Physical Model of Drying Shrinkage of Recycled Aggregate Concrete 被引量:2
1
作者 郭远臣 WANG Xue QIAN Jueshi 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2015年第6期1260-1267,共8页
We prepared concretes(RC0, RC30, and RC100) with three different mixes. The poresize distribution parameters of RAC were examined by high-precision mercury intrusion method(MIM) and nuclear magnetic resonance(NMR... We prepared concretes(RC0, RC30, and RC100) with three different mixes. The poresize distribution parameters of RAC were examined by high-precision mercury intrusion method(MIM) and nuclear magnetic resonance(NMR) imaging. A capillary-bundle physical model with random-distribution pores(improved model, IM) was established according to the parameters, and dry-shrinkage strain values were calculated and verified. Results show that in all pore types, capillary pores, and gel pores have the greatest impacts on concrete shrinkage, especially for pores 2.5-50 and 50-100 nm in size. The median radii are 34.2, 31, and 34 nm for RC0, RC30, and RC100, respectively. Moreover, the internal micropore size distribution of RC0 differs from that of RC30 and RC100, and the pore descriptions of MIM and NMR are consistent both in theory and in practice. Compared with the traditional capillary-bundle model, the calculated results of IM have higher accuracy as demonstrated by experimental verifi cation. 展开更多
关键词 pore recycled aggregate concrete capillary-bundle physical model drying shrinkage deformation experimental research numerical simulation
下载PDF
Vector Shift Method for Islanding Detection Based on Simulation Test
2
作者 侯梅毅 高厚磊 +1 位作者 刘炳旭 邹贵彬 《Transactions of Tianjin University》 EI CAS 2008年第2期123-127,共5页
Vector shift(VS)is one of the typical methods used for islanding detection in distributed generations.This paper investigates the impact of both the active power imbalance and load variation on VS method.The investiga... Vector shift(VS)is one of the typical methods used for islanding detection in distributed generations.This paper investigates the impact of both the active power imbalance and load variation on VS method.The investigation was conducted via simulation test in the power system dynamic simulation laboratory of Shandong University.The results show that it will take longer time for the VS relay to detect islanding state with the decrease of active power imbalance.In some cases,the vector shift angle is smaller than the setting and VS method would not be able to detect islanding state.In addition,the performance of VS method is impacted by the load variation in normal operation in which the distributed generator is operated in parallel with the main grid.The simulation results show that VS method would cause nuisance tripping if the load changes sharply. It can be summarized that VS method would be unable to reliably discriminate islanding state and normal system disturbances in some cases. 展开更多
关键词 distributed generation islanding detection vector shift physical model simulation islanding operation
下载PDF