One commonly used strategy to enhance polymers specific properties such as the resistance to partial discharges erosion is the incorporation into the polymeric matrix of inorganic micro or nanoparticles. This study fo...One commonly used strategy to enhance polymers specific properties such as the resistance to partial discharges erosion is the incorporation into the polymeric matrix of inorganic micro or nanoparticles. This study focused on the dielectric properties of Low-Density Polyethylene (LDPE) filled with nano-sized Magnesium Oxide (MgO) particles compounded by thermo-mechanical process and one of the purposes was to establish appropriate processing parameters in order to reach the desired dielectric properties. LDPE was used as a matrix and was reinforced by MgO particles having a nominal average size of 30 nm. The MgO nanoparticles were treated with a silane coupling agent (3-Glycidyloxypropyl Trimethoxysilane). The samples were initially prepared in a melt-mixing chamber with a MgO content of 1% wt. These pre-mixed samples were further treated by the means of thermo-mechanical mixing in a conical co-rotating twin-screw extruder in order to improve the dispersion and distribution of the MgO particles. In this report, both lifetime under a PD activity and AC dielectric strength of pure and nano-filled LDPE samples have been measured and compared. Nano-filled LDPE samples were found to exhibit an improve lifetime, without any detrimental impact on their short-term dielectric strength. This suggests that nano-filled LDPE may be for electric applications for which the dielectric materials may be exposed to partial discharge activities. This is significant result for the use of MgO-reinforced PE as an insulating material for HV cables since the resistance to PD is closely related to treeing resistance which is the main electrical degradation mechanism that leads to failure for shielded extruded power cables.展开更多
Efforts to protect electric power systems from faults have commonly relied on the use of ultra-high frequency(UHF)antennas for detecting partial discharge(PD)as a common precursor to faults.However,the effectiveness o...Efforts to protect electric power systems from faults have commonly relied on the use of ultra-high frequency(UHF)antennas for detecting partial discharge(PD)as a common precursor to faults.However,the effectiveness of existing UHF antennas suffers from a number of challenges such as limited bandwidth,relatively large physical size,and low detection sensitivity.The present study addresses these issues by proposing a compact microstrip patch antenna with fixed dimensions of 100 mm×100 mm×1.6 mm.The results of computations yield an optimized antenna design consisting of 2nd-order Hilbert fractal units positioned within a four-layer serpentine arrangement with a fractal unit connection distance of 3.0 mm.Specifically,the optimized antenna design achieves a detection bandwidth for which the voltage standing wave ratio is less than 2 that is approximately 97.3%of the UHF frequency range(0.3–3 GHz).Finally,a prototype antenna is fabricated using standard printed circuit board technology,and the results of experiments demonstrate that the proposed antenna is capable of detecting PD signals at a distance of 8 m from the discharge source.展开更多
The reliability of gas-insulated switchgear(GIS)partial discharge fault diagnosis is crucial for the safe and stable operation of power grids.This study proposed a data enhancement method based on a self-attention mec...The reliability of gas-insulated switchgear(GIS)partial discharge fault diagnosis is crucial for the safe and stable operation of power grids.This study proposed a data enhancement method based on a self-attention mechanism to optimize the VAE-GAN method and solve the problem of the lack of partial discharge samples and the unbalanced distribution between different defects.First,the non-subsampled contourlet transform(NSCT)algorithm was used to fuse the UHF and optical partial discharge signals to obtain a photoelectric fusion phase resolved partial discharge(PRPD)spectrum with richer information.Subsequently,the VAE structure was introduced into the traditional GAN,and the excellent hidden layer feature extraction ability of the VAE was used to guide the generation of the GAN.Then,the self-attention mechanism was integrated into the VAE-GAN,and the Wasserstein distance and gradient penalty mechanisms were used to optimize the network loss function and expand the sample sets to an equilibrium state.Finally,the KAZE and polar coordinate distribution entropy methods were used to extract the expanded samples.The eigenvectors of the sets were substituted into the long short-term memory(LSTM)network for partial discharge fault diagnosis.The experimental results show that the sample generation quality and fault diagnosis results of this method were significantly better than the traditional data enhancement method.The structure similarity index measure(SSIM)index is increased by 4.5%and 21.7%,respectively,and the average accuracy of fault diagnosis is increased by 22.9%,9%,5.7%,and 6.5%,respectively.The data enhancement method proposed in this study can provide a reference for GIS partial discharge fault diagnosis.展开更多
The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a nu...The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a number of simulations. The simulations were based on the well-known three capacitor model for partial discharge. An equivalent circuit was derived for partial discharge due to a single void in the insulation material of a power cable. The results obtained from the simulations will form the basis of the design proses of a non-intrusive condition monitoring technique. The technique is based on the classification of discharge activity according to five levels of PD. Future work will include the improvement of the simulation model by investigating the high frequency model of a power cable as well as the statistical nature of PD activity. This will improve the accuracy of the simulation results when compared to actual measurements. The work discussed in this paper will be used to construct and calibrate a practical model which will make use of PD measurements for non-intrusive condition monitoring of medium voltage electrical cables.展开更多
Expounds a partial discharge detection circuit and a microcomputer based partial discharge monitoring system. The importance of statistical phase position distribution of partial discharge events for failure diagnosi...Expounds a partial discharge detection circuit and a microcomputer based partial discharge monitoring system. The importance of statistical phase position distribution of partial discharge events for failure diagnosis of power transformer and discusses an artificial neural network trained with φ q patterns for pattern recognition of partial discharge is discussed in detail, which is proved to be effective for on line monitoring.展开更多
The acoustic emission(AE)method has been widely recognized for the detection of incipient insulation fault phenomenon(partial discharge,PD)in power transfomiers,nevertheless,the installation and placement of AE sensor...The acoustic emission(AE)method has been widely recognized for the detection of incipient insulation fault phenomenon(partial discharge,PD)in power transfomiers,nevertheless,the installation and placement of AE sensors should be taken into full consideration.In this manuscript,a three-dimensional multiphysics model was established and simulated to research the characteristics of the propagation in the transformer wall.Furthermore,a piezoelectric transducer was used to detect PD ultrasonic signals and verify the simulation results in the laboratory.To ensure the accuracy of the detection,an optical fiber sensor based on the Sagnac interference principle was designed and adopted.The variation of the amplitude of the ultrasonic signal with distance reveals the characteristics of the ultrasonic signal propagating in the transformer wall.The distribution of sound pressure on the upper and lower surfaces of the simulation model proved that ultrasonic waves propagate in the form of symmetrical Lamb waves in the transformer wall.Moreover,the amplitude of the AE attenuates due to absorption and refraction loss,and local fluctuations on account of acoustic interference.Thus,a stable signal detected by an AE sensor does not represent the absence of PD in a transfomier.To improve the reliability of AE detection,it is proposed in this manuscript that repeated movement of the AE sensor is necessary to obtain a suitable measurement position.Similarly,it is necessary to adjust the position of the AE sensor in order to locate the PD source well.In addition,this study is expected to provide a theoretical analysis and a fiber sensor to address the problem of sensor placement in AE detection.展开更多
HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics...HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics of HFO-1234 ze(E)/N2 mixtures were studied using the gas insulation test platform.The PD inception voltage of insulating gas under positive and negative half cycles of power frequency was tested.Using SF6/N2 mixtures as a control group,the effects of electrode spacing,mixing ratio and pressure on the insulation performance of HFO-1234 ze(E)/N2 mixtures were explored.The test results show that the PD inception voltage of the negative half-cycle of pure HFO-1234 ze(E)under short electrode spacing can reach 0.96-1.04 times of pure SF6 under different pressures;the PD inception voltage of40%HFO-1234 ze(E)/60%N2 mixtures at 0.3 MPa is 0.67-0.89 times that of SF6/N2 mixtures under the same conditions,which has great application prospect.展开更多
Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltag...Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltage. The result is then extrapolated linearly, leading to an error related to the distribution of stray capacitance, which varies with the testing frequency, especially to large transformers. In this paper a factor, named the capacitive rise fact, is introduced to assess the rise. The factor can be adjusted to some extent by changing the reactance that is connected to the LV side of the testing circuit to lower the capacity of the power source. However, the factor changes when the voltage divider on the high voltage side is removed after the voltage ratio has been calculated, and a great error is resulted under unfavorable conditios.展开更多
In response to the problem of frequent leakage and false alarm of partial discharge insulation defects in GIS,this paper conducts experimental research on intermittent discharge characteristics of common solid insulat...In response to the problem of frequent leakage and false alarm of partial discharge insulation defects in GIS,this paper conducts experimental research on intermittent discharge characteristics of common solid insulation defects in GIS.Using true GIS to build amulti-source testing platform for intermittent discharge of solid insulation defects,and using pulse current method,ultra-high frequency method,ultrasonic method,and gas characteristic component detectionmethod to study the variation law of intermittent discharge characteristics of solid insulation defects.The results showthat:the intermittent discharge state of metal fouling defects on the solid insulation surface decreases with the extension of the discharge time,the discharge time interval as a whole shows an increasing trend,and the metal fouling defects on the solid insulation surface in the intermittent discharge state is difficult to develop into a breakdown discharge fault.The overall discharge amount of air gap defects inside solid insulation also shows the law of increasing first and then decreasing,and the discharge amount of air gap defects inside solid insulation stays at a large level for a long time during intermittent discharge,and there is a risk of breakdown,and the discharge will gradually evolve into continuous discharge;ultrasonic method and characteristic component detection method cannot realize the effective perception of intermittent discharge of metal fouling.The 50-period mapping information commonly used in the power field cannot reflect the intermittent discharge variation law of solid insulation,and the 200-period UHF mapping composed of four groups of 50-period UHF mapping data can initially derive the intermittent discharge distribution law of solid insulation defects.The research results of this paper are of great significance to expand the knowledge of intermittent discharge characteristics and the detection of GIS discharge defects in the field.展开更多
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ...Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.展开更多
This paper studies on the Partial Discharge (PD) Locating System based on a mobile array of ultra-high frequency (UHF) antennas and a vehicle-mounted PD locating system is established. The system consists of omni-dire...This paper studies on the Partial Discharge (PD) Locating System based on a mobile array of ultra-high frequency (UHF) antennas and a vehicle-mounted PD locating system is established. The system consists of omni-directional antenna array for receiving UHF PD signals, a pre-processing circuit for signal amplification and filtering and the high- speed acquisition and control unit of PD pulse signals. The developed locating system is able to simultaneously record the PD pulse signals received by the antenna array. By assessing the time difference of arrival (TDOA), the two-dimensional hyperbolic locating model quickly locates the PD source. Based on the software developed by LabVIEW, it is also possible to display, store and further analyze the acquired signals. Through the simulation of PD signals and the locating experiments with the system, it is proved that the PD locating system possesses the features of rapidity and precision in determining the bearing of PD source.展开更多
A balancing method was used to build a DC partial discharge (PD) testing circuit for electrical equipment,and a narrow-band detection system was designed using detection resistance and a filter. After signal accesse...A balancing method was used to build a DC partial discharge (PD) testing circuit for electrical equipment,and a narrow-band detection system was designed using detection resistance and a filter. After signal accessed a high-speed digital acquisition (DAQ) card,the system was triggered to extract a single partial discharge (PD) signal. To eliminate the interference pulses caused by power supply ripple,etc.,the time domain and frequency domain features of pulses were extracted. Based on the features,cluster analysis was used to exclude interference pulses. Two-dimensional and three-dimensional histograms were obtained by use of the Δt method. Then,22 discharge statistical operators were calculated for the two-dimensional charts. Lastly,the defective capacitors were tested to verify the system's ability. The results show that the system is capable of PD detection in electrical equipment.展开更多
Packed-bed reactors(PBRs)hold great promise for environmental applications,but a deeper understanding of the behavior of plasma discharge within PBRs is required.To this end,a partial-discharge alternative equivalent ...Packed-bed reactors(PBRs)hold great promise for environmental applications,but a deeper understanding of the behavior of plasma discharge within PBRs is required.To this end,a partial-discharge alternative equivalent circuit for PBRs was established in this work.Dielectric particles(glass beads or glass sand)were used to place focus on the effects of the particle size and shape on the partial discharge behavior of the oxygen PBRs.Some electrical characterizations were explored(e.g.the effective dielectric capacitance,partial discharge coefficient,and corrected burning voltage)that may differ from long-standing interpretations.The findings indicate that the suppressive effect of surface discharge on filament discharge is stronger with the decrease of the particle size.For partial discharge,the effective dielectric capacitance is always less than the dielectric capacitance.The corrected burning voltage and partial discharge tendency increase with the decrease of the particle size.As compared to an empty reactor,the average electric field in the PBR was found to be improved by 3–4 times,and the ozone energy efficiency and production were promoted by more than 20%and 15%,respectively.The plasma processing capacity can therefore be improved by choosing a relatively large size or a complex,irregularly-shaped packing material that is suitable for the discharge gap.展开更多
On-line partial discharge(PD)detection still remains a very challenging task because of the strong electromagnetic interferences.In this paper,a new method of de-noising,using complex Daubechies wavelet(CDW)transform,...On-line partial discharge(PD)detection still remains a very challenging task because of the strong electromagnetic interferences.In this paper,a new method of de-noising,using complex Daubechies wavelet(CDW)transform,has been proposed.It is a relatively recent enhancement to the real-valued wavelet transform because of tow important properties,which are nearly shift-invariant and availability of phase information.Those properties give CDW transform superiority over other real-valued wavelet transform,and then the construction algorithm of CDW is introduced in detail.Secondly,based on the real threshold algorithm of real-valued wavelet transform,complex threshold algorithm is devised.This algorithm take the different characteristics of real part and imaginary part of complex wavelet coefficients into account,it modifies the real and imaginary parts of complex wavelet coefficients respectively.Thirdly,to obtain a real de-noised signal,new combined information series is devised.By applying different combination of real part and imaginary part of de-noised complex signal,a real de-noised signal can be restored with higher peak signal-to-noise ratio(PSNR)and less distortion of original signals.Finally,On-site applications of extracting PD signals from noisy background by the optimal de-noising scheme based on CDW are illustrated.The on-site experimental results show that the optimal de-noising scheme is an effective way to suppress white noise in PD measurement.展开更多
This paper introduces a new method to separate PD1 from other disturbing signals present on the high voltage genera-tors and motors. The method is based on combination of a pattern classifier, the Discrete Wavelet Tra...This paper introduces a new method to separate PD1 from other disturbing signals present on the high voltage genera-tors and motors. The method is based on combination of a pattern classifier, the Discrete Wavelet Transform (DWT), to de-noise PD and Time-Of-Arrival method to separate PD sources. Furthermore, it will be shown that it can recognize PD sources including rotating machine’s internal and external discharge pulses (e.g. on the bus bar).展开更多
Partial discharge(PD)is an important reason for the insulation failure of the switchgear.In the process of PD detection,PD signal is often annihilated in strong noise.In order to improve the accuracy of PD detection i...Partial discharge(PD)is an important reason for the insulation failure of the switchgear.In the process of PD detection,PD signal is often annihilated in strong noise.In order to improve the accuracy of PD detection in power plant switchgear,a method based on continuous adaptive wavelet threshold switchgear PD signals denoising is proposed in this paper.By constructing a continuous adaptive threshold function and introducing adjustment parameters,the problems of over⁃processing of traditional hard threshold functions and incomplete denoising of soft threshold functions can be improved.The analysis results of simulated signals and measured signals show that the continuous adaptive wavelet threshold denoising method is significantly better than the traditional denoising method for the PD signal.The proposed method in this paper retains the characteristics of the original signal.Compared with the traditional denoising methods,after denoising the simulated signals,the signal⁃to⁃noise ratio(SNR)is increased by more than 30%,and the root⁃mean⁃square error(RMSE)is reduced by more than 30%.After denoising the real signal,the noise suppression ratio(NRR)is increased by more than 40%.The recognition accuracy rate of PD signal has also been improved to a certain extent,which proves that the method has a certain practicability.展开更多
Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the sta...Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the statistical function. Thus, we developed a test system for PD detection under DC voltage, which is characterized by strong anti-jamming capability, continuous high-speed real-time data acquisi- tion and effective, complete detection of DC PD signals. The DC PD mechanism, as well as the measuring principles, software system, and hardware design of the test equipment were introduced. Adopting typical electrode pairs, we tested the statistical spectrum of PD under DC voltage. The main difference in statistical spectrums between parallel plate electrodes and needle-plate electrodes was that the time interval between two consecutive discharges for needle-plate electrodes has obviously larger variation range than that for parallel plate electrodes, which could be the convincing proof for distinguishing the type of electrodes under DC PD. Practical results indicate that the proposed sys- tem can measure time domain signals of DC PD of oil-paper insulation effectively and promptly, and it can be used to determine and detect defects in DC power transmission equipment.展开更多
文摘One commonly used strategy to enhance polymers specific properties such as the resistance to partial discharges erosion is the incorporation into the polymeric matrix of inorganic micro or nanoparticles. This study focused on the dielectric properties of Low-Density Polyethylene (LDPE) filled with nano-sized Magnesium Oxide (MgO) particles compounded by thermo-mechanical process and one of the purposes was to establish appropriate processing parameters in order to reach the desired dielectric properties. LDPE was used as a matrix and was reinforced by MgO particles having a nominal average size of 30 nm. The MgO nanoparticles were treated with a silane coupling agent (3-Glycidyloxypropyl Trimethoxysilane). The samples were initially prepared in a melt-mixing chamber with a MgO content of 1% wt. These pre-mixed samples were further treated by the means of thermo-mechanical mixing in a conical co-rotating twin-screw extruder in order to improve the dispersion and distribution of the MgO particles. In this report, both lifetime under a PD activity and AC dielectric strength of pure and nano-filled LDPE samples have been measured and compared. Nano-filled LDPE samples were found to exhibit an improve lifetime, without any detrimental impact on their short-term dielectric strength. This suggests that nano-filled LDPE may be for electric applications for which the dielectric materials may be exposed to partial discharge activities. This is significant result for the use of MgO-reinforced PE as an insulating material for HV cables since the resistance to PD is closely related to treeing resistance which is the main electrical degradation mechanism that leads to failure for shielded extruded power cables.
文摘Efforts to protect electric power systems from faults have commonly relied on the use of ultra-high frequency(UHF)antennas for detecting partial discharge(PD)as a common precursor to faults.However,the effectiveness of existing UHF antennas suffers from a number of challenges such as limited bandwidth,relatively large physical size,and low detection sensitivity.The present study addresses these issues by proposing a compact microstrip patch antenna with fixed dimensions of 100 mm×100 mm×1.6 mm.The results of computations yield an optimized antenna design consisting of 2nd-order Hilbert fractal units positioned within a four-layer serpentine arrangement with a fractal unit connection distance of 3.0 mm.Specifically,the optimized antenna design achieves a detection bandwidth for which the voltage standing wave ratio is less than 2 that is approximately 97.3%of the UHF frequency range(0.3–3 GHz).Finally,a prototype antenna is fabricated using standard printed circuit board technology,and the results of experiments demonstrate that the proposed antenna is capable of detecting PD signals at a distance of 8 m from the discharge source.
文摘The reliability of gas-insulated switchgear(GIS)partial discharge fault diagnosis is crucial for the safe and stable operation of power grids.This study proposed a data enhancement method based on a self-attention mechanism to optimize the VAE-GAN method and solve the problem of the lack of partial discharge samples and the unbalanced distribution between different defects.First,the non-subsampled contourlet transform(NSCT)algorithm was used to fuse the UHF and optical partial discharge signals to obtain a photoelectric fusion phase resolved partial discharge(PRPD)spectrum with richer information.Subsequently,the VAE structure was introduced into the traditional GAN,and the excellent hidden layer feature extraction ability of the VAE was used to guide the generation of the GAN.Then,the self-attention mechanism was integrated into the VAE-GAN,and the Wasserstein distance and gradient penalty mechanisms were used to optimize the network loss function and expand the sample sets to an equilibrium state.Finally,the KAZE and polar coordinate distribution entropy methods were used to extract the expanded samples.The eigenvectors of the sets were substituted into the long short-term memory(LSTM)network for partial discharge fault diagnosis.The experimental results show that the sample generation quality and fault diagnosis results of this method were significantly better than the traditional data enhancement method.The structure similarity index measure(SSIM)index is increased by 4.5%and 21.7%,respectively,and the average accuracy of fault diagnosis is increased by 22.9%,9%,5.7%,and 6.5%,respectively.The data enhancement method proposed in this study can provide a reference for GIS partial discharge fault diagnosis.
文摘The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a number of simulations. The simulations were based on the well-known three capacitor model for partial discharge. An equivalent circuit was derived for partial discharge due to a single void in the insulation material of a power cable. The results obtained from the simulations will form the basis of the design proses of a non-intrusive condition monitoring technique. The technique is based on the classification of discharge activity according to five levels of PD. Future work will include the improvement of the simulation model by investigating the high frequency model of a power cable as well as the statistical nature of PD activity. This will improve the accuracy of the simulation results when compared to actual measurements. The work discussed in this paper will be used to construct and calibrate a practical model which will make use of PD measurements for non-intrusive condition monitoring of medium voltage electrical cables.
文摘Expounds a partial discharge detection circuit and a microcomputer based partial discharge monitoring system. The importance of statistical phase position distribution of partial discharge events for failure diagnosis of power transformer and discusses an artificial neural network trained with φ q patterns for pattern recognition of partial discharge is discussed in detail, which is proved to be effective for on line monitoring.
文摘The acoustic emission(AE)method has been widely recognized for the detection of incipient insulation fault phenomenon(partial discharge,PD)in power transfomiers,nevertheless,the installation and placement of AE sensors should be taken into full consideration.In this manuscript,a three-dimensional multiphysics model was established and simulated to research the characteristics of the propagation in the transformer wall.Furthermore,a piezoelectric transducer was used to detect PD ultrasonic signals and verify the simulation results in the laboratory.To ensure the accuracy of the detection,an optical fiber sensor based on the Sagnac interference principle was designed and adopted.The variation of the amplitude of the ultrasonic signal with distance reveals the characteristics of the ultrasonic signal propagating in the transformer wall.The distribution of sound pressure on the upper and lower surfaces of the simulation model proved that ultrasonic waves propagate in the form of symmetrical Lamb waves in the transformer wall.Moreover,the amplitude of the AE attenuates due to absorption and refraction loss,and local fluctuations on account of acoustic interference.Thus,a stable signal detected by an AE sensor does not represent the absence of PD in a transfomier.To improve the reliability of AE detection,it is proposed in this manuscript that repeated movement of the AE sensor is necessary to obtain a suitable measurement position.Similarly,it is necessary to adjust the position of the AE sensor in order to locate the PD source well.In addition,this study is expected to provide a theoretical analysis and a fiber sensor to address the problem of sensor placement in AE detection.
文摘HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics of HFO-1234 ze(E)/N2 mixtures were studied using the gas insulation test platform.The PD inception voltage of insulating gas under positive and negative half cycles of power frequency was tested.Using SF6/N2 mixtures as a control group,the effects of electrode spacing,mixing ratio and pressure on the insulation performance of HFO-1234 ze(E)/N2 mixtures were explored.The test results show that the PD inception voltage of the negative half-cycle of pure HFO-1234 ze(E)under short electrode spacing can reach 0.96-1.04 times of pure SF6 under different pressures;the PD inception voltage of40%HFO-1234 ze(E)/60%N2 mixtures at 0.3 MPa is 0.67-0.89 times that of SF6/N2 mixtures under the same conditions,which has great application prospect.
文摘Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltage. The result is then extrapolated linearly, leading to an error related to the distribution of stray capacitance, which varies with the testing frequency, especially to large transformers. In this paper a factor, named the capacitive rise fact, is introduced to assess the rise. The factor can be adjusted to some extent by changing the reactance that is connected to the LV side of the testing circuit to lower the capacity of the power source. However, the factor changes when the voltage divider on the high voltage side is removed after the voltage ratio has been calculated, and a great error is resulted under unfavorable conditios.
基金Project supported by Science and Technology Project of SGCC(Research on Key Technologies for Fault Diagnosis and Early Warning of Intermittent Discharge in UHV GIS:524625200028).
文摘In response to the problem of frequent leakage and false alarm of partial discharge insulation defects in GIS,this paper conducts experimental research on intermittent discharge characteristics of common solid insulation defects in GIS.Using true GIS to build amulti-source testing platform for intermittent discharge of solid insulation defects,and using pulse current method,ultra-high frequency method,ultrasonic method,and gas characteristic component detectionmethod to study the variation law of intermittent discharge characteristics of solid insulation defects.The results showthat:the intermittent discharge state of metal fouling defects on the solid insulation surface decreases with the extension of the discharge time,the discharge time interval as a whole shows an increasing trend,and the metal fouling defects on the solid insulation surface in the intermittent discharge state is difficult to develop into a breakdown discharge fault.The overall discharge amount of air gap defects inside solid insulation also shows the law of increasing first and then decreasing,and the discharge amount of air gap defects inside solid insulation stays at a large level for a long time during intermittent discharge,and there is a risk of breakdown,and the discharge will gradually evolve into continuous discharge;ultrasonic method and characteristic component detection method cannot realize the effective perception of intermittent discharge of metal fouling.The 50-period mapping information commonly used in the power field cannot reflect the intermittent discharge variation law of solid insulation,and the 200-period UHF mapping composed of four groups of 50-period UHF mapping data can initially derive the intermittent discharge distribution law of solid insulation defects.The research results of this paper are of great significance to expand the knowledge of intermittent discharge characteristics and the detection of GIS discharge defects in the field.
文摘Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.
文摘This paper studies on the Partial Discharge (PD) Locating System based on a mobile array of ultra-high frequency (UHF) antennas and a vehicle-mounted PD locating system is established. The system consists of omni-directional antenna array for receiving UHF PD signals, a pre-processing circuit for signal amplification and filtering and the high- speed acquisition and control unit of PD pulse signals. The developed locating system is able to simultaneously record the PD pulse signals received by the antenna array. By assessing the time difference of arrival (TDOA), the two-dimensional hyperbolic locating model quickly locates the PD source. Based on the software developed by LabVIEW, it is also possible to display, store and further analyze the acquired signals. Through the simulation of PD signals and the locating experiments with the system, it is proved that the PD locating system possesses the features of rapidity and precision in determining the bearing of PD source.
文摘A balancing method was used to build a DC partial discharge (PD) testing circuit for electrical equipment,and a narrow-band detection system was designed using detection resistance and a filter. After signal accessed a high-speed digital acquisition (DAQ) card,the system was triggered to extract a single partial discharge (PD) signal. To eliminate the interference pulses caused by power supply ripple,etc.,the time domain and frequency domain features of pulses were extracted. Based on the features,cluster analysis was used to exclude interference pulses. Two-dimensional and three-dimensional histograms were obtained by use of the Δt method. Then,22 discharge statistical operators were calculated for the two-dimensional charts. Lastly,the defective capacitors were tested to verify the system's ability. The results show that the system is capable of PD detection in electrical equipment.
基金supported by National Natural Science Foundation of China(Nos.51806085,51676089)China Postdoctoral Science Foundation(2018M642175)the Double Innovation Talents of Jiangsu Province and Jiangsu University Youth Talent Cultivation Program Funded Project
文摘Packed-bed reactors(PBRs)hold great promise for environmental applications,but a deeper understanding of the behavior of plasma discharge within PBRs is required.To this end,a partial-discharge alternative equivalent circuit for PBRs was established in this work.Dielectric particles(glass beads or glass sand)were used to place focus on the effects of the particle size and shape on the partial discharge behavior of the oxygen PBRs.Some electrical characterizations were explored(e.g.the effective dielectric capacitance,partial discharge coefficient,and corrected burning voltage)that may differ from long-standing interpretations.The findings indicate that the suppressive effect of surface discharge on filament discharge is stronger with the decrease of the particle size.For partial discharge,the effective dielectric capacitance is always less than the dielectric capacitance.The corrected burning voltage and partial discharge tendency increase with the decrease of the particle size.As compared to an empty reactor,the average electric field in the PBR was found to be improved by 3–4 times,and the ozone energy efficiency and production were promoted by more than 20%and 15%,respectively.The plasma processing capacity can therefore be improved by choosing a relatively large size or a complex,irregularly-shaped packing material that is suitable for the discharge gap.
基金Project Supported by National Natural Science Foundation China(50577069), National Grid Company (2004-SGKJ).
文摘On-line partial discharge(PD)detection still remains a very challenging task because of the strong electromagnetic interferences.In this paper,a new method of de-noising,using complex Daubechies wavelet(CDW)transform,has been proposed.It is a relatively recent enhancement to the real-valued wavelet transform because of tow important properties,which are nearly shift-invariant and availability of phase information.Those properties give CDW transform superiority over other real-valued wavelet transform,and then the construction algorithm of CDW is introduced in detail.Secondly,based on the real threshold algorithm of real-valued wavelet transform,complex threshold algorithm is devised.This algorithm take the different characteristics of real part and imaginary part of complex wavelet coefficients into account,it modifies the real and imaginary parts of complex wavelet coefficients respectively.Thirdly,to obtain a real de-noised signal,new combined information series is devised.By applying different combination of real part and imaginary part of de-noised complex signal,a real de-noised signal can be restored with higher peak signal-to-noise ratio(PSNR)and less distortion of original signals.Finally,On-site applications of extracting PD signals from noisy background by the optimal de-noising scheme based on CDW are illustrated.The on-site experimental results show that the optimal de-noising scheme is an effective way to suppress white noise in PD measurement.
文摘This paper introduces a new method to separate PD1 from other disturbing signals present on the high voltage genera-tors and motors. The method is based on combination of a pattern classifier, the Discrete Wavelet Transform (DWT), to de-noise PD and Time-Of-Arrival method to separate PD sources. Furthermore, it will be shown that it can recognize PD sources including rotating machine’s internal and external discharge pulses (e.g. on the bus bar).
基金Sponsored by the Liaoning Provincial Department of Education Scientific Research Funding Project(Youth)(Grant No.JDL2020020)the Changzhou City Applied Basic Research Program(Grant No.CJ2020007).
文摘Partial discharge(PD)is an important reason for the insulation failure of the switchgear.In the process of PD detection,PD signal is often annihilated in strong noise.In order to improve the accuracy of PD detection in power plant switchgear,a method based on continuous adaptive wavelet threshold switchgear PD signals denoising is proposed in this paper.By constructing a continuous adaptive threshold function and introducing adjustment parameters,the problems of over⁃processing of traditional hard threshold functions and incomplete denoising of soft threshold functions can be improved.The analysis results of simulated signals and measured signals show that the continuous adaptive wavelet threshold denoising method is significantly better than the traditional denoising method for the PD signal.The proposed method in this paper retains the characteristics of the original signal.Compared with the traditional denoising methods,after denoising the simulated signals,the signal⁃to⁃noise ratio(SNR)is increased by more than 30%,and the root⁃mean⁃square error(RMSE)is reduced by more than 30%.After denoising the real signal,the noise suppression ratio(NRR)is increased by more than 40%.The recognition accuracy rate of PD signal has also been improved to a certain extent,which proves that the method has a certain practicability.
基金Project supported by National Basic Research Program of China (973 Program) (2011CB 209400)State Key Laboratory of Control and Simulation of Power Systems and Generation Equipments (SKLD10M09)Program for ±1 100 kV UHVDC Technology
文摘Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the statistical function. Thus, we developed a test system for PD detection under DC voltage, which is characterized by strong anti-jamming capability, continuous high-speed real-time data acquisi- tion and effective, complete detection of DC PD signals. The DC PD mechanism, as well as the measuring principles, software system, and hardware design of the test equipment were introduced. Adopting typical electrode pairs, we tested the statistical spectrum of PD under DC voltage. The main difference in statistical spectrums between parallel plate electrodes and needle-plate electrodes was that the time interval between two consecutive discharges for needle-plate electrodes has obviously larger variation range than that for parallel plate electrodes, which could be the convincing proof for distinguishing the type of electrodes under DC PD. Practical results indicate that the proposed sys- tem can measure time domain signals of DC PD of oil-paper insulation effectively and promptly, and it can be used to determine and detect defects in DC power transmission equipment.
基金supported by National High-tech Research and Development Program of China(863 Program)(2009AA04Z416) National Science Foundation of China(51021005) Scientific Innovation of Colleges and Universities(Project v-200704)