期刊文献+
共找到233,817篇文章
< 1 2 250 >
每页显示 20 50 100
Repeatability,interocular correlation and agreement of optic nerve head vessel density in healthy eyes:a sweptsource optical coherence tomographic angiography study
1
作者 Dan-Qi Fang Da-Wei Yang +2 位作者 Xiao-Ting Mai Carol Y Cheung Hao-Yu Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期896-903,共8页
AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-thre... AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-three healthy subjects were enrolled.The ONH of both eyes were imaged four times by a swept-source-OCTA using a 3 mm×3 mm scanning protocol.Images of the radial peripapillary capillary were analyzed by a customized Matlab program,and the vessel density,fractal dimension,and vessel diameter index were measured.The repeatability of the four scans was determined by the intraclass correlation coefficient(ICC).The most well-centered optic disc from the four repeated scans was then selected for the interocular correlation and agreement analysis using the Pearson correlation coefficient,ICC and Bland-Altman plots.RESULTS:All swept-source-OCTA ONH parameters exhibited certain repeatability,with ICC>0.760 and coefficient of variation(CoV)≤7.301%.The obvious interocular correlation was observed for papillary vessel density(ICC=0.857),vessel diameter index(ICC=0.857)and fractal dimension(ICC=0.906),while circumpapillary vessel density exhibited moderate interocular correlation(ICC=0.687).Bland-Altman plots revealed an agreement range of-5.26%to 6.21%for circumpapillary vessel density.CONCLUSION:OCTA ONH parameters demonstrate good repeatability in healthy subjects.The interocular correlations of papillary vessel density,fractal dimension and vessel diameter index are high,but the correlation for circumpapillary vessel density is moderate. 展开更多
关键词 interocular correlation REPEATABILITY optic nerve head optical coherence tomography angiography vessel density
下载PDF
Study the Structural, Electronic, Optical Properties of CZTS Compound after Doping Ba at Zn Site and Si at Sn Site Using Density Functional Theory (DFT)
2
作者 Fatema Najrin Rabeya Bakar Sarna +4 位作者 Sayedul Hasan Shariful Islam Budrun Neher Md. Mahbubur Rahman Bhuiyan Farid Ahmed 《Materials Sciences and Applications》 2024年第9期305-319,共15页
The structural, electronic, and optical properties of Cu2Zn1−xBaxSn1−ySiyS4 compounds have been calculated using GGA-PBE function within the framework of Density Functional Theory (DFT). In the present work, lattice p... The structural, electronic, and optical properties of Cu2Zn1−xBaxSn1−ySiyS4 compounds have been calculated using GGA-PBE function within the framework of Density Functional Theory (DFT). In the present work, lattice parameters remained the same, that is tetragonal crystal structure for 0% and 100% doping concentration. The electronic band gap of Cu2Zn1−xBaxSn1−ySiyS4 compounds has been gradually increased for continuous increment of doping concentration where the highest electronic band gap is 1.117 eV for Cu2BaSiS4 structure. Moreover, the band gap changes from direct to indirect band gap with the increase of doping concentration in the parent compound. The absorption coefficient has been found to be high (> 104 cm−1) in UV-region for all the doping concentration which makes the studied compound as a potential candidate of absorber layer in the UV detector. The theoretical study of the effect of double doping in the CZTS compound is very interesting for improving the quality of it and it would be a reference for the theoretical and experimental researchers. 展开更多
关键词 Photovoltaics Absorber Layer density Functional Theory (DFT) Band Gap Solar Cell
下载PDF
Evaluation of optic nerve head vessels density changes after phacoemulsification cataract surgery using optical coherence tomography angiography 被引量:1
3
作者 Ze-Hui Zhu Yin-Ying Zhao +4 位作者 Rui Zou Han Zou Jia-Yan Fang Ping-Jun Chang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第6期884-890,共7页
·AIM:To evaluate optic nerve head(ONH)vessel density(VD)changes after cataract surgery using optical coherence tomography angiography(OCTA).·METHODS:This was a prospective observational study.Thirty-four eye... ·AIM:To evaluate optic nerve head(ONH)vessel density(VD)changes after cataract surgery using optical coherence tomography angiography(OCTA).·METHODS:This was a prospective observational study.Thirty-four eyes with mild/moderate cataracts were included.ONH scans were obtained before and 3mo after cataract surgery using OCTA.Radial peripapillary capillary(RPC)density,all VD,large VD and retinal nerve fiber layer thickness(RNFLT)in total disc,inside disc,and different peripapillary sectors were assessed and analyzed.Image quality score(QS),fundus photography grading and bestcorrected visual acuity(BCVA)were also collected,and correlation analyses were performed between VD change and these parameters.·RESULTS:Compared with baseline,both RPC and all VD increased in inside disc area 3mo postoperatively(from 47.5%±5.3%to 50.2%±3.7%,and from 57.87%±4.30%to 60.47%±3.10%,all P<0.001),but no differences were observed in peripapillary area.However,large VD increased from 5.63%±0.77%to 6.47%±0.72%in peripapillary ONH region(P<0.001).RPC decreased in inferior and superior peripapillary ONH parts(P=0.019,<0.001 respectively).There were obvious negative correlations between RPC change and large VD change in inside disc,superior-hemi,and inferior-hemi(r=-0.419,-0.370,and-0.439,P=0.017,0.044,and 0.015,respectively).No correlations were found between VD change and other parameters including QS change,fundus photography grading,postoperative BCVA,and postoperative peripapillary RNFLT.·CONCLUSION:RPC density and all VD in the inside disc ONH region increase 3mo after surgery in patients with mild to moderate cataract.No obvious VD changes are found in peripapillary area postoperatively. 展开更多
关键词 PHACOEMULSIFICATION CATARACT optical coherence tomography angiography vessel density optic nerve head
下载PDF
Local density of optical states calculated by the mode spectrum in stratified media
4
作者 傅廷 陈静瑄 +5 位作者 王学友 戴迎秋 周旭彦 王宇飞 王明金 郑婉华 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期135-141,共7页
The local density of optical states(LDOS)is an important physical concept,which can characterize the spontaneous emission of microcavities.In order to calculate the LDOS,the relationship between the mode spectrum and ... The local density of optical states(LDOS)is an important physical concept,which can characterize the spontaneous emission of microcavities.In order to calculate the LDOS,the relationship between the mode spectrum and the LDOS is established.Then,based on the transfer matrix method and the effective resonator model,the leaky loss of the leaky mode and the mode spectrum in the one-dimensional photonic bandgap crystal waveguide are calculated,results of which indicate that the mode spectrum can characterize the leaky loss of the leaky mode.At last,the density of optical states(DOS),and the LDOS in each layer are calculated.The partial DOS and the partial LDOS in the quantum well,related to the fundamental leaky mode,can be used to find out the optimal location of the quantum well in the defect layer to couple more useful photons into the lasing mode for lasers. 展开更多
关键词 local density of optical states mode spectrum transfer matrix method
下载PDF
Changes of retinal vessel density in low to moderate myopic eyes with orthokeratology evaluated by optical coherence tomography angiography
5
作者 Jia-Hui Shi Yi-Ping Zhao +4 位作者 Gang Liu Xin-Yi Huang Li-Li Lang Wan-Cheng Jia Ji-Li Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第9期1512-1520,共9页
AIM:To explore the effect of orthokeratology(OK)fitting on retinal vessel density in low to moderate myopia adolescents by using optical coherence tomography angiography.METHODS:Children aged 10 to 14y with a cyclople... AIM:To explore the effect of orthokeratology(OK)fitting on retinal vessel density in low to moderate myopia adolescents by using optical coherence tomography angiography.METHODS:Children aged 10 to 14y with a cycloplegic spherical equivalent refraction of−0.50 diopter(D)to−5.00 D and astigmatism with more than−1.50 D were recruited.The enrolled adolescents were divided into OK group and spectacle group.During regular followup,adolescents were measured respectively at pre-wear,1,3,and 6mo after treatment.The follow-up included uncorrected distance visual acuity(UDVA),axial length(AL),superficial capillary plexus density(SCPD),deep capillary plexus density(DCPD),central retinal thickness(CRT),foveal avascular zone area(FAZ-A),foveal avascular zone perimeter(FAZ-P)and foveal vessel density in a 300-μmwide region around foveal avascular zone(FD-300).The collected data were analyzed using statistical methods.RESULTS:By one month,SCPD significantly increased in the fovea and superior retina,and DCPD significantly increased inferiorly in OK group compared to spectacle group(P<0.05).By three months,there were significant increases in SCPD in the fovea and inferior retina,and DCPD in the parafovea,superior,and inferior retina in OK group(P<0.05),while the increase in SCPD and DCPD in the fovea were observed by six months(P<0.05).The FD-300 significantly increased at every follow-up in OK group compared to spectacle group(P<0.05).No significant differences in the CRT,FAZ-A and FAZ-P and FD-300 were observed between two groups(P>0.05).OK group showed a significant improvement in UDVA after wearing OK,compared to spectacle group(P<0.01),while the AL did not show a significant difference between two groups(P>0.05).CONCLUSION:Short-term OK worn can increase local retinal vessel density in adolescents with low-to-moderate myopia. 展开更多
关键词 optical coherence tomography angiography ORTHOKERATOLOGY MYOPIA axial length retinal capillary plexus density
下载PDF
Efficient stochastic parallel gradient descent training for on-chip optical processor 被引量:1
6
作者 Yuanjian Wan Xudong Liu +4 位作者 Guangze Wu Min Yang Guofeng Yan Yu Zhang Jian Wang 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第4期5-15,共11页
In recent years,space-division multiplexing(SDM)technology,which involves transmitting data information on multiple parallel channels for efficient capacity scaling,has been widely used in fiber and free-space optical... In recent years,space-division multiplexing(SDM)technology,which involves transmitting data information on multiple parallel channels for efficient capacity scaling,has been widely used in fiber and free-space optical communication sys-tems.To enable flexible data management and cope with the mixing between different channels,the integrated reconfig-urable optical processor is used for optical switching and mitigating the channel crosstalk.However,efficient online train-ing becomes intricate and challenging,particularly when dealing with a significant number of channels.Here we use the stochastic parallel gradient descent(SPGD)algorithm to configure the integrated optical processor,which has less com-putation than the traditional gradient descent(GD)algorithm.We design and fabricate a 6×6 on-chip optical processor on silicon platform to implement optical switching and descrambling assisted by the online training with the SPDG algorithm.Moreover,we apply the on-chip processor configured by the SPGD algorithm to optical communications for optical switching and efficiently mitigating the channel crosstalk in SDM systems.In comparison with the traditional GD al-gorithm,it is found that the SPGD algorithm features better performance especially when the scale of matrix is large,which means it has the potential to optimize large-scale optical matrix computation acceleration chips. 展开更多
关键词 optical communications optical signal processing channel descrambling optical neural network chip silicon photonics
下载PDF
The Probability Density Function Related to Shallow Cumulus Entrainment Rate and Its Influencing Factors in a Large-Eddy Simulation 被引量:3
7
作者 Lei ZHU Chunsong LU +5 位作者 Xiaoqi XU Xin HE Junjun LI Shi LUO Yuan WANG Fan WANG 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第1期173-187,共15页
The process of entrainment-mixing between cumulus clouds and the ambient air is important for the development of cumulus clouds.Accurately obtaining the entrainment rate(λ)is particularly important for its parameteri... The process of entrainment-mixing between cumulus clouds and the ambient air is important for the development of cumulus clouds.Accurately obtaining the entrainment rate(λ)is particularly important for its parameterization within the overall cumulus parameterization scheme.In this study,an improved bulk-plume method is proposed by solving the equations of two conserved variables simultaneously to calculateλof cumulus clouds in a large-eddy simulation.The results demonstrate that the improved bulk-plume method is more reliable than the traditional bulk-plume method,becauseλ,as calculated from the improved method,falls within the range ofλvalues obtained from the traditional method using different conserved variables.The probability density functions ofλfor all data,different times,and different heights can be well-fitted by a log-normal distribution,which supports the assumed stochastic entrainment process in previous studies.Further analysis demonstrate that the relationship betweenλand the vertical velocity is better than other thermodynamic/dynamical properties;thus,the vertical velocity is recommended as the primary influencing factor for the parameterization ofλin the future.The results of this study enhance the theoretical understanding ofλand its influencing factors and shed new light on the development ofλparameterization. 展开更多
关键词 large-eddy simulation cumulus clouds entrainment rate probability density functions spatial and temporal distribution
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images 被引量:2
8
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
Multi-dimensional multiplexing optical secret sharing framework with cascaded liquid crystal holograms 被引量:3
9
作者 Keyao Li Yiming Wang +6 位作者 Dapu Pi Baoli Li Haitao Luan Xinyuan Fang Peng Chen Yanqing Lu Min Gu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第1期28-35,共8页
Secret sharing is a promising technology for information encryption by splitting the secret information into different shares.However,the traditional scheme suffers from information leakage in decryption process since... Secret sharing is a promising technology for information encryption by splitting the secret information into different shares.However,the traditional scheme suffers from information leakage in decryption process since the amount of available information channels is limited.Herein,we propose and demonstrate an optical secret sharing framework based on the multi-dimensional multiplexing liquid crystal(LC)holograms.The LC holograms are used as spatially separated shares to carry secret images.The polarization of the incident light and the distance between different shares are served as secret keys,which can significantly improve the information security and capacity.Besides,the decryption condition is also restricted by the applied external voltage due to the variant diffraction efficiency,which further increases the information security.In implementation,an artificial neural network(ANN)model is developed to carefully design the phase distribution of each LC hologram.With the advantage of high security,high capacity and simple configuration,our optical secret sharing framework has great potentials in optical encryption and dynamic holographic display. 展开更多
关键词 holographic encryption optical secret sharing cascaded liquid crystal hologram multi-dimensional multiplexing
下载PDF
Grain yield and N uptake of maize in response to increased plant density under reduced water and nitrogen supply conditions 被引量:2
10
作者 Jingui Wei Qiang Chai +5 位作者 Wen Yin Hong Fan Yao Guo Falong Hu Zhilong Fan QimingWang 《Journal of Integrative Agriculture》 SCIE CSCD 2024年第1期122-140,共19页
The development of modern agriculture requires the reduction of water and chemical N fertilizer inputs.Increasing the planting density can maintain higher yields,but also consumes more of these restrictive resources.H... The development of modern agriculture requires the reduction of water and chemical N fertilizer inputs.Increasing the planting density can maintain higher yields,but also consumes more of these restrictive resources.However,whether an increased maize density can compensate for the negative effects of reduced water and N supply on grain yield and N uptake in the arid irrigated areas remains unknown.This study is part of a long-term positioning trial that started in 2016.A split-split plot field experiment of maize was implemented in the arid irrigated area of northwestern China in 2020 to 2021.The treatments included two irrigation levels:local conventional irrigation reduced by 20%(W1,3,240 m^(3)ha^(-1))and local conventional irrigation(W2,4,050 m^(3)ha^(-1));two N application rates:local conventional N reduced by 25%(N1,270 kg ha^(-1))and local conventional N(360 kg ha^(-1));and three planting densities:local conventional density(D1,75,000 plants ha^(-1)),density increased by 30%(D2,97,500 plants ha-1),and density increased by 60%(D3,120,000 plants ha^(-1)).Our results showed that the grain yield and aboveground N accumulation of maize were lower under the reduced water and N inputs,but increasing the maize density by 30% can compensate for the reductions of grain yield and aboveground N accumulation caused by the reduced water and N supply.When water was reduced while the N application rate remained unchanged,increasing the planting density by 30% enhanced grain yield by 13.9% and aboveground N accumulation by 15.3%.Under reduced water and N inputs,increasing the maize density by 30% enhanced N uptake efficiency and N partial factor productivity,and it also compensated for the N harvest index and N metabolic related enzyme activities.Compared with W2N2D1,the N uptake efficiency and N partial factor productivity increased by 28.6 and 17.6%under W1N1D2.W1N2D2 had 8.4% higher N uptake efficiency and 13.9% higher N partial factor productivity than W2N2D1.W1N2D2 improved urease activity and nitrate reductase activity by 5.4% at the R2(blister)stage and 19.6% at the V6(6th leaf)stage,and increased net income and the benefit:cost ratio by 22.1 and 16.7%,respectively.W1N1D2 and W1N2D2 reduced the nitrate nitrogen and ammoniacal nitrogen contents at the R6 stage in the 40-100 cm soil layer,compared with W2N2D1.In summary,increasing the planting density by 30% can compensate for the loss of grain yield and aboveground N accumulation under reduced water and N inputs.Meanwhile,increasing the maize density by 30% improved grain yield and aboveground N accumulation when water was reduced by 20% while the N application rate remained constant in arid irrigation areas. 展开更多
关键词 water and N reduction plant density MAIZE grain yield N uptake compensation effect
下载PDF
Evolutionary history shapes variation of wood density of tree species across the world 被引量:1
11
作者 Fangbing Li Hong Qian +7 位作者 Jordi Sardans Dzhamal Y.Amishev Zixuan Wang Changyue Zhang Tonggui Wu Xiaoniu Xu Xiao Tao Xingzhao Huang 《Plant Diversity》 SCIE CAS CSCD 2024年第3期283-293,共11页
The effect of evolutionary history on wood density variation may play an important role in shaping variation in wood density,but this has largely not been tested.Using a comprehensive global dataset including 27,297 m... The effect of evolutionary history on wood density variation may play an important role in shaping variation in wood density,but this has largely not been tested.Using a comprehensive global dataset including 27,297 measurements of wood density from 2621 tree species worldwide,we test the hypothesis that the legacy of evolutionary history plays an important role in driving the variation of wood density among tree species.We assessed phylogenetic signal in different taxonomic(e.g.,angiosperms and gymnosperms)and ecological(e.g.,tropical,temperate,and boreal)groups of tree species,explored the biogeographical and phylogenetic patterns of wood density,and quantified the relative importance of current environmental factors(e.g.,climatic and soil variables)and evolutionary history(i.e.,phylogenetic relatedness among species and lineages)in driving global wood density variation.We found that wood density displayed a significant phylogenetic signal.Wood density differed among different biomes and climatic zones,with higher mean values of wood density in relatively drier regions(highest in subtropical desert).Our study revealed that at a global scale,for angiosperms and gymnosperms combined,phylogeny and species(representing the variance explained by taxonomy and not direct explained by long-term evolution process)explained 84.3%and 7.7%of total wood density variation,respectively,whereas current environment explained 2.7%of total wood density variation when phylogeny and species were taken into account.When angiosperms and gymnosperms were considered separately,the three proportions of explained variation are,respectively,84.2%,7.5%and 6.7%for angiosperms,and 45.7%,21.3%and 18.6%for gymnosperms.Our study shows that evolutionary history outpaced current environmental factors in shaping global variation in wood density. 展开更多
关键词 Wood density PHYLOGENY ANGIOSPERMS GYMNOSPERMS Climate factors Biophysical parameters
下载PDF
A facile strategy for tuning the density of surface-grafted biomolecules for melt extrusion-based additive manufacturing applications 被引量:1
12
作者 I.A.O.Beeren G.Dos Santos +8 位作者 P.J.Dijkstra C.Mota J.Bauer H.Ferreira Rui L.Reis N.Neves S.Camarero-Espinosa M.B.Baker L.Moroni 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第3期277-291,共15页
Melt extrusion-based additive manufacturing(ME-AM)is a promising technique to fabricate porous scaffolds for tissue engi-neering applications.However,most synthetic semicrystalline polymers do not possess the intrinsi... Melt extrusion-based additive manufacturing(ME-AM)is a promising technique to fabricate porous scaffolds for tissue engi-neering applications.However,most synthetic semicrystalline polymers do not possess the intrinsic biological activity required to control cell fate.Grafting of biomolecules on polymeric surfaces of AM scaffolds enhances the bioactivity of a construct;however,there are limited strategies available to control the surface density.Here,we report a strategy to tune the surface density of bioactive groups by blending a low molecular weight poly(ε-caprolactone)5k(PCL5k)containing orthogonally reactive azide groups with an unfunctionalized high molecular weight PCL75k at different ratios.Stable porous three-dimensional(3D)scaf-folds were then fabricated using a high weight percentage(75 wt.%)of the low molecular weight PCL 5k.As a proof-of-concept test,we prepared films of three different mass ratios of low and high molecular weight polymers with a thermopress and reacted with an alkynated fluorescent model compound on the surface,yielding a density of 201-561 pmol/cm^(2).Subsequently,a bone morphogenetic protein 2(BMP-2)-derived peptide was grafted onto the films comprising different blend compositions,and the effect of peptide surface density on the osteogenic differentiation of human mesenchymal stromal cells(hMSCs)was assessed.After two weeks of culturing in a basic medium,cells expressed higher levels of BMP receptor II(BMPRII)on films with the conjugated peptide.In addition,we found that alkaline phosphatase activity was only significantly enhanced on films contain-ing the highest peptide density(i.e.,561 pmol/cm^(2)),indicating the importance of the surface density.Taken together,these results emphasize that the density of surface peptides on cell differentiation must be considered at the cell-material interface.Moreover,we have presented a viable strategy for ME-AM community that desires to tune the bulk and surface functionality via blending of(modified)polymers.Furthermore,the use of alkyne-azide“click”chemistry enables spatial control over bioconjugation of many tissue-specific moieties,making this approach a versatile strategy for tissue engineering applications. 展开更多
关键词 Additive manufacturing BLENDING Surface functionalization Surface density Click chemistry HUMAN
下载PDF
Coherent optical frequency transfer via 972-km fiber link 被引量:1
13
作者 邓雪 张翔 +8 位作者 臧琦 焦东东 王丹 刘杰 高静 许冠军 董瑞芳 刘涛 张首刚 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期277-282,共6页
We demonstrate coherent optical frequency dissemination over a distance of 972 km by cascading two spans where the phase noise is passively compensated for.Instead of employing a phase discriminator and a phase lockin... We demonstrate coherent optical frequency dissemination over a distance of 972 km by cascading two spans where the phase noise is passively compensated for.Instead of employing a phase discriminator and a phase locking loop in the conventional active phase control scheme,the passive phase noise cancellation is realized by feeding double-trip beat-note frequency to the driver of the acoustic optical modulator at the local site.This passive scheme exhibits fine robustness and reliability,making it suitable for long-distance and noisy fiber links.An optical regeneration station is used in the link for signal amplification and cascaded transmission.The phase noise cancellation and transfer instability of the 972-km link is investigated,and transfer instability of 1.1×10^(-19)at 10^(4)s is achieved.This work provides a promising method for realizing optical frequency distribution over thousands of kilometers by using fiber links. 展开更多
关键词 optical frequency transfer fiber link phase noise cancellation
下载PDF
Glaucoma surgery experiments using digital microscope-integrated optical coherence tomography and OCT-compatible instruments 被引量:1
14
作者 Tianliang Jiang Jinyu Fan +2 位作者 Ning Tang Yi He Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第5期105-113,共9页
There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)... There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice. 展开更多
关键词 Microscope-integrated optical coherence tomography OCT-compatible instruments glaucoma surgery TRABECULECTOMY CANALOPLASTY
下载PDF
Flexible,high-density,laminated ECoG electrode array for high spatiotemporal resolution foci diagnostic localization of refractory epilepsy 被引量:1
15
作者 Yafeng Liu Zhouheng Wang +4 位作者 Yang Jiao Ying Chen Guangyuan Xu Yinji Ma Xue Feng 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第4期388-398,共11页
High spatiotemporal resolution brain electrical signals are critical for basic neuroscience research and high-precision focus diagnostic localization,as the spatial scale of some pathologic signals is at the submillim... High spatiotemporal resolution brain electrical signals are critical for basic neuroscience research and high-precision focus diagnostic localization,as the spatial scale of some pathologic signals is at the submillimeter or micrometer level.This entails connecting hundreds or thousands of electrode wires on a limited surface.This study reported a class of flexible,ultrathin,highdensity electrocorticogram(ECoG)electrode arrays.The challenge of a large number of wiring arrangements was overcome by a laminated structure design and processing technology improvement.The flexible,ultrathin,high-density ECoG electrode array was conformably attached to the cortex for reliable,high spatial resolution electrophysiologic recordings.The minimum spacing between electrodes was 15μm,comparable to the diameter of a single neuron.Eight hundred electrodes were prepared with an electrode density of 4444 mm^(-2).In focal epilepsy surgery,the flexible,high-density,laminated ECoG electrode array with 36 electrodes was applied to collect epileptic spike waves inrabbits,improving the positioning accuracy of epilepsy lesions from the centimeter to the submillimeter level.The flexible,high-density,laminated ECoG electrode array has potential clinical applications in intractable epilepsy and other neurologic diseases requiring high-precision electroencephalogram acquisition. 展开更多
关键词 Electrocorticogram(ECoG)electrode EPILEPSY High density High resolution Laminated structure
下载PDF
Method to measure tree-ring width,density,elemental composition,and stable carbon and oxygen isotopes using one sample 被引量:1
16
作者 Chenxi Xu Yaru Zhao +4 位作者 Wenling An Qingyu Zhao Yucheng Liu Masaki Sano Takeshi Nakatsuka 《Journal of Forestry Research》 SCIE EI CAS CSCD 2024年第3期167-174,共8页
Tree-ring width(RW),density,elemental com-position,and stable carbon and oxygen isotope(δ^(13)C,δ^(18)O)are widely used as proxies to assess climate change,ecology,and environmental pollution;however,a specific pret... Tree-ring width(RW),density,elemental com-position,and stable carbon and oxygen isotope(δ^(13)C,δ^(18)O)are widely used as proxies to assess climate change,ecology,and environmental pollution;however,a specific pretreat-ment has been needed for each proxy.Here,we developed a method by which each proxy can be measured in the same sample.First,the sample is polished for ring width meas-urement.After obtaining the ring width data,the sample is cut to form a 1-mm-thick wood plate.The sample is then mounted in a vertical sample holder,and gradually scanned by an X-ray beam.Simultaneously,the count rates of the fluorescent photons of elements(for chemical characteriza-tion)and a radiographic grayscale image(for wood density)are obtained,i.e.the density and the element content are obtained.Then,cellulose is isolated from the 1-mm wood plate by removal of lignin,and hemicellulose.After producing this cellulose plate,cellulose subsamples are separated by knife under the microscope for inter-annual and intra-annual stable carbon and oxygen isotope(δ^(13)C,δ^(18)O)analysis.Based on this method,RW,density,elemental composition,δ^(13)C,and δ^(18)O can be measured from the same sample,which reduces sample amount and treatment time,and is helpful for multi-proxy comparison and combination research. 展开更多
关键词 Tree-ring width Tree-ring density Tree-ring elemental composition Tree-ring stable carbon and oxygenisotopes
下载PDF
Multilevel carbon architecture of subnanoscopic silicon for fast‐charging high‐energy‐density lithium‐ion batteries 被引量:1
17
作者 Meisheng Han Yongbiao Mu +2 位作者 Lei Wei Lin Zeng Tianshou Zhao 《Carbon Energy》 SCIE EI CAS CSCD 2024年第4期256-268,共13页
Silicon(Si)is widely used as a lithium‐ion‐battery anode owing to its high capacity and abundant crustal reserves.However,large volume change upon cycling and poor conductivity of Si cause rapid capacity decay and p... Silicon(Si)is widely used as a lithium‐ion‐battery anode owing to its high capacity and abundant crustal reserves.However,large volume change upon cycling and poor conductivity of Si cause rapid capacity decay and poor fast‐charging capability limiting its commercial applications.Here,we propose a multilevel carbon architecture with vertical graphene sheets(VGSs)grown on surfaces of subnanoscopically and homogeneously dispersed Si–C composite nanospheres,which are subsequently embedded into a carbon matrix(C/VGSs@Si–C).Subnanoscopic C in the Si–C nanospheres,VGSs,and carbon matrix form a three‐dimensional conductive and robust network,which significantly improves the conductivity and suppresses the volume expansion of Si,thereby boosting charge transport and improving electrode stability.The VGSs with vast exposed edges considerably increase the contact area with the carbon matrix and supply directional transport channels through the entire material,which boosts charge transport.The carbon matrix encapsulates VGSs@Si–C to decrease the specific surface area and increase tap density,thus yielding high first Coulombic efficiency and electrode compaction density.Consequently,C/VGSs@Si–C delivers excellent Li‐ion storage performances under industrial electrode conditions.In particular,the full cells show high energy densities of 603.5 Wh kg^(−1)and 1685.5 Wh L^(−1)at 0.1 C and maintain 80.7%of the energy density at 3 C. 展开更多
关键词 fast charging high energy densities lithium‐ion batteries multilevel carbon architecture subnanoscopic silicon anode
下载PDF
11.2 W/mm power density AlGaN/GaN high electron-mobility transistors on a GaN substrate 被引量:1
18
作者 Yansheng Hu Yuangang Wang +11 位作者 Wei Wang Yuanjie Lv Hongyu Guo Zhirong Zhang Hao Yu Xubo Song Xingye zhou Tingting Han Shaobo Dun Hongyu Liu Aimin Bu Zhihong Feng 《Journal of Semiconductors》 EI CAS CSCD 2024年第1期38-41,共4页
In this letter,high power density AlGaN/GaN high electron-mobility transistors(HEMTs)on a freestanding GaN substrate are reported.An asymmetricΓ-shaped 500-nm gate with a field plate of 650 nm is introduced to improv... In this letter,high power density AlGaN/GaN high electron-mobility transistors(HEMTs)on a freestanding GaN substrate are reported.An asymmetricΓ-shaped 500-nm gate with a field plate of 650 nm is introduced to improve microwave power performance.The breakdown voltage(BV)is increased to more than 200 V for the fabricated device with gate-to-source and gate-to-drain distances of 1.08 and 2.92μm.A record continuous-wave power density of 11.2 W/mm@10 GHz is realized with a drain bias of 70 V.The maximum oscillation frequency(f_(max))and unity current gain cut-off frequency(f_(t))of the AlGaN/GaN HEMTs exceed 30 and 20 GHz,respectively.The results demonstrate the potential of AlGaN/GaN HEMTs on freestanding GaN substrates for microwave power applications. 展开更多
关键词 freestanding GaN substrates AlGaN/GaN HEMTs continuous-wave power density breakdown voltage Γ-shaped gate
下载PDF
Three-dimensional choroidal vascularity index and choroidal thickness in fellow eyes of acute and chronic primary angle-closure using swept-source optical coherence tomography 被引量:1
19
作者 Hai-Li Huang Guan-Hong Wang +1 位作者 Liang-Liang Niu Xing-Huai Sun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期42-52,共11页
AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of... AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of normal controls.METHODS:This study included 37 patients with unilateral APAC,37 with asymmetric CPACG without prior treatment,and 36 healthy participants.Using swept-source optical coherence tomography(SS-OCT),the macular and peripapillary choroidal thickness and three-dimensional CVI were measured and compared globally and sectorally.Pearson’s correlation analysis and multivariate regression models were used to evaluate choroidal thickness or CVI with related factors.RESULTS:The mean subfoveal CVIs were 0.35±0.10,0.33±0.09,and 0.29±0.04,and the mean subfoveal choroidal thickness were 315.62±52.92,306.22±59.29,and 262.69±45.55μm in the F-APAC,F-CPACG,and normal groups,respectively.All macular sectors showed significantly higher CVIs and choroidal thickness in the F-APAC and F-CPACG eyes than in the normal eyes(P<0.05),while there were no significant differences between the F-APAC and F-CPACG eyes.In the peripapillary region,the mean overall CVIs were 0.21±0.08,0.20±0.08,and 0.19±0.05,and the mean overall choroidal thickness were 180.45±54.18,174.82±50.67,and 176.18±37.94μm in the F-APAC,F-CPACG,and normal groups,respectively.There were no significant differences between any of the two groups in all peripapillary sectors.Younger age,shorter axial length,and the F-APAC or F-CPACG diagnosis were significantly associated with higher subfoveal CVI and thicker subfoveal choroidal thickness(P<0.05).CONCLUSION:The fellow eyes of unilateral APAC or asymmetric CPACG have higher macular CVI and choroidal thickness than those of the normal controls.Neither CVI nor choroidal thickness can distinguish between eyes predisposed to APAC or CPACG.A thicker choroid with a higher vascular volume may play a role in the pathogenesis of primary angle-closure glaucoma. 展开更多
关键词 choroidal thickness choroidal vascularity index swept-source optical coherence tomography acute primary angle-closure chronic primary angle-closure glaucoma
下载PDF
Quantifying peripapillary vessel density and retinal nerve fibre layer in type 1 diabetic children without clinically detectable retinopathy using OCTA
20
作者 Ling Chen Yun Feng +2 位作者 Sha-Sha Zhang Yan-Fang Liu Ping Lin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期278-281,共4页
AIM:To quantify changes in radial peripapillary capillary vessel density(ppVD)and the peripapillary retinal nerve fiber layer(pRNFL)in children with type 1 diabetes without clinical diabetic retinopathy by optical coh... AIM:To quantify changes in radial peripapillary capillary vessel density(ppVD)and the peripapillary retinal nerve fiber layer(pRNFL)in children with type 1 diabetes without clinical diabetic retinopathy by optical coherence tomography angiography(OCTA),providing a basis for early retinopathy in children with type 1 diabetes.METHODS:This was a retrospective study.A total of 30 patients(3–14y)with type 1 diabetes without clinical diabetic retinopathy(NDR group)were included.A total of 30 age-matched healthy subjects were included as the normal control group(CON group).The HbA1c level in the last 3mo was measured once in the NDR group.The pRNFL thickness and ppVD were automatically measured,and the mean pRNFL and ppVD were calculated in the nasal,inferior,temporal,and superior quadrants.The changes in ppVD and pRNFL in the two groups were analyzed.RESULTS:Compared with CON group,the nasal and superior ppVDs decreased in the NDR group(all P<0.01).The thickness of the nasal pRNFL decreased significantly(P<0.01),while the inferior,temporal and superior pRNFLs slightly decreased but not significant in the NDR group(all P>0.05).Person and Spearman correlation analysis of ppVD and pRNFL thickness in each quadrant of the NDR group showed a positive correlation between nasal and superior(all P<0.01),while inferior and temporal had no significant correlation(all P>0.05).There was no significant correlation between the HbA1c level and ppVD and pRNFL in any quadrant(all P>0.05).There was no significant correlation between the course of diabetes mellitus and ppVD and pRNFL in any quadrant(all P>0.05).CONCLUSION:ppVD and pRNFL decrease in eyes of children with type 1 diabetes before clinically detectable retinopathy and OCTA is helpful for early monitoring. 展开更多
关键词 diabetic retinopathy CHILDREN peripapillary vessel density peripapillary retinal nerve fiber layer optical coherence tomography angiography
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部