Based on the monitoring data of chemical oxygen demand(COD),permanganate index(I Mn)and five-day biochemical oxygen demand(BOD 5)of surface water in Tongling section of Yangtze River,the linear relationship among the ...Based on the monitoring data of chemical oxygen demand(COD),permanganate index(I Mn)and five-day biochemical oxygen demand(BOD 5)of surface water in Tongling section of Yangtze River,the linear relationship among the three indexes in the annual data analysis and the internal reasons,as well as the linear relationship and changes among the three indexes in different seasons were analyzed.The results reveal that in terms of the whole year,COD,I Mn and BOD 5 had a significant correlation and good linear relationship.The fitting slopes of the three indexes were 3.89 of COD/I Mn,4.39 of COD/BOD 5 and 1.16 of I Mn/BOD 5,respectively,which corresponded to the proportional relationship among the three indexes.From the perspective of seasonal changes,there was a very significant correlation between the three indexes in spring and summer.In autumn and winter,only COD and I Mn had a good correlation,but they had a poor correlation with BOD 5.展开更多
The removal of the natural organic matter present in coffee processing wastewater through chemical coagulation-flocculation and advanced oxidation processes (AOP) had been studied. The effectiveness of the removal o...The removal of the natural organic matter present in coffee processing wastewater through chemical coagulation-flocculation and advanced oxidation processes (AOP) had been studied. The effectiveness of the removal of natural organic matter using commercial flocculants and UV/H202, UV/O3 and UV/H2O2/O3 processes was determined under acidic conditions. For each of these processes, different operational conditions were explored to optimize the treatment efficiency of the coffee wastewater. Coffee wastewater is characterized by a high chemical oxygen demand (COD) and low total suspended solids. The outcomes of coffee wastewater treatment using coagulation-flocculation and photodegradation processes were assessed in terms of reduction of COD, color, and turbidity. It was found that a reduction in COD of 67% could be realized when the coffee wastewater was treated by chemical coagulation-flocculation with lime and coagulant T-1. When coffee wastewater was treated by coagulation-flocculation in combination with UV/H2O2, a COD reduction of 86% was achieved, although only after prolonged UV irradiation. Of the three advanced oxidation processes considered, UV/H2O2, UV/O3 and UV/H2O2/O3, we found that the treatment with UV/H2O2/O3 was the most effective, with an efficiency of color, turbidity and further COD removal of 87%, when applied to the flocculated coffee wastewater.展开更多
A three-dimensional advection-diffusion model coupled with the degradation process is established for describing the transport of chemical oxygen demand (COD). Comparison of the simulated distribution of COD at the su...A three-dimensional advection-diffusion model coupled with the degradation process is established for describing the transport of chemical oxygen demand (COD). Comparison of the simulated distribution of COD at the surface in the Bohai Sea in August, 2001 with field observations, shows that the model simulates the dataset reasonably well. The Laizhou Bay, Bohai Bay, and Liaodong Bay were contaminated heavily near shore. Based on the optimal discharge flux method, the Environmental Capacity (EC) and allocated capacities of COD in the Bohai Sea are calculated. For seawater of Grades I to IV of the Chinese National Standard, the ECs of COD in the Bohai Sea were 77×104 t/a, 116×104 t/a, 154×104 t/a and 193×104 t/a, respectively. The Huanghe (Yellow) River pollutant discharge accounted for the largest percentage of COD at 14.3%, followed by that of from the Liugu River (11.5%), and other nine local rivers below 10%. The COD level in 2005 was worse than that of Grade II seawater and was beyond the environmental capacity. In average, 35% COD reduction is called to meet the standard of Grade I seawater.展开更多
A field observation was carried out in the Changjiang (Yangtze) River Estuary from May 19 to 26, 2003. A total of 29 stations, including 2 anchored stations, were occupied through almost the whole salinity gradient. B...A field observation was carried out in the Changjiang (Yangtze) River Estuary from May 19 to 26, 2003. A total of 29 stations, including 2 anchored stations, were occupied through almost the whole salinity gradient. Based on the observation data, biogeochemistry of chemical oxygen demand (COD) was examined. Spatial distribution pattern of COD shows that it decreased downstream. The COD concentration varied generally within a narrow range of 1.24–1.60 mg/L in the zone around the river mouth, beyond which it decreased rapidly to 0.20 mg/L. In the mixed water zone, the fluctuation in COD was smaller at 2 m above the bottom layer than at the surface layer in 48 h. In the seawater zone, the 48-h fluctuation at the surface was the largest, followed by that of 5 m below the surface and 2 m above the bottom layers in a range of from 2.50 to 0.55 mg/L. Freshwater discharge was the dominant source of COD in the estuary. The average COD beyond the river mouth was 2.7 mg/L, which accorded with the Chinese seawater quality Grade I. Relationships between dissolved oxygen and biogeochemical parameters such as suspended particulate matter, dissolved organic matter and chlorophyll-a were also discussed.展开更多
Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts...Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts to produce online predictions of the chemical oxygen demand (COD) in wastewater from a pulp and paper mill using NIR spectroscopy are described. The task was perceived as very challenging, but with a root mean square error of prediction of 149 mg/l, roughly corresponding to 1/10 of the studied concentration interval, this attempt was deemed as successful. This result was obtained by using partial least squares model regression, interpolated reference values for calibration purposes, and by evenly distributing the calibration data in the concentration space. This work may also represent the first industrial application of online COD measurements in wastewater using NIR spectroscopy.展开更多
To rapidly determine the pollution extent of wastewater, the calibration models were established for deter-mination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater by partial least squares and nea...To rapidly determine the pollution extent of wastewater, the calibration models were established for deter-mination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater by partial least squares and near infrared spectrometry of 120 samples. Spectral data preprocessing and outliers’ diagnosis were also discussed. Correlation coefficients of the models were 0.9542 and 0.9652, and the root mean square error of prediction (RMSEP) were 25.24 mg?L-1 and 12.13 mg?L-1 in the predicted range of 28.40~528.0 mg?L-1 and 16.0~305.2 mg?L-1 for Chemical Oxygen Demand and Biological Oxygen Demand, respectively. By statistical significance test, the results of determination were compared with those of stan-dard methods with no significant difference at 0.05 level. The method has been applied to simultaneous de-termination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater with satisfactory results.展开更多
It is difficult to measure the online values of biochemical oxygen demand(BOD) due to the characteristics of nonlinear dynamics, large lag and uncertainty in wastewater treatment process. In this paper, based on the k...It is difficult to measure the online values of biochemical oxygen demand(BOD) due to the characteristics of nonlinear dynamics, large lag and uncertainty in wastewater treatment process. In this paper, based on the knowledge representation ability and learning capability, an improved T–S fuzzy neural network(TSFNN) is introduced to predict BOD values by the soft computing method. In this improved TSFNN, a K-means clustering is used to initialize the structure of TSFNN, including the number of fuzzy rules and parameters of membership function. For training TSFNN, a gradient descent method with the momentum item is used to adjust antecedent parameters and consequent parameters. This improved TSFNN is applied to predict the BOD values in effluent of the wastewater treatment process. The simulation results show that the TSFNN with K-means clustering algorithm can measure the BOD values accurately. The algorithm presents better approximation performance than some other methods.展开更多
This paper presents a method for in situ determining sediment oxygen demand (SOD) in cultivation pond. This method based on sediment surface structure, temperature, and other determining conditions like those in shrim...This paper presents a method for in situ determining sediment oxygen demand (SOD) in cultivation pond. This method based on sediment surface structure, temperature, and other determining conditions like those in shrimp cultivation environments, overcomes defects of old methods and provides more accurate estimation of SOD’s effect on dissolved oxygen in culture waters. Our experiment shows that the sediment surface structure and temperature had important effect on SOD in culture water. Different SOD values were derived from different parts of oxygen consumption curves of sediment, because the curves were not linear. According to the oxygen consumption curves of sediment and saturated DO in culture water, it was thought more suitable to calculate SOD with dissolved oxygen reduction from 5.0 to 2.0 mg/l. This method to determine the SOD of shrimp ponds yielded satisfactory results.展开更多
Various water quality parameters of a leachate pond at an offshore municipal solid waste disposal site were monitored. The pH, dissolved oxygen (DO), and water temperature at the bottom of the leachate pond were measu...Various water quality parameters of a leachate pond at an offshore municipal solid waste disposal site were monitored. The pH, dissolved oxygen (DO), and water temperature at the bottom of the leachate pond were measured during Sep. (the 1st period) and Nov.-Dec. (the 2nd period) of 2011. The results suggested that the stratification of water temperature in the pond had gradually broken down due to convection occurring between the end of the 1st period and the 2nd period. The pH was almost constant at 10 - 11 during the 1st period and was approximately 11.5 during the 2nd period. The DO was almost zero during both periods. An anaerobic batch experiment with sampled sediment was undertaken to elucidate the mechanism of material leaching from the sediment. DO decreased under all experimental conditions. With respect to oxidation reduction potential (ORP) and total sulfide in addition to DO, the condition most closely mimicking that of the site became the most anaerobic. The average sediment oxygen demand, SODave, was calculated using a brief numerical model based on batch experiment data. The SODave was 1114.7 mg/m2/d, indicating that at least 434 g/d of oxygen must be supplied to the leachate pond to maintain the DO.展开更多
Identification of chemical oxygen demand(COD)in municipal solid waste(MSW)landfill leachates is a challenging problem.This paper investigated the feasibility of using sodium persulfate(PS),a strong oxidant,as a permea...Identification of chemical oxygen demand(COD)in municipal solid waste(MSW)landfill leachates is a challenging problem.This paper investigated the feasibility of using sodium persulfate(PS),a strong oxidant,as a permeable reactive barrier(PRB)filling material.Firstly,sustained-release persulfate balls were manufactured to adjust the release rate of persulfate,the oxidation agent.In addition,Fe(II)-loaded activated carbon(Fe-AC)was used to help with an even distribution of Fe(II)in the porous medium(PRB in this case).Then,the oxidation efficiency and kinetic rate of COD removal by the sustained-release balls were subjected to batch tests.A mass ratio of 1:1.4:0.24:0.7 for PS:cement:sand:water was the most efficient for COD removal(95%).The breakthrough curve for a 5 mm sustained-release ball revealed that the retardation factor was 1.27 and that the hydrodynamic dispersion coefficient was 15.6 cm^(2)/d.The corresponding half-life of COD oxidation was 0.43 d,which was comparable with the half-life of PS release from sustained-release balls(0.56 d).The sustained-release persulfate balls were shown to be an economical material with a simple recipe and production method when catalyzed by Fe-AC.Compared with cutting-edge methods,sustained-release balls used in PRBs offer significant advantages in terms of both effectiveness and economy for the preparation of sustained-release and catalytic materials.These results verified the feasibility of using sustained-release persulfate balls as a PRB material for COD removal.展开更多
Eco-friendly chemical oxygen demand(COD)sensors are highly desired with respect to the importance of COD determination in environmental protection.In this work,a new FTO/TiO_(2)/PbO_(2)(FTO=fluorine-doped tin oxide)el...Eco-friendly chemical oxygen demand(COD)sensors are highly desired with respect to the importance of COD determination in environmental protection.In this work,a new FTO/TiO_(2)/PbO_(2)(FTO=fluorine-doped tin oxide)electrode was fabricated with a two-step method and used as an eco-friendly electrochemical COD sensor.The interlayer TiO_(2)was employed to strengthen the adhesion of PbO_(2)on the FTO substrates by providing a large TiO_(2)/PbO_(2)interface area.The effects of the factors including applied potential,supporting electrolyte concentration and stirring speed on the sensing performance were investigated.Under the optimized conditions,linear responses to the COD of water with different COD sources were achieved,and a linear range from 5 to 120 mg/L was obtained in the case of sucrose as the COD source.The relative standard deviations(RSD)were determined to be less than 9%for the glucose solutions with the COD of 7.5,12.5 and 17.5 mg/L.For real sample analysis,the obtained results were comparable with those measured with the conventional dichromate method,with a relative error less than 11%.展开更多
Background:We aimed to investigate risk factors predicting oxygen demand in COVID-19 patients.Methods:Patients admitted to Shizuoka General Hospital with COVID-19 from August 2020 to August 2021 were included.First,we...Background:We aimed to investigate risk factors predicting oxygen demand in COVID-19 patients.Methods:Patients admitted to Shizuoka General Hospital with COVID-19 from August 2020 to August 2021 were included.First,we divided patients into groups with and without oxygen demand.Then,we compared patients’clinical characteristics and laboratory and radiological findings to determine factors predicting oxygen demand.Results:One hundred seventy patients with COVID-19(aged 58±15 years,57 females)were enrolled.Common comorbidities were cardiovascular diseases(47.6%),diabetes mellitus(28.8%),and dyslipidemia(26.5%).Elder age,higher body mass index,cardiovascular diseases,diabetes mellitus,lower lymphocyte count,albumin,hep-atic attenuation value,and the liver-to-spleen ratio(L/S),higher D-dimer,aspartate aminotransferase,lactate dehydrogenase,troponin-T,C-reactive protein,KL-6,chest and abdominal circumference,and visceral fat were found in patients with oxygen demand.According to the multivariate logistic regression analysis,L/S,lympho-cyte count,D-dimer,and abdominal circumference under the diaphragm were independent risk factors predicting oxygen demand in COVID-19 patients.Conclusions:On admission,L/S,lymphocyte count,D-dimer,and abdominal circumference were predictive factors for oxygen demand.These factors may help in the appropriate triage of COVID-19 patients in the decision to admit them to the hospital.展开更多
A photocatalytic oxidation method for determination of chemical oxygen demand (COD) using nano-TiO2 film, based on the use of a nano-TiO2-Ce(SO4)2 system and electrochemical detection, was proposed. The technique ...A photocatalytic oxidation method for determination of chemical oxygen demand (COD) using nano-TiO2 film, based on the use of a nano-TiO2-Ce(SO4)2 system and electrochemical detection, was proposed. The technique was originated from the direct determination of the Ce(Ⅲ) concentration change resulting from photocatalytic oxidation of organic compounds. Ce(Ⅲ), which was produced by photocatalytic reduction of Ce(SO4)2, could be measured at a multi-walled carbon nanotubes (MWNT) chemically modified electrode (CME). The COD values by this method were calculated from the differential pulse voltammetry (DPV) current of Ce(Ⅲ) at the CME. Under the optimal operation conditions, the detection limit of 0.5 mg·L^-1 COD with the linear range of 1-600 mg·L^-1 was achieved. This method was also applied to determination of various COD of ground water and wastewater samples. The resuits were in good agreement with those from the conventional COD methods, i.e., permanganate and dichromate ones.展开更多
Nitrobenzene is an important raw material and product, which presents a heavy threat to the ecosystem. The potential impacts of nitrobenzene on sediment oxygen demand (SOD) were studied in lake sediment simulating r...Nitrobenzene is an important raw material and product, which presents a heavy threat to the ecosystem. The potential impacts of nitrobenzene on sediment oxygen demand (SOD) were studied in lake sediment simulating reactors receiving relatively low inputs of nitrobenzene. Oxygen microprofiles were measured in these sediment reactors using microelectrodes. After an initial microprofile measurement as a control, nitrobenzene was added to the overlying water resulting in concentrations of 0, 50, 100, and 150 μg/L. Microprofiles were measured on day 1, 2, 4 and 7 following the addition of nitrobenzene. SODs were determined from the microprofiles using a reaction-diffusion model. Results showed that the SODs increased relative to the initial values measured in the pre-treatment period in reactors exposed to all nitrobenzene concentrations on day 1. However, the values decreased gradually on the following days, which eventually resulted in a 50% loss in SODs after 7 days of exposure to nitrobenzene in all reactors. In addition, the inhibition effect of nitrobenzene on SOD exhibited a weak relationship with its concentration. The microscopic observation and count of algae in the sediment showed that the exposure to nitrobenzene did not change the composition of algae greatly, however, it decreased the number of dominant algae species sharply after 7 days of exposure. These results suggested that nitrobenzene could significantly alter SOD in lakes, which could ultimately affect the pollutant recovery in aquatic-sediment systems.展开更多
Chemical oxygen demand(COD)is widely used as an organic pollution indicator in wastewater treatment plants.Large amounts of organic matter are removed during treatment processes to meet environmental standards,and con...Chemical oxygen demand(COD)is widely used as an organic pollution indicator in wastewater treatment plants.Large amounts of organic matter are removed during treatment processes to meet environmental standards,and consequently,substantial greenhouse gases(GHGs)such as methane(CH_(4))are released.However,the COD indicator covers a great amount of refractory organic matter that is not a pollutant and could be a potential carbon sink.Here,we collected and analysed COD data from 86 worldwide municipal wastewater treatment plants(WWTPs)and applied a model published by the Intergovernmental Panel on Climate Change to estimate the emission of CH_(4) due to recalcitrant organic compound processing in China’s municipal wastewater treatment systems.Our results showed that the average contribution of refractory COD to total COD removal was55%in 86 WWTPs.The amount of CH_(4) released from the treatment of recalcitrant organic matter in 2018 could have been as high as 38.22 million tons of carbon dioxide equivalent,which amounts to the annual carbon sequestered by China’s wetlands.This suggests that the use of COD as an indicator for organic pollution is undue and needs to be revised to reduce the emission of GHG.In fact,leaving nontoxic recalcitrant organic matter in the wastewater may create a significant carbon sink and will save energy during the treatment process,aiming at carbon neutrality in the wastewater treatment industry.展开更多
Evaluating the performance of a biotrickling filter for the treatment of wastewaters produced by a company manufacturing beer was the aim of this study.A pilot scale trickling filter filled with gravel was used as the...Evaluating the performance of a biotrickling filter for the treatment of wastewaters produced by a company manufacturing beer was the aim of this study.A pilot scale trickling filter filled with gravel was used as the experimental biofilter.Pilot scale plant experiments were made to evaluate the performance of the trickling filter aerobic and anaerobic biofilm systems for removal of chemical oxygen demand(COD) and nutrients from synthetic brewery wastewater.Performance evaluation data of the trickling filter were generated under different experimental conditions.The trickling filter had an average efficiency of(86.81±6.95)% as the hydraulic loading rate increased from 4.0 to 6.4 m3/(m2·d).Various COD concentrations were used to adjust organic loading rates from 1.5 to 4.5 kg COD/(m3·d).An average COD removal efficiency of(85.10±6.40)% was achieved in all wastewater concentrations at a hydraulic loading of 6.4 m3/(m2·d).The results lead to a design organic load of 1.5 kg COD/(m3·d) to reach an effluent COD in the range of 50–120 mg/L.As can be concluded from the results of this study,organic substances in brewery wastewater can be handled in a cost-effective and environmentally friendly manner using the gravel-filled trickling filter.展开更多
Sediment oxygen demand(SOD)is a major contributor to hypolimnetic oxygen depletion and the release of internal nutrient loading.By measuring the SOD in experimental chambers using in both dissolved oxygen(DO)depletion...Sediment oxygen demand(SOD)is a major contributor to hypolimnetic oxygen depletion and the release of internal nutrient loading.By measuring the SOD in experimental chambers using in both dissolved oxygen(DO)depletion and diffusional oxygen transfer methods,a model of SOD for a sediment bed with water current-induced turbulence was presented.An experimental study was also performed using near-sediment vertical DO profiles and correlated hydraulic parameters stimulated using a computational fluid dynamics model to determine how turbulences and DO concentrations in the overlying water affects SOD and diffusive boundary layer thickness.The dependence of the oxygen transfer coefficient and diffusive boundary layer on hydraulic parameters was quantified,and the SOD was expressed as a function of the shear velocity and the bulk DO concentrations.Theoretical predictions were validated using microelectrode measurements in a series of laboratory experiments.This study found that flow over the sediment surface caused an increase in SOD,attributed to enhanced sediment oxygen uptake and reduced substances fluxes,i.e.,for a constant maximum biological oxygen consumption rate,an increased current over the sediment could increase the SOD by 4.5 times compared to stagnant water.These results highlight the importance of considering current-induced SOD increases when designing and implementing aeration/artificial mixing strategies.展开更多
A new method for determining chemical oxygen demand (COD) value in water using ion chromatography coupled with nano TiO2-K2S2O8 co-existing system was described. The photocatalytic oxidation system and nano TiO2-K2S...A new method for determining chemical oxygen demand (COD) value in water using ion chromatography coupled with nano TiO2-K2S2O8 co-existing system was described. The photocatalytic oxidation system and nano TiO2-K2S2O8 co-existing system could degrade the organic compounds in water. All sulfur-containing species in the reactive solution were eventually transformed to sulfate which could be determined by conductivity detector in ion chromatography. The change of conductivity of sulfate was proportional to COD value. The optimal experimental conditions and the mechanism of the detection were discussed. The application range was 10.0-300.0 mg·L^-1 and the lowest limit of detection was 3.5 mg·L^-1. It was considered that the value obtained could be reliably correlated with the COD value obtained using the conventional methods.展开更多
文摘Based on the monitoring data of chemical oxygen demand(COD),permanganate index(I Mn)and five-day biochemical oxygen demand(BOD 5)of surface water in Tongling section of Yangtze River,the linear relationship among the three indexes in the annual data analysis and the internal reasons,as well as the linear relationship and changes among the three indexes in different seasons were analyzed.The results reveal that in terms of the whole year,COD,I Mn and BOD 5 had a significant correlation and good linear relationship.The fitting slopes of the three indexes were 3.89 of COD/I Mn,4.39 of COD/BOD 5 and 1.16 of I Mn/BOD 5,respectively,which corresponded to the proportional relationship among the three indexes.From the perspective of seasonal changes,there was a very significant correlation between the three indexes in spring and summer.In autumn and winter,only COD and I Mn had a good correlation,but they had a poor correlation with BOD 5.
文摘The removal of the natural organic matter present in coffee processing wastewater through chemical coagulation-flocculation and advanced oxidation processes (AOP) had been studied. The effectiveness of the removal of natural organic matter using commercial flocculants and UV/H202, UV/O3 and UV/H2O2/O3 processes was determined under acidic conditions. For each of these processes, different operational conditions were explored to optimize the treatment efficiency of the coffee wastewater. Coffee wastewater is characterized by a high chemical oxygen demand (COD) and low total suspended solids. The outcomes of coffee wastewater treatment using coagulation-flocculation and photodegradation processes were assessed in terms of reduction of COD, color, and turbidity. It was found that a reduction in COD of 67% could be realized when the coffee wastewater was treated by chemical coagulation-flocculation with lime and coagulant T-1. When coffee wastewater was treated by coagulation-flocculation in combination with UV/H2O2, a COD reduction of 86% was achieved, although only after prolonged UV irradiation. Of the three advanced oxidation processes considered, UV/H2O2, UV/O3 and UV/H2O2/O3, we found that the treatment with UV/H2O2/O3 was the most effective, with an efficiency of color, turbidity and further COD removal of 87%, when applied to the flocculated coffee wastewater.
基金Supported by 908 Program of the State Ocean Administration of China (Nos.908-02-02-02,908-02-02-03)the State Ocean Administration Foundation of China (No.200805065)
文摘A three-dimensional advection-diffusion model coupled with the degradation process is established for describing the transport of chemical oxygen demand (COD). Comparison of the simulated distribution of COD at the surface in the Bohai Sea in August, 2001 with field observations, shows that the model simulates the dataset reasonably well. The Laizhou Bay, Bohai Bay, and Liaodong Bay were contaminated heavily near shore. Based on the optimal discharge flux method, the Environmental Capacity (EC) and allocated capacities of COD in the Bohai Sea are calculated. For seawater of Grades I to IV of the Chinese National Standard, the ECs of COD in the Bohai Sea were 77×104 t/a, 116×104 t/a, 154×104 t/a and 193×104 t/a, respectively. The Huanghe (Yellow) River pollutant discharge accounted for the largest percentage of COD at 14.3%, followed by that of from the Liugu River (11.5%), and other nine local rivers below 10%. The COD level in 2005 was worse than that of Grade II seawater and was beyond the environmental capacity. In average, 35% COD reduction is called to meet the standard of Grade I seawater.
基金Supported by National Basic Research Program of China 973 plan (2007CB407305)the Qingdao Special Program for Leading Scientists (05-2-JC-90)the "100 Talents Project" of the Chinese Academy of Sciences
文摘A field observation was carried out in the Changjiang (Yangtze) River Estuary from May 19 to 26, 2003. A total of 29 stations, including 2 anchored stations, were occupied through almost the whole salinity gradient. Based on the observation data, biogeochemistry of chemical oxygen demand (COD) was examined. Spatial distribution pattern of COD shows that it decreased downstream. The COD concentration varied generally within a narrow range of 1.24–1.60 mg/L in the zone around the river mouth, beyond which it decreased rapidly to 0.20 mg/L. In the mixed water zone, the fluctuation in COD was smaller at 2 m above the bottom layer than at the surface layer in 48 h. In the seawater zone, the 48-h fluctuation at the surface was the largest, followed by that of 5 m below the surface and 2 m above the bottom layers in a range of from 2.50 to 0.55 mg/L. Freshwater discharge was the dominant source of COD in the estuary. The average COD beyond the river mouth was 2.7 mg/L, which accorded with the Chinese seawater quality Grade I. Relationships between dissolved oxygen and biogeochemical parameters such as suspended particulate matter, dissolved organic matter and chlorophyll-a were also discussed.
文摘Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts to produce online predictions of the chemical oxygen demand (COD) in wastewater from a pulp and paper mill using NIR spectroscopy are described. The task was perceived as very challenging, but with a root mean square error of prediction of 149 mg/l, roughly corresponding to 1/10 of the studied concentration interval, this attempt was deemed as successful. This result was obtained by using partial least squares model regression, interpolated reference values for calibration purposes, and by evenly distributing the calibration data in the concentration space. This work may also represent the first industrial application of online COD measurements in wastewater using NIR spectroscopy.
文摘To rapidly determine the pollution extent of wastewater, the calibration models were established for deter-mination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater by partial least squares and near infrared spectrometry of 120 samples. Spectral data preprocessing and outliers’ diagnosis were also discussed. Correlation coefficients of the models were 0.9542 and 0.9652, and the root mean square error of prediction (RMSEP) were 25.24 mg?L-1 and 12.13 mg?L-1 in the predicted range of 28.40~528.0 mg?L-1 and 16.0~305.2 mg?L-1 for Chemical Oxygen Demand and Biological Oxygen Demand, respectively. By statistical significance test, the results of determination were compared with those of stan-dard methods with no significant difference at 0.05 level. The method has been applied to simultaneous de-termination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater with satisfactory results.
基金Supported by the National Natural Science Foundation of China(61203099,61034008,61225016)Beijing Science and Technology Project(Z141100001414005)+3 种基金Beijing Science and Technology Special Project(Z141101004414058)Ph.D.Program Foundation from Ministry of Chinese Education(20121103120020)Beijing Nova Program(Z131104000413007)Hong Kong Scholar Program(XJ2013018)
文摘It is difficult to measure the online values of biochemical oxygen demand(BOD) due to the characteristics of nonlinear dynamics, large lag and uncertainty in wastewater treatment process. In this paper, based on the knowledge representation ability and learning capability, an improved T–S fuzzy neural network(TSFNN) is introduced to predict BOD values by the soft computing method. In this improved TSFNN, a K-means clustering is used to initialize the structure of TSFNN, including the number of fuzzy rules and parameters of membership function. For training TSFNN, a gradient descent method with the momentum item is used to adjust antecedent parameters and consequent parameters. This improved TSFNN is applied to predict the BOD values in effluent of the wastewater treatment process. The simulation results show that the TSFNN with K-means clustering algorithm can measure the BOD values accurately. The algorithm presents better approximation performance than some other methods.
文摘This paper presents a method for in situ determining sediment oxygen demand (SOD) in cultivation pond. This method based on sediment surface structure, temperature, and other determining conditions like those in shrimp cultivation environments, overcomes defects of old methods and provides more accurate estimation of SOD’s effect on dissolved oxygen in culture waters. Our experiment shows that the sediment surface structure and temperature had important effect on SOD in culture water. Different SOD values were derived from different parts of oxygen consumption curves of sediment, because the curves were not linear. According to the oxygen consumption curves of sediment and saturated DO in culture water, it was thought more suitable to calculate SOD with dissolved oxygen reduction from 5.0 to 2.0 mg/l. This method to determine the SOD of shrimp ponds yielded satisfactory results.
文摘Various water quality parameters of a leachate pond at an offshore municipal solid waste disposal site were monitored. The pH, dissolved oxygen (DO), and water temperature at the bottom of the leachate pond were measured during Sep. (the 1st period) and Nov.-Dec. (the 2nd period) of 2011. The results suggested that the stratification of water temperature in the pond had gradually broken down due to convection occurring between the end of the 1st period and the 2nd period. The pH was almost constant at 10 - 11 during the 1st period and was approximately 11.5 during the 2nd period. The DO was almost zero during both periods. An anaerobic batch experiment with sampled sediment was undertaken to elucidate the mechanism of material leaching from the sediment. DO decreased under all experimental conditions. With respect to oxidation reduction potential (ORP) and total sulfide in addition to DO, the condition most closely mimicking that of the site became the most anaerobic. The average sediment oxygen demand, SODave, was calculated using a brief numerical model based on batch experiment data. The SODave was 1114.7 mg/m2/d, indicating that at least 434 g/d of oxygen must be supplied to the leachate pond to maintain the DO.
基金Ministry of Science and Technology of China(Nos.2019YFC1805002 and 2018YFC1802300)National Natural Science Foundation of China(Nos.42177118 and 51779219)+1 种基金Basic Science Center Program for Multiphase Evolution in Hypergravity of the National Natural Science Foundation of China(No.51988101)Overseas Expertise Introduction Center for Discipline Innovation(No.B18047),China.
文摘Identification of chemical oxygen demand(COD)in municipal solid waste(MSW)landfill leachates is a challenging problem.This paper investigated the feasibility of using sodium persulfate(PS),a strong oxidant,as a permeable reactive barrier(PRB)filling material.Firstly,sustained-release persulfate balls were manufactured to adjust the release rate of persulfate,the oxidation agent.In addition,Fe(II)-loaded activated carbon(Fe-AC)was used to help with an even distribution of Fe(II)in the porous medium(PRB in this case).Then,the oxidation efficiency and kinetic rate of COD removal by the sustained-release balls were subjected to batch tests.A mass ratio of 1:1.4:0.24:0.7 for PS:cement:sand:water was the most efficient for COD removal(95%).The breakthrough curve for a 5 mm sustained-release ball revealed that the retardation factor was 1.27 and that the hydrodynamic dispersion coefficient was 15.6 cm^(2)/d.The corresponding half-life of COD oxidation was 0.43 d,which was comparable with the half-life of PS release from sustained-release balls(0.56 d).The sustained-release persulfate balls were shown to be an economical material with a simple recipe and production method when catalyzed by Fe-AC.Compared with cutting-edge methods,sustained-release balls used in PRBs offer significant advantages in terms of both effectiveness and economy for the preparation of sustained-release and catalytic materials.These results verified the feasibility of using sustained-release persulfate balls as a PRB material for COD removal.
基金supported by the National Key Research and Development Program of China(No.2020YFB2009000)the National Natural Science Foundation of China(No.22074137).
文摘Eco-friendly chemical oxygen demand(COD)sensors are highly desired with respect to the importance of COD determination in environmental protection.In this work,a new FTO/TiO_(2)/PbO_(2)(FTO=fluorine-doped tin oxide)electrode was fabricated with a two-step method and used as an eco-friendly electrochemical COD sensor.The interlayer TiO_(2)was employed to strengthen the adhesion of PbO_(2)on the FTO substrates by providing a large TiO_(2)/PbO_(2)interface area.The effects of the factors including applied potential,supporting electrolyte concentration and stirring speed on the sensing performance were investigated.Under the optimized conditions,linear responses to the COD of water with different COD sources were achieved,and a linear range from 5 to 120 mg/L was obtained in the case of sucrose as the COD source.The relative standard deviations(RSD)were determined to be less than 9%for the glucose solutions with the COD of 7.5,12.5 and 17.5 mg/L.For real sample analysis,the obtained results were comparable with those measured with the conventional dichromate method,with a relative error less than 11%.
文摘Background:We aimed to investigate risk factors predicting oxygen demand in COVID-19 patients.Methods:Patients admitted to Shizuoka General Hospital with COVID-19 from August 2020 to August 2021 were included.First,we divided patients into groups with and without oxygen demand.Then,we compared patients’clinical characteristics and laboratory and radiological findings to determine factors predicting oxygen demand.Results:One hundred seventy patients with COVID-19(aged 58±15 years,57 females)were enrolled.Common comorbidities were cardiovascular diseases(47.6%),diabetes mellitus(28.8%),and dyslipidemia(26.5%).Elder age,higher body mass index,cardiovascular diseases,diabetes mellitus,lower lymphocyte count,albumin,hep-atic attenuation value,and the liver-to-spleen ratio(L/S),higher D-dimer,aspartate aminotransferase,lactate dehydrogenase,troponin-T,C-reactive protein,KL-6,chest and abdominal circumference,and visceral fat were found in patients with oxygen demand.According to the multivariate logistic regression analysis,L/S,lympho-cyte count,D-dimer,and abdominal circumference under the diaphragm were independent risk factors predicting oxygen demand in COVID-19 patients.Conclusions:On admission,L/S,lymphocyte count,D-dimer,and abdominal circumference were predictive factors for oxygen demand.These factors may help in the appropriate triage of COVID-19 patients in the decision to admit them to the hospital.
基金Project supported by the National Natural Science Foundation of China (No. 20327001), the Key Research & Development Program of China (No. 2004BA210A07).
文摘A photocatalytic oxidation method for determination of chemical oxygen demand (COD) using nano-TiO2 film, based on the use of a nano-TiO2-Ce(SO4)2 system and electrochemical detection, was proposed. The technique was originated from the direct determination of the Ce(Ⅲ) concentration change resulting from photocatalytic oxidation of organic compounds. Ce(Ⅲ), which was produced by photocatalytic reduction of Ce(SO4)2, could be measured at a multi-walled carbon nanotubes (MWNT) chemically modified electrode (CME). The COD values by this method were calculated from the differential pulse voltammetry (DPV) current of Ce(Ⅲ) at the CME. Under the optimal operation conditions, the detection limit of 0.5 mg·L^-1 COD with the linear range of 1-600 mg·L^-1 was achieved. This method was also applied to determination of various COD of ground water and wastewater samples. The resuits were in good agreement with those from the conventional COD methods, i.e., permanganate and dichromate ones.
基金supported by the China Postdoctoral Science Foundation Funded Project (No. 20080430046, 200801093)
文摘Nitrobenzene is an important raw material and product, which presents a heavy threat to the ecosystem. The potential impacts of nitrobenzene on sediment oxygen demand (SOD) were studied in lake sediment simulating reactors receiving relatively low inputs of nitrobenzene. Oxygen microprofiles were measured in these sediment reactors using microelectrodes. After an initial microprofile measurement as a control, nitrobenzene was added to the overlying water resulting in concentrations of 0, 50, 100, and 150 μg/L. Microprofiles were measured on day 1, 2, 4 and 7 following the addition of nitrobenzene. SODs were determined from the microprofiles using a reaction-diffusion model. Results showed that the SODs increased relative to the initial values measured in the pre-treatment period in reactors exposed to all nitrobenzene concentrations on day 1. However, the values decreased gradually on the following days, which eventually resulted in a 50% loss in SODs after 7 days of exposure to nitrobenzene in all reactors. In addition, the inhibition effect of nitrobenzene on SOD exhibited a weak relationship with its concentration. The microscopic observation and count of algae in the sediment showed that the exposure to nitrobenzene did not change the composition of algae greatly, however, it decreased the number of dominant algae species sharply after 7 days of exposure. These results suggested that nitrobenzene could significantly alter SOD in lakes, which could ultimately affect the pollutant recovery in aquatic-sediment systems.
基金supported by the National Basic Science Center of National Natural Science Foundation of China,National Key R&D Program(Grant No.2016YFA0601400)the National Natural Science Foundation of China(Grant Nos.91751207 and 41861144018)。
文摘Chemical oxygen demand(COD)is widely used as an organic pollution indicator in wastewater treatment plants.Large amounts of organic matter are removed during treatment processes to meet environmental standards,and consequently,substantial greenhouse gases(GHGs)such as methane(CH_(4))are released.However,the COD indicator covers a great amount of refractory organic matter that is not a pollutant and could be a potential carbon sink.Here,we collected and analysed COD data from 86 worldwide municipal wastewater treatment plants(WWTPs)and applied a model published by the Intergovernmental Panel on Climate Change to estimate the emission of CH_(4) due to recalcitrant organic compound processing in China’s municipal wastewater treatment systems.Our results showed that the average contribution of refractory COD to total COD removal was55%in 86 WWTPs.The amount of CH_(4) released from the treatment of recalcitrant organic matter in 2018 could have been as high as 38.22 million tons of carbon dioxide equivalent,which amounts to the annual carbon sequestered by China’s wetlands.This suggests that the use of COD as an indicator for organic pollution is undue and needs to be revised to reduce the emission of GHG.In fact,leaving nontoxic recalcitrant organic matter in the wastewater may create a significant carbon sink and will save energy during the treatment process,aiming at carbon neutrality in the wastewater treatment industry.
基金Project(No.7117130553459)supported by the Landeszentralkasse M-V Stipendium,Germany
文摘Evaluating the performance of a biotrickling filter for the treatment of wastewaters produced by a company manufacturing beer was the aim of this study.A pilot scale trickling filter filled with gravel was used as the experimental biofilter.Pilot scale plant experiments were made to evaluate the performance of the trickling filter aerobic and anaerobic biofilm systems for removal of chemical oxygen demand(COD) and nutrients from synthetic brewery wastewater.Performance evaluation data of the trickling filter were generated under different experimental conditions.The trickling filter had an average efficiency of(86.81±6.95)% as the hydraulic loading rate increased from 4.0 to 6.4 m3/(m2·d).Various COD concentrations were used to adjust organic loading rates from 1.5 to 4.5 kg COD/(m3·d).An average COD removal efficiency of(85.10±6.40)% was achieved in all wastewater concentrations at a hydraulic loading of 6.4 m3/(m2·d).The results lead to a design organic load of 1.5 kg COD/(m3·d) to reach an effluent COD in the range of 50–120 mg/L.As can be concluded from the results of this study,organic substances in brewery wastewater can be handled in a cost-effective and environmentally friendly manner using the gravel-filled trickling filter.
基金supported by the Natural Science Foundation of China(No.51979217)。
文摘Sediment oxygen demand(SOD)is a major contributor to hypolimnetic oxygen depletion and the release of internal nutrient loading.By measuring the SOD in experimental chambers using in both dissolved oxygen(DO)depletion and diffusional oxygen transfer methods,a model of SOD for a sediment bed with water current-induced turbulence was presented.An experimental study was also performed using near-sediment vertical DO profiles and correlated hydraulic parameters stimulated using a computational fluid dynamics model to determine how turbulences and DO concentrations in the overlying water affects SOD and diffusive boundary layer thickness.The dependence of the oxygen transfer coefficient and diffusive boundary layer on hydraulic parameters was quantified,and the SOD was expressed as a function of the shear velocity and the bulk DO concentrations.Theoretical predictions were validated using microelectrode measurements in a series of laboratory experiments.This study found that flow over the sediment surface caused an increase in SOD,attributed to enhanced sediment oxygen uptake and reduced substances fluxes,i.e.,for a constant maximum biological oxygen consumption rate,an increased current over the sediment could increase the SOD by 4.5 times compared to stagnant water.These results highlight the importance of considering current-induced SOD increases when designing and implementing aeration/artificial mixing strategies.
基金Project supported by the Foundation of Key Technology Research and Development Program of China (No. 2004 BA210A07) and the National Natural Science Foundation of China (No. 20327001).
文摘A new method for determining chemical oxygen demand (COD) value in water using ion chromatography coupled with nano TiO2-K2S2O8 co-existing system was described. The photocatalytic oxidation system and nano TiO2-K2S2O8 co-existing system could degrade the organic compounds in water. All sulfur-containing species in the reactive solution were eventually transformed to sulfate which could be determined by conductivity detector in ion chromatography. The change of conductivity of sulfate was proportional to COD value. The optimal experimental conditions and the mechanism of the detection were discussed. The application range was 10.0-300.0 mg·L^-1 and the lowest limit of detection was 3.5 mg·L^-1. It was considered that the value obtained could be reliably correlated with the COD value obtained using the conventional methods.