The maximum-efficiency inlet velocity(MEIV)is a ceiling of inlet gas velocity that defines separation efficiency during cyclone design and operation.Experiment and computational fluid dynamics(CFD)simulation exhibited...The maximum-efficiency inlet velocity(MEIV)is a ceiling of inlet gas velocity that defines separation efficiency during cyclone design and operation.Experiment and computational fluid dynamics(CFD)simulation exhibited that an apex cone at the dust outlet can break the ceiling and improve the sepa-ration efficiency.The phenomenon is closely related to the effect of excessive high inlet gas velocity on the back-mixing escape of fine particles,which is the final result of back mixing,entrainment by the rapid upward airflow,and secondary separation of the inner vortex.In the center of the inner vortex,the airflow rotates slowly and moves rapidly upward.This elevator type of airflow delivers re-entrained particles to the vortex finder.A higher inlet gas velocity accelerates the elevator,causing more entrained particles to escape.This explains the decrease in efficiency at an excessively high inlet gas velocity.When an apex cone is installed at the dust outlet,the back-mixing is significantly weakened because the vortex core is bounded to the center of separator,while the transport effect of rapid upward airflow is weakened by the decrease in axial velocity in the center.Therefore,particle escape is weakened even at excessive high inlet gas velocities.Instead,the centrifugal effect is enhanced because of increased tangential velocity of the gas and particles.Consequently,the ceiling of inlet gas velocity is broken.展开更多
基金supported by Fundamental Research Program of Shanxi Province(No.202203021211164)supported by the National Natural Science Foundation of China(No.22108262)+2 种基金Shanxi Province Science Foundation for Youths(No.20210302124600)Shanxi Province Foundation for Returness(No.2022-138)Fund Program for the Scientific Activities of Selected Returned Overseas Professionals in Shanxi Province(No.20220014).
文摘The maximum-efficiency inlet velocity(MEIV)is a ceiling of inlet gas velocity that defines separation efficiency during cyclone design and operation.Experiment and computational fluid dynamics(CFD)simulation exhibited that an apex cone at the dust outlet can break the ceiling and improve the sepa-ration efficiency.The phenomenon is closely related to the effect of excessive high inlet gas velocity on the back-mixing escape of fine particles,which is the final result of back mixing,entrainment by the rapid upward airflow,and secondary separation of the inner vortex.In the center of the inner vortex,the airflow rotates slowly and moves rapidly upward.This elevator type of airflow delivers re-entrained particles to the vortex finder.A higher inlet gas velocity accelerates the elevator,causing more entrained particles to escape.This explains the decrease in efficiency at an excessively high inlet gas velocity.When an apex cone is installed at the dust outlet,the back-mixing is significantly weakened because the vortex core is bounded to the center of separator,while the transport effect of rapid upward airflow is weakened by the decrease in axial velocity in the center.Therefore,particle escape is weakened even at excessive high inlet gas velocities.Instead,the centrifugal effect is enhanced because of increased tangential velocity of the gas and particles.Consequently,the ceiling of inlet gas velocity is broken.