期刊文献+
共找到645篇文章
< 1 2 33 >
每页显示 20 50 100
Oral Hygiene in the Presence of Orthodontic Therapy
1
作者 Emmanuel John Aryeetey Hicham Benyahia Fatima Zaoui 《Journal of Biosciences and Medicines》 2024年第2期98-110,共13页
Orthodontic treatment offers great advantages in improving facial and smile aesthetics, self-confidence and the function of the stomatognathic apparatus. The pursuit of these advantages makes use of orthodontic applia... Orthodontic treatment offers great advantages in improving facial and smile aesthetics, self-confidence and the function of the stomatognathic apparatus. The pursuit of these advantages makes use of orthodontic appliances that could be fixed or removable. However, it’s worth stating that these appliances interfere with tooth brushing, making it more difficult to brush teeth effectively. Orthodontics appliances therefore promote the accumulation of dental plaque, which results in both quantitative and qualitative changes in the oral microbiota, hence, exposing patients to several adverse effects such as White spot lesions, dental caries, periodontal pathologies and halitosis. For this reason, oral assessment of patients before, during and after treatment is necessary as well as oral hygiene instructions and motivation. Orthodontists therefore, should educate patients on oral and periodontal hygiene in order to control dental and periodontal complications. Prescriptions of plaque control materials adapted to each patient are done in order to optimize the final result and minimize unwanted complications. 展开更多
关键词 orthodontic Treatment Oral Microbiome Oral Hygiene PERIODONTITIS GINGIVITIS orthodontic Fixed appliances orthodontic removable appliances White Spot Lesions (WSL)
下载PDF
3D打印个性化正畸装置对单根牙垂直移动的三维有限元分析
2
作者 曹怡琳 王心彧 +5 位作者 庄妍 王亚茹 姜至秀 刘丹瑜 门九旭 丁元圣 《中国组织工程研究》 CAS 北大核心 2025年第16期3360-3368,共9页
背景:基于牙齿垂直移动原理,通过数字化设计结合3D打印制作个性化正畸装置,可使个性化正畸装置与单个切牙形成支抗系统。借助微种植体绝对支抗作用可对单根牙在三维方向上进行精准控制。目的:基于生物力学原理设计了牙位11、12、21、22... 背景:基于牙齿垂直移动原理,通过数字化设计结合3D打印制作个性化正畸装置,可使个性化正畸装置与单个切牙形成支抗系统。借助微种植体绝对支抗作用可对单根牙在三维方向上进行精准控制。目的:基于生物力学原理设计了牙位11、12、21、22压低移动与伸长移动的个性化正畸装置,通过三维有限元法分析个性化正畸装置的安全性与其对牙齿的移动作用。方法:应用Mimics、Geomagic Wrap、SolidWorks和Ansys Workbench软件分别建立了上颌前牙区(牙位11、12、21、22)牙槽骨-牙周膜-上颌切牙-个性化悬臂微种植体-连接板-个性化托槽的三维有限元模型,每个牙位分别设置个性化压低移动与伸长移动正畸装置,加载300 g拉力或推力,分析个性化正畸装置各部件应力水平,计算牙齿位移与牙周膜应力分布情况。结果与结论:①个性化压低移动正畸装置受到的最大等效应力为162.90 MPa,个性化伸长移动正畸装置受到的最大等效应力239.57 MPa,二者的最大等效应力均位于个性化托槽加力附件的垂直部分,个性化正畸装置各部件所受等效应力均在屈服强度内,均具有良好的安全性;②在个性化正畸装置作用下,牙齿初始位移呈现整体压低或伸长移动的趋势,垂直方向上的位移远远超过在水平方向和矢状方向上的位移;牙周膜根尖或颈部位置出现等效应力峰值,在根尖区牙周膜出现等效应力集中区域;③结果显示,个性化正畸装置可以使牙位11、12、21、22近似达到压低移动或伸长移动的目的,初步证实了个性化垂直移动正畸装置的有效性。 展开更多
关键词 3D打印个性化正畸装置 单根牙 压低移动 伸长移动 三维有限元分析 支抗 生物力学
下载PDF
The effect of chlorhexidine on plaque index and mutans streptococci in orthodontic patients:A pilot study
3
作者 Gisele Faria Milton Santamaria Jr. +3 位作者 Bianca Mota dos Santos Izabel Yoko Ito Janete Cinira Bregagnolo Maria Bernadete Sasso Stuani 《Open Journal of Stomatology》 2013年第6期323-328,共6页
Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to ... Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to their acrylic resin composition. Methods: Forty-five patients (6 to 12 years old) were randomly assigned into three groups with 15 patients each. Group I (control)—without orthodontic appliances disinfection;Group II—removable orthodontic appliances which had been immersed in 0.12% chlorhexidine digluconate overnight (8 hours), and Group III—orthodontic appliances in which 0.12% chlorhexidine digluconate solution had been incorporated into their resin composition. Saliva was collected for quantification of MS and evaluation of plaque index was performed before and after installation of orthodontic appliance at 0, 2, 4, 6, 8, and 10 weeks. Data were analyzed by using analysis of variance. Results: Number of MS colonies in saliva and plaque index showed no statistically differences among groups at the different periods (p > 0.05). Conclusions: It could be concluded that chlorhexidine incorporation into the acrylic resin of removable orthodontic appliances at 0.12% concentration and immersion of the appliance into 0.12% chlorhexidine solution were not effective in reducing plaque index and the number of MS in saliva. 展开更多
关键词 CHLORHEXIDINE Self-Polymerising Acrylic removable orthodontic appliances Mutans Streptococci Plaque Index
下载PDF
Colour stabilities of three types of orthodontic clear aligners exposed to staining agents 被引量:5
4
作者 Chen-Lu Liu Wen-Tian Sun +5 位作者 Wen Liao Wen-Xin Lu Qi-Wen Li Yunho Jeong Jun Liu Zhi-He Zhao 《International Journal of Oral Science》 SCIE CAS CSCD 2016年第4期246-253,共8页
The aim of this study was to evaluate and compare the colour stabilities of three types of orthodontic clear aligners exposed to staining agents in vitro. Sixty clear orthodontic aligners produced by three manufacture... The aim of this study was to evaluate and compare the colour stabilities of three types of orthodontic clear aligners exposed to staining agents in vitro. Sixty clear orthodontic aligners produced by three manufacturers (Invisalign, Angelalign, and Smartee) were immersed in three staining solutions (coffee, black tea, and red wine) and one control solution (distilled water). After 12-h and 7-day immersions, the aligners were washed in an ultrasonic cleaner and measured with a colourimeter. The colour changes (△E*) were calculated on the basis of the Commission Internationale de I'Eclairage L*a*b* colour system (CIE L*a*b*), and the results were then converted into National Bureau of Standards (NBS) units. Fourier transformation infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM) were conducted to observe the molecular and morphologic alterations to the aligner surfaces, respectively. The three types of aligners exhibited slight colour changes after 12 h of staining, with the exception of the Invisalign aligners stained with coffee. The Invisalign aligners exhibited significantly higher AE* values (ranging from 0.30 to 27.81) than those of the Angelalign and Smartee aligners (AE* values ranging from 0.33 to 1.89 and 0.32 to 1.61, respectively, P〈O.05). IFT-IR analysis confirmed that the polymer-based structure of aligners did not exhibit significant chemical differences before and after the immersions. The SEM results revealed different surface alterations to the three types of aligner materials after the 7-day staining. The three types of aesthetic orthodontic appliances exhibited colour stability after the 12-h immersion, with the exception of the Invisalign aligners stained by coffee. The Invisalign aligners were more prone than the Angelalign and Smartee aligners to pigmentation. Aligner materials may be improved by considering aesthetic colour stability properties. 展开更多
关键词 AESTHETICS clear aligner clear aligner material colour stability orthodontic appliance
下载PDF
Is Caries in the Early Mixed Dentition Associated with Caries Development during Orthodontic Treatment?
5
作者 Valbona Soumas Stavros Kiliaridis Christine B. Staudt 《Journal of Biosciences and Medicines》 2015年第11期25-32,共8页
Objective: To investigate if caries in the pre-treatment early mixed dentition is associated with caries development in the permanent dentition during orthodontic treatment. Material and Methods: We included 41 consec... Objective: To investigate if caries in the pre-treatment early mixed dentition is associated with caries development in the permanent dentition during orthodontic treatment. Material and Methods: We included 41 consecutive patients (29 girls, 12 boys) with a pre-treatment documentation in the mixed (mean age 9.4 years) and a post treatment documentation in the permanent dentition (age 14.9 years) (two-phased treatment time 4.5 (±1.6) years). The DMFT/S indices were calculated. High-risk and low-risk groups were defined according to dmfs + DMFS score before treatment. Results: Initial dmft/s + DMFT/S (SD) was 5.15 (3.60) and 8.32 (6.64);final DMFT/S was 2.76 (2.84) and 3.01 (3.20). The missing (because of decay) second deciduous molars were most powerfully associated with caries increment during treatment, showing significant correlations to second premolars (r = 0.47, p = 0.003), while fillings on second deciduous molars seem to influence the prevalence of fillings on permanent molars (r = 0.44, p = 0.001). The increment at surface level was 2.01 (2.61) in the whole sample and 2.60 (3.81) in the high-risk group (4 boys, 6 girls). Compared to the low-risk group (10 girls), post-treatment caries experience was significantly higher in the high-risk group (p = 0.029). Boys were more at risk than girls (p = 0.005). Conclusions: Children with elevated caries experience in the early mixed dentition are exposed to higher caries risk during orthodontic treatment. Thus, in prevision of treatment, caries should already be assessed in the mixed dentition, so that an extended prophylaxis program can be initiated. 展开更多
关键词 Bitewing RADIOGRAPHY CARIES INCREMENT DMF Indices Mixed DENTITION orthodontic appliances
下载PDF
Accuracy of Orthodontic 3D Printed Retainers versus Thermoformed Retainers
6
作者 Ahmed A. Nasef Amr R. El-Beialy +1 位作者 Faten Hussein Kamel Eid Yehya A. Mostafa 《Open Journal of Medical Imaging》 2017年第4期169-179,共11页
Background: The integration of the current technology of CBCT and 3D CAD/CAM technology has great potential in the field of orthodontics, which is not yet fully investigated. The purpose of this article is to evaluate... Background: The integration of the current technology of CBCT and 3D CAD/CAM technology has great potential in the field of orthodontics, which is not yet fully investigated. The purpose of this article is to evaluate the accuracy of 3D printed retainers in comparison to vacuum formed retainers. Methods: Alginate impressions were taken for ten patients who have a CBCT scan. A 3D printed retainer and vacuum formed retainer were fabricated. Linear measure-ments were measured by two assessors using digital caliper. Every measure-ment on the 3D printed retainer was compared to the corresponding measure-ment on the thermoformed retainer. The linear measurements were Inter-canine width, Inter-premolar width (first and second premolars), Inter-molar width, Canine-midline length (both sides) and Canine-molar length (both sides). Intra-observer, and inter-observer reliability measurements were done. Results: Results showed excellent intra-observer reliability for the thermoformed retainer and the 3D printed retainer. Inter-observer measurements showed strong agreement between the measurements of the two assessors, for both retainers. The comparison of the thermoformed retainer to the 3D printed retainer showed high statistical agreement, except for the canine-molar on the right side, but with no clinical significance, p value of 0.038 and mean difference 0.19. Conclusions: The new method for fabricating a 3D printed retainer is accurate and reliable in comparison to the vacuum formed retainer (conventional method). CBCT proved to be efficient for fabrication of a custom made appliances. 展开更多
关键词 3D PRINTING Additive Manufacturing Digital orthodonticS DENTISTRY orthodonticS orthodontic APPLIANCE Design orthodontic appliances orthodontic Retainers Technology DENTAL
下载PDF
Insight into orthodontic appliance induced pain:Mechanism,duration and management
7
作者 Yasemin Kartal Omur Polat-Ozsoy 《World Journal of Anesthesiology》 2016年第1期28-35,共8页
Most of the orthodontic patients experience pain during treatment and this significantly influences their attitudes and the approach towards treatment. A number of factors that influence pain response include age, gen... Most of the orthodontic patients experience pain during treatment and this significantly influences their attitudes and the approach towards treatment. A number of factors that influence pain response include age, gender, personal pain threshold, mood and stress level of the person, cultural differences and types of orthodontic treatment. Pain is a often overlooked subject by orthodontists, it is nevertheless important to understand the source and mechanism of the pain that occurs during treatment, as well as the methods for managing and controlling this pain. This review attempts to overview the mechanism, duration and current management strategies of orthodontic treatment. 展开更多
关键词 orthodontic appliance Pain mechanism orthodontic treatment PAIN Pain management
下载PDF
认知行为干预对固定矫正器正畸患者心理负担和自护能力的影响 被引量:3
8
作者 陈刚 莫丽飞 胡宇 《中国健康心理学杂志》 2024年第5期709-714,共6页
目的:探讨认知行为干预对固定矫正器正畸患者心理负担和自护能力的影响。方法:选取2020年1月-2021年1月某院收治的90例固定矫正器正畸患者为研究对象,按照入院先后分为对照组和观察组,每组各45例;对照组采取常规干预,观察组采取认知行... 目的:探讨认知行为干预对固定矫正器正畸患者心理负担和自护能力的影响。方法:选取2020年1月-2021年1月某院收治的90例固定矫正器正畸患者为研究对象,按照入院先后分为对照组和观察组,每组各45例;对照组采取常规干预,观察组采取认知行为干预;对比两组治疗依从性,干预前后心理负担[汉密尔顿焦虑自评量表(HAMA)、汉密尔顿抑郁自评量表(HAMD)]、舒适度和疼痛情况[Kolcaba简化舒适状况量表、视觉模拟评分法(VAS)]、自护能力[自我护理能力量表(ESCA)]及自我效能[口腔保健自我效能量表(SESS)]。结果:两组治疗依从性比较,观察组高于对照组(χ^(2)=5.404,P<0.05)。干预后,两组HAMA、HAMD评分均下降(P<0.05),且观察组均低于对照组(t=-8.993,-7.187;P<0.05);干预后,两组Kolcaba量表评分均升高(P<0.05),且观察组均高于对照组(t=10.804,P<0.05);两组VAS评分均降低(P<0.05),且观察组均低于对照组(t=-15.429,P<0.05);干预后,两组自我概念、健康知识水平、自我护理技能、自我护理责任感及ESCA量表总分均高于干预前(P<0.05),且观察组均高于对照组(t=6.692,3.663,5.640,5.183;P<0.05);干预后,两组口腔就诊、正确刷牙、平衡饮食得分均高于干预前(P<0.05),且观察组均高于对照组(t=4.295,7.013,7.427;P<0.05)。结论:对固定矫正器正畸患者采用认知行为干预效果显著,可提高治疗依从性,减轻心理负担,缓解疼痛,提高舒适度、自护能力和口腔保健自我效能。 展开更多
关键词 认知行为干预 固定矫正器 正畸 心理负担 自护能力 舒适度 疼痛 口腔保健自我效能
下载PDF
无托槽隐形矫治器治疗骨性Ⅱ类错[牙合]的疗效分析
9
作者 王茜 王伟砚 李光辉 《成都医学院学报》 CAS 2024年第3期442-445,共4页
目的 探讨无托槽隐形矫治器治疗骨性Ⅱ类错[牙合]的疗效。方法 以2021年7月至2023年10月在郑州大学第一附属医院进行正畸治疗的87例骨性Ⅱ类错[牙合]患者为研究对象开展回顾性分析,根据应用矫治器的不同分为传统组(应用传统固定矫治器治... 目的 探讨无托槽隐形矫治器治疗骨性Ⅱ类错[牙合]的疗效。方法 以2021年7月至2023年10月在郑州大学第一附属医院进行正畸治疗的87例骨性Ⅱ类错[牙合]患者为研究对象开展回顾性分析,根据应用矫治器的不同分为传统组(应用传统固定矫治器治疗,n=44)和隐形组(应用无托槽隐形矫治器治疗,n=43)。比较两组矫治效果[采用美国正畸专家认证委员会(ABO)评级系统评定]、侧貌美学指标、牙周指数[探诊深度(PD)、菌斑指数(PLI)及牙龈指数(GI)]及龈沟液炎症因子[白细胞介素-1β(IL-1β)和可溶性细胞间黏附分子1(sICAM-1)]水平。结果 矫治后,隐形组ABO评级系统中的8项分值及总分与传统组比较,差异无统计学意义(P>0.05);矫治后,两组颌凸角、上下中切牙角、U1-PP、FMA、UL-EP、TLL-EP均优于矫治前(P<0.05),其中隐形组上下中切牙角、FMA优于传统组(P<0.05);矫治后,隐形组PD、PLI、GI及龈沟液IL-1β、sICAM-1水平均低于传统组(P<0.05)。结论 无托槽隐形矫治器可有效矫正骨性Ⅱ类错[牙合]畸形,提高患者侧貌美观度,并能减少对牙周组织的损害。 展开更多
关键词 无托槽隐形矫治器 骨性Ⅱ类错[牙合] 咬合功能 侧貌美观度
下载PDF
无托槽牙齿矫治器个性化设计与3D成型
10
作者 关天民 李新 +1 位作者 马强 翟贇 《医用生物力学》 CAS CSCD 北大核心 2024年第1期164-171,共8页
目的 对牙齿矫治器开展有限元仿真分析以确定不同工况的矫正量,制定无托槽牙齿矫治器的设计方案,使熔融沉积工艺成型的矫治器具备个性化的矫治效果。方法 结合患者CT数据逆向重构牙齿模型,通过有限元方法确立牙齿在倾斜、扭转、平移3种... 目的 对牙齿矫治器开展有限元仿真分析以确定不同工况的矫正量,制定无托槽牙齿矫治器的设计方案,使熔融沉积工艺成型的矫治器具备个性化的矫治效果。方法 结合患者CT数据逆向重构牙齿模型,通过有限元方法确立牙齿在倾斜、扭转、平移3种工况下的矫治量。选择不同弹性模量的材料3D成型不同矫治类型无托槽牙齿矫治器,并测量正畸力。结果 针对不同工况可设计不同的矫治偏移量,从而使矫治器具备个性化治疗效果。无托槽牙齿矫治器的正畸力随着弹性模量和厚度的增加而增大。在给定工况下,当矫治器材料为热可塑性聚氨酯(TPU)时正畸力最小(90 mN);当矫治器材料为聚乳酸(PLA)时正畸力最大(61.66 N)。结论 设计应根据患者的牙齿情况,在整个矫治过程中每一步矫治所需要正畸力的大小,选择不同弹性模量和不同厚度的无托槽牙齿矫治器对患者畸形牙齿进行治疗,从而实现分阶段矫治效果。 展开更多
关键词 无托槽牙齿矫治器 逆向重构 熔融沉积工艺 结构优化 正畸力
下载PDF
隐适美矫治器与Damon Q自锁托槽非拔牙矫治牙列拥挤的临床疗效比较 被引量:1
11
作者 邹慧 彭友俭 《中国美容医学》 CAS 2024年第1期125-129,共5页
目的:探讨隐适美矫治器与Damon Q自锁托槽非拔牙矫治牙列拥挤患者的临床疗效。方法:选取2019年1月-2022年1月在笔者医院完成非拔牙矫正治疗的100例牙列拥挤患者为研究对象,根据不同矫治方式分为隐适美组(使用隐适美矫治器行正畸治疗)52... 目的:探讨隐适美矫治器与Damon Q自锁托槽非拔牙矫治牙列拥挤患者的临床疗效。方法:选取2019年1月-2022年1月在笔者医院完成非拔牙矫正治疗的100例牙列拥挤患者为研究对象,根据不同矫治方式分为隐适美组(使用隐适美矫治器行正畸治疗)52例和Damon Q组(使用Damon Q自锁托槽矫治器行正畸治疗)48例。对比分析两组患者牙弓宽度指标(尖牙间宽度、第一前磨牙间宽度、第一磨牙间宽度),牙周健康指标[牙龈指数(Gingival index,GI)、菌斑指数(Plaque index,PLI)、龈沟出血指数(Sulcus bleeding index,SBI)],龈沟液炎症指标[白介素-1β(Interleukin-1β,IL-1β)、肿瘤坏死因子-α(Tumor necrosis factor-α,TNF-α)],以及口腔相关生活质量评分。结果:治疗结束后,两组患者牙弓宽度均显著增加(P<0.05),但两组比较差异无统计学意义(P>0.05)。治疗后,两组患者GI、PLI、SBI、IL-1β、TNF-α指标均显著高于治疗前,且Damon Q组治疗1个月、2个月、3个月后各指标均高于隐适美组(P<0.05)。治疗期间,两组患者OHIP-14评分均高于治疗前,且Damon Q组治疗3个月、6个月后各指标评分均高于隐适美组(P<0.05);但治疗结束后,两组患者OHIP-14评分均低于治疗前(P<0.05)。结论:隐适美矫治器和Damon Q自锁托槽非拔牙矫治牙列拥挤均有良好效果,可改善牙弓宽度,对患者牙齿口腔卫生影响较小,但隐适美矫治器更易保证牙周健康,控制牙周疾病的发生,值得临床推广应用。 展开更多
关键词 牙列拥挤 非拔牙矫治 隐适美矫治器 Damon Q自锁托槽 牙周健康
下载PDF
不同釉质黏结剂对牙龈卟啉单胞菌和变形链球菌的影响
12
作者 李志耀 胡铮 +1 位作者 李晅 陆珮珺 《中国组织工程研究》 CAS 北大核心 2024年第3期329-335,共7页
背景:光固化型和含氟光固化型釉质黏结剂对酸蚀后的牙釉质表面有一定封闭作用,含氟光固化型釉质黏结剂还能通过释放氟离子实现防龋功能,但缺乏对氟化物较长时间释放的研究,尤其缺乏经历1-3个月氟化物释放后局部致病菌量的变化信息。目的... 背景:光固化型和含氟光固化型釉质黏结剂对酸蚀后的牙釉质表面有一定封闭作用,含氟光固化型釉质黏结剂还能通过释放氟离子实现防龋功能,但缺乏对氟化物较长时间释放的研究,尤其缺乏经历1-3个月氟化物释放后局部致病菌量的变化信息。目的:分析青少年正畸治疗患者上前牙使用不同组分釉质黏结剂黏结固定矫治器引发的龈下菌斑中牙龈卟啉单胞菌和变形链球菌表达变化。方法:选择2016年1-12月就诊于上海市口腔医院接受正畸治疗的青少年患者90例,其中男43例,女47例,平均年龄(13.27±1.12)岁。采用随机数字表法将90例患者分为3组:化学固化组应用Unite™黏结树脂进行固定矫治器的黏结,光固化组应用Transbond XT光固化树脂进行固定矫治器的黏结,含氟光固化组应用GC光固化正畸黏结用水门汀进行固定矫治器的黏结,每组30例。在黏结托槽当天(初始黏结)及第1,2,3个月复诊时收集患者上前牙龈下菌斑标本,应用PCR技术检测牙龈卟啉单胞菌和变形链球菌的增殖表达量。结果与结论:①组内比较:随着黏结时间的增加,化学固化组3个月复诊时的牙龈卟啉单胞菌增殖表达显著高于初始黏结时(P<0.05);光固化组1个月复诊时的牙龈卟啉单胞菌增殖表达低于初始黏结时(P<0.05);含氟光固化组1,2个月复诊时的牙龈卟啉单胞菌增殖表达均低于初始黏结时(P<0.05)。化学固化组复诊1,2,3个月时的变形链球菌表达高于初始黏结时(P<0.05);含氟光固化组复诊1,2,3个月时的变形链球菌增殖表达均低于初始黏结时(P<0.05);光固化组复诊时的变形链球菌增殖表达与初始黏结时比较差异无显著性意义(P>0.05);②组间比较:1个月复诊时,光固化组、含氟光固化组牙龈卟啉单胞菌增殖表达低于化学固化组(P<0.05);2,3个月复诊时,含氟光固化组牙龈卟啉单胞菌增殖表达低于光固化组、化学固化组(P<0.05)。1,2,3个月复诊时,光固化组、含氟光固化组变形链球菌增殖表达低于化学固化组(P<0.05),含氟光固化组变形链球菌增殖表达低于光固化组(P<0.05)。③结果显示,在固定正畸中,使用不同组分的釉质黏结剂黏结托槽后,短期内对患者口内牙龈卟啉单胞菌和变形链球菌的增殖表达有不同程度影响,其中含氟光固化釉质黏结剂在托槽黏结初期有助于减少牙釉质脱矿、龋病和牙周炎症的发生。 展开更多
关键词 口腔正畸 固定矫治器 釉质黏结剂 牙龈卟啉单胞菌 变形链球菌
下载PDF
替牙期无托槽隐形矫治器扩弓治疗改良设计的有限元分析
13
作者 吕秦毅 高子琦 +2 位作者 冯青辰 梅宏翔 李娟 《上海交通大学学报(医学版)》 CAS CSCD 北大核心 2024年第8期935-943,共9页
目的·借助有限元分析揭示无托槽隐形矫治器用于替牙期扩弓治疗时单颗牙位移方向、效率及力学荷载,并针对扩弓效率不足以及后牙颊倾等问题,设计扩弓过矫治和转矩补偿体系。方法·纳入替牙期志愿者1名,构建其颅上颌复合体三维模... 目的·借助有限元分析揭示无托槽隐形矫治器用于替牙期扩弓治疗时单颗牙位移方向、效率及力学荷载,并针对扩弓效率不足以及后牙颊倾等问题,设计扩弓过矫治和转矩补偿体系。方法·纳入替牙期志愿者1名,构建其颅上颌复合体三维模型以及隐形矫治体系,模拟无托槽隐形矫治器对上颌乳尖牙到第一恒磨牙施加颊向位移(工况1~4:分别为0.200、0.275、0.300、0.325 mm),同时施加颊向位移和根颊向转矩(工况1:颊向位移载荷0.200 mm,根颊向转矩0°;工况5:颊向位移载荷0.275 mm,根颊向转矩1.0°;工况6:颊向位移载荷0.300 mm,根颊向转矩1.3°;工况7:颊向位移载荷0.325 mm,根颊向转矩1.8°)。通过有限元分析,计算牙齿位移以及牙周膜的等效应力分布。结果·无托槽隐形矫治器扩弓治疗在替牙期主要表现为牙齿颊倾的牙性扩弓效应,且不同牙位的扩弓效率不同。在设定每侧0.200 mm的扩弓量时,上颌第一恒磨牙扩弓效率为51.86%,上颌第二乳磨牙为68.76%,上颌第一乳磨为73.48%,上颌乳尖牙为84.17%。通过设计扩弓过矫治(0.275、0.300、0.325 mm),能够有效提高扩弓效果。当扩弓过矫治量达到150%(0.300 mm)时,上颌第一恒磨牙、第二乳磨牙、第一乳磨牙和乳尖牙处扩弓效率分别提升为75.16%、99.96%、107.35%和122.37%;上颌第二乳磨牙、第一乳磨牙、乳尖牙处扩弓效率均接近100.00%。过矫治设计会加剧扩弓的牙性效应,使牙齿颊侧倾斜移动趋势加大,导致牙齿颊倾、腭尖下垂,上颌第一恒磨牙、第二乳磨牙、第一乳磨牙、乳尖牙的冠根位移差在扩弓过矫治量达到150%时,分别为-0.109、-0.134、-0.132、-0.298 mm。对不同牙位施加对应转矩补偿,可以对抗后牙颊倾。在扩弓过矫治量达到150%(0.300 mm)时,添加1.3°根颊向转矩,各牙位扩弓效率分别为56.15%、73.88%、79.49%、87.80%,而冠根位移差减小至-0.081、-0.097、-0.095、-0.208 mm。结论·无托槽隐形矫治器用于替牙期扩弓治疗时,存在后牙颊倾的不良反应,并且在不同牙位的扩弓效率不同。应根据不同牙位,分别设计不同的矫治策略。过矫治可以提高扩弓效率,但是需要配合根颊向转矩,从而实现牙齿整体颊侧移动。 展开更多
关键词 扩弓治疗 口腔正畸 替牙期 正畸矫治器 可摘式 透明矫治器 有限元分析
下载PDF
基于正畸患者需求行为分析的矫治器选择服务研究
14
作者 余瑞 林聪 +3 位作者 程平 王红 孔海燕 陈叶俊 《中国美容医学》 CAS 2024年第9期171-174,共4页
目的:通过调查安徽省某口腔医院正畸患者对矫治器选择的现状,了解口腔正畸患者的实际需求,从而为正畸科医生在诊治过程中有效沟通与精准治疗提供参考依据。方法:选取2023年1月-2023年5月在安徽省某口腔医院正畸科接受正畸矫治的330例患... 目的:通过调查安徽省某口腔医院正畸患者对矫治器选择的现状,了解口腔正畸患者的实际需求,从而为正畸科医生在诊治过程中有效沟通与精准治疗提供参考依据。方法:选取2023年1月-2023年5月在安徽省某口腔医院正畸科接受正畸矫治的330例患者作为研究对象,采用问卷调查法,根据Angle安氏错牙合畸形分类方法对患者进行分类,分析不同年龄、性别、居住地、错牙合畸形类别对矫治器倾向选择和实际选择的影响。结果:330例患者中牙齿畸形类型以安氏Ⅱ类为主(59.09%);就诊最期待能够解决的问题是牙齿不齐,其次是嘴巴外突和牙齿间隙过大;出于经济、舒适、美观等方面考虑,进口金属自锁托槽在实际应用中占比最高(57.27%);不同年龄、性别的患者选择的矫治器类型差异有统计学意义(P<0.05)。结论:正畸医生在为患者提供正畸矫治方案时,应询问患者对矫治器的选择倾向,并考虑患者年龄、性别、错牙合畸形类型等情况,给患者提出专业指导。 展开更多
关键词 口腔正畸 医患沟通 选择倾向 口腔矫治器
下载PDF
骨性Ⅱ类伴埋伏牙双期矫正病例1例
15
作者 郭凯 韩欣颖 +2 位作者 马浩杰 刘丽娟 杨芳红 《口腔医学》 CAS 2024年第5期338-343,共6页
骨性Ⅱ类的患者常表现为上颌前牙前突,下颌后缩,开唇露齿,前牙深覆牙合、深覆盖等症状,严重影响颜面美观。本文报道1例一期早期矫治配合二期固定矫治治疗骨性Ⅱ类伴埋伏牙的生长发育期男性患者病例。治疗后骨性Ⅱ类症状明显改善,包括下... 骨性Ⅱ类的患者常表现为上颌前牙前突,下颌后缩,开唇露齿,前牙深覆牙合、深覆盖等症状,严重影响颜面美观。本文报道1例一期早期矫治配合二期固定矫治治疗骨性Ⅱ类伴埋伏牙的生长发育期男性患者病例。治疗后骨性Ⅱ类症状明显改善,包括下颌后缩的改善,开唇露齿问题得到解决,面部外观趋向于直面型,同时颞下颌关节未出现明显异常。该病例显示早期矫正对此类患者可以达到良好的治疗效果,可以避免或减少此类患者成年后正颌手术的可能性。 展开更多
关键词 骨性Ⅱ类 双期矫正 埋伏牙 TWIN-BLOCK矫治器
下载PDF
基于多准则决策模型对隐形和固定矫治器治疗儿童错[牙合]畸形的效益-风险分析 被引量:1
16
作者 张力山 白晓滟 聂汶涵 《郑州大学学报(医学版)》 CAS 北大核心 2024年第3期415-419,共5页
目的:基于多准则决策模型对隐形和固定矫治器治疗儿童错[牙合]畸形进行效益-风险分析。方法:选择2022年1月至10月进行正畸治疗的110例错[牙合]畸形患儿,采用无托槽隐形矫正器治疗(隐形组)55例,采用多托槽固定矫治器治疗(固定组)55例。... 目的:基于多准则决策模型对隐形和固定矫治器治疗儿童错[牙合]畸形进行效益-风险分析。方法:选择2022年1月至10月进行正畸治疗的110例错[牙合]畸形患儿,采用无托槽隐形矫正器治疗(隐形组)55例,采用多托槽固定矫治器治疗(固定组)55例。比较两组患儿治疗前后牙龈指数(GI)、菌斑指数(PLI)、龈沟出血指数(SBI)和龈沟探诊深度(SPD)、咀嚼功能、口腔健康影响程度量表(OHIP)得分、龈沟液中TNF-α和IL-1β含量、牙槽骨密度、牙槽骨高度的差值,以及治疗费用和并发症发生状况。建立多准则决策模型,比较两组的效益值和风险值。结果:两组治疗前后SBI、PLI、咀嚼功能、OHIP得分,IL-1β和TNF-α含量、不适感差值比较,差异有统计学意义(P<0.05),隐形组治疗费用高于固定组(P<0.05)。多准则决策决策模型显示效益指标中对治疗影响最大的是PLI,风险指标是牙周脓肿;隐形组和固定组的效益值分别为78和63,风险值分别为74和57,隐形组效益-风险总值比固定组高出16;在0%~100%相对风险权重范围内,隐形组的效益-风险总值总是高于固定组。结论:隐形矫治器治疗儿童错[牙合]畸形有助于保持牙周健康,具有更高的安全性。 展开更多
关键词 错[牙合]畸形 牙周健康 隐形矫治器 固定矫治器 正畸治疗
下载PDF
无托槽隐形矫治器与固定矫治器对口腔正畸治疗患者口腔微生物菌群和龈沟液sICAM-1、MMP-8水平的影响
17
作者 罗晓婷 刘颖萍 《临床和实验医学杂志》 2024年第20期2219-2223,共5页
目的探究无托槽隐形矫治器与固定矫治器对口腔正畸治疗患者口腔微生物菌群和龈沟液可溶性细胞间黏附分子-1(sICAM-1)、基质金属蛋白酶-8(MMP-8)水平的影响。方法前瞻性纳入2020年2月至2023年3月在山西省儿童医院接受正畸治疗的106例患... 目的探究无托槽隐形矫治器与固定矫治器对口腔正畸治疗患者口腔微生物菌群和龈沟液可溶性细胞间黏附分子-1(sICAM-1)、基质金属蛋白酶-8(MMP-8)水平的影响。方法前瞻性纳入2020年2月至2023年3月在山西省儿童医院接受正畸治疗的106例患者为研究对象,按照随机数字表法对患者分为对照组和研究组,每组各53例。对照组采用固定矫治器,研究组采用无托槽隐形矫治器。比较两组患者矫正前和矫正后3个月口腔微生物菌群情况(卟啉单胞菌、具核梭杆菌、福塞斯坦氏菌和中间型普里沃菌)、牙周健康情况(牙龈指数、龈沟出血指数、菌斑指数及龈沟探诊深度)、龈沟液sICAM-1和MMP-8水平、患者满意度及并发症情况。结果矫正后3个月,两组各菌群水平均较矫正前升高,但研究组卟啉单胞菌、具核梭杆菌、福塞斯坦氏菌、中间型普里沃菌水平分别为0.29±0.06、0.33±0.06、0.33±0.08、0.27±0.06,均低于对照组(0.35±0.07、0.44±0.08、0.45±0.09、0.37±0.09),差异均有统计学意义(P<0.05)。两组组内矫正后3个月的牙龈指数和龈沟探诊深度与矫正前比较,以及组间矫正后3个月的牙龈指数和龈沟探诊深度比较,差异均无统计学意义(P>0.05);两组矫正后3个月的龈沟出血指数及菌斑指数均较矫正前升高,且研究组出血指数及菌斑指数分别为(0.65±0.06)、(0.99±0.12)分,均低于对照组[(0.72±0.08)、(1.23±0.15)分],差异均有统计学意义(P<0.05)。矫正后3个月,两组龈沟液sICAM-1水平均较矫正前升高,MMP-8水平均较矫正前降低,研究组龈沟液sICAM-1、MMP-8水平分别为(166.26±21.02)、(22.12±3.39)ng/mL,均低于对照组[(178.52±23.05)、(26.77±4.12)ng/mL],差异均有统计学意义(P<0.05)。研究组患者矫正后3个月的咀嚼、固定、美观、舒适性、方便程度、言语功能的满意度均高于对照组,差异均有统计学意义(P<0.05)。研究组患者牙龈红肿、牙龈萎缩、局部拥挤等总并发症发生率为7.55%,低于对照组(22.64%),差异有统计学意义(P<0.05)。结论相比固定矫治器矫正,采用无托槽隐形矫治器矫正对口腔微生物菌群和龈沟液中sICAM-1、MMP-8水平具有积极影响,能够提高患者的满意度,降低牙周疾病的发生。 展开更多
关键词 龈沟液 可溶性细胞间黏附分子-1 基质金属蛋白酶-8 无托槽隐形矫治器 固定矫治器 正畸矫治器 口腔微生物
下载PDF
隐形矫治器矫治与传统固定矫治对重度牙周炎正畸患者牙槽骨改建的效果观察
18
作者 曾鑫 陈潇 黄小洋 《中南医学科学杂志》 CAS 2024年第5期811-814,共4页
目的 探究隐形矫治器矫治与传统固定矫治治疗重度牙周炎正畸患者牙槽骨改建的效果观察。方法 将134例重度牙周炎正畸患者随机均分为传统组与隐形组,其中传统组采用传统固定矫治器矫治,隐形组采用无托槽隐形矫治器矫治。比较两组牙周健... 目的 探究隐形矫治器矫治与传统固定矫治治疗重度牙周炎正畸患者牙槽骨改建的效果观察。方法 将134例重度牙周炎正畸患者随机均分为传统组与隐形组,其中传统组采用传统固定矫治器矫治,隐形组采用无托槽隐形矫治器矫治。比较两组牙周健康指标、唇倾度、牙槽骨高度变化及密度变化、美容效果评分及并发症发生率。结果 正畸前后,两组GI、SPD与GBI均较牙周治疗前下降(P<0.05),正畸12个月后,传统组GI、SPD与GBI较正畸前均上升(P<0.05),且隐形组正畸12个月后低于传统组(P<0.05);正畸12个月后,两组上、下颌唇倾度较正畸前均降低,且隐形组低于传统组(P<0.05),传统组上、下牙槽骨高度较正畸前降低(P<0.05),且隐形组高于传统组(P<0.05),传统组牙槽骨密度较正畸前下降(P<0.05),牙槽嵴顶舌侧骨密度高于传统组(P<0.05);两组患者美容效果评分较正畸前上升,且隐形组高于传统组(P<0.05)。两组并发症发生率差异无显著性(P>0.05)。结论 无托槽隐形矫治器用于重度牙周炎患者正畸治疗,对牙周及牙槽骨影响小,整体美观度高,值得推荐。 展开更多
关键词 隐形矫治器 固定矫治器 重度牙周炎 正畸 美容效果
下载PDF
隐形矫治器远移成年患者上颌磨牙疗效的Meta分析
19
作者 康芙嘉 李欣鹏 +3 位作者 张茜雅 石芯宁 常路广达 朱宪春 《口腔疾病防治》 2024年第5期367-375,共9页
目的评价无托槽隐形矫治器远中移动成年患者上颌磨牙的临床疗效,以提高正畸医生对疗效的预估性。方法检索Web of Science、The Cochrane Library、Embase、Pubmed、万方数据库、知网数据库、维普数据库公开发表的隐形矫治器远移成年患... 目的评价无托槽隐形矫治器远中移动成年患者上颌磨牙的临床疗效,以提高正畸医生对疗效的预估性。方法检索Web of Science、The Cochrane Library、Embase、Pubmed、万方数据库、知网数据库、维普数据库公开发表的隐形矫治器远移成年患者上颌磨牙疗效的研究。检索时限为建库以来至2023年8月1日。共3名研究者进行文献筛选及质量评估,将满足质量标准的文献进行Meta分析。结果本研究共纳入13个前后对照试验,总样本量281例。Meta分析结果显示,治疗后颌骨矢状向及垂直向指标与治疗前相比差异无统计学意义(P>0.05);治疗后上颌第一磨牙远中移动量MD=-2.34,95%CI(-2.83,-1.85),压低移动量MD=-0.95,95%CI(-1.34,-0.56),远中倾斜量MD=-2.51,95%CI(-3.56,-1.46),与治疗前相比差异均有统计学意义(P<0.05);治疗后上颌切牙平均内收距离MD=-0.82,95%CI(-1.54,-0.09),唇倾度减小MD=-1.61,95%CI(-2.86,-0.36),与治疗前相比差异均有统计学意义(P<0.05)。结论隐形矫治器能够有效远中移动上颌磨牙并控制磨牙垂直向位置,磨牙远移的同时伴有一定的压低及远中倾斜移动,对高角型患者有利。上颌切牙的矢状向内收有利于患者侧貌的改善。 展开更多
关键词 META分析 隐形矫治器 磨牙远移 正畸 错畸形 安氏Ⅱ类 牙齿移动 切牙内收
下载PDF
Frankel Ⅲ型矫治器联合口唇肌训练治疗替牙期错[牙合]畸形的疗效评价
20
作者 丁敏林 张海亮 张吉敏 《上海口腔医学》 CAS 2024年第4期432-437,共6页
目的:探讨口唇肌训练配合FrankelⅢ型矫治器矫治替牙期Ⅲ类错[牙合]畸形的临床疗效。方法:选择杭州绿城口腔医院2018年6月-2022年12月收治的100例替牙期Ⅲ类错[牙合]畸形儿童,采用随机数字表法将患儿分为联合组(采用口唇肌训练配合Fran... 目的:探讨口唇肌训练配合FrankelⅢ型矫治器矫治替牙期Ⅲ类错[牙合]畸形的临床疗效。方法:选择杭州绿城口腔医院2018年6月-2022年12月收治的100例替牙期Ⅲ类错[牙合]畸形儿童,采用随机数字表法将患儿分为联合组(采用口唇肌训练配合FrankelⅢ型矫治器矫治)和对照组各50例(采用FrankelⅢ型矫治器矫治)。比较2组患儿治疗前后X线头影测量指标、颞下颌关节参数、上气道测量值参数及12个月后的随访情况。采用SPSS 21.0软件包对数据进行统计学分析。结果:治疗前,联合组和对照组SNA、SNB、ANB、U1-NA、L1-NB、ANS-Ptm、S-Ptm、Co-Po、CoS、MP-SN、MP-FH和NP-FH相比,差异无统计学意义(P>0.05);治疗后,联合组ANB、U1-NA、L1-NB和MP-SN大于对照组,NP-FH小于对照组,差异有统计学意义(P<0.05)。治疗前,联合组和对照组关节上间隙、前间隙和后间隙相比,差异无统计学意义(P>0.05);治疗后,联合组关节上间隙、后间隙大于对照组,差异有统计学意义(P<0.05)。治疗前,联合组和对照组Ba-PNS、Ad1-PNS、Ad2-PNS、Mc1-Mc2、SPP-SPPW、U-MPW、PAS和V-LPW相比,差异无统计学意义(P>0.05);治疗后,联合组Ad2-PNS大于对照组,差异有统计学意义(P<0.05)。随访12个月,联合组复发率为2.00%,显著低于对照组的16.00%(P<0.05)。结论:口唇肌训练配合FrankelⅢ型矫治器矫治替牙期Ⅲ类错[牙合]畸形,更有利于纠正畸形,改善上气道形态,降低治疗后复发率。 展开更多
关键词 口唇肌训练 FrankelⅢ型矫治器 替牙期 错[牙合]畸形
下载PDF
上一页 1 2 33 下一页 到第
使用帮助 返回顶部