There are many structural lateral systems used in tall buildings: rigid frames, braced frames, shear walls, tubular structures and core structures. The outrigger and belt truss systems are efficient structures for dr...There are many structural lateral systems used in tall buildings: rigid frames, braced frames, shear walls, tubular structures and core structures. The outrigger and belt truss systems are efficient structures for drift control and base moment reduction in tall buildings where the core alone is not rigid enough to resist lateral loads. Perimeter columns are mobilized for increasing the effective width of the structure, and they developed tension in the windward columns and compression in the leeward columns. Optimum locations for the outriggers have been studied because of the influence on the top displacement and base moment in the core. It was analyzed the optimal position for two to seven outriggers and belt trusses, aiming to achieve minimum bending moment and minimum drift.展开更多
The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using...The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using a firefly algorithm, from where savings of 43.3% on energy not served are achieved.展开更多
文摘There are many structural lateral systems used in tall buildings: rigid frames, braced frames, shear walls, tubular structures and core structures. The outrigger and belt truss systems are efficient structures for drift control and base moment reduction in tall buildings where the core alone is not rigid enough to resist lateral loads. Perimeter columns are mobilized for increasing the effective width of the structure, and they developed tension in the windward columns and compression in the leeward columns. Optimum locations for the outriggers have been studied because of the influence on the top displacement and base moment in the core. It was analyzed the optimal position for two to seven outriggers and belt trusses, aiming to achieve minimum bending moment and minimum drift.
文摘The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using a firefly algorithm, from where savings of 43.3% on energy not served are achieved.