期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Dosimetric Effects Due to Inter-Observer Variability of Organ Contouring When Utilizing a Knowledge-Based Planning System for Prostate Cancer
1
作者 Han Liu Christopher Amaloo +1 位作者 Benjamin Sintay David Wiant 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2021年第2期47-58,共12页
<strong>Purpose:</strong><span style="font-family:;" "=""><span style="font-family:Verdana;"> Radiotherapy is a widely accepted standard of care for early-sta... <strong>Purpose:</strong><span style="font-family:;" "=""><span style="font-family:Verdana;"> Radiotherapy is a widely accepted standard of care for early-stage prostate cancer, and it is believed that the plan quality and treatment outcome are associated with contour accuracy of both the target and organs-at-risk (OAR). The purposes of this study are to 1) assess geometric and dosimetric uncertainties due to inter-observer contour variabilities and 2) evaluate the effectiveness of geometric indicators to predict target dosimetry in prostate radiotherapy. </span><b><span style="font-family:Verdana;">Methods:</span></b><span style="font-family:Verdana;"> Twenty prostate patients were selected for this retrospective study. Five experienced clinicians created unique structure sets containing prostate, seminal vesicles, bladder, and rectum for each patient. A fully automated script and knowledge-based planning routine were utilized to create standardized and unbiased plans that could be used to evaluate changes in isodose distributions due to inter-observer variability in structure segmentation. Plans were created on a “gold-standard” structure set, as well as on each of the user-defined structure sets. </span><b><span style="font-family:Verdana;">Results:</span></b><span style="font-family:Verdana;"> Inter-observer variability of contours during structure segmentation was very low for clearly defined organs such as the bladder but increased for organs without well-defined borders (prostate, seminal vesicles, and rectum). For plans generated with the user-defined structure sets, strong/moderate correlations were observed between the geometric indicators for target structure agreement and target coverage for both low-risk and intermediate-risk patient groups, while OAR indicators showed no correlation to final dosimetry. </span><b><span style="font-family:Verdana;">Conclusions:</span></b><span style="font-family:Verdana;"> Target delineation is crucial in order to maintain adequate dosimetric coverage regardless of the associated inter-observer uncertainties in OAR contours that had a limited impact upon final dosimetry.</span></span> 展开更多
关键词 Inter-Observer Variability of organ contouring Knowledge-Based Treat-ment Planning Prostate Radiotherapy
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部