期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Characterization and separation of DNA complexes containing poly-L-lysine with or without the modification of PEG by capillary electrophoresis
1
作者 孙烨 刘书朋 +2 位作者 储茂泉 宋姝贤 辛艳飞 《Journal of Shanghai University(English Edition)》 CAS 2009年第2期183-188,共6页
The characterization of complexes is particularly critical for quality control and development of gene delivery systems. Here, the method of capillary zone electrophoresis (CZE) for the characterization of DNA and p... The characterization of complexes is particularly critical for quality control and development of gene delivery systems. Here, the method of capillary zone electrophoresis (CZE) for the characterization of DNA and polyoL-lysine (MW 28 500) or DNA and poly-L-lysine modified with polyethylene glycol (MW10 000) complexes at various charge ratios in phosphate buffer is described firstly. During the characterization, DNA complexes can be separated into various components with different charge-to-mass ratio, i.e, components with single physicochemical property. And also the size and zeta potential of complexes were characterized by using photon correlation spectroscopy. This method is useful to characterize various complexes formed by DNA and polycations, and has the potential to separate complexes into homogeneous component for better transfection efficiency in vitro and in vivo in future. 展开更多
关键词 capillary electrophoresis (CE) poly-L-lysine (PLL) polyethylene glycol photon correlation spectroscopy (PCS)
下载PDF
Size measurement of nano-particles using self-mixing effect 被引量:1
2
作者 王华睿 沈建琪 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第11期871-874,共4页
In this letter, the technique of laser self-mixing effect is employed for nano-particle size analysis. In contrast to the photon correlation spectroscopy (PCS) and photon cross correlation spectroscopy (PCCS), the... In this letter, the technique of laser self-mixing effect is employed for nano-particle size analysis. In contrast to the photon correlation spectroscopy (PCS) and photon cross correlation spectroscopy (PCCS), the main advantages of this technique are sensitive, compact, low-cost, and simple experimental setup etc. An improved Kaczmarz projection method is developed in the inversion problem to extract the particle size distribution. The experimental results prove that nano-particle size can be measured reasonably by using the self-mixing effect technique combined with the improved projection algorithm. 展开更多
关键词 EXPERIMENTS NANOPARTICLES Particle size photon correlation spectroscopy photonS
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部