期刊文献+
共找到716篇文章
< 1 2 36 >
每页显示 20 50 100
Collisional broadening of some 2~1Δ_g←B^1Π_u lines in Na_2 molecules by optical-optical double resonance spectroscopy 被引量:2
1
作者 刘静 戴康 沈异凡 《Chinese Optics Letters》 SCIE EI CAS CSCD 2006年第7期376-378,共3页
Using the optical-optical double resonance (OODR) technique, we have studied the collisional broadening of some 21△g←B1πu lines in Na2 molecules. A single line Ar+ laser is used to pump the sodium dimers from t... Using the optical-optical double resonance (OODR) technique, we have studied the collisional broadening of some 21△g←B1πu lines in Na2 molecules. A single line Ar+ laser is used to pump the sodium dimers from thermally populated ground state X^1∑^+g level to the intermediate B1πu state. Then, a single-mode diode laser is used to probe the doubly excited 21△g state. The broadening rate coefficient is determined from the slope of the total linewidth versus Ne density curve. We obtain the average value kbr = (1.1 ± 0.5)×10^-8 cm^3 8^-1. The collisional excitation transfer between rotational levels of the B1πu state (i.e.,B1πu(2,83/84) ←B1Ⅱu (2,82)) is also investigated. The rates can be determined from the relative intensities of the main peak and satellite lines, combined with a rate equation model. The rates of 1.25 × 106 and 1.07 × 106 s^-1 are obtained, respectively. 展开更多
关键词 Na Collisional broadening of some 2~1 u lines in Na2 molecules by optical-optical double resonance spectroscopy B~1
原文传递
Magnetic resonance imaging-based deep learning model to predict multiple firings in double-stapled colorectal anastomosis 被引量:3
2
作者 Zheng-Hao Cai Qun Zhang +7 位作者 Zhan-Wei Fu Abraham Fingerhut Jing-Wen Tan Lu Zang Feng Dong Shu-Chun Li Shi-Lin Wang Jun-Jun Ma 《World Journal of Gastroenterology》 SCIE CAS 2023年第3期536-548,共13页
BACKGROUND Multiple linear stapler firings during double stapling technique(DST)after laparoscopic low anterior resection(LAR)are associated with an increased risk of anastomotic leakage(AL).However,it is difficult to... BACKGROUND Multiple linear stapler firings during double stapling technique(DST)after laparoscopic low anterior resection(LAR)are associated with an increased risk of anastomotic leakage(AL).However,it is difficult to predict preoperatively the need for multiple linear stapler cartridges during DST anastomosis.AIM To develop a deep learning model to predict multiple firings during DST anastomosis based on pelvic magnetic resonance imaging(MRI).METHODS We collected 9476 MR images from 328 mid-low rectal cancer patients undergoing LAR with DST anastomosis,which were randomly divided into a training set(n=260)and testing set(n=68).Binary logistic regression was adopted to create a clinical model using six factors.The sequence of fast spin-echo T2-weighted MRI of the entire pelvis was segmented and analyzed.Pure-image and clinical-image integrated deep learning models were constructed using the mask region-based convolutional neural network segmentation tool and three-dimensional convolutional networks.Sensitivity,specificity,accuracy,positive predictive value(PPV),and area under the receiver operating characteristic curve(AUC)was calculated for each model.RESULTS The prevalence of≥3 linear stapler cartridges was 17.7%(58/328).The prevalence of AL was statistically significantly higher in patients with≥3 cartridges compared to those with≤2 cartridges(25.0%vs 11.8%,P=0.018).Preoperative carcinoembryonic antigen level>5 ng/mL(OR=2.11,95%CI 1.08-4.12,P=0.028)and tumor size≥5 cm(OR=3.57,95%CI 1.61-7.89,P=0.002)were recognized as independent risk factors for use of≥3 linear stapler cartridges.Diagnostic performance was better with the integrated model(accuracy=94.1%,PPV=87.5%,and AUC=0.88)compared with the clinical model(accuracy=86.7%,PPV=38.9%,and AUC=0.72)and the image model(accuracy=91.2%,PPV=83.3%,and AUC=0.81).CONCLUSION MRI-based deep learning model can predict the use of≥3 linear stapler cartridges during DST anastomosis in laparoscopic LAR surgery.This model might help determine the best anastomosis strategy by avoiding DST when there is a high probability of the need for≥3 linear stapler cartridges. 展开更多
关键词 Deep learning Image-reading artificial intelligence Magnetic resonance imaging Predictive model double stapling technique Linear stapler Rectal cancer Laparoscopic surgery Low anterior resection Anastomotic leakage
下载PDF
Performance characteristics of an energy selective electron refrigerator with double resonances 被引量:9
3
作者 王小敏 何济洲 唐威 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第3期984-991,共8页
This paper establishes the energy selective electron (ESE) engine with double resonances as a refrigerator in one dimensional (1D) system. It consists of two infinitely large electron reservoirs with different tem... This paper establishes the energy selective electron (ESE) engine with double resonances as a refrigerator in one dimensional (1D) system. It consists of two infinitely large electron reservoirs with different temperatures and chemical potentials, and they are perfectly thermally insulated from each other and interaction only via a double 'idealized energy filter' whose widths are all finite. Taking advantage of the density of state and Fermi distribution in the 1D system, the heat flux into each reservoir may then be calculated. Moreover, the coefficient of performance may be derived from the expressions for the heat flux into the hot and cold reservoirs. The performance characteristic curves are plotted by numerical analysis. The influences of the resonances widths, the energy position of resonance and the space of two resonances on performance of the ESE refrigerator are discussed. The results obtained here have theoretical significance for the understanding of thermodynamic performance of the micro-nano devices. 展开更多
关键词 electron transport double resonances ESE refrigerator performance parameter
下载PDF
Quantum fluctuations of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling 被引量:12
4
作者 徐兴磊 李洪奇 王继锁 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第8期2462-2470,共9页
Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is propo... Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is proposed. The quantum fluctuations of charge and current of each loop in a squeezed vacuum state are studied in the thermal excitation case. It is shown that the fluctuations not only depend on circuit inherent parameters, but also rely on excitation quantum number and squeezing parameter. Moreover, due to the finite environmental temperature and damped resistance, the fluctuations increase with the temperature rising, and decay with time. 展开更多
关键词 mesoscopic double resonance RLC circuit linear transformation thermal excitation state quantum fluctuation
下载PDF
Entropic noise induced stability and double entropic stochastic resonance induced by correlated noises 被引量:2
5
作者 曾春华 王华 王辉涛 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第5期146-152,共7页
For the activated dynamics of a Brownian particle moving in a confined system with the presence of entropic barriers, this paper investigates a periodic driving and correlations between two noises. Within the two-stat... For the activated dynamics of a Brownian particle moving in a confined system with the presence of entropic barriers, this paper investigates a periodic driving and correlations between two noises. Within the two-state approximation, the explicit expressions of the mean first passage time (MFPT) and the spectral power amplification (SPA) axe obtained, respectively. Based on the numerical computations, it is found that: (i) The MFPT as a function of the noise intensity exhibits a maximum with the positive correlations between two noises (λ〉0), this maximum for MFPT shows the characteristic of the entropic noise induced stability (ENIS) effect. The intensity A of correlations between two noises can enhance the ENIS effect. (ii) The SPA as a function of the noise intensity exhibits a double-peak by tuning the noise correlation intensity λ, i.e., the existence of a double-peak behaviour is the identifying characteristic of the double entropic stochastic resonance phenomenon. 展开更多
关键词 correlated noises confined system entropic noise induced stability double entropic stochastic resonance ]
下载PDF
Effect of cyclotron resonance on ‘hot’ dispersion in a staggered double metallic grating sheet beam travelling wave tube 被引量:1
6
作者 Jing WANG Yu FAN +3 位作者 Chen YANG Ding ZHAO Gang WANG Jirun LUO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第8期89-96,共8页
Based on the beam wave synchronous interaction in transverse and longitudinal directions at the same time and starting from Maxwell’s equation and linear Vlasov equation, the beam–wave interaction ‘hot’ dispersion... Based on the beam wave synchronous interaction in transverse and longitudinal directions at the same time and starting from Maxwell’s equation and linear Vlasov equation, the beam–wave interaction ‘hot’ dispersion equation considering both cyclotron resonance and Cherenkov resonance in a staggered double metallic grating traveling wave tube is deduced.Through the reasonable selection for geometric and electrical parameters, the numerical calculation and analysis of the ‘hot’ dispersion equation shows that the beam–wave interaction gain and frequency band with the cyclotron resonance enhancement effect are higher than those with only Cherenkov resonance radiation. 展开更多
关键词 staggered double METALLIC GRATING SHEET BEAM travelling wave TUBE cyclotron resonance Cherenkov effects gain
下载PDF
Start-Up Acceleration of Quartz Crystal Oscillator Using Active Inductance Double Resonance and Embedded Triggering Circuit 被引量:1
7
作者 Tomio Sato Akira Kudo Tetsuya Akitsu 《Journal of Sensor Technology》 2015年第1期15-27,共13页
Low-frequency double-resonance quartz crystal oscillator was developed with active inductance circuit aiming the start-up of stable oscillation of tuning fork-type quartz crystal resonator at 32.768 kHz within 0.37 ms... Low-frequency double-resonance quartz crystal oscillator was developed with active inductance circuit aiming the start-up of stable oscillation of tuning fork-type quartz crystal resonator at 32.768 kHz within 0.37 ms. The initial oscillation is triggered by a part of crystal oscillator forming a CR oscillator. The negative resistance ranges to 4 MΩ at gmf of 4.1 μA/V. In a limited frequency range, the circuit shows negative reactance Ccci = -3.4 pF equivalent to inductance Lcc = 9.8 H. The Allan standard deviation indicated 10-11 to 10-10, showing high stability comparable to general quartz crystal oscillator. 展开更多
关键词 double resonance QUARTZ Crystal OSCILLATOR ACTIVE INDUCTANCE
下载PDF
Resonance analysis of single DOF parameter-varying system of magnetic-liquid double suspension bearing 被引量:1
8
作者 ZHAO Jianhua ZHAO Yabin +4 位作者 ZHANG Xuze WANG Jin WANG Ziqi GAO Dianrong DU Guojun 《High Technology Letters》 EI CAS 2022年第1期72-79,共8页
Magnetic-liquid double suspension bearing(MLDSB)is mainly supported by electromagnetic suspension and supplemented by hydrostatic supporting.Its bearing capacity and stiffness can be greatly improved,and then it is su... Magnetic-liquid double suspension bearing(MLDSB)is mainly supported by electromagnetic suspension and supplemented by hydrostatic supporting.Its bearing capacity and stiffness can be greatly improved,and then it is suitable for the occasions of medium speed,heavy load.When the bearing system is excited by periodic force,the flow q and current i regulated by the double-closed-loop control mechanism change periodically.Then the risk of parametric resonance in MLDSB is greatly aggravated by the change of the parameter system,which seriously affects its operation stabil-ity and reliability.Therefore,this paper intends to study the resonance characteristics of the parame-ter system of MLDSB.Firstly,Marshall-Duffing equation of the parametric system is established by taking the flow q and the current i as variables respectively.Then,by using the asymptotic method,the occurrence condition and variation rule of the principal,1/2 Harmonic and 1/3 Harmonic para-metric resonance are solved.The results show that only the 1/2 Harmonic resonance of the flow q parameter varying system occurs accompanied by the resonance condition of high frequency.The principal,1/2 Harmonic and 1/3 Harmonic parametric resonance of the current i occur accompanied by the resonance condition of high frequency.And the 1/2 Harmonic resonance of the current i oc-curs accompanied by the non-single value bifurcation and dynamic bifurcation.The paper can pro-vide theoretical reference for the parameter design and stable operation of MLDSB. 展开更多
关键词 magnetic-liquid double suspension bearing(MLDSB) resonance analysis flow parameter varying system current parameter varying system
下载PDF
THE DOUBLE RESONANCES OF MAGNETISM AND SOLID COUPLING OF HYDROELECTRIC-GENERATOR STATOR SYSTEM
9
作者 李文兰 邱家俊 杨志安 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2000年第10期1187-1196,共10页
A double-shell model of hydroelectric-generator stator system was established. Applying the theory of mechano-electric analytical dynamics theory, the nonlinear vibration equation of magnetism and solid coupling of hy... A double-shell model of hydroelectric-generator stator system was established. Applying the theory of mechano-electric analytical dynamics theory, the nonlinear vibration equation of magnetism and solid coupling of hydroelectric-generator stator system, under steadily balanced three-phases operating condition, was obtained. According to the method of multiple scales for nonlinear oscillations, the double resonances of magnetism and solid coupling of hydroelectric-generator stater system, were investigated. It is pointed out that the system has abundant dynamics phenomenon including the attendant jumps and coexistence of multiple stable motions. 展开更多
关键词 hydroelectric-generator stator system method of the multiple scales magnetism and solid coupling double resonances
下载PDF
Compatibility of the Active Inductance Double Resonance Quartz Oscillator with Q-MEMS Temperature Sensor
10
作者 Tetsuya Akitsu Akira Kudo Tomio Sato 《Engineering(科研)》 2015年第2期47-57,共11页
Low-frequency double-resonance quartz crystal oscillator circuit was developed with active inductance aiming the quick start-up in the intermittent operation on the sensor circuit and DC isolation using a Q-MEMS sensi... Low-frequency double-resonance quartz crystal oscillator circuit was developed with active inductance aiming the quick start-up in the intermittent operation on the sensor circuit and DC isolation using a Q-MEMS sensing crystal HTS-206. Allan standard deviation indicated 5 × 10–12, showing short range stability of the sensor circuit sufficient for the ubiquitous environmental sen sor network. 展开更多
关键词 Q-MEMS Sensing Crystal HTS-206 Active INDUCTANCE double resonance
下载PDF
Experimental Study on Double Resonance Optical Pumping Spectroscopy in a Ladder-Type System of ^(87)Rb Atoms
11
作者 Yi-Hong Li Shao-Hua Li +3 位作者 Bin-Peng Ynan Li-Rong Wang Lian-Tuan Xiao Suo-Tang Jia 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第9期33-36,共4页
Double resonance optical pumping spectroscopy has an outstanding advantage of high signal-to-noise ratio, thus having potential applications in precision measurement. With the counter propagated 780nm and 776nm laser ... Double resonance optical pumping spectroscopy has an outstanding advantage of high signal-to-noise ratio, thus having potential applications in precision measurement. With the counter propagated 780nm and 776nm laser beams acting on a rubidium vapor cell, the high resolution spectrum of 5S1/2 - 5P3/2 - 5D5/2 ladder-type transition of ST Rb atoms is obtained by monitoring the population of the 5S1/2 ground state. The dependence of the spectroscopy lineshape on the probe and coupling fields are comprehensively studied in theory and experiment. This research is helpful for measurement of fundamental physical constants by high resolution spectroscopy. 展开更多
关键词 Experimental Study on double resonance Optical Pumping Spectroscopy in a Ladder-Type System of Rb Atoms
下载PDF
Realization of double resonance for a bright frequencytunable source of narrowband entangled photons
12
作者 杨剑 赵天明 +3 位作者 张涵 杨涛 包小辉 潘建伟 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期235-238,共4页
In this paper, we report an interesting phenomenon when precisely adjust the tuning crystal for double-resonance of a type-II configured parametric amplifier cavity, which is later verified as a cavity-enhanced effect... In this paper, we report an interesting phenomenon when precisely adjust the tuning crystal for double-resonance of a type-II configured parametric amplifier cavity, which is later verified as a cavity-enhanced effect in optics alignment. The theoretical result indicates that an angle accuracy error within 0.09° is necessary to achieve a high contrast ratio of 100:1 for a cavity with a finesse of about 205, which is crucial but high-demanding to get a high-quality narrowband entanglement source. Meanwhile, we figure out a method to release such a high requirement and get high visibility in a moderate-accuracy alignment. 展开更多
关键词 optics alignment double-resonance cavity-enhanced narrowband entanglement
下载PDF
Endovascular Application of Magnetic Resonance Double Mismatch Technique for Acute Anterior Circulation Large Vessel Occlusion with Cerebral Infarction in an Unknown Time Window
13
作者 Xiangkong Song Qing Zhang +2 位作者 Lilin Gao Jie Qi Guoqing Wang 《Journal of Clinical and Nursing Research》 2020年第5期43-46,共4页
Objective:To investigate the clinical effects of applying the magnetic resonance double mismatch technique to endovascular treatment of acute anterior circulation,large vessel occlusion with cerebral infarction in an ... Objective:To investigate the clinical effects of applying the magnetic resonance double mismatch technique to endovascular treatment of acute anterior circulation,large vessel occlusion with cerebral infarction in an unknown time window.Methods:The research work was carried out in our hospital,the work was carried out from November 2018 to November 2019,the patients with acute anterior circulation large vessel occlusion with cerebral infarction who were treated in our hospital during this period,100 patients,50 patients with an unknown time window and 50 patients with definite time window were selected,and they were named as the experimental and control groups,given different examination methods,were given to investigate the clinical treatment effect.Results:Patients’data on HIHSS score before treatment,the incidence of intracranial hemorrhage and rate of Mrs≤2 rating after 90 days of treatment were not significantly different(P>0.05),which was not meaningful.The differences in data between the two groups concerning HIHSS scores were relatively significant before,and after treatment(P<0.05).Conclusion:The magnetic resonance double mismatch technique will be applied in the endovascular treatment of acute anterior circulation large vessel occlusion with cerebral infarction of unknown time window. 展开更多
关键词 Magnetic resonance double mismatch technique Unknown time window Acute anterior circulation large vessel occlusion with cerebral infarction Therapeutic effect
下载PDF
Double-resonance optical-pumping effect and laddertype electromagnetically induced transparency signal without Doppler background in cesium atomic vapour cell
14
作者 杨保东 高静 +3 位作者 梁强兵 王杰 张天才 王军民 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第4期310-315,共6页
In a Doppler-broadened ladder-type cesium atomic system (6S1/2 6P3/2-8S1/2), this paper characterizes electro- magnetically induced transparency (EIT) in two different experimental arrangements, and investigates t... In a Doppler-broadened ladder-type cesium atomic system (6S1/2 6P3/2-8S1/2), this paper characterizes electro- magnetically induced transparency (EIT) in two different experimental arrangements, and investigates the influence of the double-resonance optical-pumping (DROP) effect on EIT in both arrangements. When the probe laser is weak, DROP is explicitly suppressed. When the probe laser is moderate, population of the intermediate level (6P3/2 FI = 5) is remarkable, therefore DROP is mixed with EIT. An interesting bimodal spectrum with the broad component due to DROP and the narrow part due to EIT has been clearly observed in cesium 6S1/2 F = 4-6P3/2 F^1= 5-8S1/2 F^11 = 4 transitions. 展开更多
关键词 electromagnetically induced transparency double-resonance optical pumping laser spectroscopy
下载PDF
Off-resonant double-resonance optical-pumping spectra and their application in a multiphoton cesium magneto-optical trap
15
作者 杨保东 何军 王军民 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第5期296-301,共6页
We present an investigation of double-resonance optical pumping (DROP) spectra under the condition of single-photon frequency detuning based on a cesium 6S1/2-6P3/2-8S1/2 ladder-type system with a room-temperature v... We present an investigation of double-resonance optical pumping (DROP) spectra under the condition of single-photon frequency detuning based on a cesium 6S1/2-6P3/2-8S1/2 ladder-type system with a room-temperature vapor cell. Two DROP peaks are found, and their origins are explored. One peak has a narrow linewidth due to the atomic coherence for a counterpropagating configuration; the other peak has a broad linewidth, owing to the spontaneous decay for a coprop-agating configuration. This kind of off-resonant DROP spectrum can be used to control and offset-lock a laser frequency to a transition between excited states. We apply this technique to a multiphoton cesium magneto-optical trap, which can efficiently trap atoms on both red and blue sides of the two-photon resonance. 展开更多
关键词 double-resonance optical pumping electromagnetically induced transparency two-color lasercooling laser spectroscopy
下载PDF
Observation of intermolecular double-quantum coherence signal dips in nuclear magnetic resonance
16
作者 沈桂平 蔡聪波 +1 位作者 蔡淑惠 陈忠 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第10期190-197,共8页
The correlated spectroscopy revamped by asymmetric Z-gradient echo detection (CRAZED) sequence is modified to investigate intermolecular double-quantum coherence nuclear magnetic resonance signal dips in highly pola... The correlated spectroscopy revamped by asymmetric Z-gradient echo detection (CRAZED) sequence is modified to investigate intermolecular double-quantum coherence nuclear magnetic resonance signal dips in highly polarized spin systems. It is found that the occurrence of intermolecular double-quantum coherence signal dips is related to sample geometry, field inhomogeneity and dipolar correlation distance. If the field inhomogeneity is refocused, the signal dip occurs at a fixed position whenever the dipolar correlation distance approaches the sample dimension. However, the position is shifted when the field inhomogeneity exists. Experiments and simulations are performed to validate our theoretic analysis. These signal features may offer a unique way to investigate porous structures and may find applications in biomedicine and material science. 展开更多
关键词 nuclear magnetic resonance distant dipolar field intermolecular double-quantum coher-ence signal dip
下载PDF
Bifurcations of double homoclinic flip orbits with resonant eigenvalues
17
作者 张天四 朱德明 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2007年第11期1517-1526,共10页
Concerns double homoclinic loops with orbit flips and two resonant eigenvalues in a four-dimensional system. We use the solution of a normal form system to construct a singular map in some neighborhood of the equilibr... Concerns double homoclinic loops with orbit flips and two resonant eigenvalues in a four-dimensional system. We use the solution of a normal form system to construct a singular map in some neighborhood of the equilibrium, and the solution of a linear variational system to construct a regular map in some neighborhood of the double homoclinic loops, then compose them to get the important Poincaré map. A simple calculation gives explicitly an expression of the associated successor function. By a delicate analYSiS of the bifurcation equation, we obtain the condition that the original double homoclinic loops are kept, and prove the existence and the existence regions of the large 1-homoclinic orbit bifurcation surface, 2-fold large 1-periodic orbit bifurcation surface, large 2-homoclinic orbit bifurcation surface and their approximate expressions. We also locate the large periodic orbits and large homoclinic orbits and their number. 展开更多
关键词 double homoclinic orbits orbit flip periodic orbit resonance
下载PDF
Determination of Matrine and Oxymatrine in Radix Sophorae Flavescentis by Resonance Rayleigh Scattering, Second-order Scattering and Frequency Doubling Scattering Technique
18
作者 SONG Yan-qi LIU Shao-pu +1 位作者 LIU Zhong-fang HU Xiao-li 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第5期746-749,共4页
In 0.1 mol/L HCl medium, 12-tungstophosphoric(TP) acid reacted with matrine(Mat) and oxymatrine(Oxy) to form an ion-association complex. As a result, the new spectra of resonance Rayleigh scattering(RRS), seco... In 0.1 mol/L HCl medium, 12-tungstophosphoric(TP) acid reacted with matrine(Mat) and oxymatrine(Oxy) to form an ion-association complex. As a result, the new spectra of resonance Rayleigh scattering(RRS), second-order scattering(SOS) and frequency doubling scattering(FDS) appeared and their intensities were enhanced greatly. The maximum scattering wavelengths of RRS, SOS and FDS were located at 370, 670 and 390 nm, respectively. The in-crements of scattering intensity were directly proportional to the concentration of Mat and Oxy in a certain range. Based on this, the method for the determination of matrine and oxymatrine has been established. It has been applied to the determination of matrine and oxymatrine in samples of Radix sophorae flavescentis with satisfactory result. The reaction mechanism and reasons of RRS enhancement were discussed. 展开更多
关键词 MATRINE OXYMATRINE 12-Tungstophosphoric acid resonance Rayleigh scattering Second-order scattering Frequency doubling scattering
下载PDF
Solid-state resonant tunneling thermoelectric refrigeration in the cylindrical double-barrier nanostructure
19
作者 刘念 罗小光 章毛连 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第8期285-288,共4页
A solid-state thermoelectric refrigerator with a cylindrical InP/InAs/InP double-barrier heterostructure is proposed. Based on the ballistic electron transport and the asymmetrical transmission, we derive the expressi... A solid-state thermoelectric refrigerator with a cylindrical InP/InAs/InP double-barrier heterostructure is proposed. Based on the ballistic electron transport and the asymmetrical transmission, we derive the expressions of the performance parameters of this refrigerator. The cooling rate rather than the coefficient of performance is affected by the area of the inner cylinder. Then through the numerical simulation, a triangular cooling rate region is found with respect to the chemical potential and bias voltage; further, that it is because of the small full width at half maximum of the transmission resonance and the linear relationship between the energy position of resonance and the bias voltage. These tunable results might supply some guide to the cooling in tiny components or devices. 展开更多
关键词 THERMOELECTRIC cooling region double-barrier heterostructure resonant tunneling
下载PDF
2.32W anti-misaligned Er:LuAG single-longitudinal-mode laser in the double corner-cube-retroreflector resonator and MOPA system
20
作者 范佳玮 鞠有伦 +7 位作者 姜辰晨 袁越 闫东 杨星帮 段小明 戴通宇 姚宝权 吴佳泽 《Chinese Optics Letters》 SCIE EI CAS CSCD 2024年第2期114-119,共6页
We demonstrate a high power,Er:Lu AG single-longitudinal-mode laser in an anti-misaligned resonator.Based on the Faraday effect,a 1.61 W single-longitudinal-mode(SLM)laser is obtained with the double corner-cube-retro... We demonstrate a high power,Er:Lu AG single-longitudinal-mode laser in an anti-misaligned resonator.Based on the Faraday effect,a 1.61 W single-longitudinal-mode(SLM)laser is obtained with the double corner-cube-retroreflector(CCR)structure,and the tunable wavelength is 1649.2-1650.3 nm.Additionally,we investigate the anti-misalignment characteristics when the CCR moves and rotates along the optical axis.Furthermore,by utilizing the Er:Lu AG amplifier,the maximum 2.32 W single-longitudinal-mode laser at 1649.6 nm is achieved.The beam quality factors M^(2) of the 2.32 W Er:Lu AG single-longitudinal-mode laser are 1.23 and 1.25 along the horizontal(x)and vertical(y)directions,respectively. 展开更多
关键词 Er:Lu AG single-longitudinal-mode laser Faraday effect MOPA system double corner-cube-retroreflector resonator
原文传递
上一页 1 2 36 下一页 到第
使用帮助 返回顶部