The surface-enhanced Raman scattering(SERS) optical fiber probes were successfully prepared by self-assembling on polyelectrolyte multilayers. Gold nanorods(Au NRs) were used as SERS enhancement material to give excel...The surface-enhanced Raman scattering(SERS) optical fiber probes were successfully prepared by self-assembling on polyelectrolyte multilayers. Gold nanorods(Au NRs) were used as SERS enhancement material to give excellent biological affinity and stability to the SERS optical fiber probes. Au NRs were synthesized by seed growth method. The synergistic effect between AgNO_(3) and surfactant was investigated, and the highest yield was found when AgNO_(3) was 500 uL. Meanwhile, different SERS optical fiber probes were obtained by selecting silane coupling agent, polyelectrolyte multilayer and graphene oxide(GO) to treat quartz fiber. It was found that the SERS optical fiber probes obtained by the self-assembled on polyelectrolyte multilayers method performed better than those by other methods. In addition, Mapping was combined with finite element simulation to analyze the electromagnetic field distribution at the fiber end face.The electromagnetic field distribution of Au NRs was investigated, the difference of electromagnetic field intensity around the Au NRs with different arrangements was compared, the strongest signal was obtained when the Au NRs were head-to-head. Finally, sensitivity of the optimized SERS optical fiber probes could reach 10^(-9)mol/L, with excellent stability and repeatability.展开更多
We demonstrated a chemical process in the fabrication of a SERS fiber probe with an ultrahigh sensitivity.The synthesis was carried out by preparing Au@Ag core-shell nanorods (Au@Ag-NRs) selfassembled on polyelectroly...We demonstrated a chemical process in the fabrication of a SERS fiber probe with an ultrahigh sensitivity.The synthesis was carried out by preparing Au@Ag core-shell nanorods (Au@Ag-NRs) selfassembled on polyelectrolyte (PE) multilayers,for which Au@Ag-NRs were controlled by adjusting the silver layer thickness.The effect of silver layer thickness of Au@Ag-NRs on the SERS performance of the fiber probe was investigated.The SERS fiber probe shows the best performance when the silver layer thickness is controlled at 8.57 nm.Under the condition of optimizing silver layer thickness,the fiber probe exhibits ultra-high sensitivity (i e,10^(-10) M crystalline violet,CV),good reproducibility (i e,RSD of 3.5%) and stability.Besides,electromagnetic field distribution of the SERS fiber probe was also investigated.The strongest enhancement is found within the core of fiber,whereas a weakened electromagnetic field exists in the fiber cladding layer.The SERS fiber probe can be a good candidate in ultra-trace detection for biomedical and environmental areas.展开更多
Bubble plumes are important during the process of air-sea exchange,and optical-fiber phase detection is a suitable way to observe bubble plumes entrained by breaking waves.This paper designs a new optical-fiber probe(...Bubble plumes are important during the process of air-sea exchange,and optical-fiber phase detection is a suitable way to observe bubble plumes entrained by breaking waves.This paper designs a new optical-fiber probe(OFP)made of sapphire to overcome the limitations of existing materials(e.g.,high brittleness,poor corrosion resistance,and narrow bandwidth)and thereby enhance the detection performance of the OFP by improving its structure.Based on total internal reflection and light refraction,a simulation model of the probe is established in the Zemax optical design software to optimize the probe tip and matching mode of the two probe tips.The results show that the optimum OFP tip is a conical sapphire one with a cone angle of 35°.Tests are then conducted on a bespoke OFP sensor,the results of which are consistent with those predicted theoretically.The simulation results lay the foundation for the integrated design of OFP sensors and the optimization of their internal optics.The findings could also be applied to OFPs with multiple tips.展开更多
We present a design, construction and characterization of different variations of GRIN and ball fiber lenses, which were recently proposed for ultra-small biomedical imaging probes. Those fiber lens modules are made o...We present a design, construction and characterization of different variations of GRIN and ball fiber lenses, which were recently proposed for ultra-small biomedical imaging probes. Those fiber lens modules are made of a single mode fiber and a GRIN or ball fiber lens with or without a fiber spacer between them. The lens diameters are smaller than 0.3 mm. We discuss design methods, fabrication techniques, and measuring performance of the fiber lenses. The experimental results are compared to their modeling results. The fabrication of a high quality beam director for both lens types is presented as well. These fiber integrated beam directors could be added on the tips of the fiber lenses for side-view probes. A needle probe made by these fiber lenses is demonstrated as a sample of the ultra-small probe for biomedical imaging application. In vivo human finger images acquired by a swept source optical coherence tomography using the fiber lenses with different beam profiles were shown, which indicates the important impact of展开更多
Transmission properties of tapered fiber including right cone fiber and bend optical fiber are discussed.The transmission efficiency of the tapered fiber is measured.The curve of transmission efficiency versus taper c...Transmission properties of tapered fiber including right cone fiber and bend optical fiber are discussed.The transmission efficiency of the tapered fiber is measured.The curve of transmission efficiency versus taper cone angle is given.By the scalar wave equation and Gaussian approximation,transmission properties of the two kinds of tapered fibers are analyzed,the power losses caused by taper cone angle and by the bending are also calculated.From the experiments and theoretical analysis,it could come to a conclusion that the wider the taper cone angle is,the higher the transmission efficiency will be.展开更多
A new optical fiber fluoroptic thermometer based on the temperature—fluoroptic characteristic of fluoroptic materials is presented.The ratio technique of intensities of fluorescent emission lines of certain rare eart...A new optical fiber fluoroptic thermometer based on the temperature—fluoroptic characteristic of fluoroptic materials is presented.The ratio technique of intensities of fluorescent emission lines of certain rare earth phosphors is used,making the measurement of temperatures of the system to 0.5 ℃ precision. The characteristics of thermometer are discussed and the experiment results of temperature are given.展开更多
粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.12...粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.125 g TNT当量的微型炸药球作为爆炸源,进行填实爆炸产生应力波,通过采集光纤探针端面的运动信息,基于短时傅里叶变换的时频分析方法,解调出端面运动速度,进而反推出粒子速度。实验结果表明:不同光纤镀膜探针测得的速度分别为22.648 m/s、23.505 m/s,将反推的粒子速度与传统的圆环型电磁粒子速度计方法获取到的数据进行对比,两者的相对偏差低于5.00%,验证了光纤镀膜探针测量固体介质中应力波粒子速度的可行性。展开更多
An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical c...An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical coherence tomography (FDOCT). Simulation results are shown to gain the effect of the distance between the mieroball lens and the bare fiber to the focusing plane and beam width. The freedom of modifying the working distance and lateral resolution is shown. This is achieved by changing the gap distance between the single-mode fiber and the microball lens within the packaged surgical needle catheter without using an additional beam expander having a fixed length. The probe successfully acquired crosssectional images of ocular tissues from an animal sample with the proposed miniaturized imaging probe.展开更多
We report on the optical trapping and orientation of Escherichia coli(E.coli) cells using two tapered fiber probes.With a laser beam at 980 nm wavelength launched into probe I, an E. coli chain consisting of three cel...We report on the optical trapping and orientation of Escherichia coli(E.coli) cells using two tapered fiber probes.With a laser beam at 980 nm wavelength launched into probe I, an E. coli chain consisting of three cells was formed at the tip of probe I. After launching a beam at 980 nm into probe II, the E.coli at the end of the chain was trapped and oriented via the optical torques yielded by two probes. The orientation of the E. coli was controlled by adjusting the laser power of probe II. Experimental results were interpreted by theoretical analysis and numericalsimulations.展开更多
The paper presents a method of measuring void fraction of steam generator by using optical fiber probes.Comparison is made between void fraction in a vertically upward tube by using optical fiber probes and the void f...The paper presents a method of measuring void fraction of steam generator by using optical fiber probes.Comparison is made between void fraction in a vertically upward tube by using optical fiber probes and the void fraction by quick-close valve.A new method of determining threshold is developed for signal processing from a synchronous measurement procedure.An experimental equation by which average void fraction can be obtained though measuring void fraction at axial center of tube.On-line measuring void fraction of steam generator with vertical tube can be achieved by using optical fiber probes.展开更多
基金Funded by National Natural Science Foundation of China (Nos.51372179, 51772224)the Open Projects Foundation of Yangtze Optical Fiber and Cable Joint Stock Limited Company (YOFC)(No.SKLD1705)。
文摘The surface-enhanced Raman scattering(SERS) optical fiber probes were successfully prepared by self-assembling on polyelectrolyte multilayers. Gold nanorods(Au NRs) were used as SERS enhancement material to give excellent biological affinity and stability to the SERS optical fiber probes. Au NRs were synthesized by seed growth method. The synergistic effect between AgNO_(3) and surfactant was investigated, and the highest yield was found when AgNO_(3) was 500 uL. Meanwhile, different SERS optical fiber probes were obtained by selecting silane coupling agent, polyelectrolyte multilayer and graphene oxide(GO) to treat quartz fiber. It was found that the SERS optical fiber probes obtained by the self-assembled on polyelectrolyte multilayers method performed better than those by other methods. In addition, Mapping was combined with finite element simulation to analyze the electromagnetic field distribution at the fiber end face.The electromagnetic field distribution of Au NRs was investigated, the difference of electromagnetic field intensity around the Au NRs with different arrangements was compared, the strongest signal was obtained when the Au NRs were head-to-head. Finally, sensitivity of the optimized SERS optical fiber probes could reach 10^(-9)mol/L, with excellent stability and repeatability.
基金Funded by National Natural Science Foundation of China (Nos.51372179, 51772224)the Open Projects Foundation of Yangtze Optical Fiber and Cable Joint Stock Limited Company (YOFC)(No.SKLD1705)。
文摘We demonstrated a chemical process in the fabrication of a SERS fiber probe with an ultrahigh sensitivity.The synthesis was carried out by preparing Au@Ag core-shell nanorods (Au@Ag-NRs) selfassembled on polyelectrolyte (PE) multilayers,for which Au@Ag-NRs were controlled by adjusting the silver layer thickness.The effect of silver layer thickness of Au@Ag-NRs on the SERS performance of the fiber probe was investigated.The SERS fiber probe shows the best performance when the silver layer thickness is controlled at 8.57 nm.Under the condition of optimizing silver layer thickness,the fiber probe exhibits ultra-high sensitivity (i e,10^(-10) M crystalline violet,CV),good reproducibility (i e,RSD of 3.5%) and stability.Besides,electromagnetic field distribution of the SERS fiber probe was also investigated.The strongest enhancement is found within the core of fiber,whereas a weakened electromagnetic field exists in the fiber cladding layer.The SERS fiber probe can be a good candidate in ultra-trace detection for biomedical and environmental areas.
文摘Bubble plumes are important during the process of air-sea exchange,and optical-fiber phase detection is a suitable way to observe bubble plumes entrained by breaking waves.This paper designs a new optical-fiber probe(OFP)made of sapphire to overcome the limitations of existing materials(e.g.,high brittleness,poor corrosion resistance,and narrow bandwidth)and thereby enhance the detection performance of the OFP by improving its structure.Based on total internal reflection and light refraction,a simulation model of the probe is established in the Zemax optical design software to optimize the probe tip and matching mode of the two probe tips.The results show that the optimum OFP tip is a conical sapphire one with a cone angle of 35°.Tests are then conducted on a bespoke OFP sensor,the results of which are consistent with those predicted theoretically.The simulation results lay the foundation for the integrated design of OFP sensors and the optimization of their internal optics.The findings could also be applied to OFPs with multiple tips.
文摘We present a design, construction and characterization of different variations of GRIN and ball fiber lenses, which were recently proposed for ultra-small biomedical imaging probes. Those fiber lens modules are made of a single mode fiber and a GRIN or ball fiber lens with or without a fiber spacer between them. The lens diameters are smaller than 0.3 mm. We discuss design methods, fabrication techniques, and measuring performance of the fiber lenses. The experimental results are compared to their modeling results. The fabrication of a high quality beam director for both lens types is presented as well. These fiber integrated beam directors could be added on the tips of the fiber lenses for side-view probes. A needle probe made by these fiber lenses is demonstrated as a sample of the ultra-small probe for biomedical imaging application. In vivo human finger images acquired by a swept source optical coherence tomography using the fiber lenses with different beam profiles were shown, which indicates the important impact of
文摘Transmission properties of tapered fiber including right cone fiber and bend optical fiber are discussed.The transmission efficiency of the tapered fiber is measured.The curve of transmission efficiency versus taper cone angle is given.By the scalar wave equation and Gaussian approximation,transmission properties of the two kinds of tapered fibers are analyzed,the power losses caused by taper cone angle and by the bending are also calculated.From the experiments and theoretical analysis,it could come to a conclusion that the wider the taper cone angle is,the higher the transmission efficiency will be.
文摘A new optical fiber fluoroptic thermometer based on the temperature—fluoroptic characteristic of fluoroptic materials is presented.The ratio technique of intensities of fluorescent emission lines of certain rare earth phosphors is used,making the measurement of temperatures of the system to 0.5 ℃ precision. The characteristics of thermometer are discussed and the experiment results of temperature are given.
文摘粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.125 g TNT当量的微型炸药球作为爆炸源,进行填实爆炸产生应力波,通过采集光纤探针端面的运动信息,基于短时傅里叶变换的时频分析方法,解调出端面运动速度,进而反推出粒子速度。实验结果表明:不同光纤镀膜探针测得的速度分别为22.648 m/s、23.505 m/s,将反推的粒子速度与传统的圆环型电磁粒子速度计方法获取到的数据进行对比,两者的相对偏差低于5.00%,验证了光纤镀膜探针测量固体介质中应力波粒子速度的可行性。
基金supported by the World Class University Program funded by the Ministry of Education, Science, and Technology through the National Research Foundation of Korea (No. R31-10008)supported in part by NIH (No. BRP 1R01 EB 007969- 01)
文摘An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical coherence tomography (FDOCT). Simulation results are shown to gain the effect of the distance between the mieroball lens and the bare fiber to the focusing plane and beam width. The freedom of modifying the working distance and lateral resolution is shown. This is achieved by changing the gap distance between the single-mode fiber and the microball lens within the packaged surgical needle catheter without using an additional beam expander having a fixed length. The probe successfully acquired crosssectional images of ocular tissues from an animal sample with the proposed miniaturized imaging probe.
基金supported by the Program for Changjiang Scholars and Innovative Research Team in University (IRT13042)the National Natural Science Foundation of China (No. 61205165)
文摘We report on the optical trapping and orientation of Escherichia coli(E.coli) cells using two tapered fiber probes.With a laser beam at 980 nm wavelength launched into probe I, an E. coli chain consisting of three cells was formed at the tip of probe I. After launching a beam at 980 nm into probe II, the E.coli at the end of the chain was trapped and oriented via the optical torques yielded by two probes. The orientation of the E. coli was controlled by adjusting the laser power of probe II. Experimental results were interpreted by theoretical analysis and numericalsimulations.
文摘The paper presents a method of measuring void fraction of steam generator by using optical fiber probes.Comparison is made between void fraction in a vertically upward tube by using optical fiber probes and the void fraction by quick-close valve.A new method of determining threshold is developed for signal processing from a synchronous measurement procedure.An experimental equation by which average void fraction can be obtained though measuring void fraction at axial center of tube.On-line measuring void fraction of steam generator with vertical tube can be achieved by using optical fiber probes.