We prepared concretes(RC0, RC30, and RC100) with three different mixes. The poresize distribution parameters of RAC were examined by high-precision mercury intrusion method(MIM) and nuclear magnetic resonance(NMR...We prepared concretes(RC0, RC30, and RC100) with three different mixes. The poresize distribution parameters of RAC were examined by high-precision mercury intrusion method(MIM) and nuclear magnetic resonance(NMR) imaging. A capillary-bundle physical model with random-distribution pores(improved model, IM) was established according to the parameters, and dry-shrinkage strain values were calculated and verified. Results show that in all pore types, capillary pores, and gel pores have the greatest impacts on concrete shrinkage, especially for pores 2.5-50 and 50-100 nm in size. The median radii are 34.2, 31, and 34 nm for RC0, RC30, and RC100, respectively. Moreover, the internal micropore size distribution of RC0 differs from that of RC30 and RC100, and the pore descriptions of MIM and NMR are consistent both in theory and in practice. Compared with the traditional capillary-bundle model, the calculated results of IM have higher accuracy as demonstrated by experimental verifi cation.展开更多
Vector shift(VS)is one of the typical methods used for islanding detection in distributed generations.This paper investigates the impact of both the active power imbalance and load variation on VS method.The investiga...Vector shift(VS)is one of the typical methods used for islanding detection in distributed generations.This paper investigates the impact of both the active power imbalance and load variation on VS method.The investigation was conducted via simulation test in the power system dynamic simulation laboratory of Shandong University.The results show that it will take longer time for the VS relay to detect islanding state with the decrease of active power imbalance.In some cases,the vector shift angle is smaller than the setting and VS method would not be able to detect islanding state.In addition,the performance of VS method is impacted by the load variation in normal operation in which the distributed generator is operated in parallel with the main grid.The simulation results show that VS method would cause nuisance tripping if the load changes sharply. It can be summarized that VS method would be unable to reliably discriminate islanding state and normal system disturbances in some cases.展开更多
基金Funded by the National Natural Science Foundation of China(51202304)the China Postdoctoral Science Foundation(2014M552320)+1 种基金Scientific,the Technological Talents’Special Funds of Wanzhou District and Scientific and Technological Research Program of Chongqing Municipal Education Commission(KJ1401016)the Youth Project of Chongqing Three Gorges College(13QN-20)
文摘We prepared concretes(RC0, RC30, and RC100) with three different mixes. The poresize distribution parameters of RAC were examined by high-precision mercury intrusion method(MIM) and nuclear magnetic resonance(NMR) imaging. A capillary-bundle physical model with random-distribution pores(improved model, IM) was established according to the parameters, and dry-shrinkage strain values were calculated and verified. Results show that in all pore types, capillary pores, and gel pores have the greatest impacts on concrete shrinkage, especially for pores 2.5-50 and 50-100 nm in size. The median radii are 34.2, 31, and 34 nm for RC0, RC30, and RC100, respectively. Moreover, the internal micropore size distribution of RC0 differs from that of RC30 and RC100, and the pore descriptions of MIM and NMR are consistent both in theory and in practice. Compared with the traditional capillary-bundle model, the calculated results of IM have higher accuracy as demonstrated by experimental verifi cation.
文摘Vector shift(VS)is one of the typical methods used for islanding detection in distributed generations.This paper investigates the impact of both the active power imbalance and load variation on VS method.The investigation was conducted via simulation test in the power system dynamic simulation laboratory of Shandong University.The results show that it will take longer time for the VS relay to detect islanding state with the decrease of active power imbalance.In some cases,the vector shift angle is smaller than the setting and VS method would not be able to detect islanding state.In addition,the performance of VS method is impacted by the load variation in normal operation in which the distributed generator is operated in parallel with the main grid.The simulation results show that VS method would cause nuisance tripping if the load changes sharply. It can be summarized that VS method would be unable to reliably discriminate islanding state and normal system disturbances in some cases.