期刊文献+
共找到13篇文章
< 1 >
每页显示 20 50 100
Determining the imaging plane of a retinal capillary layer in adaptive optical imaging 被引量:1
1
作者 杨乐宝 胡立发 +4 位作者 李大禹 曹召良 穆全全 马骥 宣丽 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期110-116,共7页
Even in the early stage,endocrine metabolism disease may lead to micro aneurysms in retinal capillaries whose diameters are less than 10 μm.However,the fundus cameras used in clinic diagnosis can only obtain images o... Even in the early stage,endocrine metabolism disease may lead to micro aneurysms in retinal capillaries whose diameters are less than 10 μm.However,the fundus cameras used in clinic diagnosis can only obtain images of vessels larger than 20 μm in diameter.The human retina is a thin and multiple layer tissue,and the layer of capillaries less than10 μm in diameter only exists in the inner nuclear layer.The layer thickness of capillaries less than 10 μm in diameter is about 40 μm and the distance range to rod&cone cell surface is tens of micrometers,which varies from person to person.Therefore,determining reasonable capillary layer(CL) position in different human eyes is very difficult.In this paper,we propose a method to determine the position of retinal CL based on the rod&cone cell layer.The public positions of CL are recognized with 15 subjects from 40 to 59 years old,and the imaging planes of CL are calculated by the effective focal length of the human eye.High resolution retinal capillary imaging results obtained from 17 subjects with a liquid crystal adaptive optics system(LCAOS) validate our method.All of the subjects' CLs have public positions from 127 μm to 147 μm from the rod&cone cell layer,which is influenced by the depth of focus. 展开更多
关键词 liquid crystal device adaptive optics capillary layer position retinal imaging
下载PDF
Diagnostic capability of peripapillary retinal nerve fiber layer parameters in time-domain versus spectral-domain optical coherence tomography for assessing glaucoma in high myopia 被引量:2
2
作者 Mei-Ching Teng Yi-Chieh Poon +7 位作者 Kuo-Chi Hung Hsueh-Wen Chang Ing-Chou Lai Jen-Chia Tsai Pei-Wen Lin Chien-Yun Wu Chueh-Tan Chen Pei-Chang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第7期1106-1112,共7页
AIM: To evaluate and compare the diagnostic capabilities of peripapillary retinal nerve fiber layer(p-RNFL) parameters of Spectralis optical coherence tomography(OCT) versus Stratus OCT to detect glaucoma in pati... AIM: To evaluate and compare the diagnostic capabilities of peripapillary retinal nerve fiber layer(p-RNFL) parameters of Spectralis optical coherence tomography(OCT) versus Stratus OCT to detect glaucoma in patients with high myopia. METHODS: This is a retrospective, cross-sectional study. Sixty highly myopic eyes of 60 patients were enrolled, with 30 eyes in the glaucoma group and 30 eyes in the control group. All eyes received peripapillary imaging of the optic disc using Stratus and Spectralis OCT. Areas under the receiver operating characteristic curve(AUROC) and the sensitivity at specificity of 〉80% and 〉95% for p-RNFL parameters obtained using the two devices to diagnose glaucoma were analysed and compared. RESULTS: In Spectralis OCT, p-RNFL thickness parameters with the largest AUROC were the temporal-inferior sector(0.974) and the inferior quadrant(0.951), whereas in Stratus OCT, the best parameters were the 7-o'clock sector(0.918) and the inferior quadrant(0.918). Compared to the Stratus OCT parameters, the Spectralis OCT parameters demonstrated generally higher AUROC; however, the difference was not statistically significant. CONCLUSION: The best p-RNFL parameters for diagnosing glaucoma in patients with high myopia were the temporal-inferior sector on Spectralis OCT and the 7-o'clock sector on Stratus OCT. There were no significant differences between the AUROCs for Spectralis OCT and Stratus OCT, which suggest that the glaucoma diagnostic capabilities of these two devices in patients with high myopia are similar. 展开更多
关键词 diagnostic capability glaucoma high myopia optical coherence tomography retinal nerve fiber layer
下载PDF
A NOVEL OPTICALLY TRANSPARENT THIN LAYER ELECTRODE FOR IN SITU IR SPECTROELECTROCHEMISTRY
3
作者 YiJinXIAO Han Xi YANG ChuanSin CHA (Dept.of Chemistry,Wuhan Univ.,430072)Zi Gang FENG Hua TONG (Anal.Center,Wuhan Univ.) 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第4期329-330,共2页
A novel design of IR OTTLE is shown to have sufficient sensitivity and experi- mental simplicity for obtaining IR spectra of the species generated during electrochemical oxidation-reduction.
关键词 IR A NOVEL opticalLY TRANSPARENT THIN layer ELECTRODE FOR IN SITU IR SPECTROELECTROCHEMISTRY
下载PDF
Brightness of Blue/Violet Luminescent Nano-Crystalline AZO and IZO Thin Films with Effect of Layer Number:For High Optical Performance
4
作者 Panagiota KORAL Songül FAT VAROL +1 位作者 Michael KOMPITSAS Mihaela GIRTAN 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第5期80-83,共4页
From different reports, it (AZO) and indium-doped including usage areas. We nanocrystalline films with is realized that there is a need to consider all sides of aluminum-doped zinc oxide zinc oxide (IZO) thin film... From different reports, it (AZO) and indium-doped including usage areas. We nanocrystalline films with is realized that there is a need to consider all sides of aluminum-doped zinc oxide zinc oxide (IZO) thin films with their optical, luminescence and surface properties establish an assessment to carry out further information to summarize AZO and IZO impact of the layer number. 展开更多
关键词 of in is AZO ZnO Brightness of Blue/Violet Luminescent Nano-Crystalline AZO and IZO Thin Films with Effect of layer Number:For High optical Performance for that with
下载PDF
Peripapillary retinal nerve fibre layer thickness measurement with SD-OCT in normal and glaucomatous eyes:distribution and correlation with age 被引量:6
5
作者 George Kampougeris Dimitrios Spyropoulos +2 位作者 Adrianna Mitropoulou Aggeliki Zografou Pericles Kosmides 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期662-665,共4页
AIMTo determine peripapillary retinal fiber layer thickness (RNFL) measured with spectral domain optical coherence tomography (SD-OCT) in normal and glaucomatous eyes in a large sample of exclusively white population ... AIMTo determine peripapillary retinal fiber layer thickness (RNFL) measured with spectral domain optical coherence tomography (SD-OCT) in normal and glaucomatous eyes in a large sample of exclusively white population and compare results with other similarly constructed studies. 展开更多
关键词 SD-OCT retinal fiber layer thickness optic disc
下载PDF
Comparison of peripapillary retinal nerve fiber layer thickness between myopia severity groups and controls 被引量:7
6
作者 Evelyn Li Min Tai Jiunn Loong Ling +2 位作者 Eng Hui Gan Hussein Adil Wan-Hiram Wan-Hazabbah 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第2期274-278,共5页
AIM: To compare the peripapillary retinal nerve fiber layer(RNFL) thickness measured via optical coherence tomography(OCT) between different groups of myopia severity and controls. METHODS: This was a prospectiv... AIM: To compare the peripapillary retinal nerve fiber layer(RNFL) thickness measured via optical coherence tomography(OCT) between different groups of myopia severity and controls. METHODS: This was a prospective cross-sectional study. All subjects underwent a full ophthalmic examination, refraction, visual field analysis and A-scan biometry. Myopic patients were classified as low myopia(LM) [spherical equivalent(SE) from greater than-0.5 D, up to-3.0 D], moderate myopia(MM; SE greater than-3.0 D, up to-6.0 D) and high myopia(HM; SE greater than-6.0 D). The control group consisted of emmetropic(EM) patients(SE from +0.5 D to-0.5 D). A Zeiss Cirrus HD-OCT machine was used to measure the peripapillary RNFL thickness of both eyes of each subject. The mean peripapillary RNFL thickness between groups was compared using both analysis of variance and analysis of covariance.RESULTS: A total of 403 eyes of 403 subjects were included in this study. The mean age was 31.48±10.23 y. There were 180(44.7%) eyes with EM, 124(30.8%) with LM, 73(18.1%) with MM and 26(6.5%) with HM. All groups of myopia severity had a thinner average RNFL than the EM group, but after controlling for gender, age, and axial eye length, only the HM group differed significantly from the EM group(P=0.017). Likewise, the superior, inferior and nasal RNFL was thinner in all myopia groups compared to controls, but after controlling for confounders, only the inferior quadrant RNFL was significantly thinner in the HM group, when compared to the EM group(P=0.017). CONCLUSION: The average and inferior quadrant RNFL is thinner in highly myopic eyes compared to emmetropic eyes. Refractive status must be taken into consideration when interpreting the OCT of myopic patients, as RNFL thickness varies with the degree of myopia. 展开更多
关键词 optical coherence tomography retinal nerve fiber layer myopia
下载PDF
Correlation between macular ganglion cell-inner plexiform layer thickness and visual acuity after resolution of the macular edema secondary to central retinal vein occlusion 被引量:1
7
作者 Hyun Ju Kim Han Gyul Yoon Seong Taeck Kim 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第2期256-261,共6页
AIM: To examine the thickness of the ganglion cell-inner plexiform layer(GCIPL) in eyes with resolved macular edema(ME) in non-ischemic central retinal vein occlusion(CRVO), applying spectral-domain optical coh... AIM: To examine the thickness of the ganglion cell-inner plexiform layer(GCIPL) in eyes with resolved macular edema(ME) in non-ischemic central retinal vein occlusion(CRVO), applying spectral-domain optical coherence tomography(SD-OCT), and its relationship with visual acuity.METHODS: The retrospective observational case-control study included 30 eyes of non-ischemic CRVO patients with resolved ME(ME eyes) after treatment, and 30 eyes of non-ischemic CRVO patients without ME(non-ME eyes). The macular GCIPL thickness, peripapillary retinal nerve fiber layer(p RNFL) thickness and central macular thickness(CMT) were measured on a SD-OCT scan. Linear regression analyses were performed to determine the correlation between the thickness of each and the visual acuity(VA).RESULTS: No significant difference in average GCIPL thickness, mean pR NFL thickness and CMT were observed between ME group and non-ME group(P=0.296, 0.183, 0.846). But, minimum GCIPL thickness was reduced in ME eyes compared with non-ME eyes(P=0.022). Final VA significantly correlated with the minimum GCIPL thickness in ME eyes(r=-0.482, P=0.007), whereas no correlation was found with average GCIPL thickness, average pR NFL thickness and mean CMT.CONCLUSION: Minimum GCIPL thickness is reduced in ME eyes compared with non-ME eyes, and correlated with the VA in non-ischemic CRVO. These results propose that inner retinal damage occurring in patients with ME secondary to non-ischemic CRVO may lead to permanent visual defect after treatment. 展开更多
关键词 central retinal vein occlusion ganglion cellinner plexiform layer optical coherence tomography
下载PDF
Retinal ganglion cell-inner plexiform and nerve fiber layers in neuromyelitis optica 被引量:1
8
作者 Sai-Jing Hu Pei-Rong Lu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第1期89-93,共5页
AIM: To determine the thickness of the retinal ganglion cell-inner plexiform layer(GCIPL) and the retinal nerve fiber layer(RNFL) in patients with neuromyelitis optica(NMO).METHODS: We conducted a cross-sectio... AIM: To determine the thickness of the retinal ganglion cell-inner plexiform layer(GCIPL) and the retinal nerve fiber layer(RNFL) in patients with neuromyelitis optica(NMO).METHODS: We conducted a cross-sectional study that included 30 NMO patients with a total of 60 eyes. Based on the presence or absence of optic neuritis(ON), subjects were divided into either the NMO-ON group(30 eyes) or the NMO-ON contra group(10 eyes). A detailed ophthalmologic examination was performed for each group; subsequently, the GCIPL and the RNFL were measured using highdefinition optical coherence tomography(OCT). RESULTS: In the NMO-ON group, the mean GCIPL thickness was 69.28±21.12 μm, the minimum GCIPL thickness was 66.02±10.02 μm, and the RNFL thickness were 109.33±11.23, 110.47±3.10, 64.92±12.71 and 71.21±50.22 μm in the superior, inferior, temporal and nasal quadrants, respectively. In the NMO-ON contra group, the mean GCIPL thickness was 85.12±17.09 μm, the minimum GCIPL thickness was 25.39±25.1 μm, and the RNFL thicknesses were 148.33±23.22, 126.36±23.45, 82.21±22.30 and 83.36±31.28 μm in the superior, inferior, temporal and nasal quadrants, respectively. In the control group, the mean GCIPL thickness was 86.98±22.37 μm, the minimum GCIPL thickness was 85.28±10.75 μm, and the RNFL thicknesses were 150.22±22.73, 154.79±60.23, 82.33±7.01 and 85.62±13.81 μm in the superior, inferior, temporal and nasal quadrants, respectively. The GCIPL and RNFL were thinner in the NMO-ON contra group than in the control group(P〈0.05); additionally, the RNFL was thinner in the inferior quadrant in the NMO-ON group than in the control group(P〈0.05). Significant correlations were observed between the GCIPL and RNFL thickness measurements as well as between thickness measurements and the two visual field parameters of mean deviation(MD) and corrected pattern standard deviation(PSD) in the NMO-ON group(P〈0.05). CONCLUSION: The thickness of the GCIPL and RNFL, as measured using OCT, may indicate optic nerve damage in patients with NMO. 展开更多
关键词 neuromyelitis optica retinal nerve fiber layer thickness ganglion cell-inner plexiform layer optical coherence tomography
下载PDF
Macular thickness as a predictor of loss of visual sensitivity in ethambutol-induced optic neuropathy 被引量:5
9
作者 Chun-xia Peng Ai-di Zhang +4 位作者 Bing Chen Bing-jian Yang Qiu-hong Wang Mo Yang Shi-hui Wei 《Neural Regeneration Research》 SCIE CAS CSCD 2016年第3期469-475,共7页
Ethambutol is a common cause of drug-related optic neuropathy.Prediction of the onset of ethambutol-induced optic neuropathy and consequent drug withdrawal may be an effective method to stop visual loss.Previous studi... Ethambutol is a common cause of drug-related optic neuropathy.Prediction of the onset of ethambutol-induced optic neuropathy and consequent drug withdrawal may be an effective method to stop visual loss.Previous studies have shown that structural injury to the optic nerve occurred earlier than the damage to visual function.Therefore,we decided to detect structural biomarkers marking visual field loss in early stage ethambutol-induced optic neuropathy.The thickness of peripapillary retinal nerve fiber layer,macular thickness and visual sensitivity loss would be observed in 11 ethambutol-induced optic neuropathy patients(22 eyes) using optical coherence tomography.Twenty-four healthy age-and sex-matched participants(48 eyes) were used as controls.Results demonstrated that the temporal peripapillary retinal nerve fiber layer thickness and average macular thickness were thinner in patients with ethambutol-induced optic neuropathy compared with healthy controls.The average macular thickness was strongly positively correlated with central visual sensitivity loss(r2=0.878,P=0.000).These findings suggest that optical coherence tomography can be used to efficiently screen patients.Macular thickness loss could be a potential factor for predicting the onset of ethambutol-induced optic neuropathy. 展开更多
关键词 nerve regeneration ethambutol-induced optic neuropathy optical coherence tomography peripapillary retinal nerve fiber layer ethambutol macular thickness visual sensitivity neural regeneration
下载PDF
Effect of infusion pressure during cataract surgery on ganglion cells measured using isolated-check visual evoked potential 被引量:1
10
作者 Tong Ding Dan-Na Shi +3 位作者 Xiang Fan Mi-Yun Zheng Wei Wang Wei-Qiang Qiu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第1期58-65,共8页
AIM: To detect the relationship between infusion pressure and postoperative ganglion cells function.METHODS: This prospective observational cohort study included sixty-one eyes that underwent uncomplicated cataract ... AIM: To detect the relationship between infusion pressure and postoperative ganglion cells function.METHODS: This prospective observational cohort study included sixty-one eyes that underwent uncomplicated cataract surgery. Patients were divided into two groups according to infusion time(IT) recorded using surgery equipment [Group A: IT〉IT_(mean)(27 eyes); Group B: IT 展开更多
关键词 isolated-check visual evoked potential optical coherence tomography ganglion cell inner plexiform layer cataract extraction
下载PDF
双层衍射光学元件在0.4~0.9 μm宽波段光学系统中的应用 被引量:1
11
作者 杨亮亮 《红外》 CAS 2018年第7期25-28,48,共5页
双层衍射光学元件能够在宽波段光谱范围内工作并具有较高的衍射效率。提出了工作在一定入射角范围内的双层衍射光学元件的复合带宽积分平均衍射效率的数学分析模型。设计了一种工作波段为0.4~0.9 μm的含有双层衍射光学元件的宽波段光... 双层衍射光学元件能够在宽波段光谱范围内工作并具有较高的衍射效率。提出了工作在一定入射角范围内的双层衍射光学元件的复合带宽积分平均衍射效率的数学分析模型。设计了一种工作波段为0.4~0.9 μm的含有双层衍射光学元件的宽波段光学系统。其焦距为28mm,F/#为2,视场达到18°。该系统采用Petzval物镜结构,由四片透镜组成。在60lp/mm处,其调制传递函数(Modulation Transfer Function,MTF)大于0.67。所用双层衍射光学元件在0.4~0.9 μm波段内的带宽积分平均衍射效率高于91%。系统中入射到衍射面上的角度为0°~8.62°。该双层衍射光学元件的复合带宽积分平均衍射效率为97.36%。与传统的折射式宽波段光学系统相比,含有双层衍射光学元件的宽波段光学系统的结构更简单,分辨率更高。 展开更多
关键词 双层衍射光学元件 衍射效率 宽波段 光学设计
下载PDF
Optical rectification in surface layers of germanium
12
作者 张丽 李方野 +10 位作者 王帅 王琦 栾凯然 陈曦 刘秀环 裘令瑛 陈占国 赵纪红 侯丽新 高延军 贾刚 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第10期70-73,共4页
In this Letter, we have demonstrated significant electric field induced(EFI) optical rectification(OR) effects existing in the surface layers of germanium(Ge) and measured the distributions of EFI OR signals alo... In this Letter, we have demonstrated significant electric field induced(EFI) optical rectification(OR) effects existing in the surface layers of germanium(Ge) and measured the distributions of EFI OR signals along the normal directions of surface layers of Ge samples. Based on the experimental results, the ratios of the twoe-order susceptibility components χ2 effTzzz∕χe2 effTeffective secondzxxfor Ge(001), Ge(110), and Ge(111) surface layers can be estimated to be about 0.92, 0.91, and 1.07, respectively. The results indicate that the EFI OR can be used for analyzing the properties on surface layers of Ge, which has potential applications in Ge photonics and optoelectronics. 展开更多
关键词 EFI 110 In optical rectification in surface layers of germanium
原文传递
Prototype of solar ground layer adaptive optics at the 1 m New Vacuum Solar Telescope 被引量:2
13
作者 孔林 张兰强 +5 位作者 朱磊 鲍华 郭友明 饶学军 钟立波 饶长辉 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第10期6-9,共4页
A prototype of a solar ground-layer adaptive optics (GLAO) system, which consists of a multi-direction corre- lating Shack-Hartmann wavefront sensor with 30 effective subapertures and about a 1 arcmin field of view ... A prototype of a solar ground-layer adaptive optics (GLAO) system, which consists of a multi-direction corre- lating Shack-Hartmann wavefront sensor with 30 effective subapertures and about a 1 arcmin field of view (FoV) in each subaperture, a deformable mirror with 151 actuators conjugated to the telescope entrance pupil, and a custom-built real-time controller based on field-programmable gate array and multi-core digital signal processor (DSP), is implemented at the 1 m New Vacuum Solar Telescope at Fuxian Solar Observatory and saw its first light on January 12th, 2016. The on-sky observational results show that the solar image is apparently improved in the whole FoV over 1 arcmin with the GLAO correction. 展开更多
关键词 Prototype of solar ground layer adaptive optics at the 1 m New Vacuum Solar Telescope AO
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部