Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography
1
作者 Gang Guo Yonggui Yang Weiqun Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第30期2367-2371,共5页
The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC ... The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries. 展开更多
关键词 two-dimensional phase-contrast magnetic resonance angiography blood flow three-dimensional time-of-flight phase-contrast magnetic resonance angiography internal carotid artery common carotid artery external carotid artery velocity encoding
下载PDF
Visibility in differential phase-contrast imaging with partial coherence source 被引量:3
2
作者 刘鑫 郭金川 +1 位作者 彭翔 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第6期1632-1636,共5页
This paper gives theoretical analysis of visibility of fringes, which is influenced by distances, temporal and spatial coherence of source, in hard x-ray differential phase-contrast imaging with microfocus x-ray sourc... This paper gives theoretical analysis of visibility of fringes, which is influenced by distances, temporal and spatial coherence of source, in hard x-ray differential phase-contrast imaging with microfocus x-ray source. According to the character of longitudinal periodicity of the interferogram, the setup is insensitive to mechanical drift and vibrations. The effect of temporal coherence of x-ray source is investigated and its related bandwidth is derived. Based on the theory of partially coherent light, it shows that the requirement for the spatial coherence of x-ray source is not strict and can be met by the general microfocus x-ray tube for x-ray differential phase-contrast imaging. 展开更多
关键词 VISIBILITY differential phase-contrast interference fringes phase grating
下载PDF
Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts 被引量:1
3
作者 冀东江 渠刚荣 +3 位作者 胡春红 刘宝东 简建波 郭晓坤 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第6期93-100,共8页
In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, r... In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, ring artifacts which will reduce the image quality are commonly encountered in IL-PC-CT, and numerous correction methods exist to either pre-process the sinogram or post-process the reconstructed image. In this study, we develop an IL-PC-CT reconstruction method based on anisotropic total variation(TV) minimization. Using this method, the ring artifacts are corrected during the reconstruction process. This method is compared with two methods: a sinogram preprocessing correction technique based on wavelet-FFT filter and a reconstruction method based on isotropic TV. The correction results show that the proposed method can reduce visible ring artifacts while preserving the liver section details for real liver section synchrotron data. 展开更多
关键词 SART anisotropic TV in-line phase-contrast
下载PDF
Quantitative assessment of physiological cerebrospinal fluid flow in the cervical spinal canal with 3.0T phase-contrast cine MRI
4
作者 Hua Shang Huaijun +3 位作者 Liu Leka Yan Jianming Lei Caixia Cui Hui Li 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第18期1392-1397,共6页
A total of 50 healthy volunteers aged between 18 and 54 years underwent phase-contrast cine MR to assess cerebrospinal fluid flow characteristics in different regions of the vertebral canal. The results revealed that ... A total of 50 healthy volunteers aged between 18 and 54 years underwent phase-contrast cine MR to assess cerebrospinal fluid flow characteristics in different regions of the vertebral canal. The results revealed that the cerebrospinal fluid peak flow velocity and peak flow rate in the systolic phase were significantly greater than those in the diastolic phase at the same level in the subarachnoid space of the cervical spinal canal. The ventral peak flow velocity and peak flow rate were significantly greater than the post-lateral peak flow velocity and flow rate, while there were no differences between left and right post-lateral subarachnoid peak velocity and flow rate. Moreover, there were no significant differences in peak flow velocity and peak flow rate between the systolic and diastolic phases, ventral, right post-lateral or left post-lateral peak flow velocity and peak flow rate at the same level in the subarachnoid space of the cervical spinal canal among different age groups (18 24, 25 34, 35-44, ≥45 years). 展开更多
关键词 magnetic resonance imaging phase-contrast cerebrospinal fluid vertebral canal subarachnoidspace flow velocity neural regeneration
下载PDF
Optimal velocity encoding during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography
5
作者 Gang Guo Yonggui Yang Weiqun Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第23期1796-1800,共5页
This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-con... This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-contrast magnetic resonance angiography slice was applied perpendicular to the internal carotid artery and the vertebral artery at C2 level. For each subject, the velocity encoding was set from 30 to 90 cm/s with an interval of 10 cm/s for a total of seven settings. Various velocity encodings greatly affected blood flow volume, maximal blood flow velocity and mean blood flow velocity in the internal carotid artery, but did not significantly affect vertebral arteries and jugular veins. When velocity encoding was 60-80 cm/s, the inflow blood volume was 655 _+ 118 mL/min, and the outflow volume was 506 _+ 186 mL/min. The ratio of outflow/inflow was steady at 0.78-0.83, and there was no aliasing in any of the images. These findings suggest that velocity encodings of 60 80 cm/s should be selected during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography. 展开更多
关键词 cerebral blood flow velocity encoding phase-contrast magnetic resonance imaging
下载PDF
Noise properties of multi-combination information in x-ray grating-based phase-contrast imaging
6
作者 Wali Faiz Ji Li +4 位作者 Kun Gao Zhao Wu Yao-Hu Lei Jian-Heng Huang Pei-Ping Zhu 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第1期329-335,共7页
Grating-based x-ray phase contrast imaging has attracted increasing interest in recent decades as multimodal and laboratory source usable method.Specific efforts have been focused on establishing a new extraction meth... Grating-based x-ray phase contrast imaging has attracted increasing interest in recent decades as multimodal and laboratory source usable method.Specific efforts have been focused on establishing a new extraction method to perform practical applications.In this work,noise properties of multi-combination information of newly established information extraction method,so-called angular signal radiography method,are investigated to provide guidelines for targeted and specific applications.The results show that how multi-combination of images can be used in targeted practical applications to obtain a high-quality image in terms of signal-to-noise ratio.Our conclusions can also hold true for upcoming targeted practical applications such as biomedical imaging,non-destructive imaging,and materials science. 展开更多
关键词 grating-based phase-contrast imaging signal-to-noise ratio REFRACTION SCATTERING
下载PDF
Effects of Tube Voltage on Phase-Contrast Imaging for Different Microfocus X-Ray Tubes
7
作者 Jianbao Gui Zhanli Hu +1 位作者 Peter Z. Wu Hairong Zheng 《Engineering(科研)》 2013年第10期590-594,共5页
In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltag... In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltage (kVp) on propagation-based phase-contrast imaging have been investigated with two types of microfocus x-ray tubes, a conventional sealed x-ray tube with the focal spot size of 13 - 20 μm and an open x-ray tube with minimum focal spot size less than 2 μm. A cooled x-ray CCD detector with the pixel size of 24 μm was used to acquire digital images. Two thin plastic sheets with different thickness were used as radiography phantoms. Two different phenomena were observed for the two x-ray tubes. For the open tube, phase-contrast effect has a slight drop with the increasing of tube voltage, however, it is opposite for the sealed tube. A further investigation indicates that the variation of focal spot size causes the abnormal result for the sealed tube. It also shows that phase-contrast effect is more sensitive to focal spot size than tube voltage. 展开更多
关键词 phase-contrast Imaging EDGE Enhancement X-RAY TUBE VOLTAGE
下载PDF
Application of phase-contrast cine gnetic resonance imaging (MRI) in endoscopic aqueductoplasty
8
作者 郑佳平 《外科研究与新技术》 2011年第3期222-223,共2页
Objective To evaluate the application of phasecontrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty for patients with obstructive hydrocephalus. Methods The clinical diagnosis of hydrocephalus d... Objective To evaluate the application of phasecontrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty for patients with obstructive hydrocephalus. Methods The clinical diagnosis of hydrocephalus due to aqueduct obstruction in 23 patients was confirmed by phase contrast cine MRI examination. 展开更多
关键词 MRI in endoscopic aqueductoplasty Application of phase-contrast cine gnetic resonance imaging
下载PDF
In-line X-ray phase-contrast imaging of murine liver microvasculature ex vivo 被引量:5
9
作者 LI Beilei XU Min +5 位作者 WU Weizhong PENG Guanyun ZHANG Xi PENG Yifeng SHI Hongcheng CHEN Shaoliang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2012年第1期10-14,共5页
Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.V... Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility.Barium sulfate and physiological saline were used as contrast agents for the blood vessels.Blood vessels of <Φ20μm could be detected by replacing resident blood with physiological saline or barium sulfate.An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image.It is demonstrated that selective angiography based on phase contrast X-ray imaging,with a physiological material of low Z elements (such as saline) being the contrast agent,is a viable imaging strategy.Further efforts will be focused on using the technique to image tumor angiogenesis. 展开更多
关键词 X射线成像 相衬成像 微血管 体外 小鼠 上海同步辐射装置 肿瘤血管生成 生理盐水
下载PDF
A new method of detecting interferogram in differential phase-contrast imaging system based on special structured x-ray scintillator screen 被引量:6
10
作者 刘鑫 郭金川 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期193-197,共5页
An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and ... An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and difficulty of fabrication by a state of the art technique. On the basis of phase grating diffraction, a detecting model of the scintillator screen was built for analysing the phase and absorption information of objects. According to the analysis, a new method of phase retrievals based on two-images and the optimal structure of screen were presented. 展开更多
关键词 differential phase contrast x-ray scintillator screen phase retrieval
下载PDF
Computational Fluid Dynamics and Its Impact on Flow Measurements Using Phase-Contrast MR-Angiography
11
作者 Claus Kiefer Frauke Kellner-Weldon 《Open Journal of Medical Imaging》 2012年第1期23-28,共6页
Rationale and Objectives: Computational fluid dynamic (CFD) simulations are discussed with respect to their potential for quality assurance of flow quantification using commercial software for the evaluation of magnet... Rationale and Objectives: Computational fluid dynamic (CFD) simulations are discussed with respect to their potential for quality assurance of flow quantification using commercial software for the evaluation of magnetic resonance phase contrast angiography (PCA) data. Materials and Methods: Magnetic resonance phase contrast angiography data was evaluated with the Nova software. CFD simulations were performed on that part of the vessel system where the flow behavior was unexpected or non-reliable. The CFD simulations were performed with in-house written software. Results: The numerical CFD calculations demonstrated that under reasonable boundary conditions, defined by the PCA velocity values, the flow behavior within the critical parts of the vessel system can be correctly reproduced. Conclusion: CFD simulations are an important extension to commercial flow quantification tools with regard to quality assurance. 展开更多
关键词 CFD Flow PHASE CONTRAST ANGIOGRAPHY Quality ASSURANCE
下载PDF
Cine PC-MRI技术在Arnold-Chiari畸形手术疗效评估中的应用
12
作者 韩向前 王文学 +7 位作者 王远成 李长城 李春阳 王建伟 苗重昌 孙毅 徐开喜 张名忠 《中国CT和MRI杂志》 2024年第9期26-28,共3页
目的探讨相位对比电影-磁共振成像(Cine PC-MRI)技术在小脑扁桃体下疝(Arnold-Chiari)畸形手术疗效评估中的应用。方法选取2018年8月—2022年9月期间多中心收集的65例行Arnold-Chiari畸形手术治疗的患者作为研究对象。术后均随访6个月... 目的探讨相位对比电影-磁共振成像(Cine PC-MRI)技术在小脑扁桃体下疝(Arnold-Chiari)畸形手术疗效评估中的应用。方法选取2018年8月—2022年9月期间多中心收集的65例行Arnold-Chiari畸形手术治疗的患者作为研究对象。术后均随访6个月。比较患者术前、术后6个月的预后、生活质量、寰齿间距(ADI)值、脊髓空洞直径、后颅窝斜坡长度、枕骨大孔横径、后颅窝高径长度及脑脊液流速,随访期间的并发症情况。结果术后6个月,患者芝加哥Chiari结果量表(CCOS)评分及健康相关生活质量评分(HRQoL)高于术前(P<0.05);随访期间,有3例进行枕大池重建术的患者伤口发生脑脊液漏,给予腰大池引流,7d后伤口愈合良好。术后6个月,患者寰齿间距(ADI)值及脊髓空洞直径低于术前;后颅窝斜坡长度及后颅窝高径长度长于术前;桥脑延髓池层面、中脑导水管层面及颈椎间盘层面的每搏输出量(SV)、平均流量(MF)均高于术前;头向峰值流速(Vumax)、足向峰值流速(Vdmax)均低于术前(P<0.05)。结论Arnold-Chiari畸形患者经外科手术治疗可有效改善预后并提高生活质量,但行枕大池重建术时要注意防范脑脊液漏的发生,而Cine PC-MRI技术可为Arnold-Chiari畸形患者手术治疗疗效评估提供有效依据。 展开更多
关键词 小脑扁桃体下疝畸形 相位对比电影-磁共振成像 手术
下载PDF
对比增强SWI对不同病理类型肺癌脑转移瘤的诊断价值 被引量:1
13
作者 吴立业 罗文明 +2 位作者 蒋锡丽 黄子龙 刘军 《放射学实践》 CSCD 北大核心 2024年第1期55-59,共5页
目的:探讨对比增强磁敏感加权成像(CE-SWI)与常规对比增强T 1WI成像(CE-T 1WI)对不同病理类型肺癌脑转移瘤的检出率差异,分析脑转移瘤内出现对比剂诱导相移(CIPS)与原发性肺癌病理类型间的关联性。方法:搜集经病理证实的79例原发性肺癌... 目的:探讨对比增强磁敏感加权成像(CE-SWI)与常规对比增强T 1WI成像(CE-T 1WI)对不同病理类型肺癌脑转移瘤的检出率差异,分析脑转移瘤内出现对比剂诱导相移(CIPS)与原发性肺癌病理类型间的关联性。方法:搜集经病理证实的79例原发性肺癌患者,其中腺癌组40例,鳞癌组18例,小细胞癌组21例,均行颅脑MR常规平扫、SWI、CE-T 1WI及CE-SWI检查,比较CE-SWI与CE-T 1WI检出的脑转移瘤数目及转移瘤内是否存在CIPS,转移灶经3个月后随访证实。结果:CE-T 1WI与CE-SWI对腺癌脑转移瘤的检出率差异有统计学意义(χ^(2)=5.05,P=0.025),对鳞癌(χ^(2)=0.00,P=1.000)与小细胞癌(χ^(2)=0.27,P=0.603)脑转移瘤的检出率差异无统计学意义。腺癌组、鳞癌组、小细胞癌组三组间CIPS阳性率差异有统计学意义(χ^(2)=11.13,P=0.004),其中鳞癌组与腺癌组(χ^(2)=11.08,P=0.001)、鳞癌组与小细胞癌组(χ^(2)=8.26,P=0.004)间差异有统计学意义,腺癌组与小细胞癌组间差异无统计学意义(χ^(2)=0.131,P=0.717)。结论:CE-SWI对肺腺癌脑转移瘤的检出较CE-T 1WI更有优势。肺腺癌、小细胞癌脑转移瘤的CIPS阳性率较鳞癌显著增高,CE-SWI可为肺癌脑转移瘤MRI检查常规序列的有利补充,为临床诊疗提供更多重要参考信息。 展开更多
关键词 肺肿瘤 脑转移瘤 磁敏感加权成像 磁共振成像 对比剂诱导相移
下载PDF
7T磁共振成像在脑小血管病中的应用进展
14
作者 黄沛钰 刘晨 +1 位作者 甄志铭 张睿婷 《磁共振成像》 CAS CSCD 北大核心 2024年第9期151-156,共6页
脑小血管病在老年人群具有很高的发病率,可显著增加脑卒中和痴呆的发生风险。迄今为止,该疾病尚无有效的临床和体液生物标志物,诊断鉴别高度依赖于MRI。然而,由于临床影像的空间分辨率所限,脑小血管损害难以直接评价,因此研究者们主要... 脑小血管病在老年人群具有很高的发病率,可显著增加脑卒中和痴呆的发生风险。迄今为止,该疾病尚无有效的临床和体液生物标志物,诊断鉴别高度依赖于MRI。然而,由于临床影像的空间分辨率所限,脑小血管损害难以直接评价,因此研究者们主要使用一些反映脑实质损害的影像标志物来评估小血管损伤。近年来,随着超高场(7T)MRI技术的不断成熟,其在脑小血管病领域的研究亦日趋广泛。7T-MRI能够直接评估脑小血管结构、功能,并显著提高微小脑实质病灶的检测敏感性,为脑小血管病机制研究和精准诊断提供了重要工具。本文将回顾近年来基于7T-MRI的脑小血管病研究,并讨论潜在的问题和未来研究方向,为相关研究工作者提供借鉴。 展开更多
关键词 脑小血管病 磁共振成像 超高场强 时间飞跃法磁共振血管成像 相位对比磁共振血管成像 磁敏感加权成像
下载PDF
基于最大对比度的联合相位误差校正方法
15
作者 张超 张榆红 张益鑫 《现代雷达》 CSCD 北大核心 2024年第4期110-115,共6页
针对高分辨率逆合成孔径雷达(ISAR)成像过程中,因目标转动所引入的转动相位误差无法被忽略,以及由于转动相位误差使得传统平动相位误差校正方法性能严重下降的问题,提出了一种基于最大对比度的联合相位误差校正的方法,可同时校正残余的... 针对高分辨率逆合成孔径雷达(ISAR)成像过程中,因目标转动所引入的转动相位误差无法被忽略,以及由于转动相位误差使得传统平动相位误差校正方法性能严重下降的问题,提出了一种基于最大对比度的联合相位误差校正的方法,可同时校正残余的平动相位误差和转动相位误差,进一步提高成像的质量。首先利用传统的运动补偿方法对回波信号进行处理,其次根据最大对比度准则,将相位误差校正问题转化为最大对比度优化问题,最后利用改进的拟牛顿算法进行求解。该方法能使高分辨率ISAR进行精准成像,且所得图像聚焦效果良好。通过对仿真数据和实测数据的处理,验证了文中方法的有效性。 展开更多
关键词 逆合成孔径雷达 最大对比度 拟牛顿算法 相位误差
下载PDF
HL-2A装置相衬成像系统的安全连锁与远程监控
16
作者 龚少博 余羿 +11 位作者 王志斌 王华杰 袁金榜 刘灏 吴婷 龙婷 陈逸航 柯锐 聂林 王占辉 孙爱萍 许敏 《核聚变与等离子体物理》 CAS CSCD 北大核心 2024年第2期157-162,共6页
通过在相衬成像系统光路中引入电控安全快门控制激光输出,并使用延迟电路实现了安全快门与HL-2A放电运行的同步触发,保障了诊断系统的安全运行,安全快门时间响应为26ms,其抖动误差1ms;利用四象限传感器实现了激光束斑位置的实时监测,获... 通过在相衬成像系统光路中引入电控安全快门控制激光输出,并使用延迟电路实现了安全快门与HL-2A放电运行的同步触发,保障了诊断系统的安全运行,安全快门时间响应为26ms,其抖动误差1ms;利用四象限传感器实现了激光束斑位置的实时监测,获得了HL-2A装置垂直和水平方向的振动数据。所发展的电控快门技术和激光实时监测系统不仅能够大幅提高相衬成像系统的安全性和可靠性,对于HL-2A/2M装置诊断系统的发展和完善也具有重要意义。 展开更多
关键词 相衬成像系统 电控快门 激光实时监测
下载PDF
相衬光学相干弹性成像的超分辨应变测量
17
作者 张展华 曹鑫 +3 位作者 詹伟浩 董博 谢胜利 白玉磊 《光学精密工程》 EI CAS CSCD 北大核心 2024年第12期1812-1823,共12页
相衬光学相干弹性成像的相位分辨率受限于系统的光源带宽,导致层析应变成像质量低。这严重制约了相衬光学相干弹性成像的实际应用与发展。为此,本文提出一种基于数据驱动的超分辨应变测量方法,以解决相位分辨率受限下的应变重构困难问... 相衬光学相干弹性成像的相位分辨率受限于系统的光源带宽,导致层析应变成像质量低。这严重制约了相衬光学相干弹性成像的实际应用与发展。为此,本文提出一种基于数据驱动的超分辨应变测量方法,以解决相位分辨率受限下的应变重构困难问题。首先,根据相衬光学相干弹性成像原理,搭建了层析应变测量模型,用于获取网络训练所需的数据集,解决实际测量过程中超分辨应变标签难以获取的问题。其次,构建深度卷积神经网络,通过带有层析分辨率受限特点的数据驱动方式,让网络学习低分辨相位与高分辨应变之间的映射关系,从而实现相衬光学相干弹性成像的超分辨应变测量。最后,采用数值验证和压缩变形加载实验对本文方法的性能进行验证。实验结果表明本文方法在窄带宽输出下能重构出宽带宽的应变测量效果,并且其信噪比相比于矢量方法和传统应变计算深度神经网络,分别提高了18.4 dB和1.45 dB。本文方法可以突破系统光源的带宽限制,在低分辨相位输入条件下实现超分辨应变测量,从而加快相衬光学相干弹性成像在力学性能表征、内部早期损伤探测等方面的应用前景。 展开更多
关键词 光学弹性成像 相衬技术 应变测量 深度神经网络 超分辨重构
下载PDF
基于贝叶斯神经网络的相位梯度计算方法
18
作者 张康洋 倪梓浩 +1 位作者 董博 白玉磊 《中国光学(中英文)》 EI CAS CSCD 北大核心 2024年第4期842-851,共10页
应变重构是相衬光学相干层析力学性能表征中的关键步骤,其需要准确计算出差分包裹相位的梯度分布。为了能够解决强噪声干扰下的相位梯度重构信噪比低的难题,提出了一种基于贝叶斯神经网络的相位梯度计算方法。首先,通过计算机模拟不同... 应变重构是相衬光学相干层析力学性能表征中的关键步骤,其需要准确计算出差分包裹相位的梯度分布。为了能够解决强噪声干扰下的相位梯度重构信噪比低的难题,提出了一种基于贝叶斯神经网络的相位梯度计算方法。首先,通过计算机模拟不同散斑噪声等级下的包裹相位图,并生成相应的理想相位梯度,以构建网络的训练集。其次,基于网络训练集采用贝叶斯推断理论学习强噪声环境下的包裹相位与相位梯度的“端到端”映射关系。最后,将相衬光学相干层析测量的差分包裹相位结果送入贝叶斯神经网络进行处理,实现高信噪比相位梯度预测。此外,通过借助贝叶斯神经网络的统计特性,以模型不确定度来定量评估相位梯度预测结果的可靠性。通过数值实验和三点弯曲力学加载实验对比分析了本文方法和主流矢量方法的性能。实验结果表明:在噪声较小的条件下,本文方法重构的相位梯度信噪比可提升8%;在噪声较强条件下,本文方法能成功恢复因相位条纹难以分辨而无法计算的相位梯度。此外,模型不确定度能够定量分析网络的相位梯度预测误差。可以预见,在样品形变复杂且先验信息未知的条件下,本工作为相衬光学相干层析提供了一种有效的应变重构方法,从而能实现高质量和高可靠的内部力学性能表征。 展开更多
关键词 光学相干层析成像 相衬技术 相位梯度计算 贝叶斯神经网络 形变测量
下载PDF
肾脏相位衬度两种成像技术的比较及分析
19
作者 刘安娜 彭屹峰 +2 位作者 肖体乔 杜国浩 何伟 《中国医学计算机成像杂志》 CSCD 北大核心 2024年第4期469-472,共4页
目的:分别采用衍射增强成像(DEI)和同轴成像(IOXI)技术进行小鼠肾脏组织的相位衬度成像研究,旨在评估两种成像方法的特性和效果。方法:分别在北京同步辐射装置(BSRF)4W1A及上海光源(SSRF)BL13W1上进行实验(分别实施DEI和IOXI)。经福尔... 目的:分别采用衍射增强成像(DEI)和同轴成像(IOXI)技术进行小鼠肾脏组织的相位衬度成像研究,旨在评估两种成像方法的特性和效果。方法:分别在北京同步辐射装置(BSRF)4W1A及上海光源(SSRF)BL13W1上进行实验(分别实施DEI和IOXI)。经福尔马林溶液固定的不同月龄(10、18、24月龄)小鼠的肾脏标本置于成像台进行成像,以图像衬度及分辨率等指标评估电荷耦合器件(CCD)获得的图像,具体评估指标包括显示的图像形态结构、衬度、分辨率等参数。结果:DEI技术获得的图像主要是显示血管结构。而IOXI技术获得的图像包含更多的细节,除了血管结构外,还能清晰显示包括肾小球在内的小鼠肾脏的微细结构,尤其在高分辨成像下,通过比较不同月龄的小鼠肾脏,初步获得小鼠老化的过程:首先从皮质肾小球的分布、走行及数量发生变化,到后期乃至终末期累及髓质,直小管及血管结构紊乱、皱缩以及肾脏呈硬化萎缩改变。结论:DEI和IOXI技术均能较好显示小鼠的肾脏血管结构,但IOXI技术更能显示包括肾小球在内的细微结构,这对未来研究肾脏病变乃至其余实质脏器的研究具有更加重要的价值。 展开更多
关键词 X线相衬成像 衍射增强成像 同轴成像 肾脏 比较
下载PDF
基于无透镜傅里叶变换数字全息的结构形貌测量
20
作者 张娅雅 段俊萍 张斌珍 《光通信技术》 北大核心 2024年第5期91-96,共6页
为了精确测量物体的形貌信息,提出了一种基于无透镜傅里叶变换数字全息的成像系统。首先,分析了无透镜傅里叶变换数字全息的成像原理,引入了倾斜平面校正方法;然后,搭建了成像系统平台,通过实验验证系统的成像性能。实验结果表明:系统... 为了精确测量物体的形貌信息,提出了一种基于无透镜傅里叶变换数字全息的成像系统。首先,分析了无透镜傅里叶变换数字全息的成像原理,引入了倾斜平面校正方法;然后,搭建了成像系统平台,通过实验验证系统的成像性能。实验结果表明:系统的实际分辨率为57.02 lp/mm。测量结果的相对误差仅为3.95%,充分验证了该系统卓越的成像性能。 展开更多
关键词 数字全息 形貌测量 相衬成像 反射式成像 无透镜傅里叶变换成像
下载PDF