期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
The Application of Synthetic Fuzzy Assessing Method in Measurement and Control System of Plating Solution Evaporator
1
作者 周晓兵 费敏锐 陈维刚 《Journal of Donghua University(English Edition)》 EI CAS 2004年第3期134-138,共5页
The synthetic fuzzy assessing method is usually applied to sensory evaluation. The method has simple and reliable virtue, and it is consistent with objective evaluation results. Using this method, system status of pla... The synthetic fuzzy assessing method is usually applied to sensory evaluation. The method has simple and reliable virtue, and it is consistent with objective evaluation results. Using this method, system status of plating solution evaporator is evaluated, and the result is applied to compensate a fuzzy controller. Experimental results have shown the correctness and the validity of the proposed approach. 展开更多
关键词 Plating solution evaporator Synthetic fuzzy assessing method fuzzy control PC-BASED configuration software
下载PDF
Heat Transfer with Flow and Phase Change in an Evaporator of Miniature Flat Plate Capillary Pumped Loop
2
作者 Zhongmin WAN Wei LIU +1 位作者 Zhaoqing ZHENG A. Nakayama 《Journal of Thermal Science》 SCIE EI CAS CSCD 2007年第3期254-263,共10页
An overall two-dimensional numerical model of the miniature flat plate capillary pumped loop (CPL) evaporator is developed to describe the liquid and vapor flow, heat transfer and phase change in the porous wick str... An overall two-dimensional numerical model of the miniature flat plate capillary pumped loop (CPL) evaporator is developed to describe the liquid and vapor flow, heat transfer and phase change in the porous wick structure, liquid flow and heat transfer in the compensation cavity and heat transfer in the vapor grooves and metallic wall. The entire evaporator is solved with SIMPLE algorithm as a conjugate problem. The effect of heat conduction of metallic side wall on the performance of miniature flat plate CPL evaporator is analyzed, and side wall effect heat transfer limit is introduced to estimate the performance of evaporator. The shape and location of vapor-liquid interface inside the wick are calculated and the influences of applied heat flux, liquid subcooling, wick material and metallic wall material on the evaporator performance are investigated in detail. The numerical results obtained are useful for the miniature flat plate evaporator performance optimization and design of CPL. 展开更多
关键词 capillary pumped loop flat plate evaporator side wall effect heat transfer limit wick structure
原文传递
Characteristic of Local Boiling Heat Transfer of Ammonia and Ammonia/Water Binary Mixture on the Plate Type Evaporator 被引量:2
3
作者 Akio OKAMOTO Hirofumi ARIMA Yasuyuki IKEGAMI 《Journal of Thermal Science》 SCIE EI CAS CSCD 2011年第4期332-342,共11页
Power generation using small temperature difference such as ocean thermal energy conversion(OTEC)and discharged thermal energy conversion(DTEC)is expected to be the countermeasures against global warming problem.As am... Power generation using small temperature difference such as ocean thermal energy conversion(OTEC)and discharged thermal energy conversion(DTEC)is expected to be the countermeasures against global warming problem.As ammonia and ammonia/water are used in evaporators for OTEC and DTEC as working fluids,the research of their local boiling heat transfer is important for improvement of the power generation efficiency.Measurements of local boiling heat transfer coefficients were performed for ammonia/water mixture(z=0.9-1)on a vertical flat plate heat exchanger in a range of mass flux(7.5-15 kg/m2s),heat flux(15-23 kW/m 2),and pressure(0.7-0.9 MPa).The result shows that in the case of ammonia/water mixture,the local heat transfer coefficients increase with an increase of mass flux and composition of ammonia,and decrease with an increase of heat flux. 展开更多
关键词 Local Heat Transfer Ammonia/Water Mixture plate Type evaporator OTEC
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部