Orthodontic treatment offers great advantages in improving facial and smile aesthetics, self-confidence and the function of the stomatognathic apparatus. The pursuit of these advantages makes use of orthodontic applia...Orthodontic treatment offers great advantages in improving facial and smile aesthetics, self-confidence and the function of the stomatognathic apparatus. The pursuit of these advantages makes use of orthodontic appliances that could be fixed or removable. However, it’s worth stating that these appliances interfere with tooth brushing, making it more difficult to brush teeth effectively. Orthodontics appliances therefore promote the accumulation of dental plaque, which results in both quantitative and qualitative changes in the oral microbiota, hence, exposing patients to several adverse effects such as White spot lesions, dental caries, periodontal pathologies and halitosis. For this reason, oral assessment of patients before, during and after treatment is necessary as well as oral hygiene instructions and motivation. Orthodontists therefore, should educate patients on oral and periodontal hygiene in order to control dental and periodontal complications. Prescriptions of plaque control materials adapted to each patient are done in order to optimize the final result and minimize unwanted complications.展开更多
Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to ...Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to their acrylic resin composition. Methods: Forty-five patients (6 to 12 years old) were randomly assigned into three groups with 15 patients each. Group I (control)—without orthodontic appliances disinfection;Group II—removable orthodontic appliances which had been immersed in 0.12% chlorhexidine digluconate overnight (8 hours), and Group III—orthodontic appliances in which 0.12% chlorhexidine digluconate solution had been incorporated into their resin composition. Saliva was collected for quantification of MS and evaluation of plaque index was performed before and after installation of orthodontic appliance at 0, 2, 4, 6, 8, and 10 weeks. Data were analyzed by using analysis of variance. Results: Number of MS colonies in saliva and plaque index showed no statistically differences among groups at the different periods (p > 0.05). Conclusions: It could be concluded that chlorhexidine incorporation into the acrylic resin of removable orthodontic appliances at 0.12% concentration and immersion of the appliance into 0.12% chlorhexidine solution were not effective in reducing plaque index and the number of MS in saliva.展开更多
The aim of this study was to evaluate and compare the colour stabilities of three types of orthodontic clear aligners exposed to staining agents in vitro. Sixty clear orthodontic aligners produced by three manufacture...The aim of this study was to evaluate and compare the colour stabilities of three types of orthodontic clear aligners exposed to staining agents in vitro. Sixty clear orthodontic aligners produced by three manufacturers (Invisalign, Angelalign, and Smartee) were immersed in three staining solutions (coffee, black tea, and red wine) and one control solution (distilled water). After 12-h and 7-day immersions, the aligners were washed in an ultrasonic cleaner and measured with a colourimeter. The colour changes (△E*) were calculated on the basis of the Commission Internationale de I'Eclairage L*a*b* colour system (CIE L*a*b*), and the results were then converted into National Bureau of Standards (NBS) units. Fourier transformation infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM) were conducted to observe the molecular and morphologic alterations to the aligner surfaces, respectively. The three types of aligners exhibited slight colour changes after 12 h of staining, with the exception of the Invisalign aligners stained with coffee. The Invisalign aligners exhibited significantly higher AE* values (ranging from 0.30 to 27.81) than those of the Angelalign and Smartee aligners (AE* values ranging from 0.33 to 1.89 and 0.32 to 1.61, respectively, P〈O.05). IFT-IR analysis confirmed that the polymer-based structure of aligners did not exhibit significant chemical differences before and after the immersions. The SEM results revealed different surface alterations to the three types of aligner materials after the 7-day staining. The three types of aesthetic orthodontic appliances exhibited colour stability after the 12-h immersion, with the exception of the Invisalign aligners stained by coffee. The Invisalign aligners were more prone than the Angelalign and Smartee aligners to pigmentation. Aligner materials may be improved by considering aesthetic colour stability properties.展开更多
Objective: To investigate if caries in the pre-treatment early mixed dentition is associated with caries development in the permanent dentition during orthodontic treatment. Material and Methods: We included 41 consec...Objective: To investigate if caries in the pre-treatment early mixed dentition is associated with caries development in the permanent dentition during orthodontic treatment. Material and Methods: We included 41 consecutive patients (29 girls, 12 boys) with a pre-treatment documentation in the mixed (mean age 9.4 years) and a post treatment documentation in the permanent dentition (age 14.9 years) (two-phased treatment time 4.5 (±1.6) years). The DMFT/S indices were calculated. High-risk and low-risk groups were defined according to dmfs + DMFS score before treatment. Results: Initial dmft/s + DMFT/S (SD) was 5.15 (3.60) and 8.32 (6.64);final DMFT/S was 2.76 (2.84) and 3.01 (3.20). The missing (because of decay) second deciduous molars were most powerfully associated with caries increment during treatment, showing significant correlations to second premolars (r = 0.47, p = 0.003), while fillings on second deciduous molars seem to influence the prevalence of fillings on permanent molars (r = 0.44, p = 0.001). The increment at surface level was 2.01 (2.61) in the whole sample and 2.60 (3.81) in the high-risk group (4 boys, 6 girls). Compared to the low-risk group (10 girls), post-treatment caries experience was significantly higher in the high-risk group (p = 0.029). Boys were more at risk than girls (p = 0.005). Conclusions: Children with elevated caries experience in the early mixed dentition are exposed to higher caries risk during orthodontic treatment. Thus, in prevision of treatment, caries should already be assessed in the mixed dentition, so that an extended prophylaxis program can be initiated.展开更多
Background: The integration of the current technology of CBCT and 3D CAD/CAM technology has great potential in the field of orthodontics, which is not yet fully investigated. The purpose of this article is to evaluate...Background: The integration of the current technology of CBCT and 3D CAD/CAM technology has great potential in the field of orthodontics, which is not yet fully investigated. The purpose of this article is to evaluate the accuracy of 3D printed retainers in comparison to vacuum formed retainers. Methods: Alginate impressions were taken for ten patients who have a CBCT scan. A 3D printed retainer and vacuum formed retainer were fabricated. Linear measure-ments were measured by two assessors using digital caliper. Every measure-ment on the 3D printed retainer was compared to the corresponding measure-ment on the thermoformed retainer. The linear measurements were Inter-canine width, Inter-premolar width (first and second premolars), Inter-molar width, Canine-midline length (both sides) and Canine-molar length (both sides). Intra-observer, and inter-observer reliability measurements were done. Results: Results showed excellent intra-observer reliability for the thermoformed retainer and the 3D printed retainer. Inter-observer measurements showed strong agreement between the measurements of the two assessors, for both retainers. The comparison of the thermoformed retainer to the 3D printed retainer showed high statistical agreement, except for the canine-molar on the right side, but with no clinical significance, p value of 0.038 and mean difference 0.19. Conclusions: The new method for fabricating a 3D printed retainer is accurate and reliable in comparison to the vacuum formed retainer (conventional method). CBCT proved to be efficient for fabrication of a custom made appliances.展开更多
Most of the orthodontic patients experience pain during treatment and this significantly influences their attitudes and the approach towards treatment. A number of factors that influence pain response include age, gen...Most of the orthodontic patients experience pain during treatment and this significantly influences their attitudes and the approach towards treatment. A number of factors that influence pain response include age, gender, personal pain threshold, mood and stress level of the person, cultural differences and types of orthodontic treatment. Pain is a often overlooked subject by orthodontists, it is nevertheless important to understand the source and mechanism of the pain that occurs during treatment, as well as the methods for managing and controlling this pain. This review attempts to overview the mechanism, duration and current management strategies of orthodontic treatment.展开更多
目的评价无托槽隐形矫治器远中移动成年患者上颌磨牙的临床疗效,以提高正畸医生对疗效的预估性。方法检索Web of Science、The Cochrane Library、Embase、Pubmed、万方数据库、知网数据库、维普数据库公开发表的隐形矫治器远移成年患...目的评价无托槽隐形矫治器远中移动成年患者上颌磨牙的临床疗效,以提高正畸医生对疗效的预估性。方法检索Web of Science、The Cochrane Library、Embase、Pubmed、万方数据库、知网数据库、维普数据库公开发表的隐形矫治器远移成年患者上颌磨牙疗效的研究。检索时限为建库以来至2023年8月1日。共3名研究者进行文献筛选及质量评估,将满足质量标准的文献进行Meta分析。结果本研究共纳入13个前后对照试验,总样本量281例。Meta分析结果显示,治疗后颌骨矢状向及垂直向指标与治疗前相比差异无统计学意义(P>0.05);治疗后上颌第一磨牙远中移动量MD=-2.34,95%CI(-2.83,-1.85),压低移动量MD=-0.95,95%CI(-1.34,-0.56),远中倾斜量MD=-2.51,95%CI(-3.56,-1.46),与治疗前相比差异均有统计学意义(P<0.05);治疗后上颌切牙平均内收距离MD=-0.82,95%CI(-1.54,-0.09),唇倾度减小MD=-1.61,95%CI(-2.86,-0.36),与治疗前相比差异均有统计学意义(P<0.05)。结论隐形矫治器能够有效远中移动上颌磨牙并控制磨牙垂直向位置,磨牙远移的同时伴有一定的压低及远中倾斜移动,对高角型患者有利。上颌切牙的矢状向内收有利于患者侧貌的改善。展开更多
文摘Orthodontic treatment offers great advantages in improving facial and smile aesthetics, self-confidence and the function of the stomatognathic apparatus. The pursuit of these advantages makes use of orthodontic appliances that could be fixed or removable. However, it’s worth stating that these appliances interfere with tooth brushing, making it more difficult to brush teeth effectively. Orthodontics appliances therefore promote the accumulation of dental plaque, which results in both quantitative and qualitative changes in the oral microbiota, hence, exposing patients to several adverse effects such as White spot lesions, dental caries, periodontal pathologies and halitosis. For this reason, oral assessment of patients before, during and after treatment is necessary as well as oral hygiene instructions and motivation. Orthodontists therefore, should educate patients on oral and periodontal hygiene in order to control dental and periodontal complications. Prescriptions of plaque control materials adapted to each patient are done in order to optimize the final result and minimize unwanted complications.
文摘Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to their acrylic resin composition. Methods: Forty-five patients (6 to 12 years old) were randomly assigned into three groups with 15 patients each. Group I (control)—without orthodontic appliances disinfection;Group II—removable orthodontic appliances which had been immersed in 0.12% chlorhexidine digluconate overnight (8 hours), and Group III—orthodontic appliances in which 0.12% chlorhexidine digluconate solution had been incorporated into their resin composition. Saliva was collected for quantification of MS and evaluation of plaque index was performed before and after installation of orthodontic appliance at 0, 2, 4, 6, 8, and 10 weeks. Data were analyzed by using analysis of variance. Results: Number of MS colonies in saliva and plaque index showed no statistically differences among groups at the different periods (p > 0.05). Conclusions: It could be concluded that chlorhexidine incorporation into the acrylic resin of removable orthodontic appliances at 0.12% concentration and immersion of the appliance into 0.12% chlorhexidine solution were not effective in reducing plaque index and the number of MS in saliva.
基金funded by the Orthodontic National Key Clinical Specialty Construction Program of Chinathe West China Hospital of Stomatology Sichuan Universitysupported by grants from the National Natural Science Foundation of China (Grant No. 31470904 and 81470722)
文摘The aim of this study was to evaluate and compare the colour stabilities of three types of orthodontic clear aligners exposed to staining agents in vitro. Sixty clear orthodontic aligners produced by three manufacturers (Invisalign, Angelalign, and Smartee) were immersed in three staining solutions (coffee, black tea, and red wine) and one control solution (distilled water). After 12-h and 7-day immersions, the aligners were washed in an ultrasonic cleaner and measured with a colourimeter. The colour changes (△E*) were calculated on the basis of the Commission Internationale de I'Eclairage L*a*b* colour system (CIE L*a*b*), and the results were then converted into National Bureau of Standards (NBS) units. Fourier transformation infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM) were conducted to observe the molecular and morphologic alterations to the aligner surfaces, respectively. The three types of aligners exhibited slight colour changes after 12 h of staining, with the exception of the Invisalign aligners stained with coffee. The Invisalign aligners exhibited significantly higher AE* values (ranging from 0.30 to 27.81) than those of the Angelalign and Smartee aligners (AE* values ranging from 0.33 to 1.89 and 0.32 to 1.61, respectively, P〈O.05). IFT-IR analysis confirmed that the polymer-based structure of aligners did not exhibit significant chemical differences before and after the immersions. The SEM results revealed different surface alterations to the three types of aligner materials after the 7-day staining. The three types of aesthetic orthodontic appliances exhibited colour stability after the 12-h immersion, with the exception of the Invisalign aligners stained by coffee. The Invisalign aligners were more prone than the Angelalign and Smartee aligners to pigmentation. Aligner materials may be improved by considering aesthetic colour stability properties.
文摘Objective: To investigate if caries in the pre-treatment early mixed dentition is associated with caries development in the permanent dentition during orthodontic treatment. Material and Methods: We included 41 consecutive patients (29 girls, 12 boys) with a pre-treatment documentation in the mixed (mean age 9.4 years) and a post treatment documentation in the permanent dentition (age 14.9 years) (two-phased treatment time 4.5 (±1.6) years). The DMFT/S indices were calculated. High-risk and low-risk groups were defined according to dmfs + DMFS score before treatment. Results: Initial dmft/s + DMFT/S (SD) was 5.15 (3.60) and 8.32 (6.64);final DMFT/S was 2.76 (2.84) and 3.01 (3.20). The missing (because of decay) second deciduous molars were most powerfully associated with caries increment during treatment, showing significant correlations to second premolars (r = 0.47, p = 0.003), while fillings on second deciduous molars seem to influence the prevalence of fillings on permanent molars (r = 0.44, p = 0.001). The increment at surface level was 2.01 (2.61) in the whole sample and 2.60 (3.81) in the high-risk group (4 boys, 6 girls). Compared to the low-risk group (10 girls), post-treatment caries experience was significantly higher in the high-risk group (p = 0.029). Boys were more at risk than girls (p = 0.005). Conclusions: Children with elevated caries experience in the early mixed dentition are exposed to higher caries risk during orthodontic treatment. Thus, in prevision of treatment, caries should already be assessed in the mixed dentition, so that an extended prophylaxis program can be initiated.
文摘Background: The integration of the current technology of CBCT and 3D CAD/CAM technology has great potential in the field of orthodontics, which is not yet fully investigated. The purpose of this article is to evaluate the accuracy of 3D printed retainers in comparison to vacuum formed retainers. Methods: Alginate impressions were taken for ten patients who have a CBCT scan. A 3D printed retainer and vacuum formed retainer were fabricated. Linear measure-ments were measured by two assessors using digital caliper. Every measure-ment on the 3D printed retainer was compared to the corresponding measure-ment on the thermoformed retainer. The linear measurements were Inter-canine width, Inter-premolar width (first and second premolars), Inter-molar width, Canine-midline length (both sides) and Canine-molar length (both sides). Intra-observer, and inter-observer reliability measurements were done. Results: Results showed excellent intra-observer reliability for the thermoformed retainer and the 3D printed retainer. Inter-observer measurements showed strong agreement between the measurements of the two assessors, for both retainers. The comparison of the thermoformed retainer to the 3D printed retainer showed high statistical agreement, except for the canine-molar on the right side, but with no clinical significance, p value of 0.038 and mean difference 0.19. Conclusions: The new method for fabricating a 3D printed retainer is accurate and reliable in comparison to the vacuum formed retainer (conventional method). CBCT proved to be efficient for fabrication of a custom made appliances.
文摘Most of the orthodontic patients experience pain during treatment and this significantly influences their attitudes and the approach towards treatment. A number of factors that influence pain response include age, gender, personal pain threshold, mood and stress level of the person, cultural differences and types of orthodontic treatment. Pain is a often overlooked subject by orthodontists, it is nevertheless important to understand the source and mechanism of the pain that occurs during treatment, as well as the methods for managing and controlling this pain. This review attempts to overview the mechanism, duration and current management strategies of orthodontic treatment.
文摘目的评价无托槽隐形矫治器远中移动成年患者上颌磨牙的临床疗效,以提高正畸医生对疗效的预估性。方法检索Web of Science、The Cochrane Library、Embase、Pubmed、万方数据库、知网数据库、维普数据库公开发表的隐形矫治器远移成年患者上颌磨牙疗效的研究。检索时限为建库以来至2023年8月1日。共3名研究者进行文献筛选及质量评估,将满足质量标准的文献进行Meta分析。结果本研究共纳入13个前后对照试验,总样本量281例。Meta分析结果显示,治疗后颌骨矢状向及垂直向指标与治疗前相比差异无统计学意义(P>0.05);治疗后上颌第一磨牙远中移动量MD=-2.34,95%CI(-2.83,-1.85),压低移动量MD=-0.95,95%CI(-1.34,-0.56),远中倾斜量MD=-2.51,95%CI(-3.56,-1.46),与治疗前相比差异均有统计学意义(P<0.05);治疗后上颌切牙平均内收距离MD=-0.82,95%CI(-1.54,-0.09),唇倾度减小MD=-1.61,95%CI(-2.86,-0.36),与治疗前相比差异均有统计学意义(P<0.05)。结论隐形矫治器能够有效远中移动上颌磨牙并控制磨牙垂直向位置,磨牙远移的同时伴有一定的压低及远中倾斜移动,对高角型患者有利。上颌切牙的矢状向内收有利于患者侧貌的改善。