期刊文献+
共找到187篇文章
< 1 2 10 >
每页显示 20 50 100
Development of High Accurate Family-use Digital Refractometer Based on CMOS
1
作者 WANG Zhenxing JIA Zhenyuan 《Instrumentation》 2023年第3期12-22,共11页
This study aims to develop a low-cost refractometer for measuring the sucrose content of fruit juice,which is an important factor affecting human health.While laboratory-grade refractometers are expensive and unsuitab... This study aims to develop a low-cost refractometer for measuring the sucrose content of fruit juice,which is an important factor affecting human health.While laboratory-grade refractometers are expensive and unsuitable for personal use,existing low-cost commercial options lack stability and accuracy.To address this gap,we propose a refractometer that replaces the expensive CCD sensor and light source with a conventional LED and a reasonably priced CMOS sensor.By analyzing the output waveform pattern of the CMOS sensor,we achieve high precision with a personal-use-appropriate accuracy of 0.1%.We tested the proposed refractometer by conducting 100 repeated measurements on various fruit juice samples,and the results demonstrate its reliability and consistency.Running on a 48 MHz ARM processor,the algorithm can acquire data within 0.2 seconds.Our low-cost refractometer is suitable for personal health management and small-scale production,providing an affordable and reliable method for measuring sucrose concentration in fruit juice.It improves upon the existing low-cost options by offering better stability and accuracy.This accessible tool has potential applications in optimizing the sucrose content of fruit juice for better health and quality control. 展开更多
关键词 Brix Meter High-precision refractometer OVERSAMPLING 1D CMOS Sensor
下载PDF
Monitoring Passive Transfer of Immunity in Neonatal Calves by Measuring Levels of IgG in Blood Using Immunoassay Method and Refractometer Measures of Serum and Colostrum
2
作者 Osman A. Hameed Hussam Mustafa +1 位作者 Abdul Fatah M. Ahmed Mohamed Khidr Taha 《Open Journal of Veterinary Medicine》 2019年第12期194-201,共8页
IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hour... IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hours, 7 days and 14 days after birth showed level of IgG 1000 mg/dl. This level indicated that they have good passive transfer of immunity. Also, in this study colostrum quality fed to calves was detected using Brix Refractometer. The colostrum is of high quality as it contains 50 mg/ml of IgG. This Brix refractometer can be used on the farm level to estimate colostrum IgG content and monitoring colostrum feeding practices. Colostrum with high quality IgG could provide calves with enough IgG to attain successful passive transfer of immunity. Brix and Obione refractometers provide simple, rapid method for estimating IgG concentration on calf serum, thus considered to be the most common method for determining passive transfer failure. 展开更多
关键词 COLOSTRUM Passive IMMUNITY Immunoglobulin G (IgG) Failure of Transfer IMMUNITY (FTPI) Radial Immunodiffusion (RID) Turbidimetric IMMUNOASSAY (TA) refractometer (REF) BRIX refractometer (Brix) Obione refractometer (Obione) IGG Check Calf IMMUNOASSAY High Quality COLOSTRUM Inadequate Transfer of Passive IMMUNITY (ITPI)
下载PDF
Pascal Realization by Comb-Spectral-Interferometry Based Refractometer
3
作者 杨丽君 李岩 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第10期85-88,共4页
To break through the limitations of existing pressure standards, which rely on the gravity and toxic mercury,the national metrological institutes prefer a quantum-based pressure standard. Combining the ideal gas law w... To break through the limitations of existing pressure standards, which rely on the gravity and toxic mercury,the national metrological institutes prefer a quantum-based pressure standard. Combining the ideal gas law with helium refractivity measurement, we demonstrate a scheme for the realization of the pressure unit. The refractometer is based on a spectral interferometry with an optical frequency comb and a double-spaced vacuum cell. Through fast Fourier transform of the spectral interferograms of the two beams propagating inside and outside the vacuum cell, the helium refractivity can be obtained with a combined standard uncertainty u(n) of2.9 × 10-9. Moreover, the final u(n) is -8.7 × 10-6 in a measurement range of several megapascals(MPa). Our apparatus is compact, fast(15 ms for one single measurement) and easy to handle. Furthermore, the measurement uncertainty will be improved to-1 × 10-9 or lower if a VIPA-based spectrometer is used. The value of u(p) will thus increase to 3 × 10-6 or better in several MPa. 展开更多
关键词 Pascal Realization by Comb-Spectral-Interferometry Based refractometer
下载PDF
阿留申病毒阳性水貂选种简易方法的建立与效果评估
4
作者 张旭 吴晓艳 +5 位作者 曹章 于天浩 赵静 蒋欣芫 孙见 张彦龙 《现代畜牧科技》 2024年第4期46-48,共3页
通过从阿留申病毒阳性水貂筛选具有抵抗力的水貂,达到抗病毒育种的目的。第1年选留种后通过临床观察,把不健康水貂直接淘汰。第2年选种方法,除临床表现不健康的水貂淘汰外,趾尖采血,淘汰血浆比例高于50%以上水貂;第3年,除第2年的方法外... 通过从阿留申病毒阳性水貂筛选具有抵抗力的水貂,达到抗病毒育种的目的。第1年选留种后通过临床观察,把不健康水貂直接淘汰。第2年选种方法,除临床表现不健康的水貂淘汰外,趾尖采血,淘汰血浆比例高于50%以上水貂;第3年,除第2年的方法外,应用血清折光仪测定血浆中总蛋白的值,按35%比例从高往低淘汰。3年时间不同选种方法对比,逐年检测和淘汰,通过红细胞和血浆比例筛查及血清折光仪检测后,水貂产仔数接近阿留申病毒阴性水貂,可以应用此法逐年筛选出抗阿留申病毒的水貂种群,提高产仔数减少农场的损失。 展开更多
关键词 水貂阿留申病 血浆总蛋白 血清折光仪 选种评估
下载PDF
折光仪法在线检测盐酸和氢氧化钠溶液浓度的研究
5
作者 吉桂珍 石文杰 +3 位作者 周冬丽 张苹苹 杨啸 程远欣 《中国食品添加剂》 CAS 2024年第4期284-288,共5页
建立准确测定盐酸溶液和氢氧化钠溶液浓度(以下简称酸液碱液浓度)的折光仪在线方法。通过分析pH计法和折光仪法检测酸液碱液浓度的影响因素,筛选出最佳检测方法-折光仪法;验证了折光仪法检测酸液碱液浓度的准确度、日内日间精密度,研究... 建立准确测定盐酸溶液和氢氧化钠溶液浓度(以下简称酸液碱液浓度)的折光仪在线方法。通过分析pH计法和折光仪法检测酸液碱液浓度的影响因素,筛选出最佳检测方法-折光仪法;验证了折光仪法检测酸液碱液浓度的准确度、日内日间精密度,研究了旁管路安装与主管路角度变化、主管路的流速变化对检测效果的影响,及配置防爆清洗刷对检测效果的影响。结果表明:折光仪法检测结果更稳定,更适合用于酸液碱液浓度检测。检测结果与理论值绝对差值在0.1%以内,日内日间精密度均<6%。以建立的酸液碱液浓度在线检测方法为手段,改进管路配置,结合流量计自动调整流速,实现了酸液碱液浓度的自动调配,且很好的将调配的酸液碱液浓度控制在0.7%~0.9%范围内。 展开更多
关键词 折光仪 在线 氢氧化钠 盐酸 测定 检测
下载PDF
乳品生产过程中折光仪法检测过氧化氢的研究
6
作者 鲍晓凤 赵晶晶 +4 位作者 张春丽 顾春光 杨留岱 张广福 陈娟 《中国乳业》 2024年第5期94-97,104,共5页
[目的]以过氧化氢为对象,收集0%~50%含量过氧化氢用于测试,研究含量、温度、时间3个因素对折光法检测结果的影响,指导日常检测。[方法]鉴于不同浓度的同类物质对光的折射率不同,且浓度变化与折射率变化在一定范围内成反比例关系,双氧水... [目的]以过氧化氢为对象,收集0%~50%含量过氧化氢用于测试,研究含量、温度、时间3个因素对折光法检测结果的影响,指导日常检测。[方法]鉴于不同浓度的同类物质对光的折射率不同,且浓度变化与折射率变化在一定范围内成反比例关系,双氧水折光仪利用这一特性,通过检测样品折射角差异可自动计算待测样品浓度。[结果](1)对同一试样用折光仪法测试,结果离散性小、数据稳定,与国标方法相关性好。(2)不同含量过氧化氢分别用折光仪法和国标方法检测,结果偏差最大0.3%、最小0.0%,样品含量高低对结果准确性无影响。(3)折光仪检测温度需≤35℃,保证样品温度为20~35℃,用折光仪检测能获得准确数值。(4)测试时间超过50 s,检测值会发生变动,建议日常检测控制在50 s内读数。[结论]用折光仪法检测过氧化氢浓度快速准确,操作简单便捷。需注意样品温度和检测时间在操作过程中的影响。 展开更多
关键词 折光仪 过氧化氢 高准确度 易于操作
下载PDF
SYNTHESIS AND OPTICAL-ELECTRONIC PROPERTIES OF POLY[METHYLTETRAPHENYLPHENYLSILYLENE-CO-BIS(METHYLPHENYLSILYL)ACETYLENE]
7
作者 冯圣玉 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2004年第4期321-325,共5页
Poly(methyltetraphenylphenylsilylene-co-bis(methylphenylsilyl)acetylene) (PSA) was synthesized by the cocondensation reaction of methyltetraphenylphenyldichlorosilane and bis(chloromethylphenylsilyl)acetylene with sod... Poly(methyltetraphenylphenylsilylene-co-bis(methylphenylsilyl)acetylene) (PSA) was synthesized by the cocondensation reaction of methyltetraphenylphenyldichlorosilane and bis(chloromethylphenylsilyl)acetylene with sodium in toluene. The PSA thus obtained was soluble in most organic solvents, and its molecular weight was smaller than that of poly[(disilanylene)acetylenes] with alkyl- or aryl-substitution because of the great steric congestion of tetraphenylphenyl groups. The optical and electronic properties of the polymer were investigated. The results show that PSA has strong UV absorption and fluorescence emission, the maximum UV absorption wavelength of PSA is 330 nm, which shows a considerable red-shift in comparison with that of poly(methylphenylsilylene-co-methylphenylsilylacetylene) (PSI) and alkyl- substituted poly[(disilanylene)acetylenes]. A strong photoluminescence band at 470 nm in THF and 432 nm in benzene can be observed in the visible region, respectively. Treatment of the films of PSA with I 2 vapor afforded conducting films. The conductivity of PSA thin film doped with I 2 was measured to be 0.35 S cm -1 in the air which is lower than that of poly(methyltetraphenylphenylsilylene-co-bis(methylphenylsilyl)phenylene), but higher than that of σ-π polymers without tetraphenylphenyl groups. As an explanation, the tetraphenylphenyl group is a large π-electron-conjugated group; after being introduced to the Si atoms of the polysilanes, the interaction between π-electrons of the tetraphenylphenyl groups and the σ- electrons conjugated along the Si—Si bonds is increased strongly, and the σ-electrons can be conjugated more extensively along the main chain of the polysilanes. 展开更多
关键词 POLYSILANE SYNTHESIS Tetraphenylphenyl group optical-electronic properties
下载PDF
多波长合成孔径彩虹折射仪
8
作者 王鑫昊 吴迎春 +1 位作者 徐东炎 吴学成 《实验流体力学》 CAS CSCD 北大核心 2023年第5期34-40,共7页
随着大规模、大尺度试验环境需求的持续增加,测量仪器的应用范围不断扩大。彩虹折射测量技术是一种高效的云雾颗粒测量技术,受成像系统孔径的限制,其测量距离一般在50 cm以下。而合成孔径彩虹折射测量技术利用多个波长的激光照射单个液... 随着大规模、大尺度试验环境需求的持续增加,测量仪器的应用范围不断扩大。彩虹折射测量技术是一种高效的云雾颗粒测量技术,受成像系统孔径的限制,其测量距离一般在50 cm以下。而合成孔径彩虹折射测量技术利用多个波长的激光照射单个液滴产生多个彩虹信号,并将多个彩虹信号合成为一个信号,经反演得到液滴参数,可以实现超远距离液滴参数测量,将测量距离增大至1.5 m左右。为满足从大型喷雾场外部测量内部液滴参数的需求,研发了多波长合成孔径彩虹折射仪。通过模拟,验证了多波长合成孔径彩虹折射仪能够实现远距离液滴测量;通过测量不同粒径的水滴和乙醇液滴,证明了多波长合成孔径彩虹折射仪运行的可行性和准确性。粒径和折射率测量误差分别在5μm和8×10^(-4)以内(水滴和乙醇液滴粒径范围为100~200μm)。多波长合成孔径彩虹折射仪可以突破孔径限制,拓展工业应用场景,实现液滴粒径、折射率等多参数同时在线测量。 展开更多
关键词 液滴 粒径 多波长 折射率 彩虹折射仪 合成孔径
下载PDF
Validation of the Methods for Detection the Non-Milk Fat in a Mixture of Milk Fat and Palm Oil
9
作者 Marwa El-Nabawy Sameh Awad Amel Ibrahim 《Food and Nutrition Sciences》 CAS 2023年第1期1-17,共17页
Milk fat contains a variety of nutritive and health-promoting compounds that guard against some disease. In the current system of global competition, when the quality of milk and milk products is not an option but rat... Milk fat contains a variety of nutritive and health-promoting compounds that guard against some disease. In the current system of global competition, when the quality of milk and milk products is not an option but rather a requirement, therefore, determining the purity of milk fat is critical. This study aims to validate analytical methods for detecting palm oil in a mixture of milk fat and palm oil. Methods of this study was involved detection of non-milk fat in fat blinders by determining the saponification value, iodine number, refractive index, butyro refractometer reading, Gas chromatography, Reverse Phase High-performance liquid chromatography, and Fourier transforms Infrared. The results of this study revealed that the saponification value, Iodine number, refractive index, and Butyro Reading could be used to detect the addition of palm oil by a level of 10% - 20% or more to the milk. The level of some fatty acids in the milk as determined by GC, such as myristic acid (C14:0), palmitic acid (C16:0), and stearic acid (C18:0), is correlated well with the level of adding palm oil to milk fat. The determination of cholesterol and β-sito-sterol content by RP-HPLC could be used for the detection of the addition of palm oil to milk fat. The spectrum behavior produced by FTIR spectroscopy in this adulterated sample is almost the same, so this technique could not be used to detect the palm oil in milk fat. 展开更多
关键词 Milk Fat Palm Oil ADULTERATION Butyro refractometer Reading GC RP-HPLC FTIR
下载PDF
采用阿贝折射仪快速测定四水合酒石酸钾钠的纯度 被引量:1
10
作者 申能美 《安徽化工》 CAS 2023年第2期134-136,共3页
研究了一种采用阿贝折射仪快速测定四水合酒石酸钾钠纯度的方法。先采用去离子水溶解四水合酒石酸钾钠,配制成一定浓度的溶液,再采用阿贝折射仪进行检测,方法相对标准偏差小于0.3%,样品的回收率在95.6%~101.0%之间。结果表明,方法准确度... 研究了一种采用阿贝折射仪快速测定四水合酒石酸钾钠纯度的方法。先采用去离子水溶解四水合酒石酸钾钠,配制成一定浓度的溶液,再采用阿贝折射仪进行检测,方法相对标准偏差小于0.3%,样品的回收率在95.6%~101.0%之间。结果表明,方法准确度高,重复性好,此外,溶剂消耗量少,分析时间短,简单易行,能够满足定量分析要求。 展开更多
关键词 阿贝折射仪 四水合酒石酸钾钠 纯度
下载PDF
折光法快速测定偏光片延伸液的硼酸含量
11
作者 李铭全 周文贤 +1 位作者 邓崇浩 王颖 《广东化工》 CAS 2023年第22期130-132,共3页
偏光片作为显示行业的上游关键材料之一,其生产过程中的延伸液硼酸浓度,直接影响着偏光片的耐候、光学性能,硼酸浓度的波动直接影响产品的品质稳定性。利用折光仪法测定延伸液的硼酸含量。结果表明,折光法检测延伸液硼酸质量分数在0.5%~... 偏光片作为显示行业的上游关键材料之一,其生产过程中的延伸液硼酸浓度,直接影响着偏光片的耐候、光学性能,硼酸浓度的波动直接影响产品的品质稳定性。利用折光仪法测定延伸液的硼酸含量。结果表明,折光法检测延伸液硼酸质量分数在0.5%~4.5%范围内,与折射率有良好的线性关系,R^(2)为0.9998,相对误差<1%。该方法灵敏、简单、准确、重复性好,可用于延伸液硼酸质量分数监控,满足在线自动检测、调整浓度,实现智能化、数字化生产管理。 展开更多
关键词 偏光片 硼酸 折光仪 糖度仪 检测方法
下载PDF
电脑自动验光联合综合验光仪在屈光不正中的诊断价值与应用效果
12
作者 李奇蒙 《智慧健康》 2023年第13期56-59,共4页
目的 分析在屈光不正患者验光检查过程中采用电脑自动验光联合综合验光仪对其诊断价值与应用效果。方法 选取本院2022年11月-2023年2月诊治的不同程度屈光不正患者60例。所有患者均行电脑自动验光及综合验光仪验光。分析比较单纯电脑自... 目的 分析在屈光不正患者验光检查过程中采用电脑自动验光联合综合验光仪对其诊断价值与应用效果。方法 选取本院2022年11月-2023年2月诊治的不同程度屈光不正患者60例。所有患者均行电脑自动验光及综合验光仪验光。分析比较单纯电脑自动验光与电脑自动验光联合验光综合仪联合验光方式对患者屈光不正检出率、球镜、柱镜及散光轴位检测结果的相差范围。结果 与单独采用电脑自动验光相比,电脑自动验光联合综合验光仪联合验光检测率增高,球镜屈光度值降低,差异具有统计学意义(P<0.05);柱镜屈光度值、散光轴位无明显差别,差异无统计学意义(P>0.05)。结论 在所有屈光不正患者中采用电脑自动验光联合综合验光仪进行检测可提高其检出率同时获得更精准的检测效果。 展开更多
关键词 屈光不正 电脑自动验光 综合验光仪 验光
下载PDF
眼镜制配场所现状及问题分析
13
作者 高改丽 林俊辉 《品牌与标准化》 2023年第4期59-61,共3页
根据国家相关规定,眼镜制配场所需要配备与该店销售、经营业务相适应的计量检测设备,如验光仪、焦度计、验光镜片箱、角膜曲率计等。这些设备属于国家规定的强制检定计量器具,需要按时备案、及时检定。本文阐述了眼镜制配场所计量器具... 根据国家相关规定,眼镜制配场所需要配备与该店销售、经营业务相适应的计量检测设备,如验光仪、焦度计、验光镜片箱、角膜曲率计等。这些设备属于国家规定的强制检定计量器具,需要按时备案、及时检定。本文阐述了眼镜制配场所计量器具的分布情况、受检率、合格率,以及检定过程中存在的主要问题,提出了解决措施,并对优秀案例进行归纳总结,方便大家参阅。 展开更多
关键词 验光仪 焦度计 验光镜片箱 检定
下载PDF
近海面大气波导探测及与其它研究结果的比较 被引量:37
14
作者 蔺发军 刘成国 潘中伟 《电波科学学报》 EI CSCD 2002年第3期269-272,281,共5页
大气波导环境对雷达系统和通信系统有很大的影响 ,而对于高度较低、出现频繁的海上蒸发波导来说 ,如何快速、准确地获得它的波导参数是一个重要的问题。用微波折射率仪进行近海面大气波导尤其是贴海蒸发波导的测量在国内属首次 ,通过现... 大气波导环境对雷达系统和通信系统有很大的影响 ,而对于高度较低、出现频繁的海上蒸发波导来说 ,如何快速、准确地获得它的波导参数是一个重要的问题。用微波折射率仪进行近海面大气波导尤其是贴海蒸发波导的测量在国内属首次 ,通过现场试验结果与理论估算结果的比较 。 展开更多
关键词 海面 大气波导 探测 微波折射率仪 蒸发波导 测量 超视距探测
下载PDF
北京市海淀区学龄前儿童视力及屈光状态的调查 被引量:40
15
作者 冯晶晶 李亚平 +2 位作者 陈巍 李晓慧 李冬 《国际眼科杂志》 CAS 2010年第2期373-375,共3页
目的:了解北京市海淀区学龄前儿童视力及屈光状态,为防治屈光不正提供依据。方法:采取整群随机抽样方法抽取10所幼儿园2776例3~6岁儿童,应用儿童图形视力表和标准对数视力表检查视力;应用美国伟伦Suresight手持自动验光仪进行屈光检查... 目的:了解北京市海淀区学龄前儿童视力及屈光状态,为防治屈光不正提供依据。方法:采取整群随机抽样方法抽取10所幼儿园2776例3~6岁儿童,应用儿童图形视力表和标准对数视力表检查视力;应用美国伟伦Suresight手持自动验光仪进行屈光检查。结果:学龄前儿童视力低常率为12.64%,随着年龄增长,视力低常率增高,5岁最高,6岁又稍有下降。视力正常眼的屈光状态以远视和散光为主,且均以轻度为主。中度远视和>1.50D的散光分别占1.79%和3.61%。视力低常眼中近视(3.18%)、中度远视(4.49%)、>1.50D的散光(22.47%)和混合散光(11.05%)所占的比例增多。结论:学龄前儿童视力及屈光是儿童眼保健的重要指标,了解各年龄视力及屈光状况非常必要,可以发现潜在问题,预测发展趋势,为早期干预提供依据。 展开更多
关键词 学龄前儿童 屈光 手持自动验光仪
下载PDF
折光法监测水溶性糖效果的研究 被引量:6
16
作者 霍光华 高荫榆 +1 位作者 何小立 刘勇 《南昌大学学报(理科版)》 CAS 北大核心 2002年第2期128-131,共4页
为了确立折光法在植物水溶性糖研究中的监控效果 ,将折光法与经典测糖法硫酸—苯酚法、硫酸—蒽酮法比较 ,考察其在各类纯糖溶液 ,以及在植物多糖提取工艺上的应用 ,并对三种方法彼此间进行了相关性分析等。表明 :折光法测定纯糖溶液优... 为了确立折光法在植物水溶性糖研究中的监控效果 ,将折光法与经典测糖法硫酸—苯酚法、硫酸—蒽酮法比较 ,考察其在各类纯糖溶液 ,以及在植物多糖提取工艺上的应用 ,并对三种方法彼此间进行了相关性分析等。表明 :折光法测定纯糖溶液优于两种经典法 (糖衍生法 ) ,测定植物多糖水提液 ,糖含量与折射指数值间存在着相关性 ,在工艺监测中起到与经典法较为一致的监控作用。折光法可用于糖类植物资源的初筛 ,水提工艺监控 ,样品糖浓度的估计等。该法省时 ,节约 。 展开更多
关键词 折光法 折射计 植物水溶性糖 含量测定 提取工艺 工艺监测 糖衍生法
下载PDF
烟草叶片中自由水含量测定方法比较分析 被引量:18
17
作者 王传义 张忠锋 +7 位作者 徐秀红 孙福山 王浩雅 王爱华 王松峰 王晓宾 谭青涛 黄传华 《中国烟草科学》 CSCD 2008年第3期29-31,共3页
比较分析了烟草叶片中自由水含量测定的两种方法—阿贝折射仪法和称重法。结果表明,两种方法测定结果差异不显著。其中,称重法测定的变异幅度和相对变异程度较小,其测定结果代表性更好。确定了称重法和阿贝折射仪法适宜的加糖液量和浸... 比较分析了烟草叶片中自由水含量测定的两种方法—阿贝折射仪法和称重法。结果表明,两种方法测定结果差异不显著。其中,称重法测定的变异幅度和相对变异程度较小,其测定结果代表性更好。确定了称重法和阿贝折射仪法适宜的加糖液量和浸泡时间,两种方法均以加入烟草叶片质量6倍以上的蔗糖溶液并浸泡6h以上处理比较理想。 展开更多
关键词 烟叶 自由水 阿贝折射仪法 称重法
下载PDF
高效液相色谱法测定灵芝多糖含量 被引量:21
18
作者 韩振泰 赵玉娟 +1 位作者 刘惠文 李如华 《中国农业科技导报》 CAS CSCD 2009年第S1期65-67,共3页
建立了高效液相色谱法测定灵芝多糖含量的方法,采用糖专用分析柱,以104分子量的葡聚糖为标准,流动相为水,流速0.6 mL/min,检测器为示差检测器,柱温为70℃,检测限为0.03 g/L,线性方程为Y=109 779.6X-903.3相关系数r=0.999 9,方法回收率为... 建立了高效液相色谱法测定灵芝多糖含量的方法,采用糖专用分析柱,以104分子量的葡聚糖为标准,流动相为水,流速0.6 mL/min,检测器为示差检测器,柱温为70℃,检测限为0.03 g/L,线性方程为Y=109 779.6X-903.3相关系数r=0.999 9,方法回收率为98%~104%,相对标准偏差为RSD%=0.12(n=6)。该方法简易、稳定,适合灵芝多糖的测定。 展开更多
关键词 高效液相色谱 示差检测器 灵芝 多糖
下载PDF
精确测量大气折射率的微波折射率仪 被引量:9
19
作者 张瑜 师帅涛 《海军工程大学学报》 CAS 北大核心 2009年第4期26-29,共4页
根据微波谐振腔的谐振频率随充入介质不同而变化的原理,研制出了一种能够精确测量大气折射率的微波折射率仪。实验证实,该微波折射率仪的测量精度远远高于常用五九型探空仪和轻型电容式折射率仪,且具有反应速度快、精度高、体积小、重... 根据微波谐振腔的谐振频率随充入介质不同而变化的原理,研制出了一种能够精确测量大气折射率的微波折射率仪。实验证实,该微波折射率仪的测量精度远远高于常用五九型探空仪和轻型电容式折射率仪,且具有反应速度快、精度高、体积小、重量轻等特点。该仪器不仅可实用于高精度雷达电波折射误差修正,也可实用于大气波导的精确测量和大气精细结构的精确测量等方面。 展开更多
关键词 雷达 大气折射率 微波折射率仪
下载PDF
电脑验光仪、IOL Master、Lenster LS900测量角膜曲率的对比分析 被引量:4
20
作者 唐秀侠 买志彬 +2 位作者 聂晓丽 刘苏冰 江红玲 《眼科新进展》 CAS 北大核心 2014年第11期1081-1082,共2页
目的比较电脑验光仪、IOL Master、Lenstar LS900三种仪器测量角膜曲率的差异性,并为临床提供数据参考。方法利用三种不同测量仪器对86例(172眼)患者测量垂直与水平角膜曲率,每种仪器每眼分别测量三次,由专人负责测量,记录其平均值。结... 目的比较电脑验光仪、IOL Master、Lenstar LS900三种仪器测量角膜曲率的差异性,并为临床提供数据参考。方法利用三种不同测量仪器对86例(172眼)患者测量垂直与水平角膜曲率,每种仪器每眼分别测量三次,由专人负责测量,记录其平均值。结果电脑验光仪测得垂直曲率为(43.85±1.74)D、水平曲率为(43.08±1.39)D,IOL Master测得垂直曲率为(44.08±2.78)D、水平曲率为(42.92±1.43)D,Lenstar LS900测得垂直曲率为(43.91±1.69)D,水平曲率为(42.94±1.41)D。三者测出的结果差异无统计学意义(P>0.05)。结论通过对同一人群不同仪器测量角膜曲率的结果进行分析显示,三种仪器测量出的角膜曲率数据均准确可靠,一致性较好,可以相互替代使用。 展开更多
关键词 电脑验光仪 IOL MASTER LENSTAR LS900 角膜曲率
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部