The Impact of Cardiac Pacing Site on Patient's Cardiac Function and Psychological State
1
作者 Haiyang Xiao Liang Sun 《Expert Review of Chinese Medical》 2024年第2期18-22,共5页
With the widespread application of artificial permanent pacemakers in clinical practice,there have been new changes in the indications for pacemaker implantation.The current clinical indications include high atriovent... With the widespread application of artificial permanent pacemakers in clinical practice,there have been new changes in the indications for pacemaker implantation.The current clinical indications include high atrioventricular block,sick sinus syndrome,cardiac resynchronization therapy for heart failure,and implantation of cardioverter defibrillators for ventricular arrhythmias.The implantation of a pacemaker can improve the quality of life and prognosis of patients with arrhythmia.In the past,permanent pacemaker implantation was performed in clinical practice,and the right ventricular pacing electrode was often fixed at the apex of the right ventricle,which belongs to non physiological pacing.Through long-term clinical follow-up,it was found that apex pacing can easily cause abnormal depolarization of the left ventricle,asynchronous contraction of the myocardium,and ultimately lead to myocardial fibrosis,which has adverse effects on the patient's cardiac function and psychological state.In recent years,Scholars have found that pacing in the right ventricular outflow tract septum is closer to the atrioventricular node and closer to the His bundle Purkinje fibers.The pacing impulse almost simultaneously expands towards both ventricles,closer to the physiological pacing state,thereby reducing the occurrence of cardiovascular events in patients.This article explores the impact of pacing in different parts of the heart on the cardiac function and psychological state of patients based on clinical data from the past three years. 展开更多
关键词 pacing site cardiac function psychological state
下载PDF
Implantation of Lumenless Pacing Leads at the Inter-atrial Septum and Right Ventricular Outflow Tract with Deflectable Catheter-sheath
2
作者 白融 Ruth KAM +2 位作者 Chi Keong CHING Li Fern HSU Wee Siong TEO 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第6期639-644,共6页
Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation patt... Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation pattern, which results in asynchronous ventricular contraction and relaxation. When pacing from right atrial appendage, the conduction time between two atria will be prolonged, which results in heterogeneity for both depolarization and repolarization. Six patients with Class Ⅰ indication for permanent pacing were implanted with either single chamber or dual chamber pacemaker. The SelectSecure 3830 4-French (Fr) lumenless lead and the SelectSite C304 8.5-Fr steerable catheter-sheath (Medtronic Inc., USA) were used. Pre-selected pacing sites included inter-atrial septum and right ventricular outflow tract, which were defined by ECG and fluoroscopic criteria. All the implanting procedures were successful without complication. Testing results (mean atrial pacing threshold: 0.87 V; mean P wave amplitude: 2.28 mV; mean ventricular pacing threshold: 0.53V; mean R wave amplitude: 8.75 mV) were satisfactory. It is concluded that implantation of a 4-Fr lumenless pacing lead by using a streerable catheter-sheath to achieve inter-atrial septum or right ventricular outflow tract pacing is safe and feasible. 展开更多
关键词 selective site pacing lumenless lead inter-atrial septum right ventricular outflow tract
下载PDF