Objective: Study the contribution of the DIVA 3D dissection table in the teaching of anatomy at the Faculty of Medicine and Odontology of Bamako. Material and Methods: This was a qualitative study carried out from Nov...Objective: Study the contribution of the DIVA 3D dissection table in the teaching of anatomy at the Faculty of Medicine and Odontology of Bamako. Material and Methods: This was a qualitative study carried out from November 1 to December 30, 2023 at the clinical and morphological anatomy laboratory of the Faculty of Medicine and Odontostomatology of Bamako. Included in this study were students who participated in practical and tutorial sessions. The variables studied during this study were: the previous performance of dissection on a cadaver by the students, the opinion of the students on dissection on a cadaver, the replacement of dissection on a cadaver by virtual dissection in the absence of a body, the level student satisfaction. Results: We surveyed 130 participants. The average age was 22 ± 0.2 years with extremes of 17 and 29 years. 95.3% of participants were students. According to 66.7% of participants, virtual dissection is a good palliative in the absence of a corpse. 95.3% of participants found using the virtual dissection table easy with an average of 7.88 ± 1.4. The overall assessment was well rated by 99.3% of participants. Conclusion: According to the results of this study, the virtual dissection table should be improved by integrating commented videos. The use of the DIVA 3D virtual dissection table during practical and tutorial sessions is well appreciated by the students. We believe that the teaching of anatomy using 3D digital technology should be included in the study programs of the Faculty of Medicine and Odontostomatology.展开更多
[ Objective] To detect polymorphism of intron 14 of porcine CACNA2Dt gene and thus provide conditions for the marker-assisted selec- tion of pork quality traits. [Method] The polymorphism of the exon 14 and intron 14 ...[ Objective] To detect polymorphism of intron 14 of porcine CACNA2Dt gene and thus provide conditions for the marker-assisted selec- tion of pork quality traits. [Method] The polymorphism of the exon 14 and intron 14 of porcine CACNA2D1 gene was detected in six breeds by PCR- SSCP. The genetic effects of different genotypes on the pH45 value of eye muscle and ham joint muscle were also analyzed. I-Result] There were three kinds of genotypes, namely, AA, AG and GG, in the intron 14 of porcine CACNA2 DI gene. The polymorphic locus ( G --~ A) was at the 1 145 nt of the sequence (GenBank Accepted No. FJ156361 ). The results of X2 test showed that the distribution of these three kinds of genotypes was significantly different in the six breeds (P〈0.05). The pH45 values of eye muscle and ham joint muscle were significantly different between geno- type AA and genotype AG of pigs in F2 generation from the Jianhua x Pietrain resource family ( P 〈 0.05). [Conclusion ] The polymorphism of the in- tron 14 of porcine CACNA2D1 gene has effects on the pH45 values of eye muscle and ham joint muscle.展开更多
A series of extraction equilibrium experiments for aminobenzoic acid with di(2-ethylhexyl)phosphoric acid (D2EHPA) dissolved in n-octane or 1-octanol was carried out. The effects of aminobenzoic acid concentration,D2E...A series of extraction equilibrium experiments for aminobenzoic acid with di(2-ethylhexyl)phosphoric acid (D2EHPA) dissolved in n-octane or 1-octanol was carried out. The effects of aminobenzoic acid concentration,D2EHPA concentration and pH on the distribution ratio were discussed in detail. The infrared spectra of the organic phase loaded with solute illustrated that pH had little effect on the structure of the complex formed. There proceed ion association and cation-exchange.reaction in the extraction. An expression of the equilibrium distribution was proposed.展开更多
3D evaluation method of cutting surface topography for C/Ph composites was established.The cutting surface was measured by Talyscan 150,using 3D non-contact measurement.Through the results of 2D and 3D roughness evalu...3D evaluation method of cutting surface topography for C/Ph composites was established.The cutting surface was measured by Talyscan 150,using 3D non-contact measurement.Through the results of 2D and 3D roughness evaluating for C/Ph composite and Duralumin,the 2D evaluation method of the cutting surface topography of C/Ph composite loses a lot of information,the characteristics of the surface topography of C/Ph composite can be comprehensively and authentically evaluated only by 3D evaluation method.Furthermore,3D amplitude and spatial parameters were adopted to evaluate the surface.The results show that: the topography of the C/Ph composite is anisotropic,there are more valleys in the machined surface of C/Ph than that of duralumin,and there are not obvious feeding textures for C/Ph,which indicates the machining mechanism is different from the metal.In conclusion,the topography of the C/Ph composite cutting surface is anisotropic;the cutting surface of C/Ph composite needs 3D evaluation method.展开更多
文摘Objective: Study the contribution of the DIVA 3D dissection table in the teaching of anatomy at the Faculty of Medicine and Odontology of Bamako. Material and Methods: This was a qualitative study carried out from November 1 to December 30, 2023 at the clinical and morphological anatomy laboratory of the Faculty of Medicine and Odontostomatology of Bamako. Included in this study were students who participated in practical and tutorial sessions. The variables studied during this study were: the previous performance of dissection on a cadaver by the students, the opinion of the students on dissection on a cadaver, the replacement of dissection on a cadaver by virtual dissection in the absence of a body, the level student satisfaction. Results: We surveyed 130 participants. The average age was 22 ± 0.2 years with extremes of 17 and 29 years. 95.3% of participants were students. According to 66.7% of participants, virtual dissection is a good palliative in the absence of a corpse. 95.3% of participants found using the virtual dissection table easy with an average of 7.88 ± 1.4. The overall assessment was well rated by 99.3% of participants. Conclusion: According to the results of this study, the virtual dissection table should be improved by integrating commented videos. The use of the DIVA 3D virtual dissection table during practical and tutorial sessions is well appreciated by the students. We believe that the teaching of anatomy using 3D digital technology should be included in the study programs of the Faculty of Medicine and Odontostomatology.
文摘[ Objective] To detect polymorphism of intron 14 of porcine CACNA2Dt gene and thus provide conditions for the marker-assisted selec- tion of pork quality traits. [Method] The polymorphism of the exon 14 and intron 14 of porcine CACNA2D1 gene was detected in six breeds by PCR- SSCP. The genetic effects of different genotypes on the pH45 value of eye muscle and ham joint muscle were also analyzed. I-Result] There were three kinds of genotypes, namely, AA, AG and GG, in the intron 14 of porcine CACNA2 DI gene. The polymorphic locus ( G --~ A) was at the 1 145 nt of the sequence (GenBank Accepted No. FJ156361 ). The results of X2 test showed that the distribution of these three kinds of genotypes was significantly different in the six breeds (P〈0.05). The pH45 values of eye muscle and ham joint muscle were significantly different between geno- type AA and genotype AG of pigs in F2 generation from the Jianhua x Pietrain resource family ( P 〈 0.05). [Conclusion ] The polymorphism of the in- tron 14 of porcine CACNA2D1 gene has effects on the pH45 values of eye muscle and ham joint muscle.
文摘A series of extraction equilibrium experiments for aminobenzoic acid with di(2-ethylhexyl)phosphoric acid (D2EHPA) dissolved in n-octane or 1-octanol was carried out. The effects of aminobenzoic acid concentration,D2EHPA concentration and pH on the distribution ratio were discussed in detail. The infrared spectra of the organic phase loaded with solute illustrated that pH had little effect on the structure of the complex formed. There proceed ion association and cation-exchange.reaction in the extraction. An expression of the equilibrium distribution was proposed.
基金Funded by the National Natural Science Foundation of China(No.50875036)
文摘3D evaluation method of cutting surface topography for C/Ph composites was established.The cutting surface was measured by Talyscan 150,using 3D non-contact measurement.Through the results of 2D and 3D roughness evaluating for C/Ph composite and Duralumin,the 2D evaluation method of the cutting surface topography of C/Ph composite loses a lot of information,the characteristics of the surface topography of C/Ph composite can be comprehensively and authentically evaluated only by 3D evaluation method.Furthermore,3D amplitude and spatial parameters were adopted to evaluate the surface.The results show that: the topography of the C/Ph composite is anisotropic,there are more valleys in the machined surface of C/Ph than that of duralumin,and there are not obvious feeding textures for C/Ph,which indicates the machining mechanism is different from the metal.In conclusion,the topography of the C/Ph composite cutting surface is anisotropic;the cutting surface of C/Ph composite needs 3D evaluation method.