There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)...There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice.展开更多
AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of...AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of normal controls.METHODS:This study included 37 patients with unilateral APAC,37 with asymmetric CPACG without prior treatment,and 36 healthy participants.Using swept-source optical coherence tomography(SS-OCT),the macular and peripapillary choroidal thickness and three-dimensional CVI were measured and compared globally and sectorally.Pearson’s correlation analysis and multivariate regression models were used to evaluate choroidal thickness or CVI with related factors.RESULTS:The mean subfoveal CVIs were 0.35±0.10,0.33±0.09,and 0.29±0.04,and the mean subfoveal choroidal thickness were 315.62±52.92,306.22±59.29,and 262.69±45.55μm in the F-APAC,F-CPACG,and normal groups,respectively.All macular sectors showed significantly higher CVIs and choroidal thickness in the F-APAC and F-CPACG eyes than in the normal eyes(P<0.05),while there were no significant differences between the F-APAC and F-CPACG eyes.In the peripapillary region,the mean overall CVIs were 0.21±0.08,0.20±0.08,and 0.19±0.05,and the mean overall choroidal thickness were 180.45±54.18,174.82±50.67,and 176.18±37.94μm in the F-APAC,F-CPACG,and normal groups,respectively.There were no significant differences between any of the two groups in all peripapillary sectors.Younger age,shorter axial length,and the F-APAC or F-CPACG diagnosis were significantly associated with higher subfoveal CVI and thicker subfoveal choroidal thickness(P<0.05).CONCLUSION:The fellow eyes of unilateral APAC or asymmetric CPACG have higher macular CVI and choroidal thickness than those of the normal controls.Neither CVI nor choroidal thickness can distinguish between eyes predisposed to APAC or CPACG.A thicker choroid with a higher vascular volume may play a role in the pathogenesis of primary angle-closure glaucoma.展开更多
In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ...In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications.展开更多
AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone...AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone acetonide(TA).METHODS:A total of 76 eyes newly diagnosed DME were included in this study.They were randomly assigned to receive either aflibercept or a combination of aflibercept and TA.Injections once a month for a total of three injections.Central macular thickness(CMT),number of hyperreflective foci(HRF),height of subretinal fluid(SRF),and area of foveal avascular zone(FAZ)were evaluated using OCT and OCTA at baseline and after each monthly treatment.RESULTS:Both groups showed improvement in best corrected visual acuity(BCVA)and reduction in macular edema after treatment,and the difference in BCVA between the two groups was statistically significant after each treatment(P<0.05).The difference in CMT between the two groups was statistically significant after the first two injections(P<0.01),but not after the third injection(P=0.875).The number of HRF(1mo:7.41±8.25 vs 10.86±7.22,P=0.027;2mo:5.33±6.13 vs 9.12±8.61,P=0.034;3mo:3.58±3.00 vs 6.37±5.97,P=0.007)and height of SRF(1mo:82.39±39.12 vs 105.77±42.26μm,P=0.011;2mo:36.84±10.02 vs 83.59±37.78μm,P<0.01;3mo:11.57±3.29 vs 45.43±12.60μm,P<0.01)in combined group were statistically significant less than aflibercept group after each injection,while the area of FAZ showed no significant change before and after treatment in both groups.CONCLUSION:The combination therapy of aflibercept and TA shows more significant effects on DME eyes with decreased HRF and SRF.However,both aflibercept and combination therapy show no significant change in the area of FAZ.展开更多
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ...Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness.展开更多
AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-thre...AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-three healthy subjects were enrolled.The ONH of both eyes were imaged four times by a swept-source-OCTA using a 3 mm×3 mm scanning protocol.Images of the radial peripapillary capillary were analyzed by a customized Matlab program,and the vessel density,fractal dimension,and vessel diameter index were measured.The repeatability of the four scans was determined by the intraclass correlation coefficient(ICC).The most well-centered optic disc from the four repeated scans was then selected for the interocular correlation and agreement analysis using the Pearson correlation coefficient,ICC and Bland-Altman plots.RESULTS:All swept-source-OCTA ONH parameters exhibited certain repeatability,with ICC>0.760 and coefficient of variation(CoV)≤7.301%.The obvious interocular correlation was observed for papillary vessel density(ICC=0.857),vessel diameter index(ICC=0.857)and fractal dimension(ICC=0.906),while circumpapillary vessel density exhibited moderate interocular correlation(ICC=0.687).Bland-Altman plots revealed an agreement range of-5.26%to 6.21%for circumpapillary vessel density.CONCLUSION:OCTA ONH parameters demonstrate good repeatability in healthy subjects.The interocular correlations of papillary vessel density,fractal dimension and vessel diameter index are high,but the correlation for circumpapillary vessel density is moderate.展开更多
Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,...Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,wide-field OCTA(WF-OCTA)provided more abundant information including that of the peripheral retinal degenerative changes and it can contribute in accurately diagnosing DR.The need for an automatic DR diagnostic system based on WF-OCTA pictures attracts more and more attention due to the large diabetic population and the prevalence of retinopathy cases.In this study,automatic diagnosis of DR using vision transformer was performed using WF-OCTA images(12 mm×12 mm single-scan)centered on the fovea as the dataset.WF-OCTA images were automatically classified into four classes:No DR,mild nonproliferative diabetic retinopathy(NPDR),moderate to severe NPDR,and proliferative diabetic retinopathy(PDR).The proposed method for detecting DR on the test set achieves accuracy of 99.55%,sensitivity of 99.49%,and specificity of 99.57%.The accuracy of the method for DR staging reaches up to 99.20%,which has been proven to be higher than that attained by classical convolutional neural network models.Results show that the automatic diagnosis of DR based on vision transformer and WF-OCTA pictures is more effective for detecting and staging DR.展开更多
AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary ne...AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary nerve fiber layer(pRNFL)and ganglion cell complex(GCC).METHODS:This prospective longitudinal observational study included patients with chiasmal compression due to sellar region mass scheduled for decompressive surgery.Generalized estimating equations were used to compare retinal vessel density and retinal layer thickness preand post-operatively and with healthy controls.Logistic regression models were used to assess the relationship between preoperative GCC,pRNFL,SRCP,and RPC parameters and visual field recovery after surgery.RESULTS:The study included 43 eyes of 24 patients and 48 eyes of 24 healthy controls.Preoperative RPC and SRCP vessel density and pRNFL and GCC thickness were lower than healthy controls and higher than postoperative values.The best predictive GCC and pRNFL models were based on the superior GCC[area under the curve(AUC)=0.866]and the tempo-inferior pRNFL(AUC=0.824),and the best predictive SRCP and RPC models were based on the nasal SRCP(AUC=0.718)and tempo-inferior RPC(AUC=0.825).There was no statistical difference in the predictive value of the superior GCC,tempo-inferior pRNFL,and tempo-inferior RPC(all P>0.05).CONCLUSION:Compression of the optic chiasm by tumors in the saddle area can reduce retinal thickness and blood perfusion.This reduction persists despite the recovery of the visual field after decompression surgery.GCC,pRNFL,and RPC can be used as sensitive predictors of visual field recovery after decompression surgery.展开更多
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be...In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus.展开更多
AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control...AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control subjects were enrolled in the study.One eye of each individual was included and OCT-A scans of optic discs were obtained in a 4.5×4.5 mm^(2) rectangular area.Radial peripapillary capillary(RPC)density,peripapillary retinal nerve fiber layer(pRNFL)thickness,cup volume,rim area,disc area,cup-to-disc(c/d)area ratio,and vertical c/d ratio were obtained automatically using device software.Automated parapapillary choroidal microvasculature(PPCMv)density was calculated using MATLAB software.When the vertical c/d ratio of the optic disc was absent or small cup,it was considered as a crowded disc.RESULTS:The mean signal strength index of OCT-A images was similar between the crowded discs and control eyes(P=0.740).There was no difference in pRNFL between the two groups(P=0.102).There were no differences in RPC density in whole image(P=0.826)and peripapillary region(P=0.923),but inside disc RPC density was higher in crowded optic discs(P=0.003).The PPCMv density in the inner-hemisuperior region was also lower in crowded discs(P=0.026).The pRNFL thickness was positively correlated with peripapillary RPC density(r=0.498,P<0.001).The inside disc RPC density was negatively correlated with c/d area ratio(r=-0.341,P=0.002).CONCLUSION:The higher inside disc RPC density and lower inner-hemisuperior PPCMv density are found in eyes with crowded optic discs.展开更多
AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass...AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass index(BMI)results,the adults enrolled in the cross-sectional study were divided into the normal group(18.50≤BMI<25.00 kg/m^(2)),the overweight group(25.00≤BMI<30.00 kg/m^(2)),and the obesity group(BMI≥30.00 kg/m^(2)).The one-way ANOVA and the Chi-square test were used for comparisons.Pearson’s correlation analysis was used to evaluate the relationships between the measured variables.RESULTS:This research covered the left eyes of 3 groups of 434 age-and sex-matched subjects each:normal,overweight,and obesity.The mean BMI was 22.20±1.67,26.82±1.38,and 32.21±2.35 kg/m^(2) in normal,overweight and obesity groups,respectively.The choroid was significantly thinner in both the overweight and obesity groups compared to the normal group(P<0.05 for all),while the retinal thickness of the three groups did not differ significantly.Pearson’s correlation analysis showed that BMI was significantly negatively correlated with choroidal thickness,but no significant correlation was observed between BMI and retinal thickness.CONCLUSION:Choroidal thickness is decreased in people with overweight or obesity.Research on changes in choroidal thickness contributes to the understanding of the mechanisms of certain ocular disorders in overweight and obese adults.展开更多
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac...AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable.展开更多
AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal cr...AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance.展开更多
AIM:To develop an automated model for subfoveal choroidal thickness(SFCT)detection in optical coherence tomography(OCT)images,addressing manual fovea location and choroidal contour challenges.METHODS:Two procedures we...AIM:To develop an automated model for subfoveal choroidal thickness(SFCT)detection in optical coherence tomography(OCT)images,addressing manual fovea location and choroidal contour challenges.METHODS:Two procedures were proposed:defining the fovea and segmenting the choroid.Fovea localization from B-scan OCT image sequence with three-dimensional reconstruction(LocBscan-3D)predicted fovea location using central foveal depression features,and fovea localization from two-dimensional en-face OCT(LocEN-2D)used a mask region-based convolutional neural network(Mask R-CNN)model for optic disc detection,and determined the fovea location based on optic disc relative position.Choroid segmentation also employed Mask R-CNN.RESULTS:For 53 eyes in 28 healthy subjects,LocBscan-3D’s mean difference between manual and predicted fovea locations was 170.0μm,LocEN-2D yielded 675.9μm.LocEN-2D performed better in non-high myopia group(P=0.02).SFCT measurements from Mask R-CNN aligned with manual values.CONCLUSION:Our models accurately predict SFCT in OCT images.LocBscan-3D excels in precise fovea localization even with high myopia.LocEN-2D shows high detection rates but lower accuracy especially in the high myopia group.Combining both models offers a robust SFCT assessment approach,promising efficiency and accuracy for large-scale studies and clinical use.展开更多
AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of...AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of PD patients examined in the Ophthalmology Department of the General Hospital of Athens,“Georgios Gennimatas”from March 2021 to March 2022 was conducted.Totally 44 patients with PD were included and 18 healthy controls were examined,hence a total of 124 eyes were enrolled in the study.The foveal and parafoveal superficial and deep capillary plexus vascular density(fSCP-VD,fDCP-VD,pSCP-VD,pDCP-CD)and foveal avascular zone(FAZ)were quantified with OCTA.Optical coherence tomography(OCT)was used to measure macular thickness.Our statistical analysis was conducted by using a mixed effect linear regression model.RESULTS:After adjustment for age and gender,the mean parafoveal superficial capillary plexus vascular density(pSCP-VD)and mean parafoveal deep capillary plexus vascular density(pDCP-VD)were significantly decreased in individuals with PD(P<0.001 in both)by-2.35(95%CI-3.3,-1.45)and-7.5(95%CI-10.4,-4.6)respectively.fSCP-VD and fDCP-VD didn’t approach statistical significance.The FAZ area and perimeter were significantly decreased(P<0.001 in both)by-0.1 mm^(2)(95%CI-0.13,-0.07)and-0.49 mm^(2)(95%CI-0.66,-0.32)respectively.Circularity didn’t approach statistical significance.Central retinal thickness(CRT)was significantly decreased in individuals with PD(P<0.001)by-23.1μm(95%CI-30.2,-16)and temporal retinal thickness(TRT)was decreased(P=0.025)by-11μm(95%CI-22,-1.5)while nasal retinal thickness(NRT)only approached statistical significance(P=0.066).CONCLUSION:The mean pSCP-VD,pDCP-VD,CRT and TRT are significantly decreased and FAZ is altered in individuals with PD.These findings can be potentially used as biomarkers for the diagnosis and evaluation of early PD.展开更多
BACKGROUND Retinal microcirculation alterations are early indicators of diabetic microvascular complications.Optical coherence tomography angiography(OCTA)is a noninvasive method to assess these changes.This study ana...BACKGROUND Retinal microcirculation alterations are early indicators of diabetic microvascular complications.Optical coherence tomography angiography(OCTA)is a noninvasive method to assess these changes.This study analyzes changes in retinal microcirculation in prediabetic patients during short-term increases in blood glucose using OCTA.AIM To investigate the changes in retinal microcirculation in prediabetic patients experiencing short-term increases in blood glucose levels using OCTA.METHODS Fifty volunteers were divided into three groups:Group 1[impaired fasting glucose(IFG)or impaired glucose tolerance(IGT)],Group 2(both IFG and IGT),and a control group.Retinal microcirculation parameters,including vessel density(VD),perfusion density(PD),and foveal avascular zone(FAZ)metrics,were measured using OCTA.Correlations between these parameters and blood glucose levels were analyzed in both the fasting and postprandial states.RESULTS One hour after glucose intake,the central VD(P=0.023),central PD(P=0.026),and parafoveal PD(P<0.001)were significantly greater in the control group than in the fasting group.In Group 1,parafoveal PD(P<0.001)and FAZ circularity(P=0.023)also increased one hour after glucose intake.However,no significant changes were observed in the retinal microcirculation parameters of Group 2 before or after glucose intake(P>0.05).Compared with the control group,Group 1 had a larger FAZ area(P=0.032)and perimeter(P=0.018),whereas Group 2 had no significant differences in retinal microcirculation parameters compared with the control group(P>0.05).Compared with Group 1,Group 2 had greater central VD(P=0.013)and PD(P=0.008)and a smaller FAZ area(P=0.012)and perimeter(P=0.010).One hour after glucose intake,Group 1 had a larger FAZ area(P=0.044)and perimeter(P=0.038)than did the control group,whereas Group 2 showed no significant differences in retinal microcirculation parameters compared with the control group(P>0.05).Group 2 had greater central VD(P=0.042)and PD(P=0.022)and a smaller FAZ area(P=0.015)and perimeter(P=0.016)than Group 1.At fasting,central PD was significantly positively correlated with blood glucose levels(P=0.044),whereas no significant correlations were found between blood glucose levels and OCTA parameters one hour after glucose intake.CONCLUSION A short-term increase in blood glucose has a more pronounced effect on retinal microcirculation in prediabetic patients with either IFG or IGT.展开更多
AIM:To explore the latest application of artificial intelligence(AI)in optical coherence tomography(OCT)images,and to analyze the current research status of AI in OCT,and discuss the future research trend.METHODS:On J...AIM:To explore the latest application of artificial intelligence(AI)in optical coherence tomography(OCT)images,and to analyze the current research status of AI in OCT,and discuss the future research trend.METHODS:On June 1,2023,a bibliometric analysis of the Web of Science Core Collection was performed in order to explore the utilization of AI in OCT imagery.Key parameters such as papers,countries/regions,citations,databases,organizations,keywords,journal names,and research hotspots were extracted and then visualized employing the VOSviewer and CiteSpace V bibliometric platforms.RESULTS:Fifty-five nations reported studies on AI biotechnology and its application in analyzing OCT images.The United States was the country with the largest number of published papers.Furthermore,197 institutions worldwide provided published articles,where University of London had more publications than the rest.The reference clusters from the study could be divided into four categories:thickness and eyes,diabetic retinopathy(DR),images and segmentation,and OCT classification.CONCLUSION:The latest hot topics and future directions in this field are identified,and the dynamic evolution of AIbased OCT imaging are outlined.AI-based OCT imaging holds great potential for revolutionizing clinical care.展开更多
AIM:To measure the difference of intraoperative central macular thickness(CMT)before,during,and after membrane peeling and investigate the influence of intraoperative macular stretching on postoperative best corrected...AIM:To measure the difference of intraoperative central macular thickness(CMT)before,during,and after membrane peeling and investigate the influence of intraoperative macular stretching on postoperative best corrected visual acuity(BCVA)outcome and postoperative CMT development.METHODS:A total of 59 eyes of 59 patients who underwent vitreoretinal surgery for epiretinal membrane was analyzed.Videos with intraoperative optical coherence tomography(OCT)were recorded.Difference of intraoperative CMT before,during,and after peeling was measured.Pre-and postoperatively obtained BCVA and spectral-domain OCT images were analyzed.RESULTS:Mean age of the patients was 70±8.13y(range 46-86y).Mean baseline BCVA was 0.49±0.27 log MAR(range 0.1-1.3).Three and six months postoperatively the mean BCVA was 0.36±0.25(P=0.01 vs baseline)and 0.38±0.35(P=0.08 vs baseline)log MAR respectively.Mean stretch of the macula during surgery was 29%from baseline(range 2%-159%).Intraoperative findings of macular stretching did not correlate with visual acuity outcome within 6mo after surgery(r=-0.06,P=0.72).However,extent of macular stretching during surgery significantly correlated with less reduction of CMT at the fovea centralis(r=-0.43,P<0.01)and 1 mm nasal and temporal from the fovea(r=-0.37,P=0.02 and r=-0.50,P<0.01 respectively)3mo postoperatively.CONCLUSION:The extent of retinal stretching during membrane peeling may predict the development of postoperative central retinal thickness,though there is no correlation with visual acuity development within the first 6mo postoperatively.展开更多
AIM:To compare the macular ganglion cell-inner plexiform layer(GCIPL)thickness,retinal nerve fiber layer(RNFL)thickness,optic nerve head(ONH)parameters,and retinal vessel density(VD)measured by spectral-domain optical...AIM:To compare the macular ganglion cell-inner plexiform layer(GCIPL)thickness,retinal nerve fiber layer(RNFL)thickness,optic nerve head(ONH)parameters,and retinal vessel density(VD)measured by spectral-domain optical coherence tomography(SD-OCT)and analyze the correlations between them in the early,moderate,severe primary angle-closure glaucoma(PACG)and normal eyes.METHODS:Totally 70 PACG eyes and 20 normal eyes were recruited for this retrospective analysis.PACG eyes were further separated into early,moderate,or severe PACG eyes using the Enhanced Glaucoma Staging System(GSS2).The GCIPL thickness,RNFL thickness,ONH parameters,and retinal VD were measured by SD-OCT,differences among the groups and correlations within the same group were calculated.RESULTS:The inferior and superotemporal sectors of the GCIPL thickness,rim area of ONH,average and inferior sector of the retinal VD were significantly reduced(all P<0.05)in the early PACG eyes compared to the normal and the optic disc area,cup to disc ratio(C/D),and cup volume were significantly higher(all P<0.05);but the RNFL was not significant changes in early and moderate PACG.In severe group,the GCIPL and RNFL thickness were obvious thinning with retinal VD were decreasing as well as C/D and cup volume increasing than other three groups(all P<0.01).In the early PACG subgroup,there were significant positive correlations between retinal VD and GCIPL thickness(except superonasal and inferonasal sectors,r=0.573 to 0.641,all P<0.05),superior sectors of RNFL thickness(r=0.055,P=0.049).More obvious significant positive correlations were existed in moderate PACG eyes between retinal VD and superior sectors of RNFL thickness(r=0.650,P=0.022),and temporal sectors of RNFL thickness(r=0.740,P=0.006).In the severe PACG eyes,neither GCIPL nor RNFL thickness was associated with retinal VD.CONCLUSION:The ONH damage and retinal VD loss appears earlier than RNFL thickness loss in PACG eyes.As the PACG disease progressed from the early to the moderate stage,the correlations between the retinal VD and RNFL thickness increases.展开更多
AIM:To investigate the aqueous vein in vivo by using enhanced depth imaging optical coherence tomography(EDI-OCT)and optical coherence tomography angiography(OCTA).METHODS:In this cross-sectional comparative study,30 ...AIM:To investigate the aqueous vein in vivo by using enhanced depth imaging optical coherence tomography(EDI-OCT)and optical coherence tomography angiography(OCTA).METHODS:In this cross-sectional comparative study,30 healthy participants were enrolled.Images of the aqueous and conjunctival veins were captured by EDI-OCT and OCTA before and after water loading.The area,height,width,location depth and blood flow of the aqueous vein and conjunctival vein were measured by Image J software.RESULTS:In the static state,the area of the aqueous vein was 8166.7±3272.7μm^(2),which was smaller than that of the conjunctival vein(13690±7457μm^(2),P<0.001).The mean blood flow density of the aqueous vein was 35.3%±12.6%,which was significantly less than that of the conjunctival vein(51.5%±10.6%,P<0.001).After water loading,the area of the aqueous vein decreased significantly from 8725.8±779.4μm^(2)(baseline)to 7005.2±566.2μm^(2)at 45min but rose to 7863.0±703.2μm^(2)at 60min(P=0.032).The blood flow density of the aqueous vein decreased significantly from 41.2%±4.5%(baseline)to 35.4%±3.2%at 30min but returned to 45.6%±3.6%at 60min(P=0.021).CONCLUSION:The structure and blood flow density of the aqueous vein can be effectively evaluated by OCT and OCTA.These may become biological indicators to evaluate aqueous vein changes and aqueous outflow resistance under different interventions in glaucoma patients.展开更多
基金support of the foundations:National Key R&D Program of China,Grant Nos.2022YFC2404201CAS Project for Young Scientists in Basic Research,Grant Nos.YSBR-067+2 种基金The Gusu Innovation and Entrepreneurship Leading Talents in Suzhou City,Grant Nos.ZXL2021425Jiangsu Science and Technology Plan Program,Grant Nos.BK20220263National Key R&D Program of China,Grant Nos.2021YFF0700503.
文摘There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice.
基金Supported by the National Natural Science Foundation of China(No.82101087)Shanghai Clinical Research Key Project(No.SHDC2020CR6029).
文摘AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of normal controls.METHODS:This study included 37 patients with unilateral APAC,37 with asymmetric CPACG without prior treatment,and 36 healthy participants.Using swept-source optical coherence tomography(SS-OCT),the macular and peripapillary choroidal thickness and three-dimensional CVI were measured and compared globally and sectorally.Pearson’s correlation analysis and multivariate regression models were used to evaluate choroidal thickness or CVI with related factors.RESULTS:The mean subfoveal CVIs were 0.35±0.10,0.33±0.09,and 0.29±0.04,and the mean subfoveal choroidal thickness were 315.62±52.92,306.22±59.29,and 262.69±45.55μm in the F-APAC,F-CPACG,and normal groups,respectively.All macular sectors showed significantly higher CVIs and choroidal thickness in the F-APAC and F-CPACG eyes than in the normal eyes(P<0.05),while there were no significant differences between the F-APAC and F-CPACG eyes.In the peripapillary region,the mean overall CVIs were 0.21±0.08,0.20±0.08,and 0.19±0.05,and the mean overall choroidal thickness were 180.45±54.18,174.82±50.67,and 176.18±37.94μm in the F-APAC,F-CPACG,and normal groups,respectively.There were no significant differences between any of the two groups in all peripapillary sectors.Younger age,shorter axial length,and the F-APAC or F-CPACG diagnosis were significantly associated with higher subfoveal CVI and thicker subfoveal choroidal thickness(P<0.05).CONCLUSION:The fellow eyes of unilateral APAC or asymmetric CPACG have higher macular CVI and choroidal thickness than those of the normal controls.Neither CVI nor choroidal thickness can distinguish between eyes predisposed to APAC or CPACG.A thicker choroid with a higher vascular volume may play a role in the pathogenesis of primary angle-closure glaucoma.
基金funding from the National Natural Science Foundation of China(NSFC)under grants 61627827,61705068the Natural Science Foundation of Fujian Province 2021J01813the Fujian Medical University Research Foundation of Talented Scholars XRCZX2021004.
文摘In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications.
基金Supported by the Natural Science Foundation of Guangdong Province,China(No.2022A1515010742)Hunan Provincial Natural Science Foundation of China(No.2023JJ70039)Scientific Research Program of Xiangjiang Philanthropy Foundation.
文摘AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone acetonide(TA).METHODS:A total of 76 eyes newly diagnosed DME were included in this study.They were randomly assigned to receive either aflibercept or a combination of aflibercept and TA.Injections once a month for a total of three injections.Central macular thickness(CMT),number of hyperreflective foci(HRF),height of subretinal fluid(SRF),and area of foveal avascular zone(FAZ)were evaluated using OCT and OCTA at baseline and after each monthly treatment.RESULTS:Both groups showed improvement in best corrected visual acuity(BCVA)and reduction in macular edema after treatment,and the difference in BCVA between the two groups was statistically significant after each treatment(P<0.05).The difference in CMT between the two groups was statistically significant after the first two injections(P<0.01),but not after the third injection(P=0.875).The number of HRF(1mo:7.41±8.25 vs 10.86±7.22,P=0.027;2mo:5.33±6.13 vs 9.12±8.61,P=0.034;3mo:3.58±3.00 vs 6.37±5.97,P=0.007)and height of SRF(1mo:82.39±39.12 vs 105.77±42.26μm,P=0.011;2mo:36.84±10.02 vs 83.59±37.78μm,P<0.01;3mo:11.57±3.29 vs 45.43±12.60μm,P<0.01)in combined group were statistically significant less than aflibercept group after each injection,while the area of FAZ showed no significant change before and after treatment in both groups.CONCLUSION:The combination therapy of aflibercept and TA shows more significant effects on DME eyes with decreased HRF and SRF.However,both aflibercept and combination therapy show no significant change in the area of FAZ.
基金supported by the National Natural Science Foundation of China(62375144 and 61875092)Tianjin Foundation of Natural Science(21JCYBJC00260)Beijing-Tianjin-Hebei Basic Research Cooperation Special Program(19JCZDJC65300).
文摘Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness.
基金Natural Science Foundation of Guangdong Province(No.2018A0303130306)Shantou Science and Technology Program(No.190917085269835,No.200629165261641).
文摘AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-three healthy subjects were enrolled.The ONH of both eyes were imaged four times by a swept-source-OCTA using a 3 mm×3 mm scanning protocol.Images of the radial peripapillary capillary were analyzed by a customized Matlab program,and the vessel density,fractal dimension,and vessel diameter index were measured.The repeatability of the four scans was determined by the intraclass correlation coefficient(ICC).The most well-centered optic disc from the four repeated scans was then selected for the interocular correlation and agreement analysis using the Pearson correlation coefficient,ICC and Bland-Altman plots.RESULTS:All swept-source-OCTA ONH parameters exhibited certain repeatability,with ICC>0.760 and coefficient of variation(CoV)≤7.301%.The obvious interocular correlation was observed for papillary vessel density(ICC=0.857),vessel diameter index(ICC=0.857)and fractal dimension(ICC=0.906),while circumpapillary vessel density exhibited moderate interocular correlation(ICC=0.687).Bland-Altman plots revealed an agreement range of-5.26%to 6.21%for circumpapillary vessel density.CONCLUSION:OCTA ONH parameters demonstrate good repeatability in healthy subjects.The interocular correlations of papillary vessel density,fractal dimension and vessel diameter index are high,but the correlation for circumpapillary vessel density is moderate.
基金supported by the National Natural Science Foundation of China(Grant Nos.62175156,81827807,81770940)Science and Technology Commission of Shanghai Municipality(22S31903000,16DZ0501100)Collaborative Innovation Project of Shanghai Institute of Technology(XTCX2022-27).
文摘Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,wide-field OCTA(WF-OCTA)provided more abundant information including that of the peripheral retinal degenerative changes and it can contribute in accurately diagnosing DR.The need for an automatic DR diagnostic system based on WF-OCTA pictures attracts more and more attention due to the large diabetic population and the prevalence of retinopathy cases.In this study,automatic diagnosis of DR using vision transformer was performed using WF-OCTA images(12 mm×12 mm single-scan)centered on the fovea as the dataset.WF-OCTA images were automatically classified into four classes:No DR,mild nonproliferative diabetic retinopathy(NPDR),moderate to severe NPDR,and proliferative diabetic retinopathy(PDR).The proposed method for detecting DR on the test set achieves accuracy of 99.55%,sensitivity of 99.49%,and specificity of 99.57%.The accuracy of the method for DR staging reaches up to 99.20%,which has been proven to be higher than that attained by classical convolutional neural network models.Results show that the automatic diagnosis of DR based on vision transformer and WF-OCTA pictures is more effective for detecting and staging DR.
文摘AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary nerve fiber layer(pRNFL)and ganglion cell complex(GCC).METHODS:This prospective longitudinal observational study included patients with chiasmal compression due to sellar region mass scheduled for decompressive surgery.Generalized estimating equations were used to compare retinal vessel density and retinal layer thickness preand post-operatively and with healthy controls.Logistic regression models were used to assess the relationship between preoperative GCC,pRNFL,SRCP,and RPC parameters and visual field recovery after surgery.RESULTS:The study included 43 eyes of 24 patients and 48 eyes of 24 healthy controls.Preoperative RPC and SRCP vessel density and pRNFL and GCC thickness were lower than healthy controls and higher than postoperative values.The best predictive GCC and pRNFL models were based on the superior GCC[area under the curve(AUC)=0.866]and the tempo-inferior pRNFL(AUC=0.824),and the best predictive SRCP and RPC models were based on the nasal SRCP(AUC=0.718)and tempo-inferior RPC(AUC=0.825).There was no statistical difference in the predictive value of the superior GCC,tempo-inferior pRNFL,and tempo-inferior RPC(all P>0.05).CONCLUSION:Compression of the optic chiasm by tumors in the saddle area can reduce retinal thickness and blood perfusion.This reduction persists despite the recovery of the visual field after decompression surgery.GCC,pRNFL,and RPC can be used as sensitive predictors of visual field recovery after decompression surgery.
基金supported in part by the National Natural Science Foundation of China under Grants 61975091,61905015,61575108,and 61505034by the Tsinghua Precision Medicine Foundation and“Bio-Brain+X”Advanced Imaging Instrument Development Seed Grant.
文摘In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus.
文摘AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control subjects were enrolled in the study.One eye of each individual was included and OCT-A scans of optic discs were obtained in a 4.5×4.5 mm^(2) rectangular area.Radial peripapillary capillary(RPC)density,peripapillary retinal nerve fiber layer(pRNFL)thickness,cup volume,rim area,disc area,cup-to-disc(c/d)area ratio,and vertical c/d ratio were obtained automatically using device software.Automated parapapillary choroidal microvasculature(PPCMv)density was calculated using MATLAB software.When the vertical c/d ratio of the optic disc was absent or small cup,it was considered as a crowded disc.RESULTS:The mean signal strength index of OCT-A images was similar between the crowded discs and control eyes(P=0.740).There was no difference in pRNFL between the two groups(P=0.102).There were no differences in RPC density in whole image(P=0.826)and peripapillary region(P=0.923),but inside disc RPC density was higher in crowded optic discs(P=0.003).The PPCMv density in the inner-hemisuperior region was also lower in crowded discs(P=0.026).The pRNFL thickness was positively correlated with peripapillary RPC density(r=0.498,P<0.001).The inside disc RPC density was negatively correlated with c/d area ratio(r=-0.341,P=0.002).CONCLUSION:The higher inside disc RPC density and lower inner-hemisuperior PPCMv density are found in eyes with crowded optic discs.
基金Supported by the Science and Technology Commission of Shanghai Municipality(No.20Y11910800).
文摘AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass index(BMI)results,the adults enrolled in the cross-sectional study were divided into the normal group(18.50≤BMI<25.00 kg/m^(2)),the overweight group(25.00≤BMI<30.00 kg/m^(2)),and the obesity group(BMI≥30.00 kg/m^(2)).The one-way ANOVA and the Chi-square test were used for comparisons.Pearson’s correlation analysis was used to evaluate the relationships between the measured variables.RESULTS:This research covered the left eyes of 3 groups of 434 age-and sex-matched subjects each:normal,overweight,and obesity.The mean BMI was 22.20±1.67,26.82±1.38,and 32.21±2.35 kg/m^(2) in normal,overweight and obesity groups,respectively.The choroid was significantly thinner in both the overweight and obesity groups compared to the normal group(P<0.05 for all),while the retinal thickness of the three groups did not differ significantly.Pearson’s correlation analysis showed that BMI was significantly negatively correlated with choroidal thickness,but no significant correlation was observed between BMI and retinal thickness.CONCLUSION:Choroidal thickness is decreased in people with overweight or obesity.Research on changes in choroidal thickness contributes to the understanding of the mechanisms of certain ocular disorders in overweight and obese adults.
基金Supported by Tianjin Key Medical Discipline (Specialty) Construction Project (No.TJYXZDXK-037A)Weifang Science and Technology Bureau Project (No.2020YX065).
文摘AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable.
文摘AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance.
文摘AIM:To develop an automated model for subfoveal choroidal thickness(SFCT)detection in optical coherence tomography(OCT)images,addressing manual fovea location and choroidal contour challenges.METHODS:Two procedures were proposed:defining the fovea and segmenting the choroid.Fovea localization from B-scan OCT image sequence with three-dimensional reconstruction(LocBscan-3D)predicted fovea location using central foveal depression features,and fovea localization from two-dimensional en-face OCT(LocEN-2D)used a mask region-based convolutional neural network(Mask R-CNN)model for optic disc detection,and determined the fovea location based on optic disc relative position.Choroid segmentation also employed Mask R-CNN.RESULTS:For 53 eyes in 28 healthy subjects,LocBscan-3D’s mean difference between manual and predicted fovea locations was 170.0μm,LocEN-2D yielded 675.9μm.LocEN-2D performed better in non-high myopia group(P=0.02).SFCT measurements from Mask R-CNN aligned with manual values.CONCLUSION:Our models accurately predict SFCT in OCT images.LocBscan-3D excels in precise fovea localization even with high myopia.LocEN-2D shows high detection rates but lower accuracy especially in the high myopia group.Combining both models offers a robust SFCT assessment approach,promising efficiency and accuracy for large-scale studies and clinical use.
文摘AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of PD patients examined in the Ophthalmology Department of the General Hospital of Athens,“Georgios Gennimatas”from March 2021 to March 2022 was conducted.Totally 44 patients with PD were included and 18 healthy controls were examined,hence a total of 124 eyes were enrolled in the study.The foveal and parafoveal superficial and deep capillary plexus vascular density(fSCP-VD,fDCP-VD,pSCP-VD,pDCP-CD)and foveal avascular zone(FAZ)were quantified with OCTA.Optical coherence tomography(OCT)was used to measure macular thickness.Our statistical analysis was conducted by using a mixed effect linear regression model.RESULTS:After adjustment for age and gender,the mean parafoveal superficial capillary plexus vascular density(pSCP-VD)and mean parafoveal deep capillary plexus vascular density(pDCP-VD)were significantly decreased in individuals with PD(P<0.001 in both)by-2.35(95%CI-3.3,-1.45)and-7.5(95%CI-10.4,-4.6)respectively.fSCP-VD and fDCP-VD didn’t approach statistical significance.The FAZ area and perimeter were significantly decreased(P<0.001 in both)by-0.1 mm^(2)(95%CI-0.13,-0.07)and-0.49 mm^(2)(95%CI-0.66,-0.32)respectively.Circularity didn’t approach statistical significance.Central retinal thickness(CRT)was significantly decreased in individuals with PD(P<0.001)by-23.1μm(95%CI-30.2,-16)and temporal retinal thickness(TRT)was decreased(P=0.025)by-11μm(95%CI-22,-1.5)while nasal retinal thickness(NRT)only approached statistical significance(P=0.066).CONCLUSION:The mean pSCP-VD,pDCP-VD,CRT and TRT are significantly decreased and FAZ is altered in individuals with PD.These findings can be potentially used as biomarkers for the diagnosis and evaluation of early PD.
基金Supported by The Project Foundation of Chongqing Science and Technology Commission of China,No.cstc2018jcyjAX0798.
文摘BACKGROUND Retinal microcirculation alterations are early indicators of diabetic microvascular complications.Optical coherence tomography angiography(OCTA)is a noninvasive method to assess these changes.This study analyzes changes in retinal microcirculation in prediabetic patients during short-term increases in blood glucose using OCTA.AIM To investigate the changes in retinal microcirculation in prediabetic patients experiencing short-term increases in blood glucose levels using OCTA.METHODS Fifty volunteers were divided into three groups:Group 1[impaired fasting glucose(IFG)or impaired glucose tolerance(IGT)],Group 2(both IFG and IGT),and a control group.Retinal microcirculation parameters,including vessel density(VD),perfusion density(PD),and foveal avascular zone(FAZ)metrics,were measured using OCTA.Correlations between these parameters and blood glucose levels were analyzed in both the fasting and postprandial states.RESULTS One hour after glucose intake,the central VD(P=0.023),central PD(P=0.026),and parafoveal PD(P<0.001)were significantly greater in the control group than in the fasting group.In Group 1,parafoveal PD(P<0.001)and FAZ circularity(P=0.023)also increased one hour after glucose intake.However,no significant changes were observed in the retinal microcirculation parameters of Group 2 before or after glucose intake(P>0.05).Compared with the control group,Group 1 had a larger FAZ area(P=0.032)and perimeter(P=0.018),whereas Group 2 had no significant differences in retinal microcirculation parameters compared with the control group(P>0.05).Compared with Group 1,Group 2 had greater central VD(P=0.013)and PD(P=0.008)and a smaller FAZ area(P=0.012)and perimeter(P=0.010).One hour after glucose intake,Group 1 had a larger FAZ area(P=0.044)and perimeter(P=0.038)than did the control group,whereas Group 2 showed no significant differences in retinal microcirculation parameters compared with the control group(P>0.05).Group 2 had greater central VD(P=0.042)and PD(P=0.022)and a smaller FAZ area(P=0.015)and perimeter(P=0.016)than Group 1.At fasting,central PD was significantly positively correlated with blood glucose levels(P=0.044),whereas no significant correlations were found between blood glucose levels and OCTA parameters one hour after glucose intake.CONCLUSION A short-term increase in blood glucose has a more pronounced effect on retinal microcirculation in prediabetic patients with either IFG or IGT.
基金Supported by Shenzhen Fund for Guangdong Provincial High-level Clinical Key Specialties(No.SZGSP014)Sanming Project of Medicine in Shenzhen(No.SZSM202011015)Shenzhen Science and Technology Planning Project(No.KCXFZ20211020163813019).
文摘AIM:To explore the latest application of artificial intelligence(AI)in optical coherence tomography(OCT)images,and to analyze the current research status of AI in OCT,and discuss the future research trend.METHODS:On June 1,2023,a bibliometric analysis of the Web of Science Core Collection was performed in order to explore the utilization of AI in OCT imagery.Key parameters such as papers,countries/regions,citations,databases,organizations,keywords,journal names,and research hotspots were extracted and then visualized employing the VOSviewer and CiteSpace V bibliometric platforms.RESULTS:Fifty-five nations reported studies on AI biotechnology and its application in analyzing OCT images.The United States was the country with the largest number of published papers.Furthermore,197 institutions worldwide provided published articles,where University of London had more publications than the rest.The reference clusters from the study could be divided into four categories:thickness and eyes,diabetic retinopathy(DR),images and segmentation,and OCT classification.CONCLUSION:The latest hot topics and future directions in this field are identified,and the dynamic evolution of AIbased OCT imaging are outlined.AI-based OCT imaging holds great potential for revolutionizing clinical care.
文摘AIM:To measure the difference of intraoperative central macular thickness(CMT)before,during,and after membrane peeling and investigate the influence of intraoperative macular stretching on postoperative best corrected visual acuity(BCVA)outcome and postoperative CMT development.METHODS:A total of 59 eyes of 59 patients who underwent vitreoretinal surgery for epiretinal membrane was analyzed.Videos with intraoperative optical coherence tomography(OCT)were recorded.Difference of intraoperative CMT before,during,and after peeling was measured.Pre-and postoperatively obtained BCVA and spectral-domain OCT images were analyzed.RESULTS:Mean age of the patients was 70±8.13y(range 46-86y).Mean baseline BCVA was 0.49±0.27 log MAR(range 0.1-1.3).Three and six months postoperatively the mean BCVA was 0.36±0.25(P=0.01 vs baseline)and 0.38±0.35(P=0.08 vs baseline)log MAR respectively.Mean stretch of the macula during surgery was 29%from baseline(range 2%-159%).Intraoperative findings of macular stretching did not correlate with visual acuity outcome within 6mo after surgery(r=-0.06,P=0.72).However,extent of macular stretching during surgery significantly correlated with less reduction of CMT at the fovea centralis(r=-0.43,P<0.01)and 1 mm nasal and temporal from the fovea(r=-0.37,P=0.02 and r=-0.50,P<0.01 respectively)3mo postoperatively.CONCLUSION:The extent of retinal stretching during membrane peeling may predict the development of postoperative central retinal thickness,though there is no correlation with visual acuity development within the first 6mo postoperatively.
基金Supported by the Youth National Natural Science Foundation of China(No.81700800,No.81800800)the Natural Science Foundation of Shandong Province(No.ZR2017MH008)Taishan Scholar Project of Shandong Province(No.tsqn201812151)。
文摘AIM:To compare the macular ganglion cell-inner plexiform layer(GCIPL)thickness,retinal nerve fiber layer(RNFL)thickness,optic nerve head(ONH)parameters,and retinal vessel density(VD)measured by spectral-domain optical coherence tomography(SD-OCT)and analyze the correlations between them in the early,moderate,severe primary angle-closure glaucoma(PACG)and normal eyes.METHODS:Totally 70 PACG eyes and 20 normal eyes were recruited for this retrospective analysis.PACG eyes were further separated into early,moderate,or severe PACG eyes using the Enhanced Glaucoma Staging System(GSS2).The GCIPL thickness,RNFL thickness,ONH parameters,and retinal VD were measured by SD-OCT,differences among the groups and correlations within the same group were calculated.RESULTS:The inferior and superotemporal sectors of the GCIPL thickness,rim area of ONH,average and inferior sector of the retinal VD were significantly reduced(all P<0.05)in the early PACG eyes compared to the normal and the optic disc area,cup to disc ratio(C/D),and cup volume were significantly higher(all P<0.05);but the RNFL was not significant changes in early and moderate PACG.In severe group,the GCIPL and RNFL thickness were obvious thinning with retinal VD were decreasing as well as C/D and cup volume increasing than other three groups(all P<0.01).In the early PACG subgroup,there were significant positive correlations between retinal VD and GCIPL thickness(except superonasal and inferonasal sectors,r=0.573 to 0.641,all P<0.05),superior sectors of RNFL thickness(r=0.055,P=0.049).More obvious significant positive correlations were existed in moderate PACG eyes between retinal VD and superior sectors of RNFL thickness(r=0.650,P=0.022),and temporal sectors of RNFL thickness(r=0.740,P=0.006).In the severe PACG eyes,neither GCIPL nor RNFL thickness was associated with retinal VD.CONCLUSION:The ONH damage and retinal VD loss appears earlier than RNFL thickness loss in PACG eyes.As the PACG disease progressed from the early to the moderate stage,the correlations between the retinal VD and RNFL thickness increases.
文摘AIM:To investigate the aqueous vein in vivo by using enhanced depth imaging optical coherence tomography(EDI-OCT)and optical coherence tomography angiography(OCTA).METHODS:In this cross-sectional comparative study,30 healthy participants were enrolled.Images of the aqueous and conjunctival veins were captured by EDI-OCT and OCTA before and after water loading.The area,height,width,location depth and blood flow of the aqueous vein and conjunctival vein were measured by Image J software.RESULTS:In the static state,the area of the aqueous vein was 8166.7±3272.7μm^(2),which was smaller than that of the conjunctival vein(13690±7457μm^(2),P<0.001).The mean blood flow density of the aqueous vein was 35.3%±12.6%,which was significantly less than that of the conjunctival vein(51.5%±10.6%,P<0.001).After water loading,the area of the aqueous vein decreased significantly from 8725.8±779.4μm^(2)(baseline)to 7005.2±566.2μm^(2)at 45min but rose to 7863.0±703.2μm^(2)at 60min(P=0.032).The blood flow density of the aqueous vein decreased significantly from 41.2%±4.5%(baseline)to 35.4%±3.2%at 30min but returned to 45.6%±3.6%at 60min(P=0.021).CONCLUSION:The structure and blood flow density of the aqueous vein can be effectively evaluated by OCT and OCTA.These may become biological indicators to evaluate aqueous vein changes and aqueous outflow resistance under different interventions in glaucoma patients.