This study aims to develop a low-cost refractometer for measuring the sucrose content of fruit juice,which is an important factor affecting human health.While laboratory-grade refractometers are expensive and unsuitab...This study aims to develop a low-cost refractometer for measuring the sucrose content of fruit juice,which is an important factor affecting human health.While laboratory-grade refractometers are expensive and unsuitable for personal use,existing low-cost commercial options lack stability and accuracy.To address this gap,we propose a refractometer that replaces the expensive CCD sensor and light source with a conventional LED and a reasonably priced CMOS sensor.By analyzing the output waveform pattern of the CMOS sensor,we achieve high precision with a personal-use-appropriate accuracy of 0.1%.We tested the proposed refractometer by conducting 100 repeated measurements on various fruit juice samples,and the results demonstrate its reliability and consistency.Running on a 48 MHz ARM processor,the algorithm can acquire data within 0.2 seconds.Our low-cost refractometer is suitable for personal health management and small-scale production,providing an affordable and reliable method for measuring sucrose concentration in fruit juice.It improves upon the existing low-cost options by offering better stability and accuracy.This accessible tool has potential applications in optimizing the sucrose content of fruit juice for better health and quality control.展开更多
IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hour...IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hours, 7 days and 14 days after birth showed level of IgG 1000 mg/dl. This level indicated that they have good passive transfer of immunity. Also, in this study colostrum quality fed to calves was detected using Brix Refractometer. The colostrum is of high quality as it contains 50 mg/ml of IgG. This Brix refractometer can be used on the farm level to estimate colostrum IgG content and monitoring colostrum feeding practices. Colostrum with high quality IgG could provide calves with enough IgG to attain successful passive transfer of immunity. Brix and Obione refractometers provide simple, rapid method for estimating IgG concentration on calf serum, thus considered to be the most common method for determining passive transfer failure.展开更多
To break through the limitations of existing pressure standards, which rely on the gravity and toxic mercury,the national metrological institutes prefer a quantum-based pressure standard. Combining the ideal gas law w...To break through the limitations of existing pressure standards, which rely on the gravity and toxic mercury,the national metrological institutes prefer a quantum-based pressure standard. Combining the ideal gas law with helium refractivity measurement, we demonstrate a scheme for the realization of the pressure unit. The refractometer is based on a spectral interferometry with an optical frequency comb and a double-spaced vacuum cell. Through fast Fourier transform of the spectral interferograms of the two beams propagating inside and outside the vacuum cell, the helium refractivity can be obtained with a combined standard uncertainty u(n) of2.9 × 10-9. Moreover, the final u(n) is -8.7 × 10-6 in a measurement range of several megapascals(MPa). Our apparatus is compact, fast(15 ms for one single measurement) and easy to handle. Furthermore, the measurement uncertainty will be improved to-1 × 10-9 or lower if a VIPA-based spectrometer is used. The value of u(p) will thus increase to 3 × 10-6 or better in several MPa.展开更多
Poly(methyltetraphenylphenylsilylene-co-bis(methylphenylsilyl)acetylene) (PSA) was synthesized by the cocondensation reaction of methyltetraphenylphenyldichlorosilane and bis(chloromethylphenylsilyl)acetylene with sod...Poly(methyltetraphenylphenylsilylene-co-bis(methylphenylsilyl)acetylene) (PSA) was synthesized by the cocondensation reaction of methyltetraphenylphenyldichlorosilane and bis(chloromethylphenylsilyl)acetylene with sodium in toluene. The PSA thus obtained was soluble in most organic solvents, and its molecular weight was smaller than that of poly[(disilanylene)acetylenes] with alkyl- or aryl-substitution because of the great steric congestion of tetraphenylphenyl groups. The optical and electronic properties of the polymer were investigated. The results show that PSA has strong UV absorption and fluorescence emission, the maximum UV absorption wavelength of PSA is 330 nm, which shows a considerable red-shift in comparison with that of poly(methylphenylsilylene-co-methylphenylsilylacetylene) (PSI) and alkyl- substituted poly[(disilanylene)acetylenes]. A strong photoluminescence band at 470 nm in THF and 432 nm in benzene can be observed in the visible region, respectively. Treatment of the films of PSA with I 2 vapor afforded conducting films. The conductivity of PSA thin film doped with I 2 was measured to be 0.35 S cm -1 in the air which is lower than that of poly(methyltetraphenylphenylsilylene-co-bis(methylphenylsilyl)phenylene), but higher than that of σ-π polymers without tetraphenylphenyl groups. As an explanation, the tetraphenylphenyl group is a large π-electron-conjugated group; after being introduced to the Si atoms of the polysilanes, the interaction between π-electrons of the tetraphenylphenyl groups and the σ- electrons conjugated along the Si—Si bonds is increased strongly, and the σ-electrons can be conjugated more extensively along the main chain of the polysilanes.展开更多
Milk fat contains a variety of nutritive and health-promoting compounds that guard against some disease. In the current system of global competition, when the quality of milk and milk products is not an option but rat...Milk fat contains a variety of nutritive and health-promoting compounds that guard against some disease. In the current system of global competition, when the quality of milk and milk products is not an option but rather a requirement, therefore, determining the purity of milk fat is critical. This study aims to validate analytical methods for detecting palm oil in a mixture of milk fat and palm oil. Methods of this study was involved detection of non-milk fat in fat blinders by determining the saponification value, iodine number, refractive index, butyro refractometer reading, Gas chromatography, Reverse Phase High-performance liquid chromatography, and Fourier transforms Infrared. The results of this study revealed that the saponification value, Iodine number, refractive index, and Butyro Reading could be used to detect the addition of palm oil by a level of 10% - 20% or more to the milk. The level of some fatty acids in the milk as determined by GC, such as myristic acid (C14:0), palmitic acid (C16:0), and stearic acid (C18:0), is correlated well with the level of adding palm oil to milk fat. The determination of cholesterol and β-sito-sterol content by RP-HPLC could be used for the detection of the addition of palm oil to milk fat. The spectrum behavior produced by FTIR spectroscopy in this adulterated sample is almost the same, so this technique could not be used to detect the palm oil in milk fat.展开更多
文摘This study aims to develop a low-cost refractometer for measuring the sucrose content of fruit juice,which is an important factor affecting human health.While laboratory-grade refractometers are expensive and unsuitable for personal use,existing low-cost commercial options lack stability and accuracy.To address this gap,we propose a refractometer that replaces the expensive CCD sensor and light source with a conventional LED and a reasonably priced CMOS sensor.By analyzing the output waveform pattern of the CMOS sensor,we achieve high precision with a personal-use-appropriate accuracy of 0.1%.We tested the proposed refractometer by conducting 100 repeated measurements on various fruit juice samples,and the results demonstrate its reliability and consistency.Running on a 48 MHz ARM processor,the algorithm can acquire data within 0.2 seconds.Our low-cost refractometer is suitable for personal health management and small-scale production,providing an affordable and reliable method for measuring sucrose concentration in fruit juice.It improves upon the existing low-cost options by offering better stability and accuracy.This accessible tool has potential applications in optimizing the sucrose content of fruit juice for better health and quality control.
文摘IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hours, 7 days and 14 days after birth showed level of IgG 1000 mg/dl. This level indicated that they have good passive transfer of immunity. Also, in this study colostrum quality fed to calves was detected using Brix Refractometer. The colostrum is of high quality as it contains 50 mg/ml of IgG. This Brix refractometer can be used on the farm level to estimate colostrum IgG content and monitoring colostrum feeding practices. Colostrum with high quality IgG could provide calves with enough IgG to attain successful passive transfer of immunity. Brix and Obione refractometers provide simple, rapid method for estimating IgG concentration on calf serum, thus considered to be the most common method for determining passive transfer failure.
基金Supported by the National Key R&D Program of China under Grant No 2018YFF0212300the National Natural Science Foundation of China under Grant No 51575311
文摘To break through the limitations of existing pressure standards, which rely on the gravity and toxic mercury,the national metrological institutes prefer a quantum-based pressure standard. Combining the ideal gas law with helium refractivity measurement, we demonstrate a scheme for the realization of the pressure unit. The refractometer is based on a spectral interferometry with an optical frequency comb and a double-spaced vacuum cell. Through fast Fourier transform of the spectral interferograms of the two beams propagating inside and outside the vacuum cell, the helium refractivity can be obtained with a combined standard uncertainty u(n) of2.9 × 10-9. Moreover, the final u(n) is -8.7 × 10-6 in a measurement range of several megapascals(MPa). Our apparatus is compact, fast(15 ms for one single measurement) and easy to handle. Furthermore, the measurement uncertainty will be improved to-1 × 10-9 or lower if a VIPA-based spectrometer is used. The value of u(p) will thus increase to 3 × 10-6 or better in several MPa.
基金This work was supported by the National Natural Science Foundation of China (Project No. 29974016).
文摘Poly(methyltetraphenylphenylsilylene-co-bis(methylphenylsilyl)acetylene) (PSA) was synthesized by the cocondensation reaction of methyltetraphenylphenyldichlorosilane and bis(chloromethylphenylsilyl)acetylene with sodium in toluene. The PSA thus obtained was soluble in most organic solvents, and its molecular weight was smaller than that of poly[(disilanylene)acetylenes] with alkyl- or aryl-substitution because of the great steric congestion of tetraphenylphenyl groups. The optical and electronic properties of the polymer were investigated. The results show that PSA has strong UV absorption and fluorescence emission, the maximum UV absorption wavelength of PSA is 330 nm, which shows a considerable red-shift in comparison with that of poly(methylphenylsilylene-co-methylphenylsilylacetylene) (PSI) and alkyl- substituted poly[(disilanylene)acetylenes]. A strong photoluminescence band at 470 nm in THF and 432 nm in benzene can be observed in the visible region, respectively. Treatment of the films of PSA with I 2 vapor afforded conducting films. The conductivity of PSA thin film doped with I 2 was measured to be 0.35 S cm -1 in the air which is lower than that of poly(methyltetraphenylphenylsilylene-co-bis(methylphenylsilyl)phenylene), but higher than that of σ-π polymers without tetraphenylphenyl groups. As an explanation, the tetraphenylphenyl group is a large π-electron-conjugated group; after being introduced to the Si atoms of the polysilanes, the interaction between π-electrons of the tetraphenylphenyl groups and the σ- electrons conjugated along the Si—Si bonds is increased strongly, and the σ-electrons can be conjugated more extensively along the main chain of the polysilanes.
文摘Milk fat contains a variety of nutritive and health-promoting compounds that guard against some disease. In the current system of global competition, when the quality of milk and milk products is not an option but rather a requirement, therefore, determining the purity of milk fat is critical. This study aims to validate analytical methods for detecting palm oil in a mixture of milk fat and palm oil. Methods of this study was involved detection of non-milk fat in fat blinders by determining the saponification value, iodine number, refractive index, butyro refractometer reading, Gas chromatography, Reverse Phase High-performance liquid chromatography, and Fourier transforms Infrared. The results of this study revealed that the saponification value, Iodine number, refractive index, and Butyro Reading could be used to detect the addition of palm oil by a level of 10% - 20% or more to the milk. The level of some fatty acids in the milk as determined by GC, such as myristic acid (C14:0), palmitic acid (C16:0), and stearic acid (C18:0), is correlated well with the level of adding palm oil to milk fat. The determination of cholesterol and β-sito-sterol content by RP-HPLC could be used for the detection of the addition of palm oil to milk fat. The spectrum behavior produced by FTIR spectroscopy in this adulterated sample is almost the same, so this technique could not be used to detect the palm oil in milk fat.