SO4, and determined at 543 nm with a 2 cm path-length flow cell. Under the optimized experimental conditions, the calibration curve showed a good linearity in the range of 1.4 85.7 aM, and the LOD (3a) was estimated to be 0.5 nM. The relative standard deviations of 7 measurements were 4.0% and 1.0% for the samples spiked at 7.1 and 28.6 nM, respectively. The recoveries for the different natural water samples were between 92.2%-108.4%. Each HLB cartridge could be reused for at least 50 times. As compared with other SPE methods, the advantages of this method included the free of interference from salinity variation and less sample consuming. The results of the application of the proposed method to natural water showed good agreement with liquid waveguide capillary cell detection method.
文摘A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5).
文摘The online flow injection preconcentration and electrothermal atomic absorption spectrometry method were used for the determination of trace nickel in electrolytic manganese samples by sorption on a conical minicolumn packed with activated carbon at pH 9.0. The nickel was eluted from the minicolumn with 10%(v/v) nitric acid. An enrichment factor of 190-fold for a sample volume of 10mL was obtained. The detection limit (DL) of nickel with the use of the preconcentration method was 13ng·g -1in the original solid sample. The precision for 10 replicate determinations at 150ng·g -1 nickel concentration was 5.2% relative standard deviation (RSD). The calibration graph was linear with a correlation coefficient of r=0.9996 up to concentration of 660ng·g -1 nickel.
基金Supported by the Fund of State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemi-stry, Chinese Academy of Sciences(No.RERU2011006)
文摘An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples.
基金This work has been funded by the Spain’s Ministry of Science and Innovation,within the framework of Project CTQ2009-12282.
文摘A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments.
基金Supported by Zhejiang Natural Science Foundation of China.
文摘The suitability of 1-nitroso-2-naphthol(NN) as a complexing agent for on-line preconcentration of cobalt eluted on the C_(18) microcolumn by means of the FI-FAAS system was tested. Various parameters affecting the complex formation and its elution were optimized. A 2.3×10^(-3) mol/L reagent solution and the aqueous sample solution acidified with 0.1% (volume fraction) nitric acid were on-line mixed (6.4 mL/min) on a reaction coil set at (65±1)℃ and flowed through the microcolumn for 30 s. The pH of the mixed solution was adjusted to 3—4 with HNO_3(1 mol/L) or NaOH(1 mol/L). The adsorbed complexes in the microcolumn were eluted into the nebulizer of FAAS in 10 s with ethanol acidified with 1% HNO_3(3.0 mL/min). A good precision(1.6% for 100μg/L Co(Ⅱ), n=10), a high enrichment factor 17.2, with detection limit (3σ) 3.2μg/L, and sample throughput (90 h^(-1)) were obtained. The method was applied to the certified reference materials(CRMs), NBS-362 and NBS-364, for the determination of cobalt and the results were in good agreement with the certified values.
文摘This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature.
文摘On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%.
文摘A quite new type of chelating resin Carboxymethylated Polyethylenimine-Polymethylenepolyphenylene Isocyanate(CPPI)is used for the preconcentration of Zn from high salt water such as seawater. The preconcentration is controlled through the technique of Flow Injection Analysis(FIA).The concentrated sample solution is then directly transferred to an Inductively Coupled Plasma-Atomic Fluorescence Spectrometer(ICP-AFS)for determination.The detection limit of Zn by the technique is about 0.06 ppb.
基金Funded by the National Natural Science Foundation of China(No.51703169)Key Program of Science and Technology of Jieyang City(No.2019016)Key Research and Development Program of Shandong Province of China(No.2019JZZY010338)。
文摘The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination reaction by melt coextrusion.Beside evenly mixing of poly(hexamethylene guanidine)(PHMG)and PET in the melt coextrusion procedure,the amination reaction also occurred between PHMG and PET under high temperature(230-270℃).The antibacterial ability of composite PET showed obvious PHMG concentration dependence,and antibacterial activity reached more than 99%when PHMG content was 2.5 wt%.Moreover,LIVE/DEAD fluorescence test further confirmed that the composite PET could kill bacteria quickly and efiectively(within 30 min);while negligible cytotoxicity was observed to HSF and HUVEC cells.Onestep eco-friendly fabrication of composite antibacterial PET was accomplished by on-line melt coextrusion.The composite antibacterial PET has potential use in multiple fields to combat with pathogenic including textiles,packaging materials,decoration materials and biomedical devices,etc.
基金the Key Project for Science and Technology Development of Jilin Province, China(No.20010306-1)the China’s Post-doctoral Science Fund(No.20040350561).
文摘This article focuses on iodine determination by microwave plasma torch atomic emission spectrometry (MPT-AES) coupled with online preconcentration vapor generation method. A new desolvation device, multistrand Nafion dryer, was used as the substitute for condenser desolvation system. Some experimental conditions, such as preconcentration time, acidity of sample solution, rinsing solution acidity and dynamic linear range were investigated and optimized. The new desolvation system eliminates the problem of decreasing emission intensity of I(I) 206.238 nm line with the increase of working time on a conventional condenser desolvation system, thus greatly improving the reproducibility.