According to the construction of current coal mine monitoring and control systems in China, the paper proposes three kinds of applicable schemes of integrating PLC and DCS systems with field bus technology to digitize...According to the construction of current coal mine monitoring and control systems in China, the paper proposes three kinds of applicable schemes of integrating PLC and DCS systems with field bus technology to digitize the system and to improve the flexibility and extent of the system. Essentially, the paper introduces the integration of FCS on I/O layers. Based on a real coal mine safety-monitoring and control system applied with a CAN field bus, the major technology of system relays and extensions is discussed. We believe that one of the most applicable methods is currently replacing the connection between function-stations and field-sensors with a CAN bus on I/0 layers for system integration.展开更多
Under the current situation, China' s rapid economic development, various new science, emerge in an endless stream of new technology, under the environment of coal mine industry, seize the opportunity, by virtue of i...Under the current situation, China' s rapid economic development, various new science, emerge in an endless stream of new technology, under the environment of coal mine industry, seize the opportunity, by virtue of its original advantages, coupled with technology introduction and innovation consciousness of the play, ushered in a new period of development, into the modern coal mining era. CAN bus technology is a new technology which has the typical data transmission in coal mining, the introduction of a certain degree of CAN bus technology, not only improve the efficiency of data transmission, at the same time, in terms of reliability and greatly enhance. In this paper, to a certain extent on the introduction of the CAN bus technology, and on this basis, based on the CAN bus in the coal mine field data transmission reliability research and analysis展开更多
The intellectual property (IP) core for inter-integrated circuit (IIC) bus controller is designed using finite state machine (FSM) based on field programmable gate array (FPGA). Not only the data from AT 24C02...The intellectual property (IP) core for inter-integrated circuit (IIC) bus controller is designed using finite state machine (FSM) based on field programmable gate array (FPGA). Not only the data from AT 24C02C can be read automatically after power on, but also the data from upper computer can be written into AT24C02C immediately under the control of the IIC bus controller. When it is applied to blast wave overpressure test system, the IIC bus controller can read and store working parameters automatically. In a laboratory environment, the IP core simulation is carried out and the result is accurate. In the explosion field test, by analyzing the obtained valid data, it can be concluded that the designed IP core has good reliability.展开更多
To investigate the differences and the development trends of the 400 kA aluminum reduction cell, four representative cells were deeply analyzed. By using numerical simulation methods in ANSYS software, the structure p...To investigate the differences and the development trends of the 400 kA aluminum reduction cell, four representative cells were deeply analyzed. By using numerical simulation methods in ANSYS software, the structure parameters were firstly compared, and then three-dimensional models of electric-magnetic-flow field were built and solved with finite element method(FEM). The comparison of the structures reveals that the cell bodies are similar while the current flow path and distribution ratio of bus bars are different. It appears that most of the current(70%-80%) in side A are used as the magnetic field compensation current and flow through two ends. The numerical simulation results indicate that the distributions of magnetic fields are different but all satisfy with the magnetohydrodynamics(MHD) stabilization, and the flow patterns are all two or multi vortexes with appropriate velocities. The comparison shows that all studied cells can satisfy with the physical field requirement, and the commercial applications also verify that the 400 kA cells have become the product of the mature and world's leading technology.展开更多
Currently,the mainstream vector network analyzer employs embedded computer module with a digital intermediate frequency(IF)board to form a high performance windows platform.Under this structure,the vector network anal...Currently,the mainstream vector network analyzer employs embedded computer module with a digital intermediate frequency(IF)board to form a high performance windows platform.Under this structure,the vector network analyzer needs a powerful encoding system to arbitrate the bus acquirement,which is usually realized by field-programmable gate array(FPGA)chip.The paper explores the shared bus design method of the digital signal processing(DSP)board in network analyzer.Firsty,it puts an emphasis on the system structure,and then the shared bus communication method is described in detail;Finally,the advantages of the shared bus communication mechanism are summanzed.展开更多
The unique of using industrial LAN based on field bus to construct the system of vibration monitoring and fault diagnosis is introduced. The LAN topology, client/server architecture, database and designing of applicat...The unique of using industrial LAN based on field bus to construct the system of vibration monitoring and fault diagnosis is introduced. The LAN topology, client/server architecture, database and designing of application software for vibration monitoring and fault diagnosis are involved. How to apply industrial LAN to the vibration monitoring and fault diagnosis of turbo generator is discussed, and a scheme of how to construct the industrial LAN for vibration monitoring and fault diagnosis of turbo generator is presented.展开更多
The resistance arrangements of the flexes connecting with the cathode bus bar in aluminum reduction cells were generalized as three modes. In each mode the universal method to select proper resistivity of the flexes w...The resistance arrangements of the flexes connecting with the cathode bus bar in aluminum reduction cells were generalized as three modes. In each mode the universal method to select proper resistivity of the flexes was induced respectively to insure that the current in local group of flexes was equal. Furthermore, a 350 kA aluminum reduction cell based electric field model was developed by finite element method to evaluate the effect of the method. Suggestions on selection of three modes were also put forward. The results show that the methods of resistance optimization can reduce the current variation about 180 A compared with that in original case.展开更多
A network structure of coalmine integrated automation system based on NetLinx was proposed. The features of three-layer-network structure were discussed in detail. The mechanism of time determination of the network wa...A network structure of coalmine integrated automation system based on NetLinx was proposed. The features of three-layer-network structure were discussed in detail. The mechanism of time determination of the network was analyzed. A design example of the integrated automation system for a real coalmine was presented.展开更多
文摘According to the construction of current coal mine monitoring and control systems in China, the paper proposes three kinds of applicable schemes of integrating PLC and DCS systems with field bus technology to digitize the system and to improve the flexibility and extent of the system. Essentially, the paper introduces the integration of FCS on I/O layers. Based on a real coal mine safety-monitoring and control system applied with a CAN field bus, the major technology of system relays and extensions is discussed. We believe that one of the most applicable methods is currently replacing the connection between function-stations and field-sensors with a CAN bus on I/0 layers for system integration.
文摘Under the current situation, China' s rapid economic development, various new science, emerge in an endless stream of new technology, under the environment of coal mine industry, seize the opportunity, by virtue of its original advantages, coupled with technology introduction and innovation consciousness of the play, ushered in a new period of development, into the modern coal mining era. CAN bus technology is a new technology which has the typical data transmission in coal mining, the introduction of a certain degree of CAN bus technology, not only improve the efficiency of data transmission, at the same time, in terms of reliability and greatly enhance. In this paper, to a certain extent on the introduction of the CAN bus technology, and on this basis, based on the CAN bus in the coal mine field data transmission reliability research and analysis
文摘The intellectual property (IP) core for inter-integrated circuit (IIC) bus controller is designed using finite state machine (FSM) based on field programmable gate array (FPGA). Not only the data from AT 24C02C can be read automatically after power on, but also the data from upper computer can be written into AT24C02C immediately under the control of the IIC bus controller. When it is applied to blast wave overpressure test system, the IIC bus controller can read and store working parameters automatically. In a laboratory environment, the IP core simulation is carried out and the result is accurate. In the explosion field test, by analyzing the obtained valid data, it can be concluded that the designed IP core has good reliability.
基金Projects(51104187,51274241,61321003) supported by the National Natural Science Foundation of ChinaProject(20100162120008) supported by Doctoral Fund of Ministry of Education of China
文摘To investigate the differences and the development trends of the 400 kA aluminum reduction cell, four representative cells were deeply analyzed. By using numerical simulation methods in ANSYS software, the structure parameters were firstly compared, and then three-dimensional models of electric-magnetic-flow field were built and solved with finite element method(FEM). The comparison of the structures reveals that the cell bodies are similar while the current flow path and distribution ratio of bus bars are different. It appears that most of the current(70%-80%) in side A are used as the magnetic field compensation current and flow through two ends. The numerical simulation results indicate that the distributions of magnetic fields are different but all satisfy with the magnetohydrodynamics(MHD) stabilization, and the flow patterns are all two or multi vortexes with appropriate velocities. The comparison shows that all studied cells can satisfy with the physical field requirement, and the commercial applications also verify that the 400 kA cells have become the product of the mature and world's leading technology.
文摘Currently,the mainstream vector network analyzer employs embedded computer module with a digital intermediate frequency(IF)board to form a high performance windows platform.Under this structure,the vector network analyzer needs a powerful encoding system to arbitrate the bus acquirement,which is usually realized by field-programmable gate array(FPGA)chip.The paper explores the shared bus design method of the digital signal processing(DSP)board in network analyzer.Firsty,it puts an emphasis on the system structure,and then the shared bus communication method is described in detail;Finally,the advantages of the shared bus communication mechanism are summanzed.
文摘The unique of using industrial LAN based on field bus to construct the system of vibration monitoring and fault diagnosis is introduced. The LAN topology, client/server architecture, database and designing of application software for vibration monitoring and fault diagnosis are involved. How to apply industrial LAN to the vibration monitoring and fault diagnosis of turbo generator is discussed, and a scheme of how to construct the industrial LAN for vibration monitoring and fault diagnosis of turbo generator is presented.
基金Project(60634020) supported by the National Natural Science Foundation of China
文摘The resistance arrangements of the flexes connecting with the cathode bus bar in aluminum reduction cells were generalized as three modes. In each mode the universal method to select proper resistivity of the flexes was induced respectively to insure that the current in local group of flexes was equal. Furthermore, a 350 kA aluminum reduction cell based electric field model was developed by finite element method to evaluate the effect of the method. Suggestions on selection of three modes were also put forward. The results show that the methods of resistance optimization can reduce the current variation about 180 A compared with that in original case.
文摘A network structure of coalmine integrated automation system based on NetLinx was proposed. The features of three-layer-network structure were discussed in detail. The mechanism of time determination of the network was analyzed. A design example of the integrated automation system for a real coalmine was presented.