The impact of Bapco 5 MW solar PV grid-connected project on Bahrain’s outlook for clean energy and energy-mix production was analyzed since solar electricity obtained from PV installation is considered as a non-linea...The impact of Bapco 5 MW solar PV grid-connected project on Bahrain’s outlook for clean energy and energy-mix production was analyzed since solar electricity obtained from PV installation is considered as a non-linear system. Several positive impacts were counted. These impacts were on business, economy, environment, research, green jobs creation and rooftop installation and other large-scale installation. This project had attracted public, investors, developers to invest in similar projects in the Kingdom of Bahrain;especially it is an environmentally friendly and smart technology. This innovative smart grid-connected 5 MW solar PV power plant is enough to electrify 500 houses @ 10 kW and had answered lots of frustrating questions such as the effect of dust on PV performance, need of man-made cleaning compared to naturally cleaned PV panels, reliability of the system, greenhouse gases reduction and pay-back period.展开更多
This paper assesses 4 years of operation of a 1.75 kW roof top solar PV system installed in a Sydney suburban house. The system consists of 10 PV panels, a DC/AC inverter, and a grid connected gross meter. Solar elect...This paper assesses 4 years of operation of a 1.75 kW roof top solar PV system installed in a Sydney suburban house. The system consists of 10 PV panels, a DC/AC inverter, and a grid connected gross meter. Solar electricity delivered to grid is verified with the results from a computer simulation package (PVSYST) by adopting the installed component specifications, operation conditions, and weather data of the site. The results show high consistency between the values of energy delivered to the grid measured by the energy company and the energy estimated by system simulation. New system performance indicator is developed and called the optimum performance compliance ratio (PCR). It is a measure of the compliance of the output of the designed PV system with the output which would be produced by the same system with a solar tracker. This indicator provides system designers, contractors and energy providers with the actual capacity of the system that they can offer the end-users.展开更多
Rural electrification remains a great challenge for Sub-Saharan Africa (SSA) as access to electricity is a prerequisite to accelerate its development. The present paper reviews the measures adopted to promote access t...Rural electrification remains a great challenge for Sub-Saharan Africa (SSA) as access to electricity is a prerequisite to accelerate its development. The present paper reviews the measures adopted to promote access to electricity in rural and remote areas of SSA. The main barriers to rural electrification in these developing countries are presented before showing technologies used for the aforementioned purpose. Then, adopted methods for enhancing the use of renewable energy in SSA are shown. Moreover, the policy adopted by decision makers and project planners are also highlighted. In addition, the optimal solutions proposed by researchers are given such as the cost-effective off-grid system type that might be a viable alternative to diesel power generation.展开更多
This paper presents the development and performance capability of a comprehensive Low voltage ride through (LVRT) control scheme that makes use of both the DC chopper and the current limiting based on the required rea...This paper presents the development and performance capability of a comprehensive Low voltage ride through (LVRT) control scheme that makes use of both the DC chopper and the current limiting based on the required reactive power during fault time. The study is conducted on an 8.5 MW single stage PV power plant (PVPP) connected to the Rwandan grid. In the event of fault disturbance, this control scheme helps to overcome the problems of excessive DC-link voltage by fast activation of the DC chopper operation. At the same instance, AC current is limited to the maximum rating of the inverter as a function of the injected reactive current. This helps overcome AC-over- current that may possibly lead to damage or disconnection of the inverter. The control scheme also ensures voltage support and power balance through the injection of reactive current as per grid code requirements. Selected simulations using MATLAB are carried out in the events of different kinds of fault caused voltage dips. Results demonstrate the effectiveness of the proposed LVRT control scheme.展开更多
Global energy demand is growing rapidly owing to industrial growth and urbanization.Alternative energy sources are driven by limited reserves and rapid depletion of conventional energy sources(e.g.,fossil fuels).Solar...Global energy demand is growing rapidly owing to industrial growth and urbanization.Alternative energy sources are driven by limited reserves and rapid depletion of conventional energy sources(e.g.,fossil fuels).Solar photovol-taic(PV),as a source of electricity,has grown in popularity over the last few dec-ades because of their clean,noise-free,low-maintenance,and abundant availability of solar energy.There are two types of maximum power point track-ing(MPPT)techniques:classical and evolutionary algorithm-based techniques.Precise and less complex perturb and observe(P&O)and incremental conduc-tance(INC)approaches are extensively employed among classical techniques.This study used afield-programmable gate array(FPGA)-based hardware arrange-ment for a grid-connected photovoltaic(PV)system.The PV panels,MPPT con-trollers,and battery management systems are all components of the proposed system.In the developed hardware prototype,various modes of operation of the grid-connected PV system were examined using P&O and incremental con-ductance MPPT approaches.展开更多
Domestic off-grid renewable energy systems have become common place in many areas of the world, as humanity seeks to keep abreast with global technological changes and advancements. This paper aims to present a cost-e...Domestic off-grid renewable energy systems have become common place in many areas of the world, as humanity seeks to keep abreast with global technological changes and advancements. This paper aims to present a cost-effective energy monitoring system which may be used to analyze and evaluate the operation of a domestic off-grid PV system. Parameters which are monitored include the output voltage and current from a 55 W polycrystalline PV panel. The output voltage and current from a power regulation circuit (which could be a DC-DC converter, solar charger or MPPT) is also monitored with this singular system which incorporates a data logging interface circuit, a data logger and a personal computer.展开更多
Because of rich solar resource and low land cost, a lot of large-scale ground-based grid-connected PV systems have been built in Northwest China. In this paper, some shading phenomena on a grid-connected PV system inN...Because of rich solar resource and low land cost, a lot of large-scale ground-based grid-connected PV systems have been built in Northwest China. In this paper, some shading phenomena on a grid-connected PV system inNorthwest Chinaare classified and analyzed. Through the I-V curve test of PV modules, it can be seen that dust influence system performance of the grid-connected PV system. And the experimental results have shown that shading could affect the electrical properties of PV modules. Meanwhile, same shading area on different shading positions could have different impacts on the identical PV module.展开更多
This paper focuses on the design of the inverter power stage connected with PV-grid which supports the contrived PV system. The increased number of grid connected photovoltaic (PV) inverters gave rise to problems conc...This paper focuses on the design of the inverter power stage connected with PV-grid which supports the contrived PV system. The increased number of grid connected photovoltaic (PV) inverters gave rise to problems concerning the stability and safety of the utility grid, as well as power quality issues. The proposed systems can overcome these issues and improve standard regulation methods for gird connected PV inverter. The maximum available voltage in the PV string is tracked by the power stage which has been planned and designed in such a way. The tracked voltage is boosted then. The important components to voltage source inverter (VSI) are boost inductor and input capacitor which are calculated. To get a clear sinusoidal output phase voltage of 230 V from a DC capacitance bus projected to deal with 400 V, the important inverter stage parameters have been planned and modeled in Mat lab. Each block stage of the converter is easily understandable by the Simlink of the dual stage DC-AC converter explanation. The control schemes which have been proposed would compromise with the inverter power stage which forms the neat grid system. The existing renewable energy sources in the laboratory are integrated by the proposed control.展开更多
In this paper power electronics used in PV power generation systems have been reviewed and modelled. PV systems need converters for maximum power point tracking, power conditioning, voltage step-up/down as necessary, ...In this paper power electronics used in PV power generation systems have been reviewed and modelled. PV systems need converters for maximum power point tracking, power conditioning, voltage step-up/down as necessary, and for storage charge-controlling. Inverters are needed for AC loads and for utility grid interfacing. The four basic DC-DC converters commonly used with PV systems have been reviewed and modelled. Different DC-AC inverter types and operational architectures have also been reviewed with the two-stage DC-AC inverter, with the point of common coupling (PCC) at the inverter input, suggested as the most cost-effective and efficient architecture for PV-based communal grids. This is because only one inverter is used for the entire system as opposed to an inverter for every module string, resulting in higher efficiencies, low cost, and low harmonic distortions when compared to systems with PCC at AC terminal. The aim of power conversion/inversion is to extract maximum power possible from the PV system and where necessary, to invert it at close to 100% as possible. Highlight: 1) DC-DC converters are necessary for power conditioning in PV systems;2) DC-AC inverters are necessary for AC loads and for utility grid interfacing;3) DC-AC inverters are also used to control the PV systems when grid connected;4) Best inverter configuration cost-effectively and efficiently allows easy system modifications.展开更多
Nowadays, the DC distribution system has been suggested, as a replacement for the AC power distribution system with electric propulsion. This idea signifies a fresh approach of issuing energy for low-voltage installat...Nowadays, the DC distribution system has been suggested, as a replacement for the AC power distribution system with electric propulsion. This idea signifies a fresh approach of issuing energy for low-voltage installations. It can be used for any electrical application up to 20 MW and works at a nominal voltage of 1000 V DC. The DC distribution system is just an extension of the multiple DC links that previously available in all propulsion and thruster drives, which typically comprise more than 80% of the electrical power consumption on electric propulsion vessels. A fault detection and islanding scheme for DC grid connected PV system is presented in this paper. Unlike traditional ac distribution systems, protection has been challenging for dc systems. The goals of this paper are to classify and detect the fault in the PV system as well as DC grid and to isolate the faulted section so that the system keeps operating without disabling the entire system. The results show the measured values of power at PV panel and DC grid side under different fault condition, which indicates the type of fault that occurs in the system.展开更多
One main concern of power quality is harmonics because the distorted waveforms of current and voltage have a huge effect on electrical equipment. Due to the continuous increase of grid connected photovoltaic (PV) and ...One main concern of power quality is harmonics because the distorted waveforms of current and voltage have a huge effect on electrical equipment. Due to the continuous increase of grid connected photovoltaic (PV) and nonlinear loads, as a result of the fast development and growth of power electronics application, power quality becomes more important since it introduces harmonics to the power system. This paper presents a power quality study to the isolated northwest grid of Saudi Arabia in presence of PV system and battery storage. Moreover, the study includes nonlinear loads for more analysis regarding harmonics penetration and the design procedure for passive filters to eliminate the harmonics.展开更多
The conventional approach to optimizing tilt angles for fixed solar panels aims to maximize energy generation over the entire year. However, in the context of a supply controlled electric grid, where solar energy avai...The conventional approach to optimizing tilt angles for fixed solar panels aims to maximize energy generation over the entire year. However, in the context of a supply controlled electric grid, where solar energy availability varies, this criterion may not be optimal. This study explores two alternative optimization criteria focused on maximizing baseload supply potential and minimizing required storage capacity to address seasonality in energy generation. The optimal tilt angles determined for these criteria differed significantly from the standard approach. This research highlights additional factors crucial for designing solar power systems beyond gross energy generation, essential for the global transition towards a fully renewable energy-based electric grid in the future.展开更多
文摘The impact of Bapco 5 MW solar PV grid-connected project on Bahrain’s outlook for clean energy and energy-mix production was analyzed since solar electricity obtained from PV installation is considered as a non-linear system. Several positive impacts were counted. These impacts were on business, economy, environment, research, green jobs creation and rooftop installation and other large-scale installation. This project had attracted public, investors, developers to invest in similar projects in the Kingdom of Bahrain;especially it is an environmentally friendly and smart technology. This innovative smart grid-connected 5 MW solar PV power plant is enough to electrify 500 houses @ 10 kW and had answered lots of frustrating questions such as the effect of dust on PV performance, need of man-made cleaning compared to naturally cleaned PV panels, reliability of the system, greenhouse gases reduction and pay-back period.
文摘This paper assesses 4 years of operation of a 1.75 kW roof top solar PV system installed in a Sydney suburban house. The system consists of 10 PV panels, a DC/AC inverter, and a grid connected gross meter. Solar electricity delivered to grid is verified with the results from a computer simulation package (PVSYST) by adopting the installed component specifications, operation conditions, and weather data of the site. The results show high consistency between the values of energy delivered to the grid measured by the energy company and the energy estimated by system simulation. New system performance indicator is developed and called the optimum performance compliance ratio (PCR). It is a measure of the compliance of the output of the designed PV system with the output which would be produced by the same system with a solar tracker. This indicator provides system designers, contractors and energy providers with the actual capacity of the system that they can offer the end-users.
文摘Rural electrification remains a great challenge for Sub-Saharan Africa (SSA) as access to electricity is a prerequisite to accelerate its development. The present paper reviews the measures adopted to promote access to electricity in rural and remote areas of SSA. The main barriers to rural electrification in these developing countries are presented before showing technologies used for the aforementioned purpose. Then, adopted methods for enhancing the use of renewable energy in SSA are shown. Moreover, the policy adopted by decision makers and project planners are also highlighted. In addition, the optimal solutions proposed by researchers are given such as the cost-effective off-grid system type that might be a viable alternative to diesel power generation.
文摘This paper presents the development and performance capability of a comprehensive Low voltage ride through (LVRT) control scheme that makes use of both the DC chopper and the current limiting based on the required reactive power during fault time. The study is conducted on an 8.5 MW single stage PV power plant (PVPP) connected to the Rwandan grid. In the event of fault disturbance, this control scheme helps to overcome the problems of excessive DC-link voltage by fast activation of the DC chopper operation. At the same instance, AC current is limited to the maximum rating of the inverter as a function of the injected reactive current. This helps overcome AC-over- current that may possibly lead to damage or disconnection of the inverter. The control scheme also ensures voltage support and power balance through the injection of reactive current as per grid code requirements. Selected simulations using MATLAB are carried out in the events of different kinds of fault caused voltage dips. Results demonstrate the effectiveness of the proposed LVRT control scheme.
文摘Global energy demand is growing rapidly owing to industrial growth and urbanization.Alternative energy sources are driven by limited reserves and rapid depletion of conventional energy sources(e.g.,fossil fuels).Solar photovol-taic(PV),as a source of electricity,has grown in popularity over the last few dec-ades because of their clean,noise-free,low-maintenance,and abundant availability of solar energy.There are two types of maximum power point track-ing(MPPT)techniques:classical and evolutionary algorithm-based techniques.Precise and less complex perturb and observe(P&O)and incremental conduc-tance(INC)approaches are extensively employed among classical techniques.This study used afield-programmable gate array(FPGA)-based hardware arrange-ment for a grid-connected photovoltaic(PV)system.The PV panels,MPPT con-trollers,and battery management systems are all components of the proposed system.In the developed hardware prototype,various modes of operation of the grid-connected PV system were examined using P&O and incremental con-ductance MPPT approaches.
文摘Domestic off-grid renewable energy systems have become common place in many areas of the world, as humanity seeks to keep abreast with global technological changes and advancements. This paper aims to present a cost-effective energy monitoring system which may be used to analyze and evaluate the operation of a domestic off-grid PV system. Parameters which are monitored include the output voltage and current from a 55 W polycrystalline PV panel. The output voltage and current from a power regulation circuit (which could be a DC-DC converter, solar charger or MPPT) is also monitored with this singular system which incorporates a data logging interface circuit, a data logger and a personal computer.
文摘Because of rich solar resource and low land cost, a lot of large-scale ground-based grid-connected PV systems have been built in Northwest China. In this paper, some shading phenomena on a grid-connected PV system inNorthwest Chinaare classified and analyzed. Through the I-V curve test of PV modules, it can be seen that dust influence system performance of the grid-connected PV system. And the experimental results have shown that shading could affect the electrical properties of PV modules. Meanwhile, same shading area on different shading positions could have different impacts on the identical PV module.
文摘This paper focuses on the design of the inverter power stage connected with PV-grid which supports the contrived PV system. The increased number of grid connected photovoltaic (PV) inverters gave rise to problems concerning the stability and safety of the utility grid, as well as power quality issues. The proposed systems can overcome these issues and improve standard regulation methods for gird connected PV inverter. The maximum available voltage in the PV string is tracked by the power stage which has been planned and designed in such a way. The tracked voltage is boosted then. The important components to voltage source inverter (VSI) are boost inductor and input capacitor which are calculated. To get a clear sinusoidal output phase voltage of 230 V from a DC capacitance bus projected to deal with 400 V, the important inverter stage parameters have been planned and modeled in Mat lab. Each block stage of the converter is easily understandable by the Simlink of the dual stage DC-AC converter explanation. The control schemes which have been proposed would compromise with the inverter power stage which forms the neat grid system. The existing renewable energy sources in the laboratory are integrated by the proposed control.
文摘In this paper power electronics used in PV power generation systems have been reviewed and modelled. PV systems need converters for maximum power point tracking, power conditioning, voltage step-up/down as necessary, and for storage charge-controlling. Inverters are needed for AC loads and for utility grid interfacing. The four basic DC-DC converters commonly used with PV systems have been reviewed and modelled. Different DC-AC inverter types and operational architectures have also been reviewed with the two-stage DC-AC inverter, with the point of common coupling (PCC) at the inverter input, suggested as the most cost-effective and efficient architecture for PV-based communal grids. This is because only one inverter is used for the entire system as opposed to an inverter for every module string, resulting in higher efficiencies, low cost, and low harmonic distortions when compared to systems with PCC at AC terminal. The aim of power conversion/inversion is to extract maximum power possible from the PV system and where necessary, to invert it at close to 100% as possible. Highlight: 1) DC-DC converters are necessary for power conditioning in PV systems;2) DC-AC inverters are necessary for AC loads and for utility grid interfacing;3) DC-AC inverters are also used to control the PV systems when grid connected;4) Best inverter configuration cost-effectively and efficiently allows easy system modifications.
文摘Nowadays, the DC distribution system has been suggested, as a replacement for the AC power distribution system with electric propulsion. This idea signifies a fresh approach of issuing energy for low-voltage installations. It can be used for any electrical application up to 20 MW and works at a nominal voltage of 1000 V DC. The DC distribution system is just an extension of the multiple DC links that previously available in all propulsion and thruster drives, which typically comprise more than 80% of the electrical power consumption on electric propulsion vessels. A fault detection and islanding scheme for DC grid connected PV system is presented in this paper. Unlike traditional ac distribution systems, protection has been challenging for dc systems. The goals of this paper are to classify and detect the fault in the PV system as well as DC grid and to isolate the faulted section so that the system keeps operating without disabling the entire system. The results show the measured values of power at PV panel and DC grid side under different fault condition, which indicates the type of fault that occurs in the system.
文摘One main concern of power quality is harmonics because the distorted waveforms of current and voltage have a huge effect on electrical equipment. Due to the continuous increase of grid connected photovoltaic (PV) and nonlinear loads, as a result of the fast development and growth of power electronics application, power quality becomes more important since it introduces harmonics to the power system. This paper presents a power quality study to the isolated northwest grid of Saudi Arabia in presence of PV system and battery storage. Moreover, the study includes nonlinear loads for more analysis regarding harmonics penetration and the design procedure for passive filters to eliminate the harmonics.
文摘The conventional approach to optimizing tilt angles for fixed solar panels aims to maximize energy generation over the entire year. However, in the context of a supply controlled electric grid, where solar energy availability varies, this criterion may not be optimal. This study explores two alternative optimization criteria focused on maximizing baseload supply potential and minimizing required storage capacity to address seasonality in energy generation. The optimal tilt angles determined for these criteria differed significantly from the standard approach. This research highlights additional factors crucial for designing solar power systems beyond gross energy generation, essential for the global transition towards a fully renewable energy-based electric grid in the future.