期刊文献+
共找到426篇文章
< 1 2 22 >
每页显示 20 50 100
Left bundle branch pacing set to outshine biventricular pacing for cardiac resynchronization therapy?
1
作者 Akash Batta Juniali Hatwal 《World Journal of Cardiology》 2024年第4期186-190,共5页
The deleterious effects of long-term right ventricular pacing necessitated the search for alternative pacing sites which could prevent or alleviate pacinginduced cardiomyopathy.Until recently,biventricular pacing(BiVP... The deleterious effects of long-term right ventricular pacing necessitated the search for alternative pacing sites which could prevent or alleviate pacinginduced cardiomyopathy.Until recently,biventricular pacing(BiVP)was the only modality which could mitigate or prevent pacing induced dysfunction.Further,BiVP could resynchronize the baseline electromechanical dssynchrony in heart failure and improve outcomes.However,the high non-response rate of around 20%-30%remains a major limitation.This non-response has been largely attributable to the direct non-physiological stimulation of the left ventricular myocardium bypassing the conduction system.To overcome this limitation,the concept of conduction system pacing(CSP)came up.Despite initial success of the first CSP via His bundle pacing(HBP),certain drawbacks including lead instability and dislodgements,steep learning curve and rapid battery depletion on many occasions prevented its widespread use for cardiac resynchronization therapy(CRT).Subsequently,CSP via left bundle branch-area pacing(LBBP)was developed in 2018,which over the last few years has shown efficacy comparable to BiVP-CRT in small observational studies.Further,its safety has also been well established and is largely free of the pitfalls of the HBP-CRT.In the recent metanalysis by Yasmin et al,comprising of 6 studies with 389 participants,LBBPCRT was superior to BiVP-CRT in terms of QRS duration,left ventricular ejection fraction,cardiac chamber dimensions,lead thresholds,and functional status amongst heart failure patients with left bundle branch block.However,there are important limitations of the study including the small overall numbers,inclusion of only a single small randomized controlled trial(RCT)and a small follow-up duration.Further,the entire study population analyzed was from China which makes generalizability a concern.Despite the concerns,the meta-analysis adds to the growing body of evidence demonstrating the efficacy of LBBP-CRT.At this stage,one must acknowledge that the fact that still our opinions on this technique are largely based on observational data and there is a dire need for larger RCTs to ascertain the position of LBBPCRT in management of heart failure patients with left bundle branch block. 展开更多
关键词 Biventricular pacing Cardiac resynchronization therapy Conduction system pacing Left bundle branch-area pacing Left bundle branch block Electromechanical dssynchrony
下载PDF
Left bundle branch pacing vs biventricular pacing in heart failure patients with left bundle branch block:A systematic review and meta-analysis 被引量:1
2
作者 Farah Yasmin Abdul Moeed +7 位作者 Rohan Kumar Ochani Hamna Raheel Malik Ali Ehtsham Awan Ayesha Liaquat Arisha Saleem Muhammad Aamir Nael Hawwa Salim Surani 《World Journal of Cardiology》 2024年第1期40-48,共9页
BACKGROUND Left bundle branch pacing(LBBP)is a novel pacing modality of cardiac resynchronization therapy(CRT)that achieves more physiologic native ventricular activation than biventricular pacing(BiVP).AIM To explore... BACKGROUND Left bundle branch pacing(LBBP)is a novel pacing modality of cardiac resynchronization therapy(CRT)that achieves more physiologic native ventricular activation than biventricular pacing(BiVP).AIM To explore the validity of electromechanical resynchronization,clinical and echocardiographic response of LBBP-CRT.METHODS Systematic review and Meta-analysis were conducted in accordance with the standard guidelines as mentioned in detail in the methodology section.RESULTS In our analysis,the success rate of LBBP-CRT was determined to be 91.1%.LBBP CRT significantly shortened QRS duration,with significant improvement in echocardiographic parameters,including left ventricular ejection fraction,left ventricular end-diastolic diameter and left ventricular end-systolic diameter in comparison with BiVP-CRT.CONCLUSION A significant reduction in New York Heart Association class and B-type natriuretic peptide levels was also observed in the LBBP-CRT group vs BiVP-CRT group.Lastly,the LBBP-CRT cohort had a reduced pacing threshold at follow-up as compared to BiVP-CRT. 展开更多
关键词 Left bundle branch pacing Biventricular pacing QRS duration Left ventricular ejection fraction Heart failure
下载PDF
The Impact of Cardiac Pacing Site on Patient's Cardiac Function and Psychological State
3
作者 Haiyang Xiao Liang Sun 《Expert Review of Chinese Medical》 2024年第2期18-22,共5页
With the widespread application of artificial permanent pacemakers in clinical practice,there have been new changes in the indications for pacemaker implantation.The current clinical indications include high atriovent... With the widespread application of artificial permanent pacemakers in clinical practice,there have been new changes in the indications for pacemaker implantation.The current clinical indications include high atrioventricular block,sick sinus syndrome,cardiac resynchronization therapy for heart failure,and implantation of cardioverter defibrillators for ventricular arrhythmias.The implantation of a pacemaker can improve the quality of life and prognosis of patients with arrhythmia.In the past,permanent pacemaker implantation was performed in clinical practice,and the right ventricular pacing electrode was often fixed at the apex of the right ventricle,which belongs to non physiological pacing.Through long-term clinical follow-up,it was found that apex pacing can easily cause abnormal depolarization of the left ventricle,asynchronous contraction of the myocardium,and ultimately lead to myocardial fibrosis,which has adverse effects on the patient's cardiac function and psychological state.In recent years,Scholars have found that pacing in the right ventricular outflow tract septum is closer to the atrioventricular node and closer to the His bundle Purkinje fibers.The pacing impulse almost simultaneously expands towards both ventricles,closer to the physiological pacing state,thereby reducing the occurrence of cardiovascular events in patients.This article explores the impact of pacing in different parts of the heart on the cardiac function and psychological state of patients based on clinical data from the past three years. 展开更多
关键词 pacing site cardiac function psychological state
下载PDF
Inadvertent Lead Malposition in the Left Ventricle during Permanent Ventricular Pacing about One Case
4
作者 Khadidiatou Dia Waly Niang Mboup +5 位作者 Serigne Cheikh Tidiane Ndao Mame Madjiguene Ka Rabab Yassine Djibril Marie Ba Demba Ware Balde Mouhamed Cherif Mboup 《World Journal of Cardiovascular Diseases》 2023年第11期756-763,共8页
Inadvertent Lead Malposition in Left Ventricle is a rare and underdiagnosed incident, which may occur during implantation of cardiac electronic devices and may remain asymptomatic. We reported the case of a 71-year-ol... Inadvertent Lead Malposition in Left Ventricle is a rare and underdiagnosed incident, which may occur during implantation of cardiac electronic devices and may remain asymptomatic. We reported the case of a 71-year-old man who was implanted with a ventricular single-chamber pacemaker for a slow atrial fibrillation with syncope and whose routine transthoracic echocardiography 23 months after implantation displayed a malposition of the pacemaker lead into the Left Ventricle through a patent foramen oval. The patient was asymptomatic. The electrocardiogram showed right bundle branch block QRS-paced morphology with a positive QRS pattern in V1, a median paced QRS axis on the frontal plane at -120°, a Precordial transition on V5. At the lateral Chest X-ray the lead curved backwards to the spine. Given the age of this old patient who already received oral anticoagulant for Atrial Fibrillation and the Lead malposition discovered 23 months after pacemaker’s implantation, we decided to maintain the lead in LV and continue anticoagulation. 展开更多
关键词 Lead Malposition Left Ventricle Lead Right Bundle Branch Block Ventricu-lar pacing Transthoracic Echocardiography
下载PDF
Left bundle branch pacing in a ventricular pacing dependent patient with heart failure:A case report
5
作者 Bing-Xue Song Xia-Xia Wang +1 位作者 Yi An Ying-Ying Zhang 《World Journal of Clinical Cases》 SCIE 2022年第20期7090-7096,共7页
BACKGROUND Left bundle branch pacing(LBBP)is a physiological pacing method that has emerged in recent years.It is an ideal choice for patients with complete left bundle branch block who are in need of cardiac resynchr... BACKGROUND Left bundle branch pacing(LBBP)is a physiological pacing method that has emerged in recent years.It is an ideal choice for patients with complete left bundle branch block who are in need of cardiac resynchronization therapy(CRT).Moreover,LBBP is superior in maintaining physiological ventricular activation and can effectively improve heart function and quality of life in patients with pacemaker-induced cardiomyopathy.However,LBBP in pacing-dependent patients who already have cardiac dysfunction has not been well assessed.CASE SUMMARY A 69-year-old male patient presented with symptoms of chest tightness,palpitation and systolic heart failure with New York Heart Association class III for 1 mo.The 12-lead electrocardiogram showed atrial fibrillation with third-degree atrioventricular block and ventricular premature beat.Holter revealed a right bundle branch block,atrial fibrillation with third-degree atrioventricular block,frequent multifocal ventricular premature beats,Ron-T and ventricular tachycardia.The echocardiogram documented an enlarged left atrium and left ventricle and a low left ventricular ejection fraction.Coronary angiography indicated a stenosis of 30%in the middle left anterior descending artery.Apparently,a CRT-D pacemaker was the best choice for this patient according to previous findings.However,the patient was worried about the financial burden.A single-chamber pacemaker with LBBP was selected,with the plan to take amiodarone and upgrade with dual-chamber implantable cardioverter-defibrillator or CRT-D at an appropriate time.During the follow-up at 3 mo after LBBP,the patient showed an improvement in cardiac function with slight improvement in echocardiography parameters,and the New York Heart Association functional class was maintained at I.Moreover,the patient no longer suffered from chest tightness and palpitation.Holter showed decreased ventricular arrhythmia of less than 5%.CONCLUSION LBBP might be used in patients with heart failure and a high-degree atrioventricular block as an alternative to conventional CRT. 展开更多
关键词 Left bundle branch area pacing Physiological pacing Heart failure Cardiac resynchronization therapy pacing-dependent Case report
下载PDF
Right ventricular septal pacing: Safety and efficacy in a long term follow up 被引量:5
6
作者 Eraldo Occhetta Gianluca Quirino +10 位作者 Lara Baduena Rosaria Nappo Chiara Cavallino Emanuela Facchini Paolo Pistelli Andrea Magnani Miriam Bortnik Gabriella Francalacci Gabriele Dell’Era Laura Plebani Paolo Marino 《World Journal of Cardiology》 CAS 2015年第8期490-498,共9页
AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 ... AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 patients(74 ± 8 years; 169 men, 75 women) implanted with a single(132 pts) or dual chamber(112 pts) pacemaker(PM) with ventricular screw-in lead placed at the right ventricular high septal parahisian site(SEPTAL pacing);(2) 22 patients with permanent pacemaker and low percentage of pacing(< 20%)(NO pacing);(3) 33 patients with high percentage(> 80%) right ventricular apical pacing(RVA). All patients had a narrow spontaneous QRS(101 ± 14 ms). We evaluated New York Heart Association(NYHA) class, quality of life(Qo L), 6 min walking test(6MWT) and left ventricular function(end-diastolic volume, LV-EDV; end-systolic volume, LVESV; ejection fraction, LV-EF) with 2D-echocardiography. RESULTS: Pacing parameters were stable duringfollow up(21 mo/patient). In SEPTAL pacing group we observed an improvement in NYHA class, Qo L score and 6MWT. While LV-EDV didn't significantly increase(104 ± 40 m L vs 100 ± 37 m L; P = 0.35), LV-ESV slightly increased(55 ± 31 m L vs 49 ± 27 m L; P = 0.05) and LV-EF slightly decreased(49% ± 11% vs 53% ± 11%; P = 0.001) but never falling < 45%. In the RVA pacing control group we observed a worsening of NYHA class and an important reduction of LV-EF(from 56% ± 6% to 43% ± 9%, P < 0.0001).CONCLUSION: Right ventricular permanent high septal pacing is safe and effective in a long term follow up evaluation; it could be a good alternative to the conventional RVA pacing in order to avoid its deleterious effects. 展开更多
关键词 Right VENTRICULAR SEPTAL pacing Parahisian pacing RESYNCHRONIZATION therapy Left VENTRICULAR CARDIAC function PERMANENT CARDIAC pacing
下载PDF
Future easy and physiological cardiac pacing 被引量:5
7
作者 Eraldo Occhetta Miriam Bortnik Paolo Marino 《World Journal of Cardiology》 CAS 2011年第1期32-39,共8页
The right atrial appendage (RAA) and right ventricular apex (RVA) have been widely considered as conventional sites for typical dual-chamber atrio-ventricular cardiac (DDD) pacing. Unfortunately conventional RAA pacin... The right atrial appendage (RAA) and right ventricular apex (RVA) have been widely considered as conventional sites for typical dual-chamber atrio-ventricular cardiac (DDD) pacing. Unfortunately conventional RAA pacing seems not to be able to prevent atrial fibrillation in DDD pacing for tachycardia-bradycardia syndrome, and the presence of a left bundle branch type of activation induced by RVA pacing can have negative effects. A new technology with active screw-in leads permits a more physiological atrial and right ventricular pacing. In this review, we highlight the positive effects of pacing of these new and easily selected sites. The septal atrial lead permits a shorter and more homogeneous atrial activation, allowing better prevention of paroxysmal atrial fibrillation. The para-Hisian pacing can be achieved in a simpler and more reliable way with respect to biventricular pacing and direct Hisian pacing. We await larger trials to consider this "easy and physiological pacing" as a first approach in patients who need a high frequency of pacing. 展开更多
关键词 CARDIAC pacing ATRIAL SEPTUM Parahisian pacing
下载PDF
The importance of avoiding unnecessary right ventricular pacing in clinical practice 被引量:3
8
作者 Finn Akerstrm Miguel A Arias +3 位作者 Marta Pachón Jesús Jiménez-López Alberto Puchol Justo Juliá-Calvo 《World Journal of Cardiology》 CAS 2013年第11期410-419,共10页
Symptomatic bradycardia is effectively treated with the implantation of a cardiac pacemaker. Although a highly successful therapy, during recent years there has been a focus on the negative effects associated with lon... Symptomatic bradycardia is effectively treated with the implantation of a cardiac pacemaker. Although a highly successful therapy, during recent years there has been a focus on the negative effects associated with longterm pacing of the apex of the right ventricle(RV). It has been shown in both experimental and clinical studies that RV pacing leads to ventricular dyssynchrony, similar to that of left bundle branch block, with subsequent detrimental effects on cardiac structure and function, and in some cases adverse clinical outcomes such as atrial fibrillation, heart failure and death. There is substantial evidence that patients with reduced left ventricular function(LVEF) are at particular high risk of suffering the detrimental clinical effects of long-term RV pacing. The evidence is, however, incomplete, coming largely from subanalyses of pacemaker and implantable cardiac defibrillator studies. In this group of patients with reduced LVEF and an expected high amount of RV pacing, biventricular pacing(cardiac resynchronization therapy) devices can prevent the negative effects of RV pacing and reduce ventricular dyssynchrony. Therefore, cardiac resynchronization therapy has emerged as an attractive option with promising results and more clinical studies are underway. Furthermore, specific pacemaker algorithms, which minimize RV pacing, can also reduce the negative effects of RV stimulation on cardiac function and may prevent clinical deterioration. 展开更多
关键词 CARDIAC pacing Right VENTRICULAR pacing Heart failure Managed VENTRICULAR pacing CARDIAC RESYNCHRONIZATION therapy IMPLANTABLE cardioverterdefibrillator
下载PDF
Right Ventricular Outflow Tract Septal Pacing versus Apical Pacing: A Prospective, Randomized, Single-blind 5-Years Follow-up Study of Ventricular Lead Performance and Safety 被引量:4
9
作者 梁远红 刘烈 +4 位作者 陈东骊 林纯莹 费洪文 陈泗林 吴书林 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2015年第6期858-861,共4页
Summary: Lead placement for ventricular pacing variably impacts the physiological benefit of the pa- tient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal p... Summary: Lead placement for ventricular pacing variably impacts the physiological benefit of the pa- tient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal pacing in patients with bradyarrhythmia in South China over 60-month follow-up. Totally, 192 patients (108 males, and 84 females, 63-4-21 years old) with bradyarrhythmia were randomly divided into two groups. The right ventricular outflow tract septum (RVOTs) group had lead placement near the sep- tum (n=97), while the right ventricular apex (RVA) group had a traditional apical placement (n=95). RV septal lead positioning was achieved with a specialized stylet and confirmed using fluoroscopic projec- tion. All patients were followed up for 60 months. Follow-up assessment included stimulation threshold, R-wave sensing, lead impedance and lead complications. The time of electrode implantation in both the ROVTs and RVA groups were significantly different (4.29±0.61 vs. 2.16±0.22 min; P=0.009). No dif- ferences were identified in threshold, impedance or R-wave sensing between the two groups at 1 st, 12th, 36th and 60th month during the follow-up period. No occurrence of electrode displacement, increased pacing threshold or inadequate sensing was found. The long-term active fixation ventricular electrode performance in RVOTs group was similar to that in RVA group. RVOTs pacing near the septum using active fixation electrodes may provide stability during long-term follow-up period. 展开更多
关键词 right ventricular outflow tract setptum septal pacing FOLLOW-UP lead performance
下载PDF
Effects of febuxostat on atrial remodeling in a rabbit model of atrial fibrillation induced by rapid atrial pacing 被引量:2
10
作者 Yong-Yan FAN Feng XU +5 位作者 Chao ZHU Wen-Kun CHENG Jian LI Zhao-Liang SHAN Yang LI Yu-Tang WANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2019年第7期540-551,共12页
Background Febuxostat,a novel nonpurine selective inhibitor of xanthine oxidase(XO),may be used in the prevention and management of atrial fibrillation(AF).The purpose of this study was to evaluate the effects of febu... Background Febuxostat,a novel nonpurine selective inhibitor of xanthine oxidase(XO),may be used in the prevention and management of atrial fibrillation(AF).The purpose of this study was to evaluate the effects of febuxostat on atrial remodeling in a rabbit model of AF induced by rapid atrial pacing(RAP)and the mechanisms by which it acts.Methods Twenty-four rabbits were randomly divided into four groups:sham-operated group(Group S),RAP group(Group P),RAP with 5 mg/kg per day febuxostat group(Group LFP),and RAP with 10 mg/kg per day febuxostat group(Group HFP).All rabbits except those in Group S were subjected to RAP at 600 beats/min for four weeks.The effects of febuxostat on atrial electrical and structural remodeling,markers of inflammation and oxidative stress,and signaling pathways involved in the left atrium were examined.Results Shortened atrial effective refractory period(AERP),increased AF inducibility,decreased mRNA levels of Cav1.2 and Kv4.3,and left atrial enlargement and dysfunction were observed in Group P,and these changes were suppressed in the groups treated with febuxostat.Prominent atrial fibrosis was observed in Group P,as were increased levels of TGF-β1,Collagen I,andα-SMA and decreased levels of Smad7 and eNOS.Treatment with febuxostat attenuated these differences.Changes in inflammatory and oxidative stress markers induced by RAP were consistent with the protective effects of febuxostat.Conclusions This study is the first to find that febuxostat can inhibit atrial electrical and structural remodeling of AF by suppressing XO and inhibiting the TGF-β1/Smad signaling pathway. 展开更多
关键词 ATRIAL FIBRILLATION ATRIAL remodeling FEBUXOSTAT Rapid ATRIAL pacing XANTHINE OXIDASE
下载PDF
In vivo mechanical study of helical cardiac pacing electrode interacting with canine myocardium 被引量:1
11
作者 Xiangming Zhang Nianke Ma +2 位作者 Hualin Fan Guodong Niu Wei Yang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2007年第3期275-280,共6页
Cardiac pacing is a medical device to help human to overcome arrhythmia and to recover the regular beats of heart. A helical configuration of electrode tip is a new type of cardiac pacing lead distal tip. The helical ... Cardiac pacing is a medical device to help human to overcome arrhythmia and to recover the regular beats of heart. A helical configuration of electrode tip is a new type of cardiac pacing lead distal tip. The helical electrode attaches itself to the desired site of heart by screwing its helical tip into the myocardium. In vivo experiments on anesthetized dogs were carried out to measure the acute interactions between helical electrode and myocardium during screw-in and pull-out processes. These data would be helpful for electrode tip design and electrode/myocardium adherence safety evaluation. They also provide reliability data for clinical site choice of human heart to implant and to fix the pacing lead. A special design of the helical tip using strain gauges is instrumented for the measurement of the screw-in and pull-out forces. We obtained the data of screw-in torques and pull-out forces for five different types of helical electrodes at nine designed sites on ten canine hearts. The results indicate that the screw-in torques increased steplike while the torque-time curves presente saw-tooth fashion. The maximum torque has a range of 0.3-1.9 Nmm. Obvious differences are observed for different types of helical tips and for different test sites. Large pull-out forces are frequently obtained at epicardium of left ventricle and right ventricle lateral wall, and the forces obtained at right ventricle apex and outflow tract of right ventricle are normally small. The differences in pull-out forces are dictated by the geometrical configuration of helix and regional structures of heart muscle. 展开更多
关键词 Cardiac pacing Helical electrode Acute INTERACTIONS MYOCARDIUM
下载PDF
Biventricular pacing for treating heart failure in children: A case report and review of the literature 被引量:1
12
作者 Shan Yu Qiang Wu +4 位作者 Bao-Lin Chen Ya-Ping An Jie Bu Song Zhou Yong-Mei Wang 《World Journal of Clinical Cases》 SCIE 2019年第3期396-404,共9页
BACKGROUND Cardiac resynchronization therapy(CRT) can be used as an escalated therapy to improve heart function in patients with cardiac dysfunction due to long-term right ventricular pacing. However, guidelines are o... BACKGROUND Cardiac resynchronization therapy(CRT) can be used as an escalated therapy to improve heart function in patients with cardiac dysfunction due to long-term right ventricular pacing. However, guidelines are only targeted at adults. CRT is rarely used in children.CASE SUMMARY This case aimed to implement biventricular pacing in one child with heart failure who had a left ventricular ejection fraction < 35% at 4 years after implantation of an atrioventricular sequential pacemaker due to atrioventricular block.Postoperatively, echocardiography showed atrial sensing ventricular pacing and QRS wave duration of 120-130 ms, and cardiac function significantly improved after upgrading pacemaker.CONCLUSION Patients whose cardiac function is deteriorated to a level to upgrade to CRT should be upgraded to reverse myocardial remodeling as soon as possible. 展开更多
关键词 Artificial CARDIAC pacing Atrioventricular block CARDIAC RESYNCHRONIZATION therapy CHILD Heart failure Case report
下载PDF
Hemodynamic improvement by right ventricular septal pacing in elderly patients with chronic atrial fibrillation and slow ventricular response
13
作者 Wei HUA Shidong GUO Shu ZHANG Fangzheng WANG Lida ZHI Hongxia NIU Xin CHEN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2005年第2期103-106,共4页
Background and objectives Right ventricular apical (RVA) pacing has been reported impairing left ventricular (LV)performance. Alternative pacing sites in right ventricle (RV) has been explored to obtain better cardiac... Background and objectives Right ventricular apical (RVA) pacing has been reported impairing left ventricular (LV)performance. Alternative pacing sites in right ventricle (RV) has been explored to obtain better cardiac function. Our study was designed to compare the hemodynamic effects of right ventricular septal (RVS) pacing with RVA pacing. Methods Ten elderly patients with chronic atrial fibrillation (AF) and long RR interval or slow ventricular response (VR) received VVI pacing. The hemodynamic difference between RVS and RVA pacing were examined by transthoracic echocardiography (TTE). Results Pacing leads were implanted successfully at the RVA and then RVS in all patients without complication. The left ventricular (LV) parameters,measured during RVA pacing including left ventricular ejection fraction (LVEF), FS, stroke volume (SV) and peak E wave velocity (EV) were decreased significantly compared to baseline data, while during RVS pacing, they were significantly better than those during RVA pacing. However, after 3-6 weeks there was no statistical significant difference between pre- and post- RVS pacing.Conclusions The LV hemodynamic parameters during RVA pacing were significantly worse than baseline data. The short term LV hemodynamic parameters of RVS pacing were significantly better than those of RVA pacing; RVS pacing could improve the hemodynamic effect through maintaining normal ventricular activation sequence and biventricular contraction synchrony in patients with chronic AF and slow ventricular response. 展开更多
关键词 cardiac pacing right VENTRICULAR septal hemodynamics ECHOCARDIOGRAPHY
下载PDF
Minimizing right ventricular pacing in sinus node disease: Sometimes the cure is worse than the disease
14
作者 Elia De Maria Alina Olaru Stefano Cappelli 《World Journal of Clinical Cases》 SCIE 2015年第3期206-209,共4页
Traditional right ventricular(RV) apical pacing has been associated with heart failure, atrial fibrillation and increased mortality. To avoid the negative consequences of RV apical pacing different strategies have bee... Traditional right ventricular(RV) apical pacing has been associated with heart failure, atrial fibrillation and increased mortality. To avoid the negative consequences of RV apical pacing different strategies have been developed, among these a series of pacing algorithms designed to minimize RV pacing. These functions are particularly useful when there is not the need for continuous RV pacing: intermittent atrioventricular blocks and, mainly, sinus node disease. However, in order to avoid RV pacing, the operationalfeatures of these algorithms may lead to adverse(often under-appreciated) consequences in some patients. We describe a case of a patient with sinus node disease, in whom right atrial only pacing involved long atrio-ventricular delay to allow intrinsic ventricular conduction, which led to symptomatic hypotension that could be overcome only by "forcing" also right ventricular apical pacing. We subsequently discuss this case in the context of current available literature. 展开更多
关键词 RIGHT ventricular APICAL pacing PACEMAKER algorithms DYSSYNCHRONY PACEMAKER syndrome RIGHT atrial pacing
下载PDF
Transoesophageal emergency ventricular pacing with esophageal balloon electrode catheter
15
作者 Fangsheng Zheng Rongqiang Yan Hairong Zhao Luxia Mao Department of Cardiology, Affiliated Hospital of Qingdao University Medical College, Qingdao Shandong 266003, China 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2008年第3期142-145,共4页
Objective To evaluate the safety and possibility of transesophageal emergency ventricular pacing with esophageal balloon electrode catheter.Methods Sixty four patients with critical bradyarrhythmias were divided rando... Objective To evaluate the safety and possibility of transesophageal emergency ventricular pacing with esophageal balloon electrode catheter.Methods Sixty four patients with critical bradyarrhythmias were divided randomly to receive either transesophageal ventricular pacing with esophageal balloon electrode catheter (balloon catheter group,n=32),or transesophageal ventricular pacing with normal esophageal electrode catheter (normal catheter group,n=32).Pulse width (ms),current output (mA),and the success rate were compared between the 2 groups.Results Success rate in the balloon catheter group was 87.5%,which was significantly higher than that in the normal catheter group (18.7%,x^2=27.7,P【0.01).The success rate of transesophageal ventricular pacing with esophageal balloon electrode catheter was 87.5%.The average current output (mA) was significantly lower in the balloon catheter group than that in the normal catheter group (24.5±2.5 mA vs 53±3.4mA,P【0.05).Conclusions Esophageal balloon electrode catheter pacing could become an available technique for transesophageal emergency ventricular pacing. 展开更多
关键词 VENTRICULAR pacing BALLOON ELECTRODE CATHETER emergency.
下载PDF
His Bundle Pacing:Rebirth of an Important Technique for Pacing the Intrinsic Conduction System
16
作者 Michael R.Kaufmann Matthew S.McKillop +3 位作者 Thomas A.Burkart Mark Panna William M.Miles C.Richard Conti 《Cardiovascular Innovations and Applications》 2018年第B05期61-71,共11页
Permanent pacemaker implant is a commonly performed cardiac procedure for treatment of bradycardia or conduction system abnormality.With conventional right ventricular(RV)pacing a lead is implanted at the RV apex or o... Permanent pacemaker implant is a commonly performed cardiac procedure for treatment of bradycardia or conduction system abnormality.With conventional right ventricular(RV)pacing a lead is implanted at the RV apex or on the RV septum.However,RV apical or RV septal pacing causes iatrogenic left bundle-branch block and ventricular dyssynchrony and can lead to adverse cardiac remodeling,a pacing-mediated cardiomyopathy,and congestive heart failure.Alternatively,permanent His-bundle pacing uses the intrinsic rapidly-conducting His-Purkinje system to activate the ventricle,thereby maintaining(or sometimes even restoring)ventricular synchrony.Many patients may derive benefit from permanent His-bundle pacing. 展开更多
关键词 His-bundle pacing VENTRICULAR DYSSYNCHRONY cardiac RESYNCHRONIZATION therapy permanent pacing
下载PDF
Systemic venous atrium stimulation in transvenous pacing after mustard procedure
17
作者 Calogero Puntrello Fabiana Lucà +2 位作者 Gaspare Rubino Carmelo Massimiliano Rao Sandro Gelsomino 《World Journal of Cardiology》 CAS 2014年第9期1041-1044,共4页
We present the case of a young woman corrected with a Mustard procedure undergoing successful transvenous double chamber pacemaker implantation with the atrial lead placed in the systemic venous channel. The case pres... We present the case of a young woman corrected with a Mustard procedure undergoing successful transvenous double chamber pacemaker implantation with the atrial lead placed in the systemic venous channel. The case presented demonstrates that, when the systemic venous atrium is separate from the left atrial appendage, the lead can be easily and safely placed in the systemic venous left atrium gaining satisfactory sensing and pacing thresholds despite consisting partially of pericardial tissue. 展开更多
关键词 pacing young corrected satisfactory safely STIMULATION implantation gaining chamber VENTRICLE
下载PDF
IN VIVO CHARACTERIZATION OF ATTACHMENT SAFETY BETWEEN CARDIAC PACING LEAD AND CANINE HEART MUSCLE
18
作者 Zhang Xiangming Niu Guodong +3 位作者 Ma Nianke Fan Hualin Zhao Yong Yang Wei 《Acta Mechanica Solida Sinica》 SCIE EI 2007年第3期189-197,共9页
In vivo experiments of screwing the electrode of canine hearts and assigning external excitation on the lead-myocardium interface was carried out to evaluate the lead/myocardium adherence safety. The electrode is spec... In vivo experiments of screwing the electrode of canine hearts and assigning external excitation on the lead-myocardium interface was carried out to evaluate the lead/myocardium adherence safety. The electrode is specially designed to host a measurement unit of strain gauges. We obtained the lead/heart interactions data from 12 dogs under natural heart beating and beating with external excitations. The data recorded from the acute phase and the chronic phase of pulling out pacing leads were compared with each other. The electrode/heart interaction is caused by the heart beat and influenced by the lung breath. This process induced tolerable damage to the lead or myocardium. The interaction decreases as the frequency of external excitations increases. The lead is more likely to be detached from myocardium under higher excitation frequency. At the same implanting sites, safer pacing lead/myocardium attachment can be realized in the chronic tests than in the acute tests. 展开更多
关键词 biomechanics pacing in vivo MYOCARDIUM attachment safety
下载PDF
Pacing profiles and tactical behaviors of elite runners
19
作者 Arturo Casado Brian Hanley +1 位作者 Pedro Jimenez-Reyes Andrew Renfree 《Journal of Sport and Health Science》 SCIE 2021年第5期537-549,共13页
The pacing behaviors used by elite athletes differ among individual sports,necessitating the study of sport-specific pacing profiles.Additionally,pacing behaviors adopted by elite runners differ depending on race dist... The pacing behaviors used by elite athletes differ among individual sports,necessitating the study of sport-specific pacing profiles.Additionally,pacing behaviors adopted by elite runners differ depending on race distance.An“all-out”strategy,characterized by initial rapid acceleration and reduction in speed in the later stages,is observed during 100 m and 200 m events;400 m runners also display positive pacing patterns,which is characterized by a reduction in speed throughout the race.Similarly,800 m runners typically adopt a positive pacing strategy during paced“meet”races.However,during championship races,depending on the tactical approaches used by dominant athletes,pacing can be either positive or negative(characterized by an increase in speed throughout).A U-shaped pacing strategy(characterized by a faster start and end than during the middle part of the race)is evident during world record performances at meet races in 1500 m,5000 m,and 10,000 m events.Although a parabolic J-shaped pacing profile(in which the start is faster than the middle part of the race but is slower than the endspurt)can be observed during championship 1500 m races,a negative pacing strategy with microvariations of pace is adopted by 5000 m and 10,000 m runners in championship races.Major cross country and marathon championship races are characterized by a positive pacing strategy;whereas a U-shaped pacing strategy,which is the result of a fast endspurt,is adopted by 3000 m steeplechasers and half marathoners.In contrast,recent world record marathon performances have been characterized by even pacing,which emphasizes the differences between championship and meet races at distances longer than 800 m.Studies reviewed suggest further recommendations for athletes.Throughout the whole race,800 m runners should avoid running wide on the bends.In turn,during major championship events,1500 m,5000 m,and 10,000 m runners should try to run close to the inside of the track as much as possible during the decisive stages of the race when the speed is high.Staying within the leading positions during the last lap is recommended to optimize finishing position during 1500 m and 5000 m major championship races.Athletes with more modest aims than winning a medal at major championships are advised to adopt a realistic pace during the initial stages of long-distance races and stay within a pack of runners.Coaches of elite athletes should take into account the observed difference in pacing profiles adopted in meet races vs.those used in championship races:fast times achieved during races with the help of one or more pacemakers are not necessarily replicated in winner-takes-all championship races,where pace varies substantially.Although existing studies examining pacing characteristics in elite runners through an observational approach provide highly ecologically valid performance data,they provide little information regarding the underpinning mechanisms that explain the behaviors shown.Therefore,further research is needed in order to make a meaningful impact on the discipline.Researchers should design and conduct interventions that enable athletes to carefully choose strategies that are not influenced by poor decisions made by other competitors,allowing these athletes to develop more optimal and successful behaviors. 展开更多
关键词 ATHLETICS Distance running pacing SPRINTING
下载PDF
Comparison of electrocardiogram characteristics between left bundle branch pacing and right ventricular septal pacing in patients receiving pacemaker therapy
20
作者 Yuqiu Li Keping Chen +4 位作者 Yan Dai Qi Sun Bin Luo Chao Li Shu Zhang 《中国循环杂志》 CSCD 北大核心 2018年第S01期155-155,共1页
Background and Objective Cardiac pacing is an effective therapy in patients with bradycardia.Conventional right ventricular(RV)pacing is the source of ventricular dyssynchrony,leading to unfavorable clinical outcome.T... Background and Objective Cardiac pacing is an effective therapy in patients with bradycardia.Conventional right ventricular(RV)pacing is the source of ventricular dyssynchrony,leading to unfavorable clinical outcome.This study compared the electrocardiogram(ECG)characteristics during left bundle branch pacing(LBBP)with that during RV septal pacing(RVSP)which has been thought to be better than RV apical pacing. 展开更多
关键词 RIGHT VENTRICULAR ELECTROCARDIOGRAM RV SEPTAL pacing
下载PDF
上一页 1 2 22 下一页 到第
使用帮助 返回顶部