[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation con...[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places.展开更多
Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technol...Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP- MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.展开更多
本文利用微波消解对黄豆进行前处理,采用电感耦合等离子体质谱法(Inductively Coupled Plasma Mass Spectrometer,ICP-MS)对消解液中26种元素的含量进行测定,对方法的线性、精密度、准确度及质控样品进行验证。结果表明,各元素标准曲线...本文利用微波消解对黄豆进行前处理,采用电感耦合等离子体质谱法(Inductively Coupled Plasma Mass Spectrometer,ICP-MS)对消解液中26种元素的含量进行测定,对方法的线性、精密度、准确度及质控样品进行验证。结果表明,各元素标准曲线的相关系数均≥0.9990,线性关系良好,检出限为0.000583~0.453000 mg·kg^(-1),相对标准偏差≤5.513%,加标回收率为77%~113%,说明该方法能准确检测黄豆中无机元素,满足日常监测需求。展开更多
Benzene is a major industrial air pollutant and can cause serious human health disorders. In this paper an investigation on benzene destruction, in an atmospheric-pressure fast-flow pulsed DC-discharge by means of las...Benzene is a major industrial air pollutant and can cause serious human health disorders. In this paper an investigation on benzene destruction, in an atmospheric-pressure fast-flow pulsed DC-discharge by means of laser ionization combined with time-of-flight (TOF) mass spectrometry, is reported. Most by-products including transient reactive species from the benzene discharge were characterized by molecular beam sampling combined with TOF mass spectrometry. It is showed that, with a gas mixture of 0.5% C6H6 in Ar, benzene can be effectively destroyed by discharge plasma. The intermediate species consisted of small fragments of CnHm (n=3-5, m = 1-11), cycle-chain species of CnHm (n =6-9, m = 7-10) and polycyclic species CnHm (n ≥9, m = 8-12). The alternation of mass peaks (intensity) with even/odd electrons was observed in the measured mass spectra. The results indicated that the alternation is mainly due to the different ionization potentials of the open shell and close shell species. Based on the examination of the features of the species' composition, the primary reaction pathways are proposed and discussed.展开更多
An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+H...An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+HCl with microwave digestion followed by dilution with ultrapure water, then the above 16 impurity elements in the solution were analyzed directly by ICP-MS. The impurity elements were introduced by the helium gas or hydrogen gas into the octopole reaction system(ORS) to eliminate the polyatomic interferences caused by the high salty matrixes. The matrix effect was minimized through matrix matching,and Be, Y and Rh were used as internal standard elements. The working parameters of the instrument were optimized. The results show that the method has good precision and high accuracy. The detection limits for the investigated elements are in the range of0.9-37.5 ng/L, the relative standard deviation of each element is within 1.1%-4.8%, and the recovery of each element is 90%-108%.展开更多
This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115I...This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115In and ^209Bi as internal standards.According to the method of Safety and Technical Standards for Cosmetics(2015),a mathematical model was established to evaluate the sources and components of uncertainty for the determination of lead,cadmium and arsenic in cosmetics.The results showed that the uncertainties in the determination of lead,cadmium,and arsenic elements in cosmetics were(10.1±0.6)mg/kg,k=2,(4.84±0.28)mg/kg,k=2,(2.04±0.18)mg/kg,k=2,respectively.The main factors that affect the uncertainty of determination results were standard substance,calibration curve,recovery and measurement repeatability.展开更多
Using ultra-fine sample for determination 42 elements by pressurized acid digestion -ICP-MS, the mass of test portion can be reduced to 2 mg yet maintain the representation. And acid used for digestion could be reduce...Using ultra-fine sample for determination 42 elements by pressurized acid digestion -ICP-MS, the mass of test portion can be reduced to 2 mg yet maintain the representation. And acid used for digestion could be reduced to less than 0.5 mL, reaction time also largely reduced.展开更多
Inductively coupled plasma mass spectrometry (ICP-MS) was used to detect trace metal impurities in reagents such as H2O2, HNO3and H2SO4. The limit of detection to metal elements can be down to 2-20 ng/L in H2O2 and HN...Inductively coupled plasma mass spectrometry (ICP-MS) was used to detect trace metal impurities in reagents such as H2O2, HNO3and H2SO4. The limit of detection to metal elements can be down to 2-20 ng/L in H2O2 and HNO3 and 0.1-1.0 ng/L in H2SO4.展开更多
To improve precision of analytical results of pressurized acid digestion-ICP-MS, the first step is to improve the homogeneity by reducing the particle size of sample. Using of ultra-fine sample (-500 mesh) can reduce ...To improve precision of analytical results of pressurized acid digestion-ICP-MS, the first step is to improve the homogeneity by reducing the particle size of sample. Using of ultra-fine sample (-500 mesh) can reduce the mass of the sample and the acid. The satisfactory precision is achieved at 2 mg sampling mass.展开更多
基金Supported by the National Science Foundation for Post-doctoral Scientists of China(20070410616)Excellent Youth Foundation of He'nan Scientific Committee(074100510018)~~
文摘[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places.
文摘Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP- MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.
基金supported by National Natural Science Foundation of China (No. 10875023)Scientific and Technical Key Project of Educational Ministry of China (No. 108034)
文摘Benzene is a major industrial air pollutant and can cause serious human health disorders. In this paper an investigation on benzene destruction, in an atmospheric-pressure fast-flow pulsed DC-discharge by means of laser ionization combined with time-of-flight (TOF) mass spectrometry, is reported. Most by-products including transient reactive species from the benzene discharge were characterized by molecular beam sampling combined with TOF mass spectrometry. It is showed that, with a gas mixture of 0.5% C6H6 in Ar, benzene can be effectively destroyed by discharge plasma. The intermediate species consisted of small fragments of CnHm (n=3-5, m = 1-11), cycle-chain species of CnHm (n =6-9, m = 7-10) and polycyclic species CnHm (n ≥9, m = 8-12). The alternation of mass peaks (intensity) with even/odd electrons was observed in the measured mass spectra. The results indicated that the alternation is mainly due to the different ionization potentials of the open shell and close shell species. Based on the examination of the features of the species' composition, the primary reaction pathways are proposed and discussed.
基金Project(21271187)supported by the National Natural Science Foundation of ChinaProject(cstc2013jcyj A10088)supported by the Chongqing Natural Science Foundation,China+1 种基金Projects(2013FJ3093,2013SK3268)supported by the Science and Technology Project of Hunan Province,ChinaProject(KJZH14217)supported by Achievement Transfer Education in Chongqing,China
文摘An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+HCl with microwave digestion followed by dilution with ultrapure water, then the above 16 impurity elements in the solution were analyzed directly by ICP-MS. The impurity elements were introduced by the helium gas or hydrogen gas into the octopole reaction system(ORS) to eliminate the polyatomic interferences caused by the high salty matrixes. The matrix effect was minimized through matrix matching,and Be, Y and Rh were used as internal standard elements. The working parameters of the instrument were optimized. The results show that the method has good precision and high accuracy. The detection limits for the investigated elements are in the range of0.9-37.5 ng/L, the relative standard deviation of each element is within 1.1%-4.8%, and the recovery of each element is 90%-108%.
文摘This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115In and ^209Bi as internal standards.According to the method of Safety and Technical Standards for Cosmetics(2015),a mathematical model was established to evaluate the sources and components of uncertainty for the determination of lead,cadmium and arsenic in cosmetics.The results showed that the uncertainties in the determination of lead,cadmium,and arsenic elements in cosmetics were(10.1±0.6)mg/kg,k=2,(4.84±0.28)mg/kg,k=2,(2.04±0.18)mg/kg,k=2,respectively.The main factors that affect the uncertainty of determination results were standard substance,calibration curve,recovery and measurement repeatability.
文摘Using ultra-fine sample for determination 42 elements by pressurized acid digestion -ICP-MS, the mass of test portion can be reduced to 2 mg yet maintain the representation. And acid used for digestion could be reduced to less than 0.5 mL, reaction time also largely reduced.
文摘Inductively coupled plasma mass spectrometry (ICP-MS) was used to detect trace metal impurities in reagents such as H2O2, HNO3and H2SO4. The limit of detection to metal elements can be down to 2-20 ng/L in H2O2 and HNO3 and 0.1-1.0 ng/L in H2SO4.
文摘To improve precision of analytical results of pressurized acid digestion-ICP-MS, the first step is to improve the homogeneity by reducing the particle size of sample. Using of ultra-fine sample (-500 mesh) can reduce the mass of the sample and the acid. The satisfactory precision is achieved at 2 mg sampling mass.