Influence of the combination of nutrient feed with dissolved oxygen control on taxol production in suspension cultures of Taxus chinensis (Pilg.) Rehd. was investigated in bioreactors. Addition of feeding medium with ...Influence of the combination of nutrient feed with dissolved oxygen control on taxol production in suspension cultures of Taxus chinensis (Pilg.) Rehd. was investigated in bioreactors. Addition of feeding medium with 20 g/L sucrose on day 16 enhanced both the biomass and taxol production in 5-L bioreactors. Further investigation of the fed-batch cultures in a 20-L bioreactor showed that cultivation under a low dissolved oxygen tension (DOT) of 20% for the entire culture resulted in the highest taxol content of 0.98 mg/g DW, while the taxol production was lower than that with 40% and 60% DOT. Moreover, taxol accumulation was remarkably improved by the cultivation of cells initially under DOT of 60% for 20 d followed by changing the DOT to 20% for another 12 d. By combining the use of these two strategies, a maximum taxol content of 18.7 mg/L was obtained in a 20-L bioreactor.展开更多
The effect of Fe203 and Liz CO3 additives in flux core on the weld metal oxygen content and weld penetration in self-shielded flux cored arc welding were studied schematically. The result shows that the oxygen content...The effect of Fe203 and Liz CO3 additives in flux core on the weld metal oxygen content and weld penetration in self-shielded flux cored arc welding were studied schematically. The result shows that the oxygen content in the weld metal and weld penetration both increased with the Fe203 addition increased in the range of 5 wt. % to 20 wt. %. The oxygen content in the weld metal was increased with the Li2CO3 addition increased in the range of 1 wt. % to 8 wt. %. However, the weld penetration decreased when Li2CO3 addition exceeding 4 wt. %. High-speed photographic images show that when Fe2O3 addition influx core exceeding 15 wt. %, droplet became excessively large, so that spatters were frequently generated in large numbers. In this study, Fe203 and Li2 CO3 in the amount of 11 wt. % and 4 wt. %, respectively, jointly added in the flux core can achieve a deeper weld penetration with sound usability characteristics.展开更多
The surface tension of molten tin was determined by a set of self-developed digital equipment with sessile drop method at oxygen partial pressure of 1.0×10 -6MPa under different temperatures, and the dependence...The surface tension of molten tin was determined by a set of self-developed digital equipment with sessile drop method at oxygen partial pressure of 1.0×10 -6MPa under different temperatures, and the dependence of surface tension of molten tin on temperature was also discussed. The emphasis was placed on the comparison of surface tension of the same molten tin sample measured by using different equipments with sessile drop method. Results of the comparison indicate that the measurement results with sessile drop method under the approximate experimental conditions are coincident, and the self-developed digital equipment for surface tension measurement has higher stability and accuracy. The relationships of surface tension of molten tin and its temperature coefficient with temperature and oxygen partial pressure were also elucidated from the thermodynamic equilibrium analysis.展开更多
The mixed venous-to-arterial carbon dioxide(CO_2)tension difference[P(v-a) CO_2]is the difference between carbon dioxide tension(PCO_2) in mixed venous blood(sampled from a pulmonary artery catheter) and the PCO_2 in ...The mixed venous-to-arterial carbon dioxide(CO_2)tension difference[P(v-a) CO_2]is the difference between carbon dioxide tension(PCO_2) in mixed venous blood(sampled from a pulmonary artery catheter) and the PCO_2 in arterial blood.P(v-a) CO_2 depends on the cardiac output and the global CO_2 production,and on the complex relationship between PCO_2 and CO_2 content.Experimental and clinical studies support the evidence that P(v-a) CO_2 cannot serve as an indicator of tissue hypoxia,and should be regarded as an indicator of the adequacy of venous blood to wash out the total CO_2generated by the peripheral tissues.P(v-a) CO_2 can be replaced by the central venous-to-arterial CO_2 difference(△PCO_2),which is calculated from simultaneous sampling of central venous blood from a central vein catheter and arterial blood and,therefore,more easy to obtain at the bedside.Determining the △PCO_2 during the resuscitation of septic shock patients might be useful when deciding when to continue resuscitation despite a central venous oxygen saturation(SCVO_2) > 70%associated with elevated blood lactate levels.Because high blood lactate levels is not a discriminatory factor in determining the source of that stress,an increased △PCO_2(> 6 mmHg)could be used to identify patients who still remain inadequately resuscitated.Monitoring the △PCO_2 from the beginning of the reanimation of septic shock patients might be a valuable means to evaluate the adequacy of cardiac output in tissue perfusion and,thus,guiding the therapy.In this respect,it can aid to titrate inotropes to adjust oxygen delivery to CO_2 production,or to choose between hemoglobin correction or fluid/inotrope infusion in patients with a too low ScvO_2 related to metabolic demand.The combination of P(v-a) CO_2 or △PCO_2 with oxygen-derived parameters through the calculation of the P(v-a) CO_2 or △PCO_2/arteriovenous oxygen content difference ratio can detect the presence of global anaerobic metabolism.展开更多
In this paper a method has been proposed for the calculation of cohesive work and thus sur-face tension of liquids by the Monte Carlo computer simulation method with the use of Kihara po-tential. The surface tension v...In this paper a method has been proposed for the calculation of cohesive work and thus sur-face tension of liquids by the Monte Carlo computer simulation method with the use of Kihara po-tential. The surface tension values calculated for liquid argon, oxygen and nitrogen are in fairagreement with the experimental data.展开更多
文摘Influence of the combination of nutrient feed with dissolved oxygen control on taxol production in suspension cultures of Taxus chinensis (Pilg.) Rehd. was investigated in bioreactors. Addition of feeding medium with 20 g/L sucrose on day 16 enhanced both the biomass and taxol production in 5-L bioreactors. Further investigation of the fed-batch cultures in a 20-L bioreactor showed that cultivation under a low dissolved oxygen tension (DOT) of 20% for the entire culture resulted in the highest taxol content of 0.98 mg/g DW, while the taxol production was lower than that with 40% and 60% DOT. Moreover, taxol accumulation was remarkably improved by the cultivation of cells initially under DOT of 60% for 20 d followed by changing the DOT to 20% for another 12 d. By combining the use of these two strategies, a maximum taxol content of 18.7 mg/L was obtained in a 20-L bioreactor.
文摘The effect of Fe203 and Liz CO3 additives in flux core on the weld metal oxygen content and weld penetration in self-shielded flux cored arc welding were studied schematically. The result shows that the oxygen content in the weld metal and weld penetration both increased with the Fe203 addition increased in the range of 5 wt. % to 20 wt. %. The oxygen content in the weld metal was increased with the Li2CO3 addition increased in the range of 1 wt. % to 8 wt. %. However, the weld penetration decreased when Li2CO3 addition exceeding 4 wt. %. High-speed photographic images show that when Fe2O3 addition influx core exceeding 15 wt. %, droplet became excessively large, so that spatters were frequently generated in large numbers. In this study, Fe203 and Li2 CO3 in the amount of 11 wt. % and 4 wt. %, respectively, jointly added in the flux core can achieve a deeper weld penetration with sound usability characteristics.
文摘The surface tension of molten tin was determined by a set of self-developed digital equipment with sessile drop method at oxygen partial pressure of 1.0×10 -6MPa under different temperatures, and the dependence of surface tension of molten tin on temperature was also discussed. The emphasis was placed on the comparison of surface tension of the same molten tin sample measured by using different equipments with sessile drop method. Results of the comparison indicate that the measurement results with sessile drop method under the approximate experimental conditions are coincident, and the self-developed digital equipment for surface tension measurement has higher stability and accuracy. The relationships of surface tension of molten tin and its temperature coefficient with temperature and oxygen partial pressure were also elucidated from the thermodynamic equilibrium analysis.
文摘The mixed venous-to-arterial carbon dioxide(CO_2)tension difference[P(v-a) CO_2]is the difference between carbon dioxide tension(PCO_2) in mixed venous blood(sampled from a pulmonary artery catheter) and the PCO_2 in arterial blood.P(v-a) CO_2 depends on the cardiac output and the global CO_2 production,and on the complex relationship between PCO_2 and CO_2 content.Experimental and clinical studies support the evidence that P(v-a) CO_2 cannot serve as an indicator of tissue hypoxia,and should be regarded as an indicator of the adequacy of venous blood to wash out the total CO_2generated by the peripheral tissues.P(v-a) CO_2 can be replaced by the central venous-to-arterial CO_2 difference(△PCO_2),which is calculated from simultaneous sampling of central venous blood from a central vein catheter and arterial blood and,therefore,more easy to obtain at the bedside.Determining the △PCO_2 during the resuscitation of septic shock patients might be useful when deciding when to continue resuscitation despite a central venous oxygen saturation(SCVO_2) > 70%associated with elevated blood lactate levels.Because high blood lactate levels is not a discriminatory factor in determining the source of that stress,an increased △PCO_2(> 6 mmHg)could be used to identify patients who still remain inadequately resuscitated.Monitoring the △PCO_2 from the beginning of the reanimation of septic shock patients might be a valuable means to evaluate the adequacy of cardiac output in tissue perfusion and,thus,guiding the therapy.In this respect,it can aid to titrate inotropes to adjust oxygen delivery to CO_2 production,or to choose between hemoglobin correction or fluid/inotrope infusion in patients with a too low ScvO_2 related to metabolic demand.The combination of P(v-a) CO_2 or △PCO_2 with oxygen-derived parameters through the calculation of the P(v-a) CO_2 or △PCO_2/arteriovenous oxygen content difference ratio can detect the presence of global anaerobic metabolism.
文摘In this paper a method has been proposed for the calculation of cohesive work and thus sur-face tension of liquids by the Monte Carlo computer simulation method with the use of Kihara po-tential. The surface tension values calculated for liquid argon, oxygen and nitrogen are in fairagreement with the experimental data.